• Title/Summary/Keyword: Facility maintenance

Search Result 872, Processing Time 0.033 seconds

The Planning of Design Guideline for New-Hanok-Style Public Buildings: Focusing on the Welfare Facilities in Apartment Complex (신한옥형 공공건축물 단지형 디자인가이드라인의 계획 방향: 공동주택단지 내 부대복리시설을 중심으로)

  • Cho, Eun Kil;Kim, Young Hoon;Kim, Won Cheon;Park, Joon Young
    • Land and Housing Review
    • /
    • v.10 no.4
    • /
    • pp.1-12
    • /
    • 2019
  • The purpose of this study is to set the direction of development of the design guideline of the New-Hanok-Style public building in apartment complex and to use it as basic data for future architecture plans. The existing Hanok architecture standards and guidelines were analyzed and the characteristics of New-Hanok-Style Public Building in apartment complex were applied. The planning direction of the design guideline was derived. First, although the criteria and guidelines related to the Hanok produced and distributed were classified differently according to the purpose of production, the details and contents were similar. Second, the general planning criteria items were divided into layout, external space plan, building plan, and performance plan. Third, the elements of 'creative inheritance of traditional architecture' and 'modern building technology', which are the characteristics of New-Hanok-Style Public Building, were applied. In addition, we analyzed elementary welfare facility guidelines and applied elements such as layout type and zoning setting. Fourth, a special planning standard for applying the building system required for the New-Hanok-Style Public Building in apartment complex was added. In the future, it is expected to revitalize New-Hanok-Style Public Building containing the unique identity(genetic factor; DNA) of the nation by developing and disseminating relevant building standards, design guidelines, and maintenance manuals.

Current Condition and Prospect of On-Site Domestic Wastewater Treatment Technologies (합병정화조 기술현황 및 전망)

  • 임연택
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.06a
    • /
    • pp.95-112
    • /
    • 1998
  • Water quality in the public water course has been polluted more seriously than ever before due to the increase of the number and aremount of pollution sources such as domestic and industrial wastewater. For water quality conservation, the Korean government has been trying to construct sewage treatment facilities continually, of which treatment capacity reached to 11,452,400m$^{3}$/day in 1996. Night soil treatment facilites of m nationwide have the treatment capacity of 24,038m$^{3}$/day. But water quality has not been improved because the sewer systems were insufficient and the treatment efficiencies of sewage were not high, enough. For renovation of water quality, miscellaneous domestic wastewater must be treated because 27g BOD/day out of total 40g BOD/person-day come from miscellaneous wastewater, comparing to 13g BOD/day from night soil. However, sole treatment purifier treat only night soil from the flushing toilet. Therefore, it may be desirable to treat the miscellaneous domestic wastewater and the night soil from flushing toilet together by joint treatment purifier system as on-site domestic wastewater treatment technology. In Korea, the joint treatment purifier system, introduced in 1997, have the benefit as follows; i) good water poiluion control effect, ii ) good effect on river water flow, iii) water pollution control with sewage treatment facility, and iv) rapid pollution control effect, etc. In order to achieve a good effect as stated before, i ) strengthening effluent guideline including BOD, nitrogen and phosphorus, ii ) specializing operation to maintain high performance, and iii) supporting its construction and maintenance costs by the governmental level may be necessary: In addition, automation system of joint treatment purifier, technology for its package and compactness, and a new bio-media bio-filter with higher capacity should be further developed in agreement with a more stringent effluent guideline.

  • PDF

BIM data mapping based on M-BDL for BIM-BEMS connection (BIM-BEMS 연계를 위한 M-BDL 기반 BIM 데이터 맵핑)

  • Kang, Tae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.348-354
    • /
    • 2018
  • This study proposes MF (Model Filter)-based M-BDL (MF-based BIM Data Linkage), which is a model filter-based data mapping method for BIM (Building Information Modeling)-BEMS linkage. Recently, BEMS (Building Energy Management System) is actively utilizing 3D spatial information. This allows the user to intuitively manage the facility energy linked to spatial information. To use BIM data in energy management systems, it is essential to link BEMS with BIM data only in terms of the user requirements. On the other hand, if the BIM is a rich dataset and is linked as it is, the user will need to manage the unnecessary information. By mapping only the data required for BEMS in heavy BIM data through M-BDL, the BIM data can be lightened and the amount of data required for maintenance can be reduced. This technology proposes a mapping method that can link the BIM data with the filtered BIM data.

