• Title/Summary/Keyword: Facility safety design

Search Result 508, Processing Time 0.029 seconds

Developement of a Design Manual for Kitchen Facility in Foodservice Outlets: A Case Study on a Seolleongtang Specialized Restaurant (푸드서비스시설의 주방 설비 산정 매뉴얼 개발: 설렁탕 전문 식당 사례 적용)

  • Choi, Gyeong-Gy;Chang, Hye-Ja
    • Journal of the FoodService Safety
    • /
    • v.2 no.2
    • /
    • pp.67-77
    • /
    • 2021
  • Concerns regarding work and food safety in foodservice operations are growing. The purpose of the study is to suggest guidelines for designing foodservice facilities, including school foodservices and Korean restaurants. A case of a franchise restaurant specializing in a Korean food item, Seolleongtang, was used to explain the facility design. The contents of the manual included ways to determine space allocation, calculate the application of utilities and the diameters of supply utility pipelines, and suggestions on how to decide on air conditioning equipment. The standards of the American Gas Association and the Japan Foodservice Equipment Association (JFEA) were applied to design the restaurant space. The JFEA standards and knowledge based on experience and statistics were applied to calculate the usage of utilities like fuel and water. The standards of JFEA and the Society of Heating, Air-Conditioning, and Sanitary Engineers of Japan were applied to calculate the diameters of the water supply and drainage pipelines. For the setting of the heating, ventilation, and air conditioning systems, three ways to carry out the calculation of effective ventilation were explained, as well as options to dicide the standard parameters of the duct and ventilation fans. This manual can contribute to the design of effective and efficient foodservice facilities and help secure the work safety of foodservice employees thereby ensuring food safety.

A Study on the Facility Accessibility of the Wheelchaired Persons for the Concept of Universal Design (휠체어 사용자의 Universal Access를 위한 시설 접근성 연구)

  • Jin, Sangeun;Yoo, Youngmi;Lee, Junhee;Park, Wongu
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.54-61
    • /
    • 2018
  • Objective: The current study aimed to investigate the accessibility and usability of the disabled person while using the everyday facility. Background: The national laws regulated accommodation of persons with disabilities, but our knowledge on the practical usefulness of the laws and acceptance by the users is still far from complete. Method: Compliance with laws was checked throughout the actual measurement of 87 engineering designs in the facilities of a national university, and the practical usability of the facilities was investigated by in-depth interviews with eight disabled persons. New design solutions were developed by the anthropometric methodology for better accommodation. The target-specific anthropometry database such as sitting knee height with wheelchair was employed. Results: First, the statistic showed that 28.7% of facility designs comply with the law, 29.9% of facility designs doesn't comply with the law, and 41.4% of facility designs doesn't have related law or regulation. Second, the law of table height(71cm in current) can accommodate only 49.3% of wheelchaired population. The following test for 95% accommodation revealed that the table with 80cm high is required. Third, the current law in the door width(90cm) can only accommodate 82.6% of disabled persons, so the new design solution was calculated and suggested that 100cm in the door width is necessary for 99% accommodation of disabled persons. Conclusion: Even with the laws and regulations for the disabilities it was clear that the accessibility and usability of the disabled persons in everyday facilities was still limited. An investigation for the new solutions about a wide range of facilities is necessary for better practical accessibility and usability of the handicapped persons. Application: The results of current study can be a basement of developing a new guideline or regulation of the facility design for the disabled persons.

