• Title/Summary/Keyword: Facility surfaces

Search Result 51, Processing Time 0.021 seconds

Study on the Application of Dry-Ice Blaster for Development of Automatic Stripe-Line Removal (노면표시 제거 장비 개발을 위한 드라이아이스 블래스터 적용에 관한 연구)

  • Koo, Ja Kyung;Moon, Deuk Soo;Bernold, Leonhard E.;Lee, Tai Si
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.2D
    • /
    • pp.245-253
    • /
    • 2009
  • Road facility is the most fundamental infrastructure for traffic and various information for smooth traffic is included in road surfaces. Various information included in road surfaces should be often removed and reinstalled by partial damage and aging. In addition, the existing road surface information should be removed in order to mark new information as traffic information changes. The existing road surface removal method suing grinders and torches had problems such as dangerous working equipment and workers' direct exposure to cars. In addition, although water-jet system using super high-pressure water was used to remove road surface in order of improvement of traditional method, there are another problems such as limitations according to water-tanks and water frost on the road surfaces after work. Therefore, this study analyzes and suggests systems to develop prototype after analyzing dry ice blaster in order to improve the current road surface removal methods. In addition, the study analyzes the possibility of introduction of dry ice blaster through a test for proposing an automatized equipment for new road surface mark removal considering environment and work efficiency, and compare traditional method with introduced dry ice blaster for operating cost.

Assessment of Water Circulation and Hydro-characteristics with LID techniques in urbanized areas (도시지역에 적용된 LID 기법의 강우시 수문특성 및 물순환 평가)

  • Choi, Hyeseon;Hong, Jungsun;Jeon, Minsu;Geronimo, Franz Kevin;Kim, Leehyung
    • Journal of Wetlands Research
    • /
    • v.21 no.3
    • /
    • pp.191-198
    • /
    • 2019
  • High impervious surfaces increase the surface runoff during rainfall and reduces the underground infiltration thereby leading to water cycle distortion. The distortion of water cycle causes various urban environmental problems such as urban flooding, drought, water pollutant due to non-point pollution runoff, and water ecosystem damage. Climate change intensified seasonal biases in urban rainfall and affected urban microclimate, thereby increasing the intensity and frequency of urban floods and droughts. Low impact development(LID) technology has been applied to various purposes as a technique to reduce urban environmental problems caused by water by restoring the natural water cycle in the city. This study evaluated the contribution of hydrologic characteristics and water cycle recovery after LID application using long-term monitoring results of various LID technology applied in urban areas. Based on the results, the high retention and infiltration rate of the LID facility was found to contribute significantly to peak flow reduction and runoff delay during rainfall. The average runoff reduction effect was more than 60% at the LID facility. The surface area of the LID facility area ratio(SA/CA) was evaluated as an important factor affecting peak flow reduction and runoff delay effect.

Development of an advanced atmospheric pressure plasma source with high spatial uniformity and selectiveness for surface treatment

  • Im, Yu-Bong;Choe, Won-Ho;Lee, Seung-Hun;Han, U-Yong;Lee, Jong-Hyeon;Lee, Sang-Gyun;Ha, Jeong-Min;Kim, Jong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.176-177
    • /
    • 2016
  • In the last few decades, attention toward atmospheric pressure plasma (APP) has been greatly increased due to the numerous advantages of those applications, such as non-necessity of high vacuum facility, easy setup and operation, and low temperature operation. The practical applications of APP can be found in a wide spectrum of fields from the functionalization of material surfaces to sterilization of medical devices. In the secondary battery industry, separator film has been typically treated by APP to enhance adhesion strength between adjacent films. In this process, the plasma is required to have high stability and uniformity for better performance of the battery. Dielectric barrier discharge (DBD) was usually adopted to limit overcurrent in the plasma, and we developed the pre-discharge technology to overcome the drawbacks of streamer discharge in the conventional DBD source which makes it possible to produce a super-stable plasma at atmospheric pressure. Simulations for the fluid flow and electric field were parametrically performed to find the optimized design for the linear jet plasma source. The developed plasma source (Plasmapp LJPS-200) exhibits spatial non-uniformity of less than 3%, and the adhesion strength between the separator and electrode films was observed to increase 17% by the plasma treatment.

