• Title/Summary/Keyword: Failure Mode Effective Analysis

검색결과 85건 처리시간 0.027초

오류유형 영향분석(FMEA)을 적용한 수술준비 위험예방활동의 효과 (A Study on Failure Mode and Effect Analysis (FMEA) for Preoperative Risk Prevention)

  • 김창희;이미향
    • 간호행정학회지
    • /
    • 제22권5호
    • /
    • pp.415-423
    • /
    • 2016
  • Purpose: The purpose of this research was to provide patients with safe preoperative preparatory procedures by removing any risk factors from the preparatory procedures by using failure mode and effects analysis, which is a prospective risk-managing tool. Methods: This was a research design in which before and after conditions of a single group were studied, Failure mode and effects analysis were applied for the preparatory procedures done before operations. Results: The preparation omission rate before the operation decreased from 2.70% to 0.04%, and operation cancellation rate decreased from 0.48% to 0.08%. Conclusion: Failure mode and effects analysis which remove any risk factors for patients in advance of the operation is effective in preventing any negligent accidents.

신규노형 원전의 발전정지유발기기 선정을 위한 고장모드영향분석 (Failure Mode Effective Analysis for selection of Single Point Vulnerability in New type Nuclear Power Plant)

  • 현진우;염동운
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.31-36
    • /
    • 2014
  • For decreasing an unexpected shutdown of Nuclear Power Plants, Korea Hydro & Nuclear Power co.(KHNP) has developed Single Point Vulnerability(SPV) of NPPs since 2008. SPV is the equipment that cause reactor shutdown & turbine trip or more than 50% power rundown due to its malfunction. New type Nuclear Power Plants need to develop the SPV list, so performed the SPV selection for about 1 year. To develop this, Failure Mode Effect Analysis(FMEA) methods are used. As results of FMEA analysis, about 700 equipment are selected as SPV. Thereafter those are going to be applied to new type Nuclear Power Plants to enhance equipment reliability.

민감도 해석을 이용한 센서의 최적 위치 선정에 관한 연구 (A Study on Optimal Sensor Placement Using Sensitivity Analysis)

  • 손인수;이두호
    • 한국소음진동공학회논문집
    • /
    • 제21권3호
    • /
    • pp.241-247
    • /
    • 2011
  • Although intensive development continues on innovative sensor systems, there is still considerable uncertainty in deciding on the number of sensors required and their locations in order to obtain adequate information on structural behavior. This paper is concerned with the sensor locations on a beam-structure for prognostic structural health monitoring. The purpose of this study is to investigate how to determine optimal sensor placement(OSP) from the sensitivity information of a known failure mode. The sensitivity of the forced vibration response of a beam to the variation of stiffness due to a crack is calculated analytically and used to determine the optimal sensor locations for the specified failure mode. The results of this method compared with the results of different OSP methods. The results have shown that the proposed method on optimal sensor placement is very effective in structural health monitoring.

Study on mechanism of macro failure and micro fracture of local nearly horizontal stratum in super-large section and deep buried tunnel

  • Li, Shu-cai;Wang, Jian-hua;Chen, Wei-zhong;Li, Li-ping;Zhang, Qian-qing;He, Peng
    • Geomechanics and Engineering
    • /
    • 제11권2호
    • /
    • pp.253-267
    • /
    • 2016
  • The stability of surrounding rock will be poor when the tunnel is excavated through nearly horizontal stratum. In this paper, the instability mechanism of local nearly horizontal stratum in super-large section and deep buried tunnel is revealed by the analysis of the macro failure and micro fracture. A structural model is proposed to explain the mechanics of surrounding rock collapse under the action of stress redistribution and shed light on the macroscopic analytical approach of the stability of surrounding rock. Then, some highly effective formulas applied in the tunnel engineering are developed according to the theory of mixed-mode micro fracture. And well-documented field case is made to demonstrate the effectiveness and accuracy of the proposed analytical methods of mixed-mode fracture. Meanwhile, in order to make the more accurate judgment about yield failure of rock mass, a series of comprehensive failure criteria are formed. In addition, the relationship between the nonlinear failure criterion and $K_I$ and $K_{II}$ of micro fracture is established to make the surrounding rock failure criterion more comprehensive and accurate. Further, the influence of the parameters related to the tension-shear mixed-mode fracture and compression-shear mixed-mode fracture on the propagation of rock crack is analyzed. Results show that ${\sigma}_3$ changes linearly with the change of ${\sigma}_1$. And the change rate is related to ${\beta}$, angle between the cracks and ${\sigma}_1$. The proposed simple analytical approach is economical and efficient, and suitable for the analysis of local nearly horizontal stratum in super-large section and deep buried tunnel.

콘크리트에서 국소화된 파괴해석을 위한 유한요소법 (A Finite Element Method for Localized Failure Analysis of Concrete)

  • 송하원;김형운;우승민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.233-238
    • /
    • 1999
  • Localized failure analysis of concrete structures can be carried out effectively by modeling fracture process zone of concrete during crack initiation and propagation. But, the analysis techniques are still insufficient for crack modeling because of difficulties in numerical analysis procedure which describe progressive crack. In this paper, a finite element with embedded displacement discontinuity is introduced to remove the difficulties of remeshing for crack propagation in discrete crack model during progressive failure analysis of concrete structures. The performance of this so-called embedded crack approach for concrete failure analysis is verified by several analysis examples. The analysis results show that the embedded crack approach retains mesh size objectivity and can simulate localized failure under mixed mode loading. It can be concluded that the embedded crack approach cab be an effective alternate to the smeared and discrete crack approaches.