Preparation and Management of the Input Data for the Safety Assessment of Low- and Intermediate-level Radioactive Waste Disposal Facility in Korea (중·저준위 방사성폐기물 처분시설 안전성평가를 위한 입력데이터 설정 및 관리에 대한 고찰)

  • Park, Jin Beak;Kim, Hyun-Joo;Lee, Dong-Hee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.4
    • /
    • pp.345-361
    • /
    • 2014
  • The systematic quality assurance activities on documents of the safety assessment are required for the safety case of the low- and intermediate-level radioactive waste disposal facility. In this paper, quality assurance system focused on the input data including the site characterization, groundwater flow, system design and monitoring are prepared and discussed. Rule for the input data selection is suggested and applied for the safety assessment which is based on the in-situ/experiment observations, final facility design and waste pileup plan, engineered barrier, field monitoring, recent biosphere, and radionuclide inventory. The reduction of data uncertainty will be expected to contribute to the safety of disposal facility further.

Contemporary Safety Management of Virtual Golf in South Korea

  • MOON, Bo Ra;LEE, Seung Min;SEO, Won Jae
    • Journal of Sport and Applied Science
    • /
    • v.6 no.1
    • /
    • pp.1-4
    • /
    • 2022
  • Purpose: The purpose of this study is to provide implications for virtual golf safety management in Korea through the literature review of current safety issues of virtual golf industry. Research design, data, and methodology: This study employed a qualitative approach to review prior studies and related documents presenting current safety perspectives of virtual sports facility management. First, the study reviewed the experiences of virtual golf players and safety criteria suggested from previous literatures. Second, two experts in sport facility management reviewed the manuscript including implications and provided their opinions including major implications and insights for virtual sport industry. Views of experts were added to the final manuscript. Results: This study found that installation standards and safety and hygiene standards by industry are enacted for the safety management of sports facilities, however, there is a need for standards to be adjusted because the contents are general, abstract, and lack detail, thus causing difficultly to secure effectiveness. Conclusions: For virtual golf courses, it is necessary to develop a safety inspection checklist that suits the characteristics of indoor virtual golf. In this line, safety criteria need to be developed with the consideration of characteristics of screen golf to establish an efficient safety management system and create a safe use environment.

A Study on the Earthquake Safety Assessment of Energy Storage Facilities According to Climate Change (기후변화에 따른 에너지 저장시설 지진 안전성평가에 관한 연구)

  • Ham, Eun-Gu;Lee, Sung-Il
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.226-235
    • /
    • 2021
  • Purpose: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Method: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Result: In this study, by statically loading earthquake loads and evaluating the level of collapse prevention of special-class structures, facility managers can easily recognize and evaluate the risk level, and this analysis result can be applied to future facility risk management. Earthquake analysis was performed so that. Conclusion: As a result of analyzing the Coalescer facility according to the current design standard KBC2016, the stress ratio of the main supporting members was found to be up to 4.7%. Therefore, the members supporting Coalescer were interpreted as being safe against earthquakes with a reproducibility period of 2400 years that may occur in Korea.

Geological Safety Evaluation and Monitoring of Nuclear Facility Sites in South Korea

  • Lee, Hyunwoo;Woo, Hyeon Dong;Chun, Hyun Ju;Im, Chang-Bock
    • The Journal of Engineering Geology
    • /
    • v.24 no.4
    • /
    • pp.609-613
    • /
    • 2014
  • The Korean Peninsula, located at the southeastern tip of the Eurasian Plate, is known to be tectonically stable, and no critical evidence has yet been found that would override the safety design of nuclear facilities in South Korea. Because a nuclear power plant, like other major social overhead capital facilities, could cause great damage to both the environment and society through an unexpected tectonic event, even one of extremely low probability, like the Fukushima accident, a defense-in-depth safety approach is required in geological and geotechnical site safety evaluation for nuclear projects. This paper introduces the regulatory procedures that are in place to confirm nuclear site safety and site monitoring (e.g., earthquakes and groundwater) systems applied to nuclear facilities in order to reduce inherent uncertainties within the site safety review of geological and seismological issues related with a NPP project.