  • PDF

강제진동 풍동시험을 통한 비행선의 동안정성 분석

  • Chang, Byeong-Hee;Ok, Ho-Nam;Lee, Yung-Gyo
    • Aerospace Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.1-10
    • /
    • 2003
  • An airship is statically unstable, because it has no wing, comparatively small tail and large hull. Hence, an accurate prediction of dynamic stability is critical. In this study, dynamic stability data of the Mid-Size Airship is acquired through forced oscillation wind tests. The test was done in BAR LAMP which is Birhle Applied Research Inc's facility located in Germany. The test was composed with 16 static runs and 26 dynamic runs. As a result, dynamic characteristics of the airship depends on sideslip angle, angular rate and its direction as well as angle of attack. Generally, it is obtained that 3 directional moments have damping, but normal force, side force, and cross-derivatives are unstable. The dynamic derivatives are not sensitive to control surfaces, but have nonlinear dependency on sideslip angle.

  • PDF

Factors affecting Healing of Stage 2 Pressure Ulcer (2단계 욕창 치유에 영향을 주는 요인 분석)

  • Park, Kyung-Hee;Kim, Keum-Soon
    • Journal of Korean Critical Care Nursing
    • /
    • v.3 no.2
    • /
    • pp.1-11
    • /
    • 2010
  • Purpose: This study was designed to identify the factors affecting healing of Stage 2 pressure ulcer in an acute care facility in Korea. Methods: 286 Stage 2 pressure ulcers of 145 patients were examined. Data were collected in the period between October $1^{st}$, 2006 and September $30^{th}$, 2007. Data were analyzed with Kaplan-Meier survival analysis for cumulative recovery rate of Stage 2 pressure ulcers. Cox proportional hazard model was used to examine effects of multiple variables simultaneously. Results: Out of 286 initial Stage 2 pressure ulcers, 204 (71.3%) pressure ulcers healed completely. The median time to heal was 15 days according to Kaplan-Meier survival analysis. Cox proportional hazard model showed that the Stage 2 pressure ulcers healed more quickly when pressure redistribution surfaces were used (p<.001, HR=2.184), patients were administered with vitamins (p= .038, HR=1.451), and the size of the pressure ulcers were small (${\leq}3.0cm^2$, p= .006, HR=1.765). Conclusion: The factors contributing to the healing of Stage 2 pressure ulcer in an acute care setting were the application of pressure redistribution surface, small ulcer size (${\leq}3.0cm^2$), and the administration of vitamins.

  • PDF

A STUDY OF THE PRESSURE SOLUTION AND DEFORMATION OF QUARTZ CRYSTALS AT HIGH pH AND UNDER HIGH STRESS

  • Choi, Jung-Hae;Seo, Yong-Seok;Chae, Byung-Gon
    • Nuclear Engineering and Technology
    • /
    • v.45 no.1
    • /
    • pp.53-60
    • /
    • 2013
  • Bentonite is generally used as a buffer material in high-level radioactive waste disposal facilities and consists of 50% quartz by weight. Quartz strongly affects the behavior of bentonite over very long periods. For this reason, quartz dissolution experiment was performed under high-pressure and high-alkalinity conditions based on the conditions found in a high-level radioactive waste disposal facility located deep underground. In this study, two quartz dissolution experiments were conducted on 1) quartz beads under low-pressure and high-alkalinity conditions and 2) a single quartz crystal under high-pressure and high-alkalinity conditions. Following the experiments, a confocal laser scanning microscope (CLSM) was used to observe the surfaces of experimental samples. Numerical analyses using the finite element method (FEM) were also performed to quantify the deformation of contact area. Quartz dissolution was observed in both experiments. This deformation was due to a concentrated compressive stress field, as indicated by the quartz deformation of the contact area through the FEM analysis. According to the numerical results, a high compressive stress field acted upon the neighboring contact area, which showed a rapid dissolution rate compared to other areas of the sample.

A Study on the Characteristics of the Earth Heat Extraction Using Termosyphon (Termosyphon의 지열채열 성능에 관한 고찰)

  • Shin, H.J.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.226-233
    • /
    • 1993
  • Thermosyphons are simple devices that can passively transport thermal energy over relatively large distance with little temperature degradation. Especially, the thermosyphon system requires no costly energy input and is completely maintenance free. These attributes permit the use of low grade thermal energy for thermal control of structures including the stabilization of highway foundations. This paper presents the experimental results of the snow melting system in which thermosyphon was utilized to ransfer the earth energy to the pavement to remove snow and ice. The test facility, three earth heated and one unheated test panels, is designed to investigate the variables associated with removing snow and ice from pavement surfaces. The results of these test show that the earth heated panel surface temperature is higher $2{\sim}6^{\circ}C$ than unheated panel when the ambient air temperature is $-7^{\circ}C$. The thermal performance of this earth source thermosyphon system for road heating showed that there was no snow on the heated test panels when the snowfall was 5cm average for the region.

