• Title/Summary/Keyword: Failure of fixation

Search Result 163, Processing Time 0.024 seconds

Comparison of Fusion with Cage Alone and Plate Instrumentation in Two-Level Cervical Degenerative Disease

  • Joo, Yong-Hun;Lee, Jong-Won;Kwon, Ki-Young;Rhee, Jong-Joo;Lee, Hyun-Koo
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.4
    • /
    • pp.342-346
    • /
    • 2010
  • Objective : This study assessed the efficacy of anterior cervical discectomy and fusion (ACDF) with cage alone compared with ACDF with plate instrumentation for radiologic and clinical outcomes in two-level cervical degenerative disease. Methods : Patients with cervical degenerative disc disease from September 2004 to December 2009 were assessed retrospectively. A total of 42 patients received all ACDF at two-level cervical lesion. Twenty-two patients who underwent ACDF with cage alone were compared with 20 patients who underwent ACDF with plate fixation in consideration of radiologic and clinical outcomes. Clinical outcomes were assessed using Robinson's criteria and posterior neck pain, arm pain described by a 10 point-visual analog scale. Fusion rate, subsidence, kyphotic angle, instrument failure and the degenerative changes in adjacent segments were examined during each follow-up examination. Results : VAS was checked during each follow-up and Robinson's criteria were compared in both groups. Both groups showed no significant difference. Fusion rates were 90.9% (20/22) in ACDF with the cage alone group, 95% (19/20) in ACDF with the plate fixation group (p = 0.966). Subsidence rates of ACDF with cage alone were 31.81% (7/22) and ACDF with plate fixation were 30% (6/20) (p = 0.928). Local and regional kyphotic angle difference showed no significant difference. At the final follow-up, adjacent level disease developed in 4.54% (1/22) of ACDF with cage alone and 10% (2/20) of ACDF with plate fixation (p= 0.654). Conclusion : In two-level ACDF, ACDF with cage alone would be comparable with ACDF with plate fixation with regard to clinical outcome and radiologic result with no significant difference. We suggest that the routine use of plate and screw in 2-level surgery may not be beneficial.

Biomechanical comparison of bone staple techniques for stabilizing tibial tuberosity fractures

  • Kyu-Tae Park;Min-Yeong Lee;Hwi-Yool Kim
    • Korean Journal of Veterinary Research
    • /
    • v.63 no.3
    • /
    • pp.24.1-24.6
    • /
    • 2023
  • This study compared the biomechanical properties of bone-stapling techniques with those of other fixation methods used for stabilizing tibial tuberosity fractures using 3-dimensionally (3D)-printed canine bone models. Twenty-eight 3D-printed bone models made from computed tomography scan files were used. Tibial tuberosity fractures were simulated using osteotomy. All samples were divided into 4 groups. Group 1 was stabilized with a pin and tension-band wire; group 2, with a pin and an 8 mm-wide bone staple; group 3, with 2 horizontally aligned pins and an 8 mm-wide bone staple; and group 4 with a 10 mm-wide bone staple. Tensile force was applied with vertical distraction until failure occurred. The load and displacement were recorded during the tests. The groups were compared based on the load required to cause displacements of 1, 2, and 3 mm. The maximum failure loads and modes were recorded. The loads at all displacements in group 4 were greater than those in groups 1, 2, and 3. The loads at 1, 2, and 3 mm displacements were similar in groups 1 and 3. There was no significant difference between groups 1 and 3. Groups 1 and 4 provided greater maximum failure loads than groups 2 and 3. Failure occurred because of tearing of the nylon rope, tibial fracture, wire breakage, pin bending, and fracture around the bone staple insertion. In conclusion, these results demonstrate that the bone-stapling technique is an acceptable alternative to tension-band wire fixation for the stabilization of tibial tuberosity fractures in canine bone models.

Scapular spine base fracture with long outside-in superior or posterior screws with reverse shoulder arthroplasty

  • Eroglu, Osman Nuri;Husemoglu, Bugra;Basci, Onur;Ozkan, Mustafa;Havitcioglu, Hasan;Hapa, Onur
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.3
    • /
    • pp.141-146
    • /
    • 2021
  • Background: The purpose of the present study was to determine how long superior screws alone or in combination with posterior placement of metaglene screws protruding and penetrating into the scapular spine in reverse total shoulder arthroplasty affect the strength of the scapular spine in a fresh cadaveric scapular model. Methods: Seven fresh cadaver scapulas were allocated to the control group (short posterior and superior screws) and seven scapulars to the study group (spine base fixation with a four long screws, three with both long superior and long posterior screws). Results: The failure load was lower in the spine fixation group (long screw, 869 N vs. short screw, 1,123 N); however, this difference did not reach statistical significance (p>0.05). All outside-in long superior or superior plus posterior screws failed due to scapular spine base fracture; failures in the short screw group were due to acromion fracture. An additional posterior outside-in screw failed to significantly decrease the failure load of the acromion spine. Conclusions: The present study highlights the significance of preventing a cortical breach or an outside-in configuration when a superior or posterior screw is inserted into the scapular spine base.

