• 제목/요약/키워드: Failure Isolation

검색결과 135건 처리시간 0.026초

프랑스의 대형 주거단지 '그랑 앙상블'의 실패와 그 재생수법에 관한 연구 (A Study on the Failure of Grands Ensembles of France and on the Methods of Renovation)

  • 손세관
    • 한국주거학회논문집
    • /
    • 제25권5호
    • /
    • pp.113-124
    • /
    • 2014
  • The grands ensembles, or large-scale high-rise housing projects, are widely regarded as notorious products of postwar French government policy in the area of housing and urban planning. There was a general consensus that the grands ensembles had been a 'failure'. They were perceived as the source of all the ills of the contemporary city, as responsible for a social breakdown stemming from lack of infrastructure, geographical isolation, and monotonous environments. French government embarked on a broad renovation effort in light of the deteriorated condition of grands ensembles in the 1980s, which has been approved as generally 'successful'. This study focusing on French cases allowed me to demonstrate that following qualifications are critically important for successful housing projects: urban contextual continuity, socially mixed community, authentic planning for achieving sense of place, relationship between collective and individual expression, et cetera.

Detection and Diagnosis Solutions for Fault-Tolerant VSI

  • Cordeiro, Armando;Palma, Joao C.P.;Maia, Jose;Resende, Maia J.
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1272-1280
    • /
    • 2014
  • This paper presents solutions for fault detection and diagnosis of two-level, three phase voltage-source inverter (VSI) topologies with IGBT devices. The proposed solutions combine redundant standby VSI structures and contactors (or relays) to improve the fault-tolerant capabilities of power electronics in applications with safety requirements. The suitable combination of these elements gives the inverter the ability to maintain energy processing in the occurrence of several failure modes, including short-circuit in IGBT devices, thus extending its reliability and availability. A survey of previously developed fault-tolerant VSI structures and several aspects of failure modes, detection and isolation mechanisms within VSI is first discussed. Hardware solutions for the protection of power semiconductors with fault detection and diagnosis mechanisms are then proposed to provide conditions to isolate and replace damaged power devices (or branches) in real time. Experimental results from a prototype are included to validate the proposed solutions.

입출력 비연성을 이용한 액추에이터 모니터링 기술 개발 (Development of Actuator Monitoring Technique through Decoupled Input-Output)

  • 고봉환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.301-305
    • /
    • 2005
  • This paper introduces a novel technique to detect and isolate the failures of multiple actuators connected to a system. Failure of actuator considered in this study could be any type of erroneous input that is different from commanded one. The interaction matrix technique allows the development of input-output equations that are only influenced by one target input. These input-output equations serve as an effective toot to monitor the integrity of each actuator regardless of the status of the other actuators. The method is capable of real-time actuator failure detection and isolation under any type of input excitation. The laboratory experiment using 8-bay NASA truss structure verifies the feasibility of the proposed method.

  • PDF

A Failure Estimation Method of Steel Pipe Elbows under In-plane Cyclic Loading

  • Jeon, Bub-Gyu;Kim, Sung-Wan;Choi, Hyoung-Suk;Park, Dong-Uk;Kim, Nam-Sik
    • Nuclear Engineering and Technology
    • /
    • 제49권1호
    • /
    • pp.245-253
    • /
    • 2017
  • The relative displacement of a piping system installed between isolated and nonisolated structures in a severe earthquake might be larger when without a seismic isolation system. As a result of the relative displacement, the seismic risks of some components in the building could increase. The possibility of an increase in seismic risks is especially high in the crossover piping system in the buildings. Previous studies found that an elbow which could be ruptured by low-cycle ratcheting fatigue is one of the weakest elements. Fatigue curves for elbows were suggested based on component tests. However, it is hard to find a quantitative evaluation of the ultimate state of piping elbows. Generally, the energy dissipation of a solid structure can be calculated from the relation between displacement and force. Therefore, in this study, the ultimate state of the pipe elbow, normally considered as failure of the pipe elbow, is defined as leakage under in-plane cyclic loading tests, and a failure estimation method is proposed using a damage index based on energy dissipation.

PROBABILISTIC SEISMIC ASSESSMENT OF BASE-ISOLATED NPPS SUBJECTED TO STRONG GROUND MOTIONS OF TOHOKU EARTHQUAKE

  • Ali, Ahmer;Hayah, Nadin Abu;Kim, Dookie;Cho, Ung Gook
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.699-706
    • /
    • 2014
  • The probabilistic seismic performance of a standard Korean nuclear power plant (NPP) with an idealized isolation is investigated in the present work. A probabilistic seismic hazard analysis (PSHA) of the Wolsong site on the Korean peninsula is performed by considering peak ground acceleration (PGA) as an earthquake intensity measure. A procedure is reported on the categorization and selection of two sets of ground motions of the Tohoku earthquake, i.e. long-period and common as Set A and Set B respectively, for the nonlinear time history response analysis of the base-isolated NPP. Limit state values as multiples of the displacement responses of the NPP base isolation are considered for the fragility estimation. The seismic risk of the NPP is further assessed by incorporation of the rate of frequency exceedance and conditional failure probability curves. Furthermore, this framework attempts to show the unacceptable performance of the isolated NPP in terms of the probabilistic distribution and annual probability of limit states. The comparative results for long and common ground motions are discussed to contribute to the future safety of nuclear facilities against drastic events like Tohoku.