  • PDF

Towards guidelines for design of loose-laid roof pavers for wind uplift

  • Mooneghi, Maryam Asghari;Irwin, Peter;Chowdhury, Arindam Gan
    • Wind and Structures
    • /
    • v.22 no.2
    • /
    • pp.133-160
    • /
    • 2016
  • Hurricanes are among the most costly natural hazards to impact buildings in coastal regions. Building roofs are designed using the wind load provisions of building codes and standards and, in the case of large buildings, wind tunnel tests. Wind permeable roof claddings like roof pavers are not well dealt with in many existing building codes and standards. The objective of this paper is to develop simple guidance in code format for design of loose-laid roof pavers. Large-scale experiments were performed to investigate the wind loading on concrete roof pavers on the flat roof of a low-rise building in Wall of Wind, a large-scale hurricane testing facility at Florida International University. They included wind blow-off tests and pressure measurements on the top and bottom surfaces of pavers. Based on the experimental results simplified guidelines are developed for design of loose-laid roof pavers against wind uplift. The guidelines are formatted so that use can be made of the existing information in codes and standards such as American Society of Civil Engineering (ASCE) 7-10 standard's pressure coefficients for components and cladding. The effects of the pavers' edge-gap to spacer height ratio and parapet height to building height ratio are included in the guidelines as adjustment factors.

Turbine Performance Degradation Due to Blade Surface Roughness (블레이드 표면거칠기에 따른 터빈 성능저하)

  • Park, Il-Young;Yun, Yong-Il;Song, Seung-Jin
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.92-98
    • /
    • 2003
  • Turbine blades experience significant surface degradation with service. This paper presents experimental evidence of blade surface roughness reducing turbine efficiency. Performance tests were conducted in a low speed, single-stage axial flow turbine rig with roughened blade surfaces. Sheets of sandpaper with equivalent sandgrain roughnesses of 106 and $400{\mu}m$ were used to roughen the blades. In these tests, effects of roughened stator vanes and rotor blades were separately evaluated. In the fully rough regime ($k_{s}=400{\mu}m$), the experimental results show an 11 percent decrease in normalized efficiency with roughness only on stator vanes ; an 8 percent decrease with roughness only on rotor blades ; and a 19 percent decrease with roughness on both the stator and rotor blades. In the transitionally rough regime ($k_{s}=106{\mu}m$), the trends are similar approximately 4 percent decrease with either roughened stator or roughened rotor and an 8 percent decrease with roughness on both stator and rotor blades. Thus, roughened stator vanes incur more performance penalty than roughened rotor blades.

  • PDF

Emulsification Characters of COY (Cooking Oil and Egg Yolk Mixture) and Mixing Application with Sulfur Wettable Powder for Enhancing the Control Efficacies against Paprika Powdery Mildew (파프리카 흰가루병 방제용 난황유의 유화특성과 유황수화제와의 혼용 시 방제효과)

  • Lee, Jung-Han;Han, Ki-Soo;Bae, Dong-Won;Kwon, Young-Sang;Kim, Dong-Kil;Kang, Kyu-Young;Kim, Hee-Kyu
    • Research in Plant Disease
    • /
    • v.16 no.1
    • /
    • pp.74-80
    • /
    • 2010
  • Emulsification characters were investigated for COY (Cooking oil and Egg Yolk Mixture) and control efficacies of COY was enhanced by supplemented Sulfur wp. against paprika powdery mildews. Amount of water added to one egg yolk and 100 ml olive oil affected tbe homogenization of mixtures to emulsion profoundly; those premixes with 5~10 ml water were too concentrated to be homogenized, hence not dispersible in water; those with 15~20 ml water were homogenized, but tended to flocculation and not readily dispersible in water, suggesting the instability of emulsion; and those with 50 or 100 ml water were homogenized well and was readily dispersible in water to stable emulsion over long period of time. It was further confirmed that those fruits sprayed with not-fully emulsified COY revealed the oily membranes or blotches on their surfaces, whereas the ones with fully emulsified COY revealed normal clean surfaces. Treatment of COY either alone or in supplementation with Sulfur wettable powder (sulfur wp) were also effective in suppressing the recurrence of powdery mildew signs, wbich had disappeared in three days of foliar application. Still, the COYs supplemented with sulfur wp (COY+sulfur wp) at 1,000x or 5,000x were significantly effective in suppression against the symptomlsign recurrence over COY or sulfur wp alone.