• 제목/요약/키워드: Failure line

검색결과 833건 처리시간 0.032초

Analysis of Cause of Excavator Safety Accidents according to the Accident Case Study (중대재해사례를 통한 굴삭기 안전사고 원인분석)

  • Seo, Jong-Min;Han, Kap-Kyu;Lim, Ji-Young;Kim, Sun-Kuk
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 한국건설관리학회 2007년도 정기학술발표대회 논문집
    • /
    • pp.450-454
    • /
    • 2007
  • In line with the construction projects, which have been increasingly getting larger and complex, safety accident has been on the rise, particularly those in association with the construction equipment. In a bid to prevent the safety accident, it's needed to analyze the cause of such accidents. The thesis was intended to identify the cause of safety accident by reviewing the cases of construction disaster complied by Korea Occupational Safety and Health Agency. The cases subject to study were limited to the accident by excavator. Summarizing the study is as follows. 1) Among the cause of accidents caused by excavator were, in order of high frequency, being caught in equipment or machine, falling, being crashed or bumped. 2) Among the causes of accident were, in order of high frequency, worker's unauthorized presence within the range of equipment operation. inappropriate use, failure of equipment inspection prior to starting work and inappropriate work method. The study is highly expected to pave the foundation for further study as well as to make commitment to mitigating the safety accident.

  • PDF

The Development of Lightning Outage Rate Calculation Program (송전선로 뇌 사고율 예측계산 프로그램 개발)

  • Kang, Yeon-Woog;Shim, Eung-Bo;Kweon, Dong-Jin;Kwak, Ju-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제22권10호
    • /
    • pp.118-125
    • /
    • 2008
  • The outages of transmission lines give big damages to the industrial world Lightning outages occupy above 50[%] among the outages of transmission lines. To decrease the lightning outage rates, it is necessary to try countermeasures considering economical points. For the lightning protection of power transmission lines, it is very important to accurately predict the lightning outage rate because the reliability criterion for transmission line is normally specified as the number of flashovers per 100[km] per year. The phenomenon of an insulator flashover by a lightning stroke is a very complex electromagnetic event. And to calculate the lightning outage rates of transmission lines, so many calculation should be repeated because there are many overhead lines and power lines. Therefore it is necessary to develope a program for it. In this paper, we briefly introduce the basic concept for lightning outage calculation algorithm and the program.

Development of electric safety control system for incapable operation of ELB and MCB using the low voltage distribution line (저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 전기안전 제어장치 개발)

  • Kwak, Dong-Kurl;Shin, Mi-Young;Jung, Do-Young;Kim, Hyo-Jin;Baek, Seong-Hyun;Choi, Byung-Seub
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.371-372
    • /
    • 2007
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is Earth Leakage Circuit Breaker(ELB) and Molded_case Circuit Breaker (MCB), of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF

Study on Analysis of Operating Characteristics of Motor Block While KTX is Moving at Neutral Section of Kyung-Bu High Speed Line (경부고속선 절연구간에서 KTX 운행중 모터블럭의 동작특성 분석)

  • Choi, Chang Hyun;Lho, Young Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제64권10호
    • /
    • pp.1523-1527
    • /
    • 2015
  • Traction power is supplied by three-phase alternating current of 154 kV power grid and electric trains are operated on single phase feeding system. It becomes important to use all the three phases equally and convert them into two-phase electric power (90 degree phase rotation) for traction supply. This is achieved by special transformer from the adjacent traction substation which is separated by a neutral section. Neutral section locations are in front of the substation and between the two substations. The first stage of the Seoul-Busan high-speed railway, design curve radius is larger than 7,000 m and the greatest slope is 25‰. The railway track conditions are evaluated as good enough to install a neutral section at the first stage, but a few factors of coasting operation of the train should be considered at the second stage of Seoul-Busan high-speed railway. The neutral section was located at Kim-cheon substation, which made some neutral section problems produced by the operating train, and the neutral section was moved about 1.5 km to the south toward Dong Dae-gu station due to the track operation condition. Some of the trains which stopped at the existing Kim-cheon Gu-mi station produced another motor block failure after moving the neutral section. In this paper, power quality, system performance and track condition, etc. are suggested to solve the problems.

