• Title/Summary/Keyword: Facility maintenance

Search Result 878, Processing Time 0.027 seconds

Study on Optimized Manual Development and Optimum Lighting System within Luminance-based Tunnel (휘도기반 터널내 운전자 적정조명시스템 개발 연구)

  • Lee, Mi-Ae;Kim, Yeon-Hwa;Han, Seung-Hun;Kim, Ji-Heon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.18-29
    • /
    • 2015
  • The purposes of this research and development are as follows: first, to provide pleasant driving environments inside tunnels; second, to improve the current illumination environments lacking in diffusion luminance meters to meet tunnel lighting standards; and, third, to reduce the consumption of tunnel lighting energy accounting for approximately 65% of tunnel maintenance costs because of inadequate visual environments and tunnel operations. Further details are listed below. Firstly, an image luminance meter for tunnels that can implement the L20-method which is a tunnel luminance method that follows the international standards of CIE88, which was developed in order to improve and change the existing illumination-based tunnel lighting operation system to a luminance-based system. (The margin of error of below 5% according to the results of a test by an authorized agency and field test). Secondly, early illumination control is possible since the lighting control system that can be operated based on luminance enables interlocking control of the inside and outside of a tunnel using ethernet communication. Thirdly, guidelines for field application of the system are proposed. In addition, the luminance inducers of tunnels are found and the reflexibility of each facility that may reduce luminance of the boundaries is also proposed. Fourthly, as a result of a test bed, power consumption of luminance-based lighting operations decreased by 15.6% compared to illumination-based operations. Applying the feedback controls and maintenance factors of internal/external luminance meters, it reduced by 36.4%. Therefore, we became able to provide a luminance-based lighting operation system that complies with tunnel lighting design standards and provides a visual environment for drivers.

A Study on the Efficient Bossiness Strategy for BTL Project using Sensitivity Analysis of Financial Model (재무모델 민감도분석을 이용한 BTL사업에 대한 효율적 사업전략에 관한 연구)

  • Kim, Dong-Hun;Lee, Seung-Wook;Kim, Yong-Su
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.409-414
    • /
    • 2008
  • The purpose of this study is to analyze the problem of BTL business through the sensitivity analysis of financial model and presented efficiency business strategy when private business owner propose their business. For this, we analyzed the sensitivity of financial model after analyzed costs of the school facility construction case for each place of business. The results of this study are as follows. 1)As the results of the sensitivity of financial model, requirement-earning rate for the results of analysis was decreased average 2.28 points (0.5%) per increasing 0.10% and Construction costs and the maintenance costs were decreased average 10.73 points (2.38%), 6.22 points(1.38%) for increasing 1billion won. 2) The Problem of BTL business according to the sensitivity analysis of financial model was analyzed that the price consultation low investments, and estimation from personal consideration caused it. So, it was analyzed to increase maintenance costs is more efficient method than to increase construction costs.

  • PDF

A Study on Design of Control Device on Small Wind Generator Using 2-Level Boost Converter (2레벨용 부스트 컨버터를 이용한 소형풍력발전기 제동장치 설계에 관한 연구)

  • Moon, Chae-Joo;Chang, Young-Hak;So, Soon-Youl;Park, Tae-Sik;Jeong, Moon-Seon;Youn, Young-Chan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1481-1486
    • /
    • 2013
  • The small wind generator with existing mechanical control system has a frequent failure and malfunction, and its maintenance is difficult. In this paper, an electric control method using a boost converter for small wind generator was suggested. The suggested 2-level boost converter control device was manufactured and its experimental operation were conducted on a wind generator with 200 [W] capacity. As a result of experimental device, the control by a boost converter was executed at the point that the output voltage of a wind generator became 36 [V] so it could be identified that the output voltage of a wind generator diminished and then it became 0 [V] after 5 [sec]. Besides, in case of applying the method suggested in this paper to a small wind power generation facility for street lights, it is expected to reduce its maintenance by preventing a frequent failure of a generator and to improve its utilization rate.