Safety Review of Severe Accident Senario for Wet Spent Fuel Storage Facility (사용후핵연료 습식저장 시설의 중대사고 안전성 검토)

  • Shin, Tae-Myung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.4
    • /
    • pp.231-236
    • /
    • 2011
  • When the Fukushima nuclear power plant accident occurred in March of 2011, a hydrogen explosion in the reactor building at the 4th unit of Fukushima plants led to a big surprise because the full core of the unit 4 reactor had been moved and stored underwater at the spent nuclear fuel storage pool for periodic maintenance. It was because the possible criticality in the fuel storage pool by coolant loss may yield more severe situation than the similar accident happened inside the reactor vessel. Fortunately, it was assured to be evitable to an anxious situation by a look of water filled in the storage pool later. In the paper, the safety state of the spent fuel storage pool and rack structures of the domestic nuclear plants would be roughly reviewed and compared with the Fukushima plant case by engineering viewpoint of potential severe accidents.

Material and Deterioration Characteristic Analysis for Stone Sculptures in Gyeongbokgung Royal Palace, Seoul (경복궁 석조조형물의 재질 및 손상특성 분석)

  • Kim, Jiyoung;Jo, Young Hoon;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.29 no.4
    • /
    • pp.407-420
    • /
    • 2013
  • The stone sculptures in Gyeongbokgung Royal Palace are mainly composed of granite (884 sculptures, 96.7%) and marble (25 sculptures, 2.7%) that originated in several different quarries. Main deterioration forms are crack (24%), break-out (21%), exfoliation (36%), granular disintegration (9%) and blackening (20%). Crack and break-out are dominant contributors to high physical deterioration degree, and blackening is major weathering form of intensive discoloration. The Gyeonghoeru, Geunjeongjeon and Pumgyeseok areas require urgent and high conservation maintenance with short-term periodic monitoring since proportions of 3-grade deterioration were calculated higher than others as 55% for Gyeonghoeru, 29% for Geunjeongjeon, 11% for Pumgyeseok area. The Pumgyeseok (officials' rank stone), especially, needs intervention for protective facility due to its material vulnerability to weathering in outdoor environment.

Analysis of position accuracy of ground/underground facilities (지상ㆍ지하시설물의 위치정보 신뢰성 분석)

  • 손홍규;한춘득;김기홍;손덕재
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.11a
    • /
    • pp.405-410
    • /
    • 2004
  • In mid-90's, the Korean government introduced the GIS(Geographic Information System) to digitalize every topography of national land and thereby, index locations and attributes of various urban facilities to construct a system whereby every information could be managed and operated in an integrated way, but the reliability of such geographic information has yet to be tested, much less its modification, complementation and maintenance. Under such circumstances, this study was aimed at constructing a reference point infrastructure for Seoul and Kyonggi area and comparing the data obtained from the GPS operation and various facility location data with the existing GIS data to address the problems of GIS operation and suggest their solutions. As a result of calculating the GPS reference point data and analyzing the deviations of the unknown point data in comparison with the fixed point ones, it was found that the horizontal location values were reliable within +/- 5cm, but that the above-sea level values varied as much as 1.4m depending on the deployment of pre-set fixed points determined by the direct level gauging. In addition, as a result of directly surveying major facilities around the roads based on the coordinates of the urban reference points networked with such a reference point system to check their conformity to existing data, it was confirmed that the difference was as wide as 2m. Such differences may be attributable to the fact that the data with their geographic information not confirmed are used as basic data for GIS. Hence, this study suggests the ways to set the absolute geographic data based on reference points and test the reliability of existing data and thereby, suggests a methods to solve the problems.

  • PDF

Analytical examples of volatile amines in ambient airs (공기 중 저급아민류의 분석과 측정 사례)

  • Yu, Mee-Seon;Yang, Sung-Bong
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.216-223
    • /
    • 2005
  • In this study, several kinds of volatile amines in ambiant air were collected and their concentrations were expected from the calibration curves prepared by standard solutions of 7 amines by the official measuring method prescribed in Japanese Offensive Odor Law. The obtained calibration curves showed a good linearity and the detection limit of trimethyl amine was found to be about 0.033 ppb (0.040 ng) in case of 50 liters air. It means that trimethyl amine could be detected with the concentration of lower than its permitting level at the border line of companies. As typical examples of measuring amines in air, results of investigation of two sewage works and one rendering plant around the capital area indicated that 4 kinds of amines, i.e. methyl amine, dimethyl amine, trimethyl amine and isopropyl amine were detectable and concentrations of trimethyl amine at the primary sedimentation pond and sludge dewatering building of the sewage plant A showed 9.07 ppb and 7.79 ppb respectively, being over the concentration of odor strength 2.5, And the aeration tank, excrement input facility and indoor of maintenance room of excrement process building in the sewage plant B showed 70.0 ppb of dimethyl amine and 2.44 ppb of trimethyl amine.

A Study on Management Method of Point and Line Data Using Mobile GIS (모바일 GIS를 이용한 Point 및 Line형 데이터 갱신 방법에 관한 연구)

  • Jeon, Jae-Yong;Cho, Gi-Sung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.3
    • /
    • pp.3-10
    • /
    • 2007
  • As information communication technology matures, GIS is being evolved from wire communication GIS to mobile GIS. This is due that mobile GIS satisfy mobility, field work, speed and time. Also, this is proper that mobile GIS accomplish investigation, confirmation, input and modification operations of spatial and attribute data at field. I think mobile GIS's use is the best way. Because, Mobile GIS's use can accomplish effectively the management of various kinds facilities in city. On this study, we consider diversified methods a person in charge can management point and line data with more easy and more effective method. The management methods of pint type data are free method, offset method two point method. The management methods of line type data are free method, point connection method, point and line connection method and the minimum distance connection method between point and line.

  • PDF

A Study on Removal of Organics, Nitrogen and Phoschorus of Domestic Wastewater in Pilot-Scale Upflow Packed Bed Column Reactor (Pilot 규모의 상향류식 충전탑 반응기를 이용한 생활오수의 유기물 및 질소, 인 처리에 관한 연구)

  • Seon, Yong-Ho
    • KSBB Journal
    • /
    • v.22 no.4
    • /
    • pp.191-196
    • /
    • 2007
  • This study used biofilm process, which needs simple operation, maintenance and smaller facility area than conventional activated sludge process with the small plant operation, in the treatment of increasing sewage with the rapid industrial growth. The reactor used in this study consists of one anaerobic and one aerobic chamber filled with waste ceramic and waste vinyl as media and the treated sewage was from restaurant source. The experiment was scaled up from lab. to pilot scale and lasted for about 100 days. We focused on the removal efficiency of organics, nitrogen and phosphorus with constant HRT and continuous aeration. The removal efficiency of $BOD_5$ and SS were 94.33% and 87.77% respectively, which was a satisfaction level. However the removal efficiency of $COD_{Cr}$ was 81.46% somewhat below the desired level of 90%, and that of T-N and T-P showed 71.92% and 21.10% respectively, that was below the expected value. The removal efficiency of $COD_{Cr}$ and T-N in the pilot scale was about 10% low compared with the lab.-scale.

The consideration of development for the Speed Gate Tester applied Embedded System (임베디드 시스템을 적용한 스피드게이트 시험기 개발에 관한 고찰)

  • Yu, Sin-Cheol;Nam, Jeong-In;Lee, Gi-Seung
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.860-865
    • /
    • 2009
  • This thesis deals with application of Windows CE for Embedded System and the development methode of "Speed Gate Controller Tester" taking advantage of development program. We can improve reliability, stability and convenience of maintenance work as use of "Speed Gate Controller Tester" which was developed and applied "Embedded System" We can provide customers with more qualified service naturally because of the higher rate of operation which makes people use more pleasant and comfortable subway facility. And also it is possible to manage processor, time schedule and hardware resource as application of Embedded System and Windows CE. Embedded System applied OS Windows CE makes it possible to develop other various products, another application of equipment and tester. Thus this paper treats problems the moment developed and the present condition, development process, field application results.

  • PDF