High Performance ESD/Surge Protection Capability of Bidirectional Flip Chip Transient Voltage Suppression Diodes

  • Pharkphoumy, Sakhone;Khurelbaatar, Zagarzusem;Janardhanam, Valliedu;Choi, Chel-Jong;Shim, Kyu-Hwan;Daoheung, Daoheung;Bouangeun, Bouangeun;Choi, Sang-Sik;Cho, Deok-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권4호
    • /
    • pp.196-200
    • /
    • 2016
  • We have developed new electrostatic discharge (ESD) protection devices with, bidirectional flip chip transient voltage suppression. The devices differ in their epitaxial (epi) layers, which were grown by reduced pressure chemical vapor deposition (RPCVD). Their ESD properties were characterized using current-voltage (I-V), capacitance-voltage (C-V) measurement, and ESD analysis, including IEC61000-4-2, surge, and transmission line pulse (TLP) methods. Two BD-FCTVS diodes consisting of either a thick (12 μm) or thin (6 μm), n-Si epi layer showed the same reverse voltage of 8 V, very small reverse current level, and symmetric I-V and C-V curves. The damage found near the corner of the metal pads indicates that the size and shape of the radius governs their failure modes. The BD-FCTVS device made with a thin n- epi layer showed better performance than that made with a thick one in terms of enhancement of the features of ESD robustness, reliability, and protection capability. Therefore, this works confirms that the optimization of device parameters in conjunction with the doping concentration and thickness of epi layers be used to achieve high performance ESD properties.

Surgical management of male genital lymphedema: A systematic review

  • Aulia, Indri;Yessica, Eva Chintia
    • Archives of Plastic Surgery
    • /
    • 제47권1호
    • /
    • pp.3-8
    • /
    • 2020
  • Genital lymphedema (GL) is an uncommon and disabling disease that manifests as enlargement of the genital region resulting from the disturbance of lymphatic drainage. Although conservative treatment such as decompression is typically the first-line approach, surgical intervention has been shown to be effective in certain cases. This study aimed to systematically review studies evaluating available surgical alternatives for the treatment of male GL. A systematic search strategy using keyword and subject headings was applied to PubMed, Scopus, EMBASE, and Cochrane Library in May 2019. Studies investigating various surgical techniques to treat penile and scrotal lymphedema were included. The potential risk of bias of included trials was evaluated using the methodological index for non-randomized studies (MINORS). In total, 13 studies met the inclusion criteria, nine of which were determined to be high-quality. The average MINORS score was 12.45 for studies involving excision and 14 for studies involving lymphovenous anastomosis (LVA). The most common reason for a low score was a failure to describe the inclusion criteria. Recurrence of lymphedema during follow-up was reported in four studies involving excision and in no studies involving LVA. In general, the quality of the included literature was considered to be fair. Although surgical intervention might not always prevent the recurrence of lymphedema, all of the studies reported improved quality of life after the procedure. This study could be used as the basis for evidence-based guidelines to be applied in clinical practice for managing male GL.

Easy and Safe Catheterization of the Innominate Vein (무명정맥의 쉽고 안전한 삽관)

  • 이흥섭;조창욱
    • Journal of Chest Surgery
    • /
    • 제29권12호
    • /
    • pp.1401-1404
    • /
    • 1996
  • Central venous line insertion is an essential procedure in a cardiac operation. For this, percuteneous Insertion is usually done in the internal jugular vein or the subclavian vein. However, this method can create such complications as pneumothorax and hemothorax, and repeated failure in inserting the cathet r, especially in infant and child patients, can waste excessive time. Consequently, in our hospital, catheterization of the innominate vein was done after the completion of sternotomy in the cardiac operation of infant and child patients weighing under 1 Okg. During operation, the catheter was placed in the left atrium through the foramen ovate or pulmonary artery to be used for pressure monitoring. When the patient's hemodynamic became stabilized, the catheter was withdrawn to either the right atrium or superior vena casa to be used as the channel for fluid replacement or drug administration. In our hospital, this procedure has been used in 96 cases since 1989. No complications such as pneumothorax and hemothorax occilrred, and neither bleeding after the removal of the catheter was seen.

