• Title/Summary/Keyword: Factor of energy consumption

Search Result 378, Processing Time 0.038 seconds

Analysis on Electricity Consumption Characteristics of Apartments based on Architectural Planning Factors - foused on Households with a total area of 132~165㎡ in Seoul- (공동주택 건축계획요소에 따른 전기 에너지 소비특성 분석 - 서울지역의 40평형(132~165㎡)의 단위세대 전기에너지 사용량을 중심으로 -)

  • Park, So-Yun;Lee, Yun-Jae;Lee, Hyun-Soo
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.107-117
    • /
    • 2011
  • This paper aims to analyze architectural planning factors that could contribute to reductions in electricity consumption in the household of apartments, to apply energy saving methods at the design phase. These six architectural planning factors were orientation, building type (flat, tower block), standard floor access type (corridor access type, stair case type, EV hall access type), household location (floor), household opening type (one side opening, right angle opening, two sides opening or three sides opening), and bay on the facade (one bay, two bays, three bays, four bays), and these were derived from literature review. Household electricity consumption data were gathered from 2168 households with a total area of 135~150$m^2$ of 6 apartment complexes over 1000 households in Seoul. The annual characteristics of electricity consumption according to architectural planning factors were analyzed. And, variances between groups with respect to the mean of summer, winter, and annual electricity consumption according to each architectural planning factors were analyzed using ANOVA and t-test. The results showed that an annual electric energy saving of over 1000kWh was facilitated by these planning factors. In addition, high energy efficiency architectural planning factors based on the analysis were as follows: southwest orientation, flat type, corridor access type and staircase type, household loation below the 20th floor, two sides opening and three sides opening, and 2 bays and 3 bays.

A Comparative Analysis on Performance of Wireless Sensor Networks Routing Protocols

  • KRISHNA, KONDA. HARI;NAGPAL, TAPSI;BABU, Y. SURESH
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.7
    • /
    • pp.240-244
    • /
    • 2022
  • The common goals of designing a routing algorithm are not only to reduce control packet overhead, maximize throughput and minimize the end-to-end delay, but also take into consideration the energy consumption. Scalability is an important factor in designing an efficient routing protocol for wireless sensor networks (WSN's). Three metrics (power consumption, time of transmission and packet loss rate) are used in order to compare three routing protocols which are AODV, DSDV and LEACH.

Recommended Practice for Lighting Load Density by Feature Parameters and Regression Analysis depending on Power Consumption Characteristics in Subway Stations (회귀분석이론을 이용한 지하철 역사의 조명부하밀도 분석)

  • Jung, Hyeon-Ki;Kim, Se-Dong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.254-259
    • /
    • 2006
  • It is increased electrical energy consumption with the development of intelligence society in the subway station and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design load density in subway stations, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 34 subway stations and 10 electrical design offices. In this dissertation, it is necessary to analyse the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, maximum and thus it was carried linear and nonlinear regression analysis.

  • PDF

Consumer Perceptions on the Effects of Electricity Saving Methods and Electricity Saving Behavior (전기절약방법의 효과에 대한 소비자인식과 실천행동에 관한 연구)

  • Lee, Seong-Lim;Park, Myung-Hee;Lee, Eun-Young
    • Journal of Families and Better Life
    • /
    • v.26 no.4
    • /
    • pp.1-11
    • /
    • 2008
  • This study investigated consumers' energy saving behavior and perceptions concerning the effectiveness of their energy saving behavior. A nation wide survey was conducted involving 2000 households in urban areas and the data from 1767 households were used for the analysis. excluding cases with incomplete responses. Descriptive analysis, factor analysis, and regression analysis were applied. The results were as follows. First, electricity saving behavior was classified into three categories: Thrift (reducing energy consumption), Purchase (buying energy saving appliances), and Control (checking the energy consumption). Second, consumers rated Thrift as the best way to save energy. Third, education, age, and household income were significantly related to energy saving behavior and perceptions on the effectiveness of energy saving behavior. Consumers using above average levels of electricity tended not to practice energy saving behavior and not to positively evaluate effectiveness of the energy saving behavior. Lastly, the implications for public policies to promote energy saving behavior are suggested.

A Study on the Characteristic of Emission for Air Pollutant by Small Two-stroke Engines (2행정 소형엔진의 대기오염물질 배출특성에 관한 연구)

  • Kim, Pil-Su;Choi, Sang-Jin;Park, Geon-Jin;Han, Yong-Hee;Kim, Dai-Gon;Yeo, So-Young;Kim, Jeong;Goh, Ji-Won;Jang, Young-Kee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.6
    • /
    • pp.613-623
    • /
    • 2016
  • In this study, pilot experiments were conducted by setting operation conditions to analyze characteristics of emission for air pollutant from small two-stroke engines. Emission factors of the measured concentration of pollutant were compared with EEA. Emission factor of CO analyzed by experiments - concentration, flow rate, fuel consumption, etc.- was estimated at 816,011 g-CO/ton-fuel in average. It was confirmed that more than 80% of the fuel consumption is discharged to the Carbon Monoxide, and that as the engine load becomes higher, emission factor of CO increases in the form of log function. The average emission factor of $NO_x$ and $PM_{10}$ was $3,801g-NO_x/ton-fuel$ and $3,730g-PM_{10}/ton-fue$l each. The deviation was not large by comparing the fuel-based emission factor of EEA and the result of this study. Since considerable pollutants are expected to be discharged from the small two-stroke engines, continuous research and support of the policy is required.

Analysis of hydraulic system for seawater desalination plant through piping analysis program (배관 해석 프로그램을 통한 해수담수화 플랜트 수압 시스템 분석)

  • Choi, Jihyeok;Choi, Yongjun;Yang, Heungsik;Lee, Sangho;Choi, June-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.221-230
    • /
    • 2020
  • In actual seawater desalination plant, the pressure loss due to frictional force of pipe is about 3~5 bar. Also, the pressure loss at pipe connection about 1~3 bar. Therefore, the total pressure loss in the pipe is expected to be about 4~8 bar, which translates into 0.111 to 0.222 kWh/㎥ of energy when converted into the Specific Energy Consumption(SEC). Reducing energy consumption is the most important factor in ensuring the economics of seawater desalination processes, but pressure loss in piping is often not considered in plant design. It is difficult to prevent pressure loss due to friction inside the pipe, but pressure loss at the pipe connection can be reduced by proper pipe design. In this study, seawater desalination plant piping analysis was performed using a commercial network program. The pressure loss and SEC for each case were calculated and compared by seawater desalination plant size.

A Study of Load Matching on the Net-Zero Energy House (넷 제로에너지주택의 부하매칭에 관한 연구)

  • Kim, Beob-Jeon;Lim, Hee-Won;Kim, Deok-Sung;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.4
    • /
    • pp.55-66
    • /
    • 2018
  • nZEH (net-Zero Energy House) is defined as a self-sufficient energy building where the sum of energy output generated from new & renewable energy system and annual energy consumption is zero. The electricity generated by new & renewable energy system with the form of distributed generation is preferentially supplied to electrical demand, and surplus electricity is transmitted back to grid. Due to the recent expansion of houses with photovoltaic system and the nZEH mandatory by 2025, the rapid increase of distributed generation is expected. Which means, we must prepare for an electricity-power accident and stable electricity supply. Also electricity charges have to be reduce and the grid-connected should be operated efficiently. The introduction of ESS is suggested as a solution, so the analysis of the load matching and grid interaction is required to optimize ESS design. This study analyzed the load matching and grid interaction by expected consumption behavior using actual data measured in one-minute intervals. The experiment was conducted in three nZEH with photovoltaic system, called all-electric houses. LCF (Load Cover Factor), SCF (Supply Cover Factor) and $f_{grid}$ (Grid Interaction Index) were evaluated as an analysis indicator. As a result, LCF, SCF and $f_{grid}$ of A house were 0.25, 0.23 and 0.27 respectively; That of B house were 0.23, 0.23, 0.19, and that of C were 0.20, 0.19, 0.27 respectively.

Novel Packet Switching for Green IP Networks

  • Jo, Seng-Kyoun;Kim, Young-Min;Lee, Hyun-Woo;Kangasharju, Jussi;Mulhauser, Max
    • ETRI Journal
    • /
    • v.39 no.2
    • /
    • pp.275-283
    • /
    • 2017
  • A green technology for reducing energy consumption has become a critical factor in ICT industries. However, for the telecommunications sector in particular, most network elements are not usually optimized for power efficiency. Here, we propose a novel energy-efficient packet switching method for use in an IP network for reducing unnecessary energy consumption. As a green networking approach, we first classify the network nodes into either header or member nodes. The member nodes then put the routing-related module at layer 3 to sleep under the assumption that the layer in the OSI model can operate independently. The entire set of network nodes is then partitioned into clusters consisting of one header node and multiple member nodes. Then, only the header node in a cluster conducts IP routing and its member nodes conduct packet switching using a specially designed identifier, a tag. To investigate the impact of the proposed scheme, we conducted a number of simulations using well-known real network topologies and achieved a more energy- efficient performance than that achieved in previous studies.

Recommended Practice for a Reasonable Design Demand Factor and Analysis of Power Consumption Characteristics by loads in Hospitals (병원용 건물의 부하종별 전력소비특성 분석 및 수용률 기준 정립에 관한 연구)

  • Yoo, Sang-Bong;Kim, Se-Dong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.77-84
    • /
    • 2007
  • It is increased electrical energy consumption with the development of intelligence society in hospitals and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design demand factor in hospitals, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 32 hospitals and 9 electrical design offices. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried the linear and nonlinear regression analysis.

Recommended Practice for o Reasonable Design Demand Factor and Analysis of Power Consumption Characteristics by Loads in Office Buildings (사무소용 빌딩의 부하종별 전력소비특성 분석 및 수용률 기준 정립에 관한 연구)

  • Kim, Se-Dong;Lee, Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.111-118
    • /
    • 2005
  • It is increased electrical energy consumption with the development of intelligence society in the once buildings and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 54 office buildings and 34 electrical design offices. In this dissertation it is necessary to analyse the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimum and thus it was carried the linear and nonlinear regression analysis.