• Title/Summary/Keyword: False Aneurysm

Search Result 67, Processing Time 0.023 seconds

True Aneurysm of the Common Digital Artery: Case Report (온 바닥 쪽 손가락 동맥에서 발생한 동맥류의 치험례)

  • Jang, Joon-Chul;Jeong, Seong-Ho;Han, Seung-Kyu;Kim, Woo-Kyung
    • Archives of Plastic Surgery
    • /
    • v.38 no.3
    • /
    • pp.315-318
    • /
    • 2011
  • Purpose: An aneurysm is defined as a permanent, localized dilation of an artery with a 50% increase in diameter over its expected normal diameter. Aneurysms can be classified by cause as traumatic and nontraumatic. Traumatic aneurysms can be divided into true and false aneurysms. Nontraumatic causes of peripheral artery aneurysms include mycotic, atherosclerotic, inflammatory, and idiopathic. In the hand, true aneurysms occurring at the common digital artery have been rarely reported. We present a rare case of a true aneurysm of the common digital artery that was resected and reconstructed using a reversed vein graft. Methods: A 49-year-old male patient was refered to our institution with a $0.73{\times}0.44{\times}1.37cm$ sized pulsating mass between 2nd and 3rd flexor digitorum tendons on Lt. palm area. The mass had been present for 5 years and had increased in size over the previous year. No history of trauma was reported. After a physical examination and ultrasound sonography review, a diagnosis of aneurismal dilatation of common digital artery was made. Surgical treatment by excision of the aneurysm, and a reversed vein graft was performed. Results: Histologic examination of the specimen ($3.4{\times}0.7cm$) showed aneurismal dilatation, with elastin fibers present in the arterial wall. The lesions were healed without any complications and there were no evidence of recurrence. Doppler examination of the reconstruction showed good perfusion. Conclusion: Early excision is recommended to relieve symptoms and avoid neurologic damage. Also, artery reconstruction can be performed by primary end-to-end anastomosis or the placement of a reversed interposition vein graft. Micro surgical repair was the only possible treatment in this case. The authors believe that the vascular anatomy should always be restored as natural as possible.

Traumatic Internal Maxillary Artery Pseudoaneurysm Caused by Fracture of the Mandible Ramus: A Case Report (턱뼈가지의 골절로 인한 내상악동맥의 가성동맥류 1례)

  • Han, Chang Dok;Kim, Young Hyo;Kim, Kyu-Sung;Choi, Hoseok
    • Journal of Trauma and Injury
    • /
    • v.25 no.1
    • /
    • pp.32-35
    • /
    • 2012
  • Traumatic pseudoaneurysms in the head and neck region are very rare. Particularyly, pseudoaneurysms of the internal maxillary artery are known to be very rare. The authors report a 20-year old male who was diagnosed as having a pseudoaneurysm of the internal maxillary artery. The cause was assumed to be a mandible ramus fracture. When he visited our emergency room, we did not consider a pseudoaneurysm because of his other life-threatening conditions. Fortunately, he re-visited our hosipital before the aneurysm ruptured. He was diagnosed with angiography and was treated by using embolization with glue. The rupture of the pseudoaneurysm could have caused a life-threatening hemorrhage.

Traumatic Arteriovenous Fistula (외상성 동정맥루 1례 보고)

  • 오세웅
    • Journal of Chest Surgery
    • /
    • v.20 no.4
    • /
    • pp.847-850
    • /
    • 1987
  • Traumatic arteriovenous fistula is relatively uncommon. The proper designation for what is called a false aneurysm is pulsating hematoma, which occurs when there is a small laceration of the wall of a large artery will continuing leakage of blood from the artery into surrounding tissues. The extent of growth of the pulsating hematoma depends on the strength of the surrounding fascial tissues. We experienced one case of arteriovenous fistula with hematoma, due to operative injuries, and operated successfully, and report the case.

  • PDF

Bentall's Operation -5 Case Report- (Teflon felt를 이용한 Bentall 술식 치험 5례)

  • 정철하
    • Journal of Chest Surgery
    • /
    • v.27 no.2
    • /
    • pp.153-156
    • /
    • 1994
  • Bentall`s operation for repair of annuloaortic ectasia has been associated with postoperative bleeding and with false aneurysm of the anastomotic site between the coronary orifice and composite graft.Among 5 cases, 2 cases have been operated direct anastomosis between coronary artery and vascular graft.Remained 3 cases have been operated with doughnutlike Teflon felt buttress.The technique of sandwiching the freed button of aortic wall bearing the coronary artery ostium between an outer Teflon felt doughnutlike buttress and the inner composite graft provides a leak-proof anastomosis.We experienced one case reoperation for bleeding at coronary anastomotic site above method.

