• Title/Summary/Keyword: Facility maintenance

Search Result 873, Processing Time 0.025 seconds

Impermeable Standards for the Concrete Bottom of Dikes for Crude Oil Storage Tanks (원유저장탱크 방류벽의 콘크리트 바닥재 불침투성 세부기준 연구)

  • Shin, Changhyun;Park, Jai Hak;Yoon, Junheon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.1
    • /
    • pp.54-60
    • /
    • 2016
  • The bottom of dikes must be kept impermeable to control hazardous chemicals spilled from storage tanks. Currently, insufficient related chemical control laws lead to a possibility to spread through the bottom. Generally, due to the high cost of installation and periodical maintenance, many businesses prefer to install the bottom with general concrete. But, since the impermeability of concrete is dependent on the kind of materials and chemical reaction, all concrete cannot be considered as impermeable material. Thus, it is necessary to make the installation standards of the dike bottom clear in order to avoid the argument over the impermeability and prevent the chemical accident. This study has suggested the standards of impermeable concrete by conducting 7-day exposure test to crude oil with the pilot dikes. The results have showed that the standards have the better impermeable performance compared with the germany standard, which have been penetrated at the maximum penetration depth of 1.9 cm. This study is expected to contribute to both the risk reduction of penetrating into the bottom and the cost reduction of spending to make the bottom of dikes impermeable.

Life Cycle Cost Analysis about Renewable Energy Facilities Combination of Photovoltaic system, Solar thermal system and Geothermal system (태양광발전, 태양열 급탕, 지열시스템의 신재생에너지설비 조합에 관한 LCC 분석)

  • Chun, Sang Hyun;Ahn, Jang-Won;Kim, Wonwoo;Cho, Seung-Yun
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.105-112
    • /
    • 2012
  • When a building is planned and designed, the design should be able to minimize the cost during the whole life cycle of the building. This study has begun to analyze LCC about the alternative design which is applicable to renewable energy facility construction. It is reviewed domestic and foreign papers about the trend of LCC technology and it is determined the analytical method to analyze the LCC of renewable energy. Regarding the review of alternatives, it is chosen the three alternatives which are able to designed combing the renewable energy facilities and it is performed the LCC analysis about each alternative. Alternative 1 is Photovoltaic + Solar Thermal + Photovoltaic /Wind Power, Alternative 2 is Geothermal + Photovoltaic, and Alternative 3 is Photovoltaic + Solar Thermal. The LCC analysis is present value method, its analytical period is 40 years and it is applied 3.2% of real discount rate. As a result, it is proved that Alternative 1 and Alternative 3 are not able to collectible the early investment cost during the analytical period and Alternative 2 is analyzed that its pay-back period of early investment cost is about 31 years. As the final outcome of this study on case analysis, it is more advantageous to use the combination of Geothermal and Photovoltaic energy than to use the other combination in LCC aspect.

Development of New Back-Up Roll for Strip Shape Control (형상제어를 위한 새로운 보강롤의 개발)

  • Lee, Won-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.2
    • /
    • pp.327-333
    • /
    • 2003
  • Most of shape defects in steel strip are originated from the structure of rolling mill itself. For instance, strip crown occurs when the work roll is deformed by the bending moment induced on roll chocks. To get rids of the shape defects, it is necessary to increase the stiffness of rolling mill. The structure change of back-up roll is one of alternative ways to increase the mill stiffness without facility revamping from 4 high mill to 6 high mill. In this research work, the new back-up roll was developed and can be used in any type of 4 high mill to reduce the strip shape defects. The developed back-up roll consists of sleeve, arbor and phase angle adjusting system for arbor. The circumference of arbor is specially machined to adapt the strip width change during rolling. The experimental cold rolling test was done to prove the effectiveness of newly developed back-up roll. The experimental rolling results show that the new back-up roll has more powerful performance in reducing the shape defects than conventional back-up roll. It was also found that the new back-up roll has higher stability for shape control. In addition to, the only sleeve surface needs to be reground and changed in most cases, so that the maintenance cost can be greatly reduced.

Economies of Scale in the Sewerage Treatment Sectors of Cheonla Province Area (전라남북도 하수처리시설 운영에 대한 규모의 경제성 분석)

  • Kim, Kyunghag;Yoo, Seung-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.11-20
    • /
    • 2013
  • This Study includes the information of integrated discussion and economies of scale on local governments' sewerage treatment plant through translog function based on the reality reports of sewerage treatment plant operation published by Ministry of Environment and sewerage statistics data from 2005 to 2010. Based on analysis results from the data of 35 local governments in Jeollanamdo and Jeollabukdo, which are selected as pilot project areas of sewerage facility integration by Ministry of Environment and have low percent of sewered population, it shows the existence of economies of scale. The economies of scale on sewerage treatment show the loss of approximately 22,211 thousand ton/day in sewage treatment, it is 1.7 times compared to the average treatment amount of 35 local governments as of 2010. It means the economies of scale can be achieved by lowering operation cost along with large scale integration in installation, operation and maintenance due to the features of sewerage industry as one of network industry.

Performance Test of Wet Type Decontamination Device (습식 제염장치의 성능시험)

  • 이은표;김은가;민덕기;전용범;이형권;서항석;권형문;홍권표
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.105-108
    • /
    • 2003
  • The intervention area located at rear hot cell can be contaminated by hot cell maintenance work. For effective decontamination of the intervention floor a wet type decontamination device was developed. The device was assembled with a brush rotating part, a washing liquid supplying part, an intake part for recovering contaminated liquid and a device moving cart part. The device was made of stainless steel for easy decontamination and corrosion resistance. The function test carried out at intervention area of the PIE facility showed good performance.

  • PDF

A Practical Study of Unified Management System for Irrigation and Drainage Facilities (수리시설물 통합관리시스템 실용화 연구)

  • 김선주;박성삼
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.3
    • /
    • pp.42-53
    • /
    • 1998
  • About 50 percent of irrigation and drainage facilities in our country are deteriorated as they were constructed over 40 years ago. Worsening the problems in function might be caused by these facilities' constant exposure to the elements. With these reason, efficient maintenance and management of irrigation and drainage facili- ties are required. A computerized system is tailored on the basis of the each characteristics'data of irrigation and drainage facilities. The unified management system to be introduced in this study is a package program consisting of three subprograms. Facility Management(FM) system, the first component, is a relational database system for image processing and registering the characteristics of irrigation and drainage facilities. The objective of this program is to manage the ledger of each facilities and to scan the characteristics of facilities. Telemeter(TM) system, the second component, monitors and processes the data from the sensors statistically. This system is preprogramed for the complete design of TC/TM system. Hydrological Data Management(HDM) system, the third component, executes the hydrological analysis using meteorological data. The unified management system can provide the latest information, such as image data, lists and items of facilities, and items of reforming and rebuilding etc., of the facilities to the manager. At the same time, this system can manage hydrological and meteorological data in realtime.

  • PDF

ESS Connected PV Monitoring System Supporting Redundant Communications (통신 이중화를 지원하는 ESS연계 태양광 모니터링 시스템)

  • Joo, Jong-Yul;Lee, Young-Jae;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.29-34
    • /
    • 2018
  • The systems associated with the ESS never stop. It runs 24 hours everyday. The system must be managed to run. The ESS system should perform normally even if the power IT equipment fails or communication failure occurs. Therefore, there is a need for a system that actively addresses, manages and controls the high precision power data of the ESS, even if a variety of failures occur. I would like to propose a power management communication unit to cope with the occurrence of communication failure. This paper also includes an integrated management system that can perform micro grid site management, maintenance and monitoring for the ESS system connected with the solar power generation facility.

Development of fault detection and diagnosis system for the heat source apparatus of building air-conditioning system (공조시스템의 열원기기에 대한 고장검출 및 진단 시스템 개발)

  • Han, Dong-Won;Park, Jong-Soo;Chang, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.30-35
    • /
    • 2008
  • This paper describes a fault detection and diagnosis (FDD) system developed for the heat source apparatus in building air-conditioning system. As HVAC&R systems in building become complex and instrumented with highly automated controllers, the processes and systems get more difficult for the operator to understand and detect the mal-functions. Poorly maintained, degraded, and improperly controlled equipment wastes an estimated 15% to 30% of energy used in commercial building. When operating a complex facility, FDD system is beneficial in equipment management to provide the operator with tools which can help in decision making for recovery from a failure of the system. Automated FDD for HVAC&R system has the potential to reduce energy and maintenance costs and improves comfort and reliability. Over the last decade there has been considerable research for developing FDD system for HVAC&R equipment. However, they are being made too much of a theoretical study, so only a small of FDD methods are deployed in the field. This study deduced an actual defect source for the heat source apparatus and suggested a low price FDD method which is ready to be deployed in the field.

  • PDF

Development of Lifecycle Support Modules for the ISO 10303-AP241; Generic model for Lifecycle support of AEC facilities (AEC 시설물 공통모델(ISO 10303-AP241)의 생애주기 지원 모듈 개발)

  • An, Kyung-Ik;Kim, In-Han
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.5
    • /
    • pp.342-351
    • /
    • 2008
  • ISO 10303-AP241 is an Application Protocol of ISO 10303, which specifies the representation of AEC facility's life cycle information. The Working Draft of AP241 was submitted to the TC184/SC4 of ISO in July, 2007 by Korean team of ISO TC184/SC4/WG3. This paper introduces the currently developed draft Ap241 core model, and describes the life cycle support modules which are required to represent the life cycle information of AEC facilities. The draft core model is developed as a generic data model which is useful as a basis for implementation in a data warehouse. This core model could be used in combination with reference data such as PLCS RDL, Gellish table and RDL of ISO 15926. These concepts already exists in ISO 10303-AP221, AP239 and ISO 15926. In order to support maintenance and feedback of operational information concerning the AEC facilities, the AP241 team re-used many modules from AP239, and developed various STEP Application Modules which are adapted from the ISO 15926.

Statistical Lifetime Analysis for Large Electric Power Equipments using Failure Data (고장데이터를 이용한 대용량 전력설비 통계적 수명분석)

  • Kim, Jeong-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.11
    • /
    • pp.1605-1611
    • /
    • 2017
  • In this study, the characteristic lifetime of power facilities such as power transformers and GIS were investigated as the basis of power facility asset management. It is difficult to obtain the operation and failure data of the facilities in Korea. Therefore, the number of failures of the electric power facilities was calculated from the operation data and hazard rate shown in the overseas literatures, and the statistical analysis was performed using the Weibull distribution function. As a result of extracting and analyzing the data of the UK National Grid for power transformers, the characteristic lifetime (scale parameter) of 116.45 years was considered to be a very appropriate value for power transformer management and can be used as a comparative data of the analysis of the domestic transformers. As for the GIS, based on the Bays and Bay-Years data and the hazard rate according to the operation years of the 123kV GIS in Germany, it is found out that the characteristic lifetime of GIS is not so meaningful. It is necessary to decide a maintenance strategy and lifetime expectancy considering the characteristics of the design, materials and manufacturing process of GIS.