Probabilistic behavior of semi-active isolated buildings under pulse-like earthquakes

  • Oncu-Davas, Seda;Alhan, Cenk
    • Smart Structures and Systems
    • /
    • 제23권3호
    • /
    • pp.227-242
    • /
    • 2019
  • Seismic isolation systems employ structural control that protect both buildings and vibration-sensitive contents from destructive effects of earthquakes. Structural control is divided into three main groups: passive, active, and semi-active. Among them, semi-active isolation systems, which can reduce floor displacements and accelerations concurrently, has gained importance in recent years since they don't require large power or pose stability problems like active ones. However, their seismic performance may vary depending on the variations that may be observed in the mechanical properties of semi-active devices and/or seismic isolators. Uncertainties relating to isolators can arise from variations in geometry, boundary conditions, material behavior, or temperature, or aging whereas those relating to semi-active control devices can be due to thermal changes, inefficiencies in calibrations, manufacturing errors, etc. For a more realistic evaluation of the seismic behavior of semi-active isolated buildings, such uncertainties must be taken into account. Here, the probabilistic behavior of semi-active isolated buildings under historical pulse-like near-fault earthquakes is evaluated in terms of their performance in preserving structural integrity and protecting vibration-sensitive contents considering aforementioned uncertainties via Monte-Carlo simulations of 3-story and 9-story semi-active isolated benchmark buildings. The results are presented in the form of fragility curves and probability of failure profiles.

헥사콥터의 구동기 고장 검출 및 분리 방법 (Actuator Fault Detection and Isolation Method for a Hexacopter)

  • 박민기
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.266-272
    • /
    • 2019
  • 멀티콥터는 수직 이착륙 할 수 있다는 장점 때문에 활용이 증가하고 있으며 이러한 멀티콥터의 정상적인 동작을 위해서는 고장 검출과 분리 문제가 매우 중요하다. 본 논문에서는 해석적 방법에 기반하여 헥사콥터 구동기의 고장을 검출하고 분리하는 새로운 방법을 제안한다. 제안한 방법에서는 헥사콥터의 수학적 모델로부터 추정한 구동기의 각속도를 이용하여 잔차를 새롭게 정의하고 생성된 잔차와 문턱값을 비교하여 구동기의 고장을 검출한다. 고장이 검출되면 헥사콥터의 동역학 모델과 생성된 잔차를 결합하여 고장을 분리한다. 제안한 방법은 수학적 모델을 기반으로 하여 간단하면서도 효과적이다. 헥사콥터 구동기의 단일 고장 상황을 가정한 시뮬레이션을 통해 제안한 방법의 유효성을 검증하였다.

Vision-based support in the characterization of superelastic U-shaped SMA elements

  • Casciati, F.;Casciati, S.;Colnaghi, A.;Faravelli, L.;Rosadini, L.;Zhu, S.
    • Smart Structures and Systems
    • /
    • 제24권5호
    • /
    • pp.641-648
    • /
    • 2019
  • The authors investigate the feasibility of applying a vision-based displacement-measurement technique in the characterization of a SMA damper recently introduced in the literature. The experimental campaign tests a steel frame on a uni-axial shaking table driven by sinusoidal signals in the frequency range from 1Hz to 5Hz. Three different cameras are used to collect the images, namely an industrial camera and two commercial smartphones. The achieved results are compared. The camera showing the better performance is then used to test the same frame after its base isolation. U-shaped, shape-memory-alloy (SMA) elements are installed as dampers at the isolation level. The accelerations of the shaking table and those of the frame basement are measured by accelerometers. A system of markers is glued on these system components, as well as along the U-shaped elements serving as dampers. The different phases of the test are discussed, in the attempt to obtain as much possible information on the behavior of the SMA elements. Several tests were carried out until the thinner U-shaped element went to failure.

쌍일차계에 대한 FDI(고장검출 및 분리)의 대수적인 해석에 관한 연구 (A Study on the Algebraic Analysis of FDI(failure detection and isolation) in Bilinear System)

  • 인돈기;조영호;오민환;김재일;채영무;안두수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2627-2629
    • /
    • 2000
  • This paper introduces the design of a reduced order observer with unknown inputs for the purpose of fault detection and isolation(FDI) in a class of bilinear systems. To Analyze the observer and FDI, this paper uses BPF(block-pulse functions). The operational properties of BPF are much applied to the analysis of bilinear systems. The integral operational matrix BPF converts the form of the differential equation into the algebraic problems.

  • PDF

전자부품 고장모드를 고려한 Built-In-Test 성능분석 (Built-In-Test Coverage Analysis Considering Failure Mode of Electronics Components)

  • 서준호;고진영;박한준
    • 한국항공우주학회지
    • /
    • 제43권5호
    • /
    • pp.449-455
    • /
    • 2015
  • Built-In-Test(이하: BIT)는 항공기 비행안전을 위해 반드시 필요한 기능으로 항공전자 장비의 경우 95% 이상의 높은 고장 진단능력을 요구하고 있다. BIT가 요구도에 명시된 고장 진단능력을 만족시키는지 확인하기 위해 BIT 성능분석이 필요하다. BIT 성능분석을 위해 FMECA (Failure Mode Effect Critical Analysis)에 기술된 고장모드를 활용하는 방법이 많이 사용되고 있으나, 본 논문에서는 분석 오류를 최소화할 수 있는 전자부품 기반의 BIT 성능분석 방법론을 소개한다. 또한, BIT 성능분석에서 제외될 수 있는 비행안전에 영향을 미치지 않는 전자부품 및 전자부품의 고장모드를 실제 개발사례에 적용하여 불필요한 BIT 기능 구현을 방지하고 정확한 BIT 성능분석을 수행할 수 있도록 하였다. BIT Demo를 수행하여 BIT 성능분석 결과와 실제 BIT 성능이 일치함을 확인하였다.