  • PDF

Surgical Treatment of Postinfarction Posterobasal Left Ventricular Aneurysm - Report of 2 cases- (심근경색 후 발생한 후기저부 좌심실류의 외과적 치험 -2예 보고 -)

  • Kim, Jae-Hyun;Na, Chan-Young;Kim, Woong-Han;Oh, Sam-Sae;Baek, Man-Jong;Whang, Sung-Wook;Kang, Chang-Hyun;Lee, Cheul;Chang, Yun-Hee;Jo, Won-Min;Seo, Hong-Ju;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.975-978
    • /
    • 2003
  • At least 88 percents of ventricular aneurysms result from anterior infarction, while the remainder follow inferior infarction. Posterior infarction that produce a distinct left ventricular aneurysm is unusual. We report two operative cases of postinfarction posterobasal left ventricular aneurysms, one with a true aneurysm and the other with a false one.

An Experimental Study on the Cause of Signal Inhomogeneity for Magnetic Resonance Angiography Using Phantom Model of Anterior Communicating(A-com) Artery (전교통동맥 모형을 이용한 자기공명혈관촬영술의 신호 불균일에 관한 실험적 연구)

  • Yoo, Beong-Gyu;Chung, Tae-Sub
    • Journal of radiological science and technology
    • /
    • v.25 no.1
    • /
    • pp.55-62
    • /
    • 2002
  • Aneurysm-mimicking findings were frequently visualized due to hemodynamical causes of dephasing effects around area of A-com artery during magnetic resonance angiography(MRA) and these kind of phenomena have not been clearly known yet. We investigated the hemodynamical patterns of dephasing effect around area of the A-com artery that might be a cause of false intracranial aneurysms on MRA. For experimental study, We used hand-made silicon phantoms of the asymmetric A-com artery as like a bifurcation configuration. In a closed circulatory system with UHDC computer driven cardiac pump system. MRA and fast digital subfraction angiography(DSA) involved the use of these phantoms. Flow patterns were evaluated with axial and coronal imaging of MRA(2D-TOF, 3D-TOF) and DSA of Phantoms constructed from an automated closed-type circulatory system filled with glycerol solution [circulation fluid(glycerol:water = 1:1.4)]. These findings were then compared with those obtained from computational fluid dynamic(CFD) for inter-experimental correlation study. Imaging findings of MRA, DSA and CFD on inflow zone according to the following: a) MRA demonstrated high signal intensity zone as inflow zone on silicon phantom; b) Patterns of DSA were well matched with MRA on trajectory of inflow zone; and c) CFD were well matched with MRA on the pattern of main flow. Imaging findings of MRA. DSA and CFD on turbulent flow zone according to the following: a) MRA demonstrated hyposignal intensity zone at shoulder and axillar zone of main inflow; b) DSA delineated prominent vortex flow at the same area. The hemodynamical causes of signal defect, which could Induce the false aneurysm on MRA, turned out to be dephasing effects at axilla area of bifurcation from turbulent flow as the results of MRA, DSA and CFD.

  • PDF

Evaluation of Cerebral Aneurysm with High Resolution MR Angiography using Slice Interpolation Technique: Correlation wity Digital Subtraction Angiography(DSA) and MR Angiography(MRA) (Slice Interpolation기법의 고해상도 자기공명혈관조영술을 이용한 뇌동맥류의 진단 : 디지탈 감산 혈관조영술과 자기공명 혈관조영술의 비교)

  • ;;;Daisy Chien;Gerhard Laub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.94-102
    • /
    • 1997
  • Purpose: There have been some efforts to diagnose intracranial aneurysm through a non-invasive method using MRA, although the process may be difficult when the lesion is less than 3mm. The present study prospectively compares the results of high resolution, fast speed slice interpolation MRA and DSA thereby examing the potentiality of primary non-invasive screening test. Materials and Methods: A total of 26 cerebral aneurysm lesions from 14 patients with subarachnoid hemorrhage from ruptured aneurysm (RA) and 5 patients with unruptured aneurysm(UA). In all subjects, MRA was taken to confirm the vessel of origin, definition of aneurysm neck and the relationship of the aneurysm to nearby small vessels, and the results were compared with the results of DSA. The images were obtained with 1.5T superconductive machine (Vision, Siemens, Erlangen, Germany) on 4 slabs of MRA using slice interpolation. The settings include TR/TE/FA=30/6.4/25, matrix $160{\times}512$, FOV $150{\times}200$, 7minutes 42 seconds of scan time, effective thickness of 0.7 mm and an entire thickness of 102. 2mm. The images included structures from foramen magnum to A3 portion of anterior cerebral artery. MIP was used for the image analysis, and multiplanar reconstruction (MPR) technique was used in cases of intracranial aneurysm. Results: A total of 26 intracranial aneurysm lesions from 19 patients with 2 patients having 3 lesion, 3 patients having 2 lesions and the rest of 14 patients having 1 lesion each were examined. Among those, 14 were RA and 12 were UA. Eight lesions were less than 2mm in size, 9 lesions were 3-5mm, 7 were 6-9mm and 2 were larger than IOmm. On initial exams, 25 out of 26 aneurysm lesions were detected in either MRA or DSA showing 96% sensitivity. Specificity cannot be estimated since there was no true negative of false positive findings. When MRA and MPR were used concurrently for the confirmation of size and shape, the results were equivalent to those of DSA, while in the confirmation of aneurysm neck and parent vessels, the concurrent use of MRA and MPR was far superior to the sole use of either MRA or DSA. Conclusion: High resolution MRA using slice interpolation technique showed equal results as those of DSA for the detection of intracranial aneurysm, and may be used as a primary non-invasive screening test in the future.

