• Title/Summary/Keyword: Failure line

Search Result 832, Processing Time 0.028 seconds

Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function (화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구)

  • Ko, Wan-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • The purpose of this study is to develop an earth leakage alarm circuit breaker, equipped with a leakage alarming function (JER-E2S, ETECKOREA Co., Korea), and to analyze its characteristics. The developed mechanism is exclusively used for single-phase and 220 V circuits, with a rated current of 32 A, 20 A, 20 A (for restrooms), 16 A, etc. It satisfies all characteristics of existing earth leakage circuit breakers (ELB). If a fire current, which is a resistive leakage current (Igr), flows through an electric line, the device detects the leakage current in real time and warns against the leakage through a blinking LED lamp. Since the developed device displays a tolerance to a capacitative leakage current (Igc) that inevitably occurs in LED lamps, communication devices, etc., it ensures a stable power supply. In addition, the earth leakage alarm circuit breaker protects against power failure due to a momentary ground fault. Therefore, it can supply power without the risk of the circuit breaker malfunctioning due to a momentary ground fault caused by water droplets, leaves, etc. Moreover, with a standby power of less than 0.1 W, the developed earth leakage alarm circuit breaker exhibits a power saving performance that is 3~8 times greater than that of other ELBs. Installation of approximately 10 earth leakage alarm circuit breakers in one apartment household, with an area of 120 ㎡, can save 2~5 kWh per month. Therefore, the developed earth leakage alarm breaker not only satisfies the characteristics of existing earth leakage breakers, but also exhibits outstanding power supply quality since it has the functions of electric fire prevention and malfunction prevention. Therefore, this device can innovatively contribute to electric fire prevention.

Effects of implant alignment and load direction on mandibular bone and implant: finite element analysis (임플란트 배열과 하중 방향이 임플란트와 치조골에 미치는 유한요소 응력분석)

  • Chung, Hyunju;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.176-182
    • /
    • 2020
  • Purpose: To evaluate the effects of load direction, number of implants, and alignment of implant position on stress distribution in implant, prosthesis, and bone tissue. Materials and Methods: Four 3D models were made to simulate posterior mandible bone block: two implants and 3-unit fixed dental prosthesis (FDP) with a pontic in the center (model M1), two implants and 3-unit FDP with a cantilever pontic at one end (model M2), FDP supported by three implants with straight line placement (model M3) and FDP supported by three implants with staggered implant configuration (model M4). The applied force was 120 N axially or 120 N obliquely. Results: Peak von Mises stresses caused by oblique occlusal force were 3.4 to 5.1 times higher in the implant and 3.5 to 8.3 times higher in the alveolar bone than those stresses caused by axial occlusal force. In model M2, the connector area of the distal cantilever in the prosthesis generated the highest von Mises stresses among all models. With the design of a large number of implants, low stresses were generated. When three implants were placed, there were no significant differences in the magnitude of stress between staggered arrangement and straight arrangement. Conclusion: The effect of staggering alignment on implant stress was negligible. However, the number of implants had a significant effect on stress magnitude.

Failure Analysis of Ferroelectric $(Bi,La)_4Ti_3O_{12}$ Capacitor in Fabricating High Density FeRAM Device (고밀도 강유전체 메모리 소자 제작 시 발생하는 $(Bi,La)_4Ti_3O_{12}$ 커패시터의 불량 분석)

  • Kim, Young-Min;Jang, Gun-Eik;Kim, Nam-Kyeong;Yeom, Seung-Jin;Hong, Suk-Kyoung;Kweon, Soon-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.257-257
    • /
    • 2007
  • 고밀도 FeRAM (Ferroe!ectric Random Access Memory) 소자를 개발하기 위해서는 강유전체 물질을 이용한 안정적인 스텍형의 커패시터 개발이 필수적이다. 특히 $(Bi,La)_4Ti_3O_{12}$ (BLT) 강유전체 물질을 이용하는 경우에는 낮은 열처리 온도에서도 균질하고 높은 값의 잔류 분극 값을 확보하는 것이 가장 중요한 과제 중의 하나이다. 불행히도, BLT 물질은 a-축으로는 약 $50\;{\mu}C/cm^2$ 정도의 높은 잔류 분극 값을 갖지만, c-축 방향으로는 $4\;{\mu}C/cm^2$ 정도의 낮은 잔류 분극 값을 나타내는 동의 강한 비등방성 특성을 보인다. 따라서 BLT 박막에서 각각 입자들의 크기 및 결정 방향성을 세밀하게 제어하는 것은 무엇보다 중요하다. 본 연구에서는 16 Mb의 1T/1C (1-transistor/1-capacitor) 형의 FeRAM 소자를 BLT 박막을 적용하여 제작하였다. 솔-젤 (sol-gel) 용액을 이용하여 스핀코팅법으로 BLT 박막을 증착하고, 후속 열처리 공정을 RTP (rapid thermal process) 공정을 이용하여 수행하였다. 커패시터의 하부 전극 및 상부 전극은 각각 Pt/IrOx/lr 및 Pt을 적용하였다. 반응성 이온 에칭 (RIE: reactive ion etching) 공정을 이용하여 커패시터를 형성시킨 후, 32k-array (unit capacitor: $0.68\;{\mu}m$) 패턴에서 측정한 스위칭 분극 (dP=P*-P^) 값은 약 $16\;{\mu}C/cm^2$ 정도이고, 웨이퍼 내에서의 균일도도 2.8% 정도로 매우 우수한 특성을 보였다. 그러나 단위 셀들의 특성을 평가하기 위하여 bit-line의 전압을 측정한 결과, 약 10% 정도의 커패시터에서 불량이 발생하였다. 그리고 이러한 불량 젤들은 매우 불규칙적으로 분포함을 확인할 수 있었다. 이러한 불량 원인을 파악하기 위하여 양호한 젤과 불량이 발생한 셀에서의 BLT 박막의 미세구조를 분석하였다. 양호한 셀의 BLT 박막 입자들은 불량한 셀에 비하여 작고 비교적 균일한 크기를 갖고 있었다. 이에 비하여 불량한 셀에서의 BLT 박막에는 과대 성장한 입자들이 존재하고 이에 따라서 입자 크기가 매우 불균질한 것으로 확인되었다. 또 이러한 과대 성장한 입자들은 거의 모두 c-축 배향성을 나타내었다. 이상의 실험 결과들로부터, BLT 박막을 이용하여 제작한 FeRAM 소자에서 발생하는 불규칙한 셀 불량의 주된 원인은 c-축 배향성을 갖는 과대 성장한 입자의 생성임을 알 수 있었다. 즉 BLT 박막을 이용하여 FeRAM 소자를 제작하는 경우, 균일한 크기의 입자 및 c-축 배향성의 입자 억제가 매우 중요한 기술적 요소임을 알 수 있었다.

  • PDF

A Study on the Durability Performance of a Receptacle for CNG Vehicles (천연가스 차량용 리셉터클의 내구성능에 관한 연구)

  • Choi, Young;Kim, Young-Min;Lee, Yong-Gyu;Lee, Jang-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.15-20
    • /
    • 2010
  • Compressed Natural Gas (CNG) buses have been supplied since the year 2000 in order to resolve severe atmospheric pollution in metropolitan area and contributed on the improvement of urban atmospheric environment. However, it is indispensible to take an adequate measure to guarantee the safety of CNG vehicles because of the possibility of huge fire accident. A receptacle, connecting device between high pressure fuel supply tank and fuel line, plays an important role in CNG supply system. In recent, leakage of CNG from receptacles has been reported. So, the concern about the security and reliability of receptacles has been arisen. Therefore, a lot of efforts to prevent leakage are invested among researchers and the durability of this component should be guaranteed despite repeated operation. This research has performed durability tests of a CNG receptacle regarding the repeated usage, extreme chattering, and continuous full flow test. Although a receptacle used for CNG vehicle satisfies validation requirements in the test results, it has been found that failure in the function of leakage prevention in a receptacle could take place in the case of prolonged exposure to high supply pressure in common quick charging environment on site.

Deployment Strategies of Cloud Computing System for Defense Infrastructure Enhanced with High Availability (고가용성 보장형 국방 클라우드 시스템 도입 전략)

  • Kang, Ki-Wan;Park, Jun-Gyu;Lee, Sang-Hoon;Park, Ki-Woong
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.15 no.3
    • /
    • pp.7-15
    • /
    • 2019
  • Cloud computing markets are rapidly growing as cost savings and business innovation are being carried out through ICT worldwide. In line with this paradigm, the nation is striving to introduce cloud computing in various areas, including the public sector and defense sector, through various research. In the defense sector, DIDC was established in 2015 by integrating military, naval, air and military computing centers, and it provides cloud services in the form of IaaS to some systems in the center. In DIDC and various future cloud defense systems, It is an important issue to ensure availability in cloud defense systems in the defense sector because system failures such as network delays and system resource failures are directly linked to the results of battlefields. However, ensuring the highest levels of availability for all systems in the defense cloud can be inefficient, and the efficiency that can be gained from deploying a cloud system can be reduced. In this paper, we classify and define the level of availability of defense cloud systems step by step, and propose the strategy of introducing Erasure coding and failure acceptance systems, and disaster recovery system technology according to each level of availability acquisition.

A Study on The Factors of Policy Change in Latecomer Nations : Through the case of Korea's renewable energy policy change (후발국의 제도 변화 요인 연구 : 한국의 신재생에너지 정책 변동 사례를 통해)

  • Yoon, Youngchul;Choung, Jae-Yong
    • Journal of Technology Innovation
    • /
    • v.27 no.2
    • /
    • pp.1-36
    • /
    • 2019
  • In line with the international community's movement to reduce greenhouse gas emission, Korea implemented FIT(Feed in Tariff) in 2002 as part of its renewable energy development project. Although the policy had shifted to full-scale RPS(Renewable Portfolio Standards) in 2012, policymakers are still seeking changes due to policy ineffectiveness. While previous studies explain sudden policy changes through external factors, recent research sheds light on internal factors in the process of policy transition. The purpose of this study is to investigate the factors that are responsible for rapidly changing policies in latecomer nations. In order to find this, we look at the case of transition from the FIT to the RPS in Korea's expansion of renewable energy policy. As a result of the research, it is confirmed that the Top-Down decision making system of Korea and the external regulatory change cause rapid policy transition. By looking at these variables, we propose useful implications for policymakers to minimize the policy failure in future policy design and evolution.

A Case Study on Earthquake-induced Deformation of Quay Wall and Backfill in Pohang by 2D-Effective Stress Analysis (2차원 유효응력 해석에 의한 지진시 포항 안벽구조물의 변형 사례 분석)

  • Kim, Seungjong;Hwang, Woong-Ki;Kim, Tae-Hyung;Kang, Gi-Chun
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.7
    • /
    • pp.15-27
    • /
    • 2019
  • The purpose of this study is to investigate the mechanism about damages occurring at quay wall and backfill in Youngilman Port during Pohang earthquake (M5.4) on November 15, 2017. In the field investigation, the horizontal displacement of the caisson occurred between 5 cm and 15 cm, and the settlement at backfill occurred higher than 10 cm. 2D-effective Stress Analysis was performed to clarify the mechanism for the damage. The input earthquake motion used acceleration ($3.25m/s^2$) measured at bedrock of Pohang habor. Based on a numerical analysis, it was found that the effective stress decreased due to the increase of excess pore pressure in the backfill ground and the horizontal displacement of the caisson occurred by about 14 cm, and the settlement occurred by about 3 cm. In backfill, the settlements occurred between 6 cm and 9 cm. This is similar to field investigation results. Also, it was found that the backfill soil was close to the Mohr-Coulomb failure line due to the cyclic loading from the effective stress path and the stress-strain behavior. It may be related to decreasing of bearing capacity induced by the reduction of effective stress caused by the increase of the excess pore water pressure.

Efficacy of Endoscopic Electrocauterization for Recurrent Posterior Epistaxis (반복되는 후방 비출혈에서 내시경 지혈술의 효과)

  • Lee, Jung Joo;Lee, Eunkyu;Ryu, Gwanghui;Seo, Min Young;Hong, Sang Duk;Kim, Hyo Yeol;Dhong, Hun-Jong;Chung, Seung-Kyu
    • Journal of Rhinology
    • /
    • v.25 no.2
    • /
    • pp.75-79
    • /
    • 2018
  • Background and Objectives: To investigate the common site of recurrent epistaxis after initial intervention such as packing and cauterization had failed and to evaluate the efficacy of surgical endoscopic electrocautery. Subjects and Method: Retrospective review of 47 patients with recurrent and uncontrolled idiopathic epistaxis between October 1995 and March 2016. All patients underwent endoscopic examination in the operating room after hospitalization. We performed electrocautery when a bleeding site was found. Results: The most common sites of bleeding were the inferior meatus (28%), sphenoethmoid recess (23%), superior septum around the olfactory cleft (13%), and the posterior end of the middle turbinate (15%). There was no serious complication during the one week after surgery. In 46 (98%) patients, refractory epistaxis was successfully controlled. One patient had recurrent epistaxis after electrocautery and underwent endoscopic sphenopalatine artery ligation. Conclusion: In patients with refractory idiopathic epistaxis after failure of first-line treatment, endoscopic examination through a surgical approach and electrocautery for suspected bleeding are effective.

Chronic Recurrent Multifocal Osteomyelitis Associated With Inflammatory Bowel Disease Successfully Treated With Infliximab

  • Kwak, Shinhyeung;Kim, Dongsub;Choi, Joon-sik;Yoon, Yoonsun;Kim, Eun Sil;Kim, Mi Jin;Yoo, So-Young;Shim, Jong Sup;Choe, Yon Ho;Kim, Yae-Jean
    • Pediatric Infection and Vaccine
    • /
    • v.29 no.2
    • /
    • pp.96-104
    • /
    • 2022
  • Chronic recurrent multifocal osteomyelitis (CRMO) is an inflammatory bone disorder presenting with sterile osteomyelitis, most often presenting in childhood. Although the etiology is understood incompletely, its association with other auto-inflammatory diseases including inflammatory bowel disease (IBD); psoriasis; Wegener's disease; arthritis; and synovitis, acne, pustulosis, hyperostosis, and osteitis (SAPHO) syndrome suggests that dysregulated innate immunity may play an important role in the pathogenesis. We report a case of a 13-year-old boy with CRMO associated with Crohn's disease (CD) successfully treated with infliximab after failure of non-steroidal anti-inflammatory drug (NSAID) treatment. He initially was diagnosed with CRMO based on symmetric and aseptic bone lesions with no fever, lack of response to antibiotic treatment, vertebral involvement, and normal blood cell counts. Despite five months of NSAID treatment, his musculoskeletal symptoms were aggravated, and he developed gastrointestinal symptoms. Finally, he was diagnosed with CRMO associated with CD. Due to the severity of symptoms, infliximab was initiated and produced symptom improvement. This case supports infliximab as another choice for treatment of bowel symptoms in addition to the bone and joint symptoms of CRMO when other first-line treatments are ineffective.

Analysis on Behavior Characteristics of Underground Facility Backfilled with Clsm According to Adjacent Excavation (CLSM으로 되메움된 지하 인프라 매설물의 근접 굴착에 따른 거동특성 분석 )

  • Seung-Kyong, You;Nam-Jae, Yu;Gigwon, Hong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.4
    • /
    • pp.101-109
    • /
    • 2022
  • This study describes the results of model experiment to analyze the effect of backfill material types on the behavior of underground facility. In the model experiment, backfill materials around the existing underground facility were applied with soil (Jumunjin standard sand) and CLSM. The displacement of underground facility was analyzed for each excavation stage considering the separation distance between the excavation surface and the backfill area based on the experimental results. When soil was applied as a backfill material, the soil on the back of the excavation surface collapsed by excavation and formed an angle of repose, and the process of slope stability was repeated at each excavation stage. In addition, the displacement of underground facility began to occur in the excavation stage that the failure line of soil passes the installation location of the underground facility. When CLSM was applied as a backfill material, there was almost no horizontal and vertical displacement of the ground regardless of the separation distance from the excavation surface even when excavation proceeded to the backfill depth. Therefore, this result showed that it can have a resistance effect against the lateral earth pressure generated and the collapse of the original ground by adjacent excavation, if a backfill material with high stiffness such as CLSM is applied.