The Survey of Construction Workers' Preference for Introducing the Emotional Safety in School Facility Construction - Focused on Emotional Safety Sensor and Emotional Facilities - (학교건축공사에 감성안전도입을 위한 근로자 선호도 조사 -감성안전센서와 감성안전 시설물 중심으로-)

  • Kim, Gwang-Hee
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.10 no.1
    • /
    • pp.26-33
    • /
    • 2011
  • The deaths caused by industrial accidents during the construction of the mortality rate is considerably higher than in other industries. To prevent such a disaster workers and to minimize unsafe behavior measures to be drawn, and construction companies recently to stimulate the emotions of the workers to participate in voluntary activities are safe. In this study, the construction workers can stimulate emotions and activities on the environment by examining the preferences of the workers on-site management will want to take advantage. This study revealed that the construction workers prefer the incentive most and then working environment.

A Study on the Temporary Storage Facility for Mitigating the Leakage Accident (누출 사고 완화를 위한 임시 저장 시설에 관한 연구)

  • Song, Hyeon Oh;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.1-5
    • /
    • 2020
  • The leakage accident from a storage tank in an oil refinery plant occurred in April 2014 and the total loss is KRW 18 billion. This accident has prompted many companies to develop their own mitigation system to minimize the loss of the leakage accident. The aim of this study is to design the temporary storage facility system for dealing with leakage accidents. The basic concept of this system is that the leakage fluid of a hazardous material flows into a temporary storage tank and this is transferred to a spare tank by a pump as avoiding the overflow of a temporary storage tank. In order to design this system, the leakage velocity and quantity according to time series should be evaluated. In addition, a proper pump capacity should be determined to avoid repeating the pump switching on and off frequently. In this study, the benzene tank is selected to verify the efficacy of this system. This study can play a critical role to provide a guideline for designing a new system.

A Study on Educational Facilities Resource Management System using Smart Devices (스마트 디바이스를 활용한 교육시설물 자원관리 시스템에 관한 연구)

  • Ryu, Chang-Su
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1013-1014
    • /
    • 2015
  • Regardless of the strict enforcement of prevention education in accordance with the school facility management standard, safety accidents that lead to human and physical damages occur in current educational facilities because of teenagers with very low sense of responsibility and insensitivity toward fire and facility safety. To ensure educational facility safety, technology that will enable a fast work process and easy confirmation of electronic blueprints and related documents about the educational facility through smart devices at the site by various means is needed. This paper proposes a system design linked to the National Education Information System (NEIS) that uses the document conversion function, high efficiency resolution, and Internet of Things (IoT) to inspect and control the educational facility in the event of a safety accident through the Educational Facility Resource Management System (EFRMS) that manages the electronic blueprints, and various educational facility documents through various smart devices.

  • PDF

A Study on the Elements of Architectural Planning Required in Healthcare Accreditation - Focused on Korea Healthcare Accreditation, JCI Hospitals Standard - (의료기관 인증제도에서 요구되는 건축계획요소에 관한 연구 - 국내 의료기관인증제도, JCI 병원인증기준을 중심으로 -)

  • Kim, Ui-Hyeon;Yang, Nae-Won
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.2
    • /
    • pp.223-230
    • /
    • 2012
  • These days, hospitals in Korea have great interests in healthcare accreditation. The criteria of this accreditation has been established by management, but development of the management system without facility improvement has limits. Therefore this study reclassified domestic and foreign healthcare accreditation focusing on facilities and has purpose on proposing facility elements that can be adopted in hospitals. Also, the study is relevant to the study on architecture planning of hospital according to 'Patient safety' which will be suggested in the future and has significance for establishing basis of healthcare facility planning and for improving the existing facilities. The study selected facility lists from 'healthcare accreditation' and reclassified them based on departments in the hospital. Using these lists, the study divided the hospital that has obtained 'healthcare accreditation' into departments and investigated and analyzed them. On the basis of the analysis, the study suggested facility lists involved in hand washing, waste disposal, equipment washing, quarantine, goods-movement, establishing clean/polluted area, emergency exit-way, and restricted zone.

  • PDF