  • PDF

Aorta Remodeling after Endovascular Treatment of a Chronic DeBakey IIIb Aneurysm and Simultaneous Palliation of a Renal Cell Carcinoma

  • Kim, Do Jung;Lee, Kwang-Hun;Lim, Sun-Hee;Chung, Byung Ha;Song, Suk-Won
    • Journal of Chest Surgery
    • /
    • v.48 no.2
    • /
    • pp.142-145
    • /
    • 2015
  • We report the case of a patient with a chronic DeBakey type IIIb aneurysm who underwent thoracic endovascular aortic repair to seal the primary entry tear and stent-graft insertion to cover the re-entry tear at the renal artery. The procedure was performed in order to achieve complete thrombosis in the entire thoracoabdominal false lumen, leading to favorable aortic remodeling. Simultaneously, ethanol ablation and renal artery embolization were performed to treat a renal tumor suspicious of renal cell carcinoma. Radical nephrectomy then confirmed clear cell carcinoma. To the best of our knowledge, no other cases of this type have been reported in the Korean literature.

Surgical Treatment of Left Subclavian Aneurysm -A case report- (Subclavian artery 의 동맥류 -1예 수술 경험-)

  • Lee, Sung Haing;Lee, Sung Koo;Han, Sung Sae;Lee, Khil Rho;Kim, Song Myung
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.245-250
    • /
    • 1976
  • A 33 year-old man was admitted with chief complaints of severe sharp pain on left upper interscapular region and motor weakness of left arm for 9 days. He had a history of blunt trauma over left shoulder about 3 years ago. Physical examination showed a ping pong ball sized mass which was located at the left supraclavicular area and was firm, fixed, and nonpulsatile. No bruit or murmur was obtained over the mass. Ipsilaterally, radial, ulnar, and brachial pulse were very weak and ptosis and anhidrosis were noticed. Neurologic examination revealed moderate or severe weakness of flexion and extension of left elbow, wrist and fingers, and anesthesia of the skin in left C8-T1 dermatome and hypalgesia in left C6-C7 dermatome. Retrograde aortography demonstrated complete obstruction of left subclavian artery. An exploratory operation was performed through the left 4th intercostal space. It was found that the mass was a left subclavian aneurysm of traumatic false type. Proximal and distal ligation of the aneurysm were applied and the sac was partially removed. The continuity of the subclavain artery was established by the use of a 6mm. Dacron graft from the root of the subclavian to the axillary artery. Postoperatively the patient was improved from the circulatory and neurologic disturbances.

  • PDF

clinical analysis of vascular trauma (혈관손상의 임상적 고찰)

  • 성숙환
    • Journal of Chest Surgery
    • /
    • v.19 no.2
    • /
    • pp.288-294
    • /
    • 1986
  • During the period from Mar. 1983 to Feb. 1986, 22 patients with vascular trauma were treated at Capital Armed General Hospital. 1] 11 patients had arterial injury alone, 6 patients had venous injury alone, and 5 patients had both arterial and venous injuries. 2] The mechanism of injury in these 22 patients was 7 penetrating non-gun shot wounds, 5 blast fragments injuries, 4 iatrogenic injuries, 4 blunt injuries, 2 gun shot wounds. 3] The method of 16 arterial repair was 5 autogenous saphenous vein graft, 8 synthetic vascular graft, 1 end to end anastomosis, 2 lateral suture. Midterm patency of 16 repairs was 100% within 1 months. 4] The method of 11 venous repair was 1 autogenous saphenous vein graft, 2 onlay vein patch, 2 ligation, 1 lateral suture. The thrombotic obstructions occurred in 4 repairs [36.4%], but they were resolved somewhat with heparinization. 5] Uncommon cases of false aneurysm of internal carotid artery and laceration of retrohepatic inferior vena cava were summarized.

  • PDF