Comparative analysis of proximal humerus fracture management in elderly patients: complications of open reduction and internal fixation by shoulder surgeons and non-shoulder surgeons-a retrospective study

  • Rui Claro;Bianca Barros;Carlos Ferreira;Ana Ribau;Luis Henrique Barros
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.32-38
    • /
    • 2024
  • Background: Open reduction and internal fixation (ORIF) with a locking plate is a popular surgical treatment for proximal humeral fractures (PHF). This study aimed to assess the occurrence of complications in elderly patients with PHF treated surgically using ORIF with a locking plate and to investigate the potential differences between patients treated by shoulder surgeons and non-shoulder surgeons. Methods: A retrospective study was conducted using a single-center database to identify patients aged ≥70 years who underwent ORIF for PHF between January 1, 2011, and December 31, 2021. Data on the Neer classification, follow-up, occurrence of avascular necrosis of the humeral head, implant failure, and revision surgery were also collected. Statistical analyses were performed to calculate the overall frequency of complications according to the Neer classification. Results: The rates of implant failure, avascular osteonecrosis, and revision surgery were 15.7%, 4.8%, and 15.7%, respectively. Complications were more common in patients with Neer three- and four-part fractures. Although the difference between surgeries performed by shoulder surgeons and non-shoulder surgeons did not reach statistical significance, the rate of complications and the need for revision surgery were nearly two-fold higher in the latter group. Conclusions: PHF are highly prevalent in the elderly population. However, the ORIF surgical approach, as demonstrated in this study, is associated with a considerable rate of complications. Surgeries performed by non-shoulder surgeons had a higher rate of complications and a more frequent need for revision surgery. Future studies comparing surgical treatments and their respective complication rates are crucial to determine the optimal therapeutic options. Level of evidence: III.

The Results and Complications of the C1-C2 Transarticular Screw Fixation Methods (축추-환추간 경관절 나사못 고정술 치료의 결과 및 합병증)

  • Choi, Jun-Woong;Yoon, Seung-Hwan;Park, Hyung-Chun;Park, Hyeon-Seon;Kim, Eun-Young;Ha, Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.201-206
    • /
    • 2005
  • Objective: To evaluate the accuracy and safety of C1-C2 transarticular screw insertion, we retrospectively review surgical records and postoperative radiological findings. Methods: From January 2001 to October 2003, the C1-C2 transarticular screw fixation and posterior wiring with iliac bone grafts was performed in 16 patients. 6 patients had rheumatoid arthritis which caused cervical instability, 3 patients had os odontoideum, 3 patients had type 2 odontoid process fracture, 3 patients had traumatic transverse ligament injury and 1 patients who had been managed with C1-C2 wire fixation had psoriatic arthritis. Results: Osseous fusion was documented in 15 patients(93.8%). Only one patient was recorded screw loosening because of postoperative infection. One patient had only one screw placed because of abnormal anatomical structure, one patients was breakage of a Kirschner wire, and one screw was medial location to lateral mass of C1, but clinical results was excellent and radiological instability was not noted. Conclusion: The author's experience demonstrates that C1-C2 transarticular screw fixation with wired bone graft is a safe procedure with higher fusion rate but precaution is needed to avoid the neural damage, vertebral artery injury, and hardware failure.

Unilateral Augmented Pedicle Screw Fixation for Foraminal Stenosis

  • Kim, Jeong-Gyun;Jin, Yong-Jun;Chung, Sang-Ki;Kim, Ki-Jeong;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.1
    • /
    • pp.5-10
    • /
    • 2009
  • Objective: The purpose of this study is to evaluate the effectiveness of unilateral decompression and pedicle screw fixation for the unilateral symptomatic foraminal stenosis. Methods: The study group comprises consecutive 16 patients who underwent unilateral decompression and bone cement augmented pedicle screw fixation from May 2003 to January 2006. The patients were evaluated by visual analog scale (VAS) for pain and the scoring system of the Japanese Orthopedic Association (JOA) for low back pain. The result of surgery was also evaluated with McNab's classification. Excellent or good outcome was considered as successful. The patients were followed at postoperative 1 month, 3 month, 6 month, and 1 year with standing AP and lateral films. Results: The average VAS and JOA score of the 16 patients were 7.8(range, 6-9) and 5.8(range, 3 - 10) before surgery and 2.2(range, 0 - 5)and 12.3(range, 9 - 15) at the time of last follow up. Both VAS and JOA score improved significantly after the surgery (p<0.05, t-test). All patients improved after the operation and no revision surgery was required. No metal failure or pseudoarthrosis was observed during the follow-up. The success rate was 87.5%. Conclusion: Our data suggest that unilateral decompression and pedicle screw fixation for the unilateral symptomatic foraminal stenosis is an effect method for obtaining satisfactory clinical outcome. Its possible advantage is shorter operation time and reduced surgical extent. We believe that the reduced stiffness of unilateral fixation was compensated by pedicle screw augmentation and interbody fusion.