Design Development of Module Assembly Typed Public Facilities (모듈 조립형 공공시설물 디자인 개발)

  • Kim, Kiesu
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.650-658
    • /
    • 2013
  • In modern society, we live in the important age which should reflect needs of residents enough with the economic growth. Desire in the public sector means the basic requirements which are necessary for contemporary men who live in social life and is very important even at the social welfare policy level. Each local government is recently increasing convenience of residents by installing the facilities about public design and is politically promoting expansion of public services to satisfy their public desire. This public design should be installed to make reasonable plans and maintenance be smoothly done. This paper tries to study the present condition and the precedent studies targeting public interest facilities which will be installed in neighborhood parks of urban areas, grasp design problems of public facilities which will be installed in neighborhood space by clarifying the concept of design, and apply them by designing them newly. It tries to examine reasonable maintenance direction related to next development of public design by suggesting design direction for this practical development and module assembly typed design that storage, assembly, and management of public facilities are convenient and suggest cases of design development which can reflect them in public design development policies.

Analysis of Operating and Maintenance Parameters for Agricultural Pipeline System Using EPANET (EPANET을 이용한 농업용 관수로 시스템의 운영 및 유지관리 인자 분석)

  • Kim, Nam Do;Kim, Sun Joo;Kwon, Hyung Joong;Kim, Phil Shik;Park, Hyun Jun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.4
    • /
    • pp.17-26
    • /
    • 2017
  • In this study, EPANET model which is using on the pipe network analysis was applied to Haenam irrigation district has provided irrigation water by pipeline system about 1,125ha and then have built pipe network to study area and supply performance evaluation of existing structure was analyzed by SPA (Single Period Analysis) in EPANET. As model results of simulation average ratio of maximum supply quantity/irrigation water requirements(base demand) was analyzed by 2.63. It means also that was analyzed as being capable of ensuring the water supply capacity. It was provided the necessary information for the maintenance facility through analyzed hydraulic behaviors in the pipeline inside such as flow velocities, pressures and hydraulic grade lines. It was satisfied with the allowable design criteria that was compared analyzed results with presented allowable design standards at agricultural production infra improvement project planning and design (Pipeline design standard). In order to analyze efficiency promotions of irrigation water, using Extended Period Simulation it was compared supply quantity with irrigation water requirements while pumps set operating pattern in 24 hours, then efficiency promotions of irrigation water was determined through analyzed oversupply water quantity and occurrence time by branch lines. According to results for oversupply quantity in Haenam district by time and end of branch lines efficiency promotions of irrigation water was suggested from 0.33 % to 37.59 %. To draw reasonable operating rules for water use and through this research, it is expected to be helpful for efficient water use and operational management of agricultural pipeline system to the current agricultural irrigation.

Development of Construction Information Management Module through the Use of Vector-Photo (벡터사진 활용을 통한 시공정보 관리모듈 개발)

  • Kim, Kyoon-Tai;Lim, Myung-Gu;Kim, Gu-Taek
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.619-626
    • /
    • 2013
  • Many pictures are taken at a construction site, but the information of the pictures is not managed in an efficient and systematic manner. For this reason, when a construction worker has scant field experience or knowledge, it is hard to communicate with others efficiently. Therefore, the information of the pictures taken is not fully utilized in any deliberation or conflict among interested parties, facilities maintenance, and construction of another structure, although they were taken for those purposes. This study discusses the need for combining vector-photos with image and 5W and 1H information, and develops a prototype module for creating vector-photos and saving them in a server. The vector-photos taken can be saved to a server in real time, and efficiently managed by a DB system. If a system to link the vector-photos with a BIM model is developed in the future, it is expected that the vector information in the picture can be connected with the property information of an object. As a result, the vector-photos can be utilized in more diverse ways.

