• Title/Summary/Keyword: Facility maintenance

Search Result 872, Processing Time 0.03 seconds

A Model of Work Breakdown Structure for being applied to Historical Data in BTL Project for Educational Facilities (교육시설 BTL 사업의 실적공사비 적용을 위한 작업분류체계(WBS) 구축)

  • Kim, Sung-Kyum;Cho, Chang-Yeon;Son, Jae-Ho;Kim, Jae-On
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.499-502
    • /
    • 2007
  • The government abolished the existing method to calculate the construction price by the quantity take-off and pricing. It has introduced a new estimating system which uses the actual cost data on the basis of actual contract unit price. However, in the case of the current method to calculate the estimate price of BTL educational facilities, it is difficult to prepare an accurate ground for calculating unit prices due to a lack of standardized work breakdown structure (WBS) and guidelines for the detailed bidding documents. Thus, this research aims to establish WBS using the actual construction price on the basis of the actual bidding documents for the previous construction of BTL educational facilities. This specific WBS can be differentiated from the general WBS which is not suited for construction of the educational facility. It makes possible to build the construction information classification system and it helps to systemize the maintenance and repair cost items.

  • PDF

Post Occupancy Evaluation of the Central Hospital in Quang Nam Province of Vietnam Funded by Korean ODA (ODA 지원 베트남 중부 꽝남성 종합병원의 거주후 평가)

  • Kwon, Soon Jung;Yu, Yeo Kyoung;Kim, Jihyun;Bang, Seol Ah
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.1
    • /
    • pp.39-49
    • /
    • 2016
  • Purpose: This is the ex-post evaluation on "the Central General Hospital in Quang Nam Province in Vietnam" funded by Korean ODA. Through this evaluation, this study tries to explore useful ways to improve the effectiveness of Korean ODA projects related to hospital establishment. Methods: Field survey and analysis of questionaire to the staffs and patients of Quang Nam Province General Hospital were conducted twice in 2012 and 2014 after the completion of the Hospital. Two sets of surveys and questionaire outcomes have been comparatively analysed by statistics in order to seek the trend of satisfaction level of hospital users and find out the improvement way in hospital design and construction. Results: The satisfaction level on the hospital was relatively high and that of 2014 is higher than that of 2012. The satisfaction level of the users was recorded in Likert 5 scales. Continuous facility complement and maintenance is considered as the main contributor in increasing the satisfaction level of users. As far as the satisfaction level of outpatient is concerned, that of 2012 was recorded as 3.65 and that of 2014 was 4.05. In case of inpatient, the satisfaction level on the hospital in 2012 was 3.76, and 4.06 in 2014. Implications: In overseas hospital projects, proper hospital project management system including medical service plan, strategic plan, brief, design & construction and maintenance have to be put together effectively and efficiently for the success of the hospital project. At the same time local climate, culture, building material and local code have to be considered in order to build sustainable hospital.

Mobile monitoring system of the Dual LED marine lantern (이중 LED 등명기의 휴대용 모니터링 시스템)

  • Ye, Seong-Hyeon;Han, Soonhee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.1948-1954
    • /
    • 2014
  • Advances in IT technology and modernization of AtoN(Aids to Navigation) facility has increased the unmanned operation of AtoN. However, in AtoN facilities, accessibility is low and it is not able to perform maintenance on the bad weather at the time. In connection with this, in this paper, by applying the protocol of the enhanced dual LED marine lantern, we implemented the short-range monitoring system for a mobile terminal. System implemented in this paper can be carried out confirm the operation status, inspection or control of the dual LED marine lantern at a short distance. Also, it is possible to reduce maintenance costs and prevent accidents during inspection of AtoN. At the same time, it enables the operation test easily without disassembling the product, effective AtoN operation is possible. We tested the system that has been implemented using prototype of the LED marine lantern and confirmed state informations and controlled the behavior of the system in real time.

A Study on the Nano Silica-Sol Coating for Improving Performance of Recycled Aggregate (순환골재의 성능향상을 위한 나노실리카졸의 코팅에 관한 연구)

  • Kim, Seong-Soo;Lee, Jeong-Bae;Ko, Ji-Soo;Kim, Il-Kon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.84-90
    • /
    • 2013
  • In this study we propose an effective method, Coating processing methods, which can improve the quality of recycled aggregate relatively easily without new equipment investment and complex treatment process and verify the improved effect using the devised method, Coating processing methods. To attain the research aim we used adequately diluted silicate solution for coating and carried out several property valuation for twelve types of material with different coating method. Also we formed concrete with coated aggregates which showed the best property. In conclusion the aggregates with the method of repeated impregnation in the silicate and drying showed the most excellent quality while other coating methods also resulted in an improvement of aggregate quality but failed to meet the KS Standard. Lastly with the optimal material we could obtain the approved compressive strength from the concrete allowing it to be utilized for road facility of which standard compressive strength of design is under 24MPa.

A Study of Advance Operation and Maintenance technology for Smart Water