Minimally Invasive Multi-Level Posterior Lumbar Interbody Fusion Using a Percutaneously Inserted Spinal Fixation System : Technical Tips, Surgical Outcomes

  • Kim, Hyeun-Sung;Park, Keun-Ho;Ju, Chag-Il;Kim, Seok-Won;Lee, Seung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.5
    • /
    • pp.441-445
    • /
    • 2011
  • Objective : There are technical limitations of multi-level posterior pedicle screw fixation performed by the percutaneous technique. The purpose of this study was to describe the surgical technique and outcome of minimally invasive multi-level posterior lumbar interbody fusion (PLIF) and to determine its efficacy. Methods : Forty-two patients who underwent mini-open PLIF using the percutaneous screw fixation system were studied. The mean age of the patients was 59.1 (range, 23 to 78 years). Two levels were involved in 32 cases and three levels in 10 cases. The clinical outcome was assessed using the visual analog scale (VAS) and Low Back Outcome Score (LBOS). Achievement of radiological fusion, intra-operative blood loss, the midline surgical scar and procedure related complications were also analyzed. Results : The mean follow-up period was 25.3 months. The mean LBOS prior to surgery was 34.5, which was improved to 49.1 at the final follow up. The mean pain score (VAS) prior to surgery was 7.5 and it was decreased to 2.9 at the last follow up. The mean estimated blood loss was 238 mL (140-350) for the two level procedures and 387 mL (278-458) for three levels. The midline surgical scar was 6.27 cm for two levels and 8.25 cm for three level procedures. Complications included two cases of asymptomatic medial penetration of the pedicle border. However, there were no signs of neurological deterioration or fusion failure. Conclusion : Multi-level, minimally invasive PLIF can be performed effectively using the percutaneous transpedicular screw fixation system. It can be an alternative to the traditional open procedures.

Lateral Lumbar Interbody Fusion and in Situ Screw Fixation for Rostral Adjacent Segment Stenosis of the Lumbar Spine

  • Choi, Young Hoon;Kwon, Shin Won;Moon, Jung Hyeon;Kim, Chi Heon;Chung, Chun Kee;Park, Sung Bae;Heo, Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.755-762
    • /
    • 2017
  • Objective : The purpose of this study is to describe the detailed surgical technique and short-term clinical and radiological outcomes of lateral lumbar interbody fusion (LLIF) and in situ lateral screw fixation using a conventional minimally invasive screw fixation system (MISF) for revision surgery to treat rostral lumbar adjacent segment disease. Methods : The medical and radiological records were retrospectively reviewed. The surgery was indicated in 10 consecutive patients with rostral adjacent segment stenosis and instability. After the insertion of the interbody cage, lateral screws were inserted into the cranial and caudal vertebra using the MISF through the same LLIF trajectory. The radiological and clinical outcomes were assessed preoperatively and at 1, 3, 6, and 12 months postoperatively. Results : The median follow-up period was 13 months (range, 3-48 months). Transient sensory changes in the left anterior thigh occurred in 3 patients, and 1 patient experienced subjective weakness; however, these symptoms normalized within 1 week. Back and leg pain were significantly improved (p<0.05). In the radiological analysis, both the segmental angle at the operated segment and anterior disc height were significantly increased. At 6 months postoperatively, solid bony fusion was confirmed in 7 patients. Subsidence and mechanical failure did not occur in any patients. Conclusion : This study demonstrates that LLIF and in situ lateral screw fixation may be an alternative surgical option for rostral lumbar adjacent segment disease.

A Study on the Variable Factors for Brain Perfusion SPECT(Diamox) Scan (Brain Perfusion SPECT(Diamox) 검사의 수행결과에 영향을 주는 요인)

  • Lee, Jin-Hyeong;Kim, Sang-Eon;Park, Hyeon-Soo;Park, Yeoung-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.99-103
    • /
    • 2011
  • Purpose: Head movement during brain perfusion SPECT (Diamox) scan is a one of important issues which decreases image quality. It also causes repeated scans. This study was designed to evaluate variable factors causing scan failures. Materials and Methods: 676 patients (359 men, 317 women, age average $54.5{\pm}18.4$) for brain perfusion SPECT (Diamox) scan from March, 2010 to Feb. 2011 were used as a subject. Age data and the kind of disease(Moyamoya disease (MMD), None moyamoya disease (NMMD), Cerebral infarction (CI)), test performance outcome (success,failure) were collected. The head movement factors(gender, disease, age, head fixation device) were evaluated by chi-square test and logistic regression analysis Results: The result showed that men had higher scan failure rate than women. Seniors in seventies(men 3.4%, women 1.5%) showed the most highest failure rate. Using head fixation device increased scan success rate up to 94.4~97.7%. The scan success rate is dependent upon gender, head fixation device by chi-square test(${\chi}^2$=3.8 (df=1, p<0.05), ${\chi}^2$=10.4 (df=1, p<0.001)) Gender, disease(CI), head fixation device showed very effective result in logistic regression analysis.(Wald=3.3 (p<0.07), Wald=3.7 (p<0.05), Wald=9.3 (p<0.05) Conclusion: It is demonstrated that gender, disease, using head fixation device is statistically very useful factors. Especially, head fixation device is a main key minimizing repeated scan.