Dorsal Short-Segment Fixation for Unstable Thoracolumbar Junction Fractures

  • Kim, Kwan-Sik;Oh, Sung-Han;Huh, Ji-Soon;Noh, Jae-Sub;Chung, Bong-Sub
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.4
    • /
    • pp.249-255
    • /
    • 2006
  • Objective : This study is to evaluate the efficacy of dorsal short-segment fixation in unstable thoracolumbar junction fractures. Methods : The cases of 20 patients who underwent dorsal short-segment fixation were reviewed retrospectively. Clinical outcomes were analysed using Sonntag's pain level, work status, and neurological scale according to the modified Frankel classification. Radiological outcomes were analysed using Mumford's anterior body compression[%], canal compromise ratio, and Cobb's kyphotic angle. Results : At the latest clinical follow-up [average=14.6 months]. there were 19 [95.0%] in group I and 1 patient [5.0%] in II in pain level. The postoperative work status were 17 [85.0%] in group I, 2 patients [10.0%] in II, and 1 patient [5.0%] in V. Surgery brought to improve the neurologic status. In success group [19 cases, 95%], the average canal compromise ratio was reduced from 0.57 [${\pm}0.07$] to 0.05 [${\pm}0.08$] [P<005], the average anterior body compression [%] was reduced from 41% [${\pm}17$] to 18% [${\pm}14$] [P<0.05], and the average preoperative kyphotic angle was $20.0^{\circ}$ [${\pm}9.0$], and corrected to $5.7^{\circ}$ [${\pm}7.1$] postoperatively, and progressed to $7.8^{\circ}$ [${\pm}6.2$] at the latest follow-up. There was a case of implantation failure in an elderly osteoporotic patient. Conclusion : Although there are limitations in the patient number and follow-up period, the present study favors dorsal short-segment fixation for selective cases in unstable thoracolumbar junction fractures.

Complications after Surgical Correction of Hallux Valgus (무지 외반증 교정 수술 후 합병증)

  • Bae, Su-Young;Lee, Oei-Jong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.2
    • /
    • pp.50-54
    • /
    • 2017
  • The goal of surgical correction for hallux valgus is to achieve a painless, shoe-wearable, and relatively straight toe with a balanced joint motion that results in aesthetically and functionally satisfactory toe. To date, there has not been a consensus on the ultimate surgical procedure for hallux valgus correction. Unfortunately, such a consensus may be difficult since it is not uncommon to encounter complications after hallux valgus correction. Postoperative soft tissue complications include difficult wound healing, infection, hypertrophy, or pain of the scar, joint stiffness, and tendon or sensory nerve damage. Postoperative bony complications include malunion, nonunion, failure of fixation, failure of angle correction, recurred deformity, osteomyelitis, and failure of balance between the metatarsal heads. Herein, we review common complications after surgical correction of hallux valgus, such as stiff joint, bony complications, recurrence of the deformity, and hallux varus.

Ankle Arthrodesis Using Auto Fibula Bone Graft: Two Cases Report (자가 비골이식술을 이용한 족관절 유합술: 2예 보고)

  • Yi, Chang-Ho;Yoon, Won-Sik;Oh, Jin-Rok
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.2
    • /
    • pp.102-106
    • /
    • 2011
  • Recently, development and improvement in joint replacement therapy, the need for arthrodesis has been decreasing. However, result of joint replacement is not always satisfactory, and most cases are rather indicative to ankle arthrodesis than ankle replacement. Often, ankle arthrodesis can be more beneficial salvage method to treat cases with failure in joint replacement therapy, talar avascular necrosis with massive bone defect, talus fracture with severe comminution and bone defect and ankle dislocation. In cases with large bone defect that need to be treated with ankle arthrodesis using internal fixation, it is difficult to fill the defect with conventional auto-iliac bone or all-bone graft. Thus, we make a report on our experience in treating 2 cases with ankle arthrodesis using auto-fibular bone graft and plate fixation.

Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation (경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향)

  • Kim, Keun Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF