• Title/Summary/Keyword: Failure location

Search Result 601, Processing Time 0.028 seconds

Evaluation of the Finite Element Modeling of Spot-Welded Region for Crash Analysis (충돌해석에서의 점용접부 모델링에 따른 하중특성 평가)

  • Song, Jung-Han;Huh, Hoon;Kim, Hong-Gee;Kim, Sung-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.174-183
    • /
    • 2006
  • The resistance spot-welded region in most current finite element crash models is characterized as a rigid beam at the location of the welded spot. The region is modeled to fail with a failure criterion which is a function of the axial and shear load at the rigid beam. The role of this rigid beam is simply to transfer the load across the welded components. The calculation of the load acting on the rigid beam is important to evaluate the failure of the spot-weld. In this paper, numerical simulation is carried out to evaluate the calculation of the load at the rigid beam. The load calculated from the precise finite element model of the spot-welded region considering the residual stress due to the thermal history during the spot welding procedure is regarded as the reference value and the value of the load is compared with the one obtained from the spot-welded model using the rigid beam with respect to the element size, the element shape and the number of imposed constraints. Analysis results demonstrate that the load acting on the spot-welded element is correctly calculated by the change of the element shape around the welded region and the location of welded constrains. The results provide a guideline for an accurate finite element modeling of the spot-welded region in the crash analysis of vehicles.

A Study on Automatic Switching System for Fault Locator (고장점 표정반 자동절체 시스템에 대한 연구)

  • Park, Yong-Bum;Lho, Young-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8927-8932
    • /
    • 2015
  • A directional feeding method at the railway transformer is applied for supplying the power to the electric railway substations, and the pre-installed facilities with common feeder are utilized in preparation for the failure of feeding system and in finding a fault location in case that the catenary failure occurs. However, it is some difficulty in finding the fault location since there is an interface problem with the facilities when the supplying power system operates. In this paper, Auto Fault Locator Transfer Drive System (ALTDS) is designed to search for the fault location efficiently, and the measuring data are obtained and compared with the KORAIL standards. Further, the ground connection test is accomplished 24 times as the verification method, and it is shown that the methodology provides better performance than the existing traditional one.

Cumulative damage in RC frame buildings - The 2017 Mexico earthquake case

  • Leonardo M. Massone;Diego Aceituno;Julian Carrillo
    • Advances in Computational Design
    • /
    • v.8 no.1
    • /
    • pp.13-36
    • /
    • 2023
  • The Puebla-Morelos Earthquake (Mw 7.1) occurred in Mexico in 2017 causing 44 buildings to collapse in Mexico City. This work evaluates the non-linear response of a 6-story reinforced concrete (RC) frame prototype model with masonry infill walls on upper floors. The prototype model was designed using provisions prescribed before 1985 and was subjected to seismic excitations recorded during the earthquakes of 1985 and 2017 in different places in Mexico City. The building response was assessed through a damage index (DI) that considers low-cycle fatigue of the steel reinforcement in columns of the first floor, where the steel was modeled including buckling as was observed in cases after the 2017 earthquake. Isocurves were generated with 72 seismic records in Mexico City representing the level of iso-demand on the structure. These isocurves were compared with the location of 16 collapsed (first-floor column failure) building cases consistent with the prototype model. The isocurves for a value greater than 1 demarcate the location where fatigue failure was expected, which is consistent with the location of 2 of the 16 cases studied. However, a slight increase in axial load (5%) or decrease in column cross-section (5%) had a significant detrimental effect on the cumulated damage, increasing the intensity of the isocurves and achieving congruence with 9 of the 16 cases, and having the other 7 cases less than 2 km away. Including column special detailing (tight stirrup spacing and confined concrete) was the variable with the greatest impact to control the cumulated damage, which was consistent with the absence of severe damage in buildings built in the 70s and 80s.

A Study On Balance Factors for the Sustainable Growth of Technology-Based Companies: Focusing on the Case of Daedeok Cluster Successful and Unsuccessful Companies (기술기반기업의 지속적 성장을 위한 균형요인 연구: 대덕클러스터 성공실패 사례 중심으로)

  • Kyeongsik Yoo;Heungsik Kang;Jaeman Yoon;Taekeun Kim
    • Industry Promotion Research
    • /
    • v.9 no.3
    • /
    • pp.87-100
    • /
    • 2024
  • This study approached the factors affecting companies's sustainable growth by overcoming the valley of death after starting a business from the perspective of technology, market, location, cluster, and INC model, and conducted a case study on success and failure companies in Daedeok Cluster to explore the adequacy and suitability of the main factors of previous studies. The results of this study suggest that location accessibility-based collaboration between innovators is important for the growth of companies in the cluster, and balanced growth such as innovative ideas, market needs, and capability to meet needs is necessary for companies' products and services to create innovative value in the market. This study is worth in that it presents factors for sustainable corporate growth through the analyses of success and failure cases for companies in the Daedeok Cluster. In addition, the research is successful in that it proposed a policy support plan based on collaboration among companies to foster companies in the cluster.

Patterns of failure and prognostic factors in resected extrahepatic bile duct cancer: implication for adjuvant radiotherapy

  • Koo, Tae Ryool;Eom, Keun-Yong;Kim, In Ah;Cho, Jai Young;Yoon, Yoo-Seok;Hwang, Dae Wook;Han, Ho-Seong;Kim, Jae-Sung
    • Radiation Oncology Journal
    • /
    • v.32 no.2
    • /
    • pp.63-69
    • /
    • 2014
  • Purpose: To find the applicability of adjuvant radiotherapy for extrahepatic bile duct cancer (EBDC), we analyzed the pattern of failure and evaluate prognostic factors of locoregional failure after curative resection without adjuvant treatment. Materials and Methods: In 97 patients with resected EBDC, the location of tumor was classified as proximal (n = 26) and distal (n = 71), using the junction of the cystic duct and common hepatic duct as the dividing point. Locoregional failure sites were categorized as follows: the hepatoduodenal ligament and tumor bed, the celiac artery and superior mesenteric artery, and other sites. Results: The median follow-up time was 29 months for surviving patients. Three-year locoregional progression-free survival, progression-free survival, and overall survival rates were 50%, 42%, and 52%, respectively. Regarding initial failures, 79% and 81% were locoregional failures in proximal and distal EBDC patients, respectively. The most common site was the hepatoduodenal ligament and tumor bed. In the multivariate analysis, perineural invasion was associated with poor locoregional progression-free survival (p = 0.023) and progression-free survival (p = 0.012); and elevated postoperative CA19-9 (${\geq}37U/mL$) did with poor locoregional progression-free survival (p = 0.002), progression-free survival (p < 0.001) and overall survival (p < 0.001). Conclusion: Both proximal and distal EBDC showed remarkable proportion of locoregional failure. Perineural invasion and elevated postoperative CA19-9 were risk factors of locoregional failure. In these patients with high risk of locoregional failure, adjuvant radiotherapy could be considered to improve locoregional control.

Strengthening Effect of Reinforced Concrete Beams Strengthened with NSM CFRP Reinforcements and Various Reinforcement Details (다양한 보강상세를 갖는 CFRP로 표면매립 보강된 철근콘크리트 보의 보강효과)

  • Jung, Woo-Tai;Park, Young-Hwan;Park, Jong-Sup;Kim, Chul-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.781-790
    • /
    • 2011
  • This paper contains the experimental results on strengthening effect of RC beams strengthened with NSM CFRP reinforcement and various strengthening details. A total of 14 beams have been tested to analyze strengthening effects of NSMR with various reinforcement details. Variables were cross-sectional shape of CFRP reinforcements, strengthening areas, grooves the number and location etc. Test results revealed that failure modes of NSMR showed two types. One was bond failure at interface between concrete and filler and the other was CFRP rupture. Also, failure mode of specimens with two grooves occurred premature bond failure because of superposition of failure surfaces at concrete around grooves. failure mode of MI specimens considered the equivalent section have changed bond failure to CFRP rupture and CFRP efficiency has improved 83% to 100%.

Diagonal Tension Failure Model for RC Slender Beams without Shear Reinforcement Based on Kinematical Conditions (I) - Development

  • You, Young-Min;Kang, Won-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.6
    • /
    • pp.7-15
    • /
    • 2007
  • A mechanical model was developed to predict the behavior of point-loaded RC slender beams (a/d > 2.5) without stirrups. It is commonly accepted by most researchers that a diagonal tension crack plays a predominant role in the failure mode of these beams, but the failure mechanism of these members is still debatable. In this paper, it was assumed that diagonal tension failure was triggered by the concrete cover splitting due to the dowel action at the initial location of diagonal tension cracks, which propagate from flexural cracks. When concrete cover splitting occurred, the shape of a diagonal tension crack was simultaneously developed, which can be determined from the principal tensile stress trajectory. This fictitious crack rotates onto the crack tip with load increase. During the rotation, all forces acting on the crack (i.e, dowel force of longitudinal bars, vertical component of concrete tensile force, shear force by aggregate interlock, shear force in compression zone) were calculated by considering the kinematical conditions such as crack width or sliding. These forces except for the shear force in the compression zone were uncoupled with respect to crack width and sliding by the proposed constitutive relations for friction along the crack. Uncoupling the shear forces along the crack was aimed at distinguishing each force from the total shear force and clarifying the failure mechanism of RC slender beams without stirrups. In addition, a proposed method deriving the dowel force of longitudinal bars made it possible to predict the secondary shear failure. The proposed model can be used to predict not only the entire behavior of point-loaded RC slender shear beams, but also the ultimate shear strength. The experiments used to validate the proposed model are reported in a companion paper.

A Spatial Location Analysis of the First Shops of Foodservice Franchise in Seoul Metropolitan City (서울시지역 외식산업 프랜차이즈 1호점의 공간입지분석)

  • Lee, Young-Hee
    • Journal of the Korean Geographical Society
    • /
    • v.44 no.4
    • /
    • pp.532-543
    • /
    • 2009
  • The foodservice franchise is preferred by the founders who inaugurate a business enterprise, because it is not difficult to convert into money more than other private enterprise. The success or failure of the foodservice franchise depends 80 percent on its location. Therefore, this research aimed to study the location factors of the first shops of foodservice franchise in Seoul through the analyses of nearest neighborhood effect and statistical relationship between variables. According to there results, the location characteristics of the first shops of foodservice franchise are summarized as in the following three items. First, the spatial distribution pattern of the first shops is a clustered type. Second, the first shops relate to the 15 variables which are the number of financial facilities, the number of business service offices, and the number of hotels and restaurants, etc. Third, the main location factor of the first shops is the number of financial facilities. In conclusion, it is estimated that Gangnam-gu and Jung-gu might be good for the location of the first shops of foodservice franchise in Seoul, because these two places have many financial buildings.

Repeated failure of implants at the same site: a retrospective clinical study

  • Kang, Dong-Woo;Kim, So-Hyun;Choi, Yong-Hoon;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.27.1-27.9
    • /
    • 2019
  • Background: Implants are becoming the first choice of rehabilitation for tooth loss. Even though they have a high success rate, failures still occur for many reasons. The objective of this study is to analyze the reasons for recurring failure at the same site and the results of re-implantation. Methods: Thirteen patients (11 males and 2 females, mean age 60 ± 9.9 years) who experienced implant surgery failure at the same site (same tooth extraction area) two or more times in the Department of Oral and Maxillofacial Surgery, Seoul National University Bundang Hospital, between 2004 and 2017 were selected. The medical records on a type, sites, diameter, and length of implants; time and estimated cause of failure; and radiographs were reviewed. Data were collected and analyzed retrospectively, and the current statuses were evaluated. Results: A total of 14 implants experienced failure in the same site more than two times. Twelve implants were placed in the maxilla, while 2 implants were placed in the mandible. The maxillary molar area was the most common site of failure (57.1%), followed by the mandibular molar, anterior maxilla, and premolar areas (14.3% each). The first failure occurred most commonly after prosthetic treatment (35.7%) with an average period of failure of 3.8 months after loading. Ten cases were treated as immediate re-implantation, while the other 4 were delayed reimplantation after an average of 3.9 months. The second failure occurred most commonly after prosthetic treatment (42.9%), with an average of 31 months after loading; during the healing period (42.9%); and during the ongoing prosthetic period (14.3%). In 3 cases (21.4%), the treatment plan was altered to an implant bridge, while the other 11 cases underwent another implant placement procedure (78.6%). Finally, a total of 9 implants (64.3%) survived, with an average functioning period of 60 months. Conclusions: Implants can fail repeatedly at the same site due to overloading, infection, and other unspecified reasons. The age and sex of the patient and the location of implant placement seem to be associated with recurring failure. Type of implant, bone augmentation, and bone materials used are less relevant.

A review paper about experimental investigations on failure behaviour of non-persistent joint

  • Shemirani, Alireza Bagher;Haeri, Hadi;Sarfarazi, Vahab;Hedayat, Ahmadreza
    • Geomechanics and Engineering
    • /
    • v.13 no.4
    • /
    • pp.535-570
    • /
    • 2017
  • There are only few cases where cause and location of failure of a rock structure are limited to a single discontinuity. Usually several discontinuities of limited size interact and eventually form a combined shear plane where failure takes place. So, besides the discontinuities, the regions between adjacent discontinuities, which consist of strong rock and are called material or rock bridges, are of utmost importance for the shear strength of the compound failure plane. Shear behaviour of persistent and non-persistent joint are different from each other. Shear strength of rock mass containing non-persistent joints is highly affected by mechanical behavior and geometrical configuration of non-persistent joints located in a rock mass. Therefore investigation is essential to study the fundamental failures occurring in a rock bridge, for assessing anticipated and actual performances of the structures built on or in rock masses. The purpose of this review paper is to present techniques, progresses and the likely future development directions in experimental testing of non-persistent joint failure behaviour. Experimental results showed that the presence of rock bridges in not fully persistent natural discontinuity sets is a significant factor affecting the stability of rock structures. Compared with intact rocks, jointed rock masses are usually weaker, more deformable and highly anisotropic, depending upon the mechanical properties of each joint and the explicit joint positions. The joint spacing, joint persistency, number of rock joint, angle of rock joint, length of rock bridge, angle of rock bridge, normal load, scale effect and material mixture have important effect on the failure mechanism of a rock bridge.