Cost Analysis of Monitoring System with Optic Fiber Sensors (광섬유센서를 이용한 모니터링 시스템의 비용 분석)

  • You, Young-Jun;Park, Ki-Tae;Joo, Bong-Chul;Lee, Chin-Hyung
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.4
    • /
    • pp.67-73
    • /
    • 2009
  • Civil infrastructure is the basis facility which builds up the base of national economy operation. Consequently unexpected sudden abnormal condition of civil infrastructure causes private and national property loss and moreover can spread social issue. Therefore, continuous maintenance and safety management for the civil infrastructures should be handled with great weight. Monitoring system for managing bridge maintenance was introduced first in the early of 1990s and has been developed up to real time measurement and analysis. Thesedays another system using fiber optic sensors is being developed. This paper presents the cost analysis of bridge monitoring system with fiber optic sensors which is gathering attention. Various cases were considered and the results were compared with that of monitoring system with electronic resistant type sensors widely used. As a results, fiber optic sensor system has good advantages in various cases, and a1so cost effectiveness compared to conventional sensor system.

  • PDF

A Study on Asset Valuation Method in Educational Facilities Delivered by BTL (BTL 사업 학교시설의 자산 가치평가 기법 연구)

  • Lee, Young-Joo;Soh, Ji-Yune;Lee, Jun-Bok;Han, Choong-Hee;Chae, Myung-Jin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.4
    • /
    • pp.40-49
    • /
    • 2011
  • A number of BTL projects for educational facilities have been augmented because of the increase of newtown development and deflationary policy of class size for learning efficiency. As the operation and maintenance costs rapidly increase, the budget for operation and maintenance is expected to be short. Therefore the asset management maximizing asset value is required to clarify the budget plan and distribution and provide a qualitatively high service. The main objective of this research is to establish asset valuation process in educational facilities delivered by BTL project. In order to meet the research objective, the asset valuation process is established by literature reviews, expert advice, and lessons learned from the developed countries. The developed process includes depreciation by internal accounting law, the core element of valuation, and asset valuation process. The results of the research will be help to offer the qualitatively high service and explain the standard of budget plan. It will assist commencing the asset management system.

A Study on Wire-rope Type Furnace Scaffolding and Its Lifting System for Large-sized Boiler (대형 보일러 와이어로프 노내비계 및 인양시스템에 관한 연구)

  • HA, Seung Woo;Lee, Tae Ho;Lee, Hae Seung;Kim, Jeung Min;You, Tai Woo;Cho, Sun Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.7
    • /
    • pp.679-683
    • /
    • 2016
  • Boilers of large-sized coal-fired power plants are being operated under very poor conditions such as continuous operation or repeating of start-up and shutdown for a stable supply of electricity. Thus periodic inspection and maintenance are required to ensure reliability of operation. The loads of existing scaffolding systems for the maintenance of boilers are concentrated in the lower parts structurally, which may cause a serial collapse of the overall scaffolding system when there are problems in some members. Therefore, in this study, a safe furnace scaffolding system is developed by dispersing the loads in the upper part, as well as minimizing the hazards of serial collapsing. In addition, for cases where the direct installation of furnace scaffolding is challenging owing to the structure of the boiler tube, a lifting system for the installation of furnace scaffolding is developed so that furnace scaffolding can be supported to secure the integrity of the power generating facility.

Characteristics of Bond Strength as Types of Primer for the Facilities of Anti-corrosion Waterproofing Materials by the Reversed Pressure and Concrete Surface Condition (내부 방수⋅방식재의 프라이머 종류별 역수압 작용 및 콘크리트 표면 상태에 따른 부착강도 특성)

  • Oh, Sang-Keun;Heo, Neung-Hoe;Shin, Hong-Chul;Choi, Sung-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.68-74
    • /
    • 2014
  • Recently, concrete facility as advanced water treatment facilities is extending in the water treatment facilities according to raise awareness of pure drinking water and delicious water. For this reason, it is increased to the necessity need to make the standard and the development of waterproofing and anti-corrosion materials for concrete structures applied water treatment tank. So, related research has become active recently. However, as the limit of research focused on durability improvement of top coating material, it is insufficient to study on the adhesion strength between the concrete surface and primer. Therefore, there is to confirm the adhesion of between concrete surface and the three primers used as anti-corrosion waterproofing materials, and to investigate the properties of adhesion strength according to the condition such as dry condition, wet condition, and water pressure condition of the concrete surface in this study.