  • PDF

Humeral intramedullary nail bending following trauma: a case report

  • Siem A. Willems;Alexander P. A. Greeven
    • Journal of Trauma and Injury
    • /
    • v.36 no.1
    • /
    • pp.65-69
    • /
    • 2023
  • The surgical approach for humeral implant failure can be challenging due to neurovascular anatomy and the possible necessity of osteosynthesis removal. We present a rare case of humeral nail bending after secondary trauma in a patient with preexistent nonunion of the humerus after intramedullary nailing. During revision surgery, the nail was sawed in half and the distal part was removed, followed by plate osteosynthesis with cable fixation to achieve absolute stability. The patient regained a full range of motion 1 year after surgery, and complete healing of the fracture was seen on imaging.

Surgical Treatment of the Atypical Femoral Fracture: Overcoming Femoral Bowing

  • Lee, Kyung-Jae;Min, Byung-Woo
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.202-209
    • /
    • 2018
  • Atypical femoral fractures differ from ordinary femoral diaphyseal or subtrochanteric fractures in several aspects. Although several authors have reported the results of surgical treatment for atypical femoral fractures, the rate of complications (e.g., delayed union, nonunion, fixation failure, and reoperation) is still high. Therefore, we reviewed principles of surgical treatment and describe useful methods for overcoming femoral bowing in these high-risk patients.

Instrumentation Failure after Partial Corpectomy with Instrumentation of a Metastatic Spine

  • Park, Sung Bae;Kim, Ki Jeong;Han, Sanghyun;Oh, Sohee;Kim, Chi Heon;Chung, Chun Kee
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.3
    • /
    • pp.415-423
    • /
    • 2018
  • Objective : To identify the perioperative factors associated with instrument failure in patients undergoing a partial corpectomy with instrumentation (PCI) for spinal metastasis. Methods : We assessed the one hundred twenty-four patients with who underwent PCI for a metastatic spine from 1987 to 2011. Outcome measure was the risk factor related to implantation failure. The preoperative factors analyzed were age, sex, ambulation, American Spinal Injury Association grade, bone mineral density, use of steroid, primary tumor site, number of vertebrae with metastasis, extra-bone metastasis, preoperative adjuvant chemotherapy, and preoperative spinal radiotherapy. The intraoperative factors were the number of fixed vertebrae, fixation in osteolytic vertebrae, bone grafting, and type of surgical approach. The postoperative factors included postoperative adjuvant chemotherapy and spinal radiotherapy. This study was supported by the National Research Foundation grant funded by government. There were no study-specific biases related to conflicts of interest. Results : There were 15 instrumentation failures (15/124, 12.1%). Preoperative ambulatory status and primary tumor site were not significantly related to the development of implant failure. There were no significant associations between insertion of a bone graft into the partial corpectomy site and instrumentation failure. The preoperative and operative factors analyzed were not significantly related to instrumentation failure. In univariable and multivariable analyses, postoperative spinal radiotherapy was the only significant variable related to instrumentation failure (p=0.049 and 0.050, respectively). Conclusion : When performing PCI in patients with spinal metastasis followed by postoperative spinal radiotherapy, the surgeon may consider the possibility of instrumentation failure and find other strategies for augmentation than the use of a bone graft for fusion.

Soil Characteristics and Improvement of Reclaimable Hillside Land (산지토양(山地土壤)의 특성(特性)과 개량(改良))

  • Ryu, In-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.11 no.4
    • /
    • pp.247-262
    • /
    • 1979
  • Majority of reclaimable soils in hillside lands in Korea are red yellow soils, with exception in Jeju island, where most of reclaimable hillside lands are composed of volcanic ash soils. Songjeong, Yesan and Samgag series are the major soil series of red yellow soils which are available for the reclamation. When observed in the fields, they are distinguished as reddish brown clay loam, red yellow sand loam and yellowish brown sand loam. They have moderately good physical properties but their chemical properties are generally poor for crop cultivations. The chemical properties of red yellow soils, as compared to long time cultivated (matured) soils, are characterized by very low pH, high in exchangeable Al content and phosphorus fixation capacity. Also extraodinary low available phosphorus and organic matter contents are generally observed. On the other, the chemical properties of volcanic ash soils are characterized by high armophous Fe and Al hydroxides and organic matter contents, which are the causative factors for the extremely high phosphorus fixation capacity of the soils. The phosphorus fixation capacity of volcanic acid soils are as high as 5-10 times of that of red yellow soils. Poor growth of crops on newly reclaimed red yellow soils are mainly caused by very low available P and pH and high exchangeable Al. Relatively high P fixation capacity renders the failure of effective use of applied P when the amount of application is not sufficient. Applications of lime to remove the exchangeable Al and relatively large quantity of P to lower the P fixation capacity and to increase the available P are the major recommendations for the increased crop production on red yellow hillside soils. Generally recommendable amounts of lime and P to meet the aforementioned requirements, are 200-250kg/10a of lime and $30-35kg\;P_2O_5/10a$. Over doses of lime. frequently induces the K, B, arid Zn deficiencies and lowers the uptake of P. In volcanic ash soils, it is difficult to alter the exchangeable Al and the P fixation capacity by liming and P application. This may be due to the peculiarity of volcanic ash soil in chemical properties. Because of this feature, the amelioration of volcanic ash soils is not as easy as in the case of red yellow soils. Application of P as high as $100kg\;P_2O_5/10a$ is needed to bring forth the significant yield response in barley. Combined applications of appropriate levels of P, lime, and organic matter, accompanied by deep plowing, results in around doubling of the yields of various crops on newly reclaimed red yellow soils.

  • PDF

Anchor Hole Augmentation with Bone Cement in Arthroscopic Rotator Cuff Repair (관절경적 회전근 개 봉합술에서 골 시멘트를 이용한 봉합 나사 구멍 보강술)

  • Lee, Ho-Min;Tae, Suk-Kee;Park, Jeong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.237-243
    • /
    • 2010
  • Purpose: In arthroscopic rotator cuff repair, the crucial step is secure fixation of Anchor to bone. However, osteoporosis of the tuberosity is frequently encountered in old patients, and can cause insecure fixation of anchors. The Aim of our study was to introduce a technique for anchor hole augmentation with bone cement when fixation failure of an anchor occurs, and to investigate the outcome. Materials and methods: Among 223 rotator cuff repairs performed between 2005 and 2009, anchor hole augmentation with polymethylmethacrylate was performed in 15 cases (all females; mean age of 65 years: range 49~77). Bone cement was injected into the anchor hole in a thick fluid state and the procedure was repeated to make a pot-like cement mantle. The anchor was inserted into the cement mantle while the cement hardened. The outcome was investigated, on average, at 16 months (6~32). Results: Radiographs showed cystic changes of the tuberosity. On follow-up radiographs and MRI, a change in the cement mantle was not noted. The final average UCLA score was 31 (28~35); 6 had excellent, 8 good and 1 fair results (p=0.008). Age-sex matched Constants score was 90 (74~98) (p=0.008). Conclusion: Anchor hole augmentation with bone cement is useful when fixation failure of an anchor is encountered due to bone atrophy. Anchor hole augmentation with bone cement does not negatively influence the outcome.

Titanium Plate Fixation for a Dehisced Sternum Following Coronary Artery Bypass Grafting: A Case Report

  • Kim, Wan-Kee;Kim, Joon-Bum;Jung, Sung-Ho;Choo, Suk-Jung;Chung, Cheol-Hyun;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.45 no.2
    • /
    • pp.127-130
    • /
    • 2012
  • Sternal dehiscence is one of the most troublesome complications following cardiac surgery. Treatment failure and consequent lethal results are very common, even with all the efforts to resolve sternal dehiscence such as removal of infectious tissue, muscle flap interposition, and sternal rewiring. We report on a case of sternal osteomyelitis following coronary artery bypass grafting that was successfully treated with wide sternal resection, titanium plate fixation, and pectoralis muscle flap interposition.

Unrecognized bony Bankart lesion accompanying a dislocated four-part proximal humerus fracture before surgery: a case report

  • Lee, Seungjin;Shin, Daehun;Hyun, Yoonsuk
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.1
    • /
    • pp.68-72
    • /
    • 2022
  • Proximal humerus fractures are the third most common fractures, totaling 4% to 5% of all fractures. Here, we present the case of a 39-year-old man with a dislocated four-part fracture of the proximal humerus with a huge bony Bankart lesion. Preoperatively, the bony Bankart lesion of the glenoid was not visualized on computed tomography scans or magnetic resonance imaging because the fracture of the proximal humerus was comminuted, displaced, and complex. It was planned for only the humerus fracture to be treated by open reduction and internal fixation using a locking plate. However, a fractured fragment remained under the scapula after reduction of the dislocated humeral head. This was mistaken for a dislocated bone fragment of the greater tuberosity and repositioning was attempted. After failure, visual confirmation showed that the bone fragment was a piece of the glenoid. After reduction and fixation of this glenoid part with suture anchors, we acquired a well-reduced fluoroscopic image. Given this case of complex proximal humerus fracture, a glenoid fracture such as a bony Bankart lesion should be considered preoperatively and intraoperatively in such cases.