  • PDF

현실적 공정 FMEA 평가기준 개발 (Practical Criteria for Process FMEA)

  • 김태혁;장중순;이은열
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제10권2호
    • /
    • pp.123-135
    • /
    • 2010
  • Failure mode and effects analysis (FMEA) is a widely used technique to assess or to improve reliability of products or processes at early stage of development. Traditionally, the prioritization of failures for corrective actions is performed by evaluating risk priority numbers (RPN). In practice, due to insufficient evaluation criteria specific to related products and processes, RPN is not always evaluated properly. This paper reestablishes an effective methodology for prioritization of failure modes in FMEA procedure. Revised evaluation criteria of RPN are devised and a refined FMEA sheet is introduced. To verify the proposed methodology, it is applied to inspection processes of PCB products.

역지밸브의 고장 원인 분석 (Analysis of Failure Causes for Check Valves)

  • 송석윤;유성연
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.607-612
    • /
    • 2005
  • Check valves playa vital role in the operation and protection of nuclear power plants. Check valves failure in nuclear power plants often lead to a plant transient or trip. An overview of the failure history of check valves needs to identify key area where resources can be best applied to further improve their reliability, and provide cost effective means for failure reduction. The analysis of historical failure data gives information on the populations of various types of check valves, the systems they are installed in, failure modes, effects, methods of detection, and the mechanisms of the failures. The results presented are based on information derived from operating records, nuclear industry reports, manufacturer supplied information. A majority of check valve failures are caused by improper application. Failure modes are identified for swing and lift check valves. Failures involving improper seating and valve disc stuck comprised the largest percentage of failures.

  • PDF

FMEA 기법을 활용한 공동주택 골조공사의 건설실패 핵심관리요인 분석 (An Analysis of Critical Management Factors for Construction Failure on the Apartment Structural Framework using FMEA)

  • 오치돈;박찬식
    • 한국건설관리학회논문집
    • /
    • 제13권3호
    • /
    • pp.78-88
    • /
    • 2012
  • 국내의 건설실패 관련 연구는 체계화된 실패정보 분류체계 및 실패정보의 활용을 위한 방안을 제시하는 것에 초점을 맞추고 있다. 그러나, 건설현장의 한정된 관리자가 건설실패를 유발하는 다양한 원인에 대한 예방대책을 수립하는 것은 한계가 있다. 따라서, 효율적인 건설실패 예방활동이 이루지기 위해서는 많은 실패원인에 대한 정량적 평가를 통해 우선순위를 정하여 효율적인 예방대책이 수립되어야 한다. 이에 본 연구는 정량적인 평가를 통해 실패를 유발하는 핵심관리요인을 도출 할 수 있도록 FMEA(Failure Mode and Effect Analysis) 기법을 활용한 건설실패 핵심관리요인 선정방법을 제시하고, 공동주택 골조공사를 대상으로 핵심관리요인을 분석하는 것을 목적으로 하였다. 이를 위해 FMEA 기법의 위험도를 실패 위험성과 예방성으로 구분하여 평가할 수 있도록 하였다. 본 연구에서 제시한 핵심관리요인 평가방법은 건설실패의 사전예방대책을 효율적으로 수립하는데 활용될 수 있으며, 향후 유사한 연구를 통해 프로젝트 수행 단계별 혹은 다양한 시설 및 공종에 대한 핵심관리요인을 도출하는데 활용될 수 있을 것으로 기대된다.

Development of a Failure Mode and Effects Analysis Based Risk Assessment Tool for Information Security

  • Lai, Lotto Kim Hung;Chin, Kwai Sang
    • Industrial Engineering and Management Systems
    • /
    • 제13권1호
    • /
    • pp.87-100
    • /
    • 2014
  • Risk management is recognized as a significant element in Information Security Management while the failure mode and effects analysis (FMEA) is widely used in risk analysis in manufacturing industry. This paper aims to present the development work of the Information Security FMEA Circle (InfoSec FMEA Circle) which is used to support the risk management framework by modifying traditional FMEA methodologies. In order to demonstrate the "appropriateness" of the InfoSec FMEA Circle for the purposes of assessing information security, a case study at Hong Kong Science and Technology Parks Corporation (HKSTP) is employed. The "InfoSec FMEA Circle" is found to be an effective risk assessment methodology that has a significant contribution to providing a stepwise risk management implementation model for information security management.

고장유형영향분석을 활용한 항암화학요법의 환자안전간호 효과분석 (Analysis of Effects of Chemotherapy using Failure Mode and Effect Analysis (FMEA) on Patient Safety and Safe Nursing)

  • 양남영;이미향
    • 간호행정학회지
    • /
    • 제21권3호
    • /
    • pp.254-262
    • /
    • 2015
  • Purpose: This study was done to apply failure mode & effect analysis (FMEA) to chemotherapy in order to reduce prescribing, dispensing and administering errors related to treatment and provide patients with a safe medical environment. Methods: A one group pre-post test design was used to verify the effects using the tool for FMEA in chemotherapy. Results: There was a statistically significant decrease in prescribing errors from 11.47% to 3.18%; administering errors decreased but they were not statistically significant. In a addition, there was no change in dispensing errors. Conclusion: The results show that FMEA removed risk factors that might occur during the process of chemotherapy and that it was an effective tool for prevention of negligent accident occurring in actual patients.