  • PDF

Comparison of the Indications and Treatment Results of Burr-Hole Drainage at the Maximal Thickness Area versus Twist-Drill Craniostomy at the Pre-Coronal Point for the Evacuation of Symptomatic Chronic Subdural Hematomas

  • Kim, Gi Hun;Kim, Bum-Tae;Im, Soo-Bin;Hwang, Sun-Chul;Jeong, Je Hoon;Shin, Dong-Seong
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권3호
    • /
    • pp.243-247
    • /
    • 2014
  • Objective : To analyze the clinical data and surgical results from symptomatic chronic subdural hematoma (CSDH) patients who underwent burr-hole drainage (BHD) at the maximal thickness area and twist-drill craniostomy (TDC) at the precoronal point. Methods : We analyzed data from 65 symptomatic CSDH patients who underwent TDC at the pre-coronal point or BHD at the maximal thickness area. For TDC, we defined the pre-coronal point to be 1 cm anterior to the coronal suture at the level of the superior temporal line. TDC was performed in patients with CSDH that extended beyond the coronal suture, as confirmed by preoperative CT scans. Medical records, radiological findings, and clinical performance were reviewed and analyzed. Results : Of the 65 CSDH patients, 13/17 (76.4%) with BHD and 42/48 (87.5%) with TDC showed improved clinical performance and radiological findings after surgery. Catheter failure was seen in 1/48 (2.4%) cases of TDC. Five patients (29.4%) in the BHD group and four patients (8.33%) in the TDC group underwent reoperations due to remaining hematomas, and they improved with a second operation, BHD or TDC. Conclusion : Both BHD at the maximal thickness area and TDC at the pre-coronal point are safe and effective drainage methods for symptomatic CSDHs with reasonable indications.

The Development of New GO-FLOW Methodology Using the Reliability of System Components (시스템 구성요소의 신뢰도를 기반으로 하는 새로운 GO-FLOW기법 개발)

  • Byun, Yoon-Sup;Lee, Ju-Yeong;Hwang, Kyu-Suk
    • Journal of the Korean Institute of Gas
    • /
    • 제16권4호
    • /
    • pp.8-15
    • /
    • 2012
  • The GO-FLOW methodology is capable of assessing system reliability. It models the system into a GO-FLOW chart with signal lines and operators and assesses the reliability of system by assessing the GO-FLOW chart sequential. But, as it models one component of system into several operators, the GO-FLOW chart which is different from the system flow diagram be modeled. Also, as it models the real operation time into "time point", it is hard to assess the reliability change according to the real operation time. Therefore, in this paper, the new GO-FLOW methodology which use the function(success/failure) of system components has been developed. It can assess the successful operating probability of system, regardless of the operating status of components. As it models one component of system into one operator, the GO-FLOW chart which is similar the system flow diagram can be modeled. Also, it is able to easily assess the successful probability of system according to the real operation time using the time in the operators.

Effect of Paint Baking on the Strength and Failure of Spot Welds for 780 TRIP Steels (780 MPa급 TRIP강의 저항 점용접부 강도 및 파단에 미치는 Paint Baking의 영향)

  • Son, Jong-Woo;Nam, Dae-Geun;Kim, Dong-Cheol;Park, Yeong-Do
    • Journal of Welding and Joining
    • /
    • 제28권2호
    • /
    • pp.66-73
    • /
    • 2010
  • Conventional fracture test of resistance spot weld had been performed without consideration of paint baking process in automobile manufacturing line. This study was aim to investigate the effect of paint baking on fracture mode and load carrying capacity in fracture test for resistance spot welded 780TRIP steels. With paint baking cycle after resistance spot welds, peel tests and microhardness were conducted on the as-welded and baked samples. Resistance spot welds in AHSS (Advanced High Strength Steels) are prone to display partial interfacial fractures during fracture test or vehicle crash. Baking cycle increased the load-carrying capacity of the resistance spot welded samples and improved the fracture appearance from partial to full button fracture for the L-type peel tests. Specially, the differences in fracture appearance are apparent when the nugget size of spot welds is small enough to produce the partial interfacial fracture. The comparison of macrohardness and microstructure between as-welded and baked samples showed that there are no large difference in change the fracture mode. However, the results of the instrumented indentation test suggested that fusion zone and HAZ of baked sample have less tensile and yield strength and proves that the tempering effects are applied and enhanced the resistance to fracture on welds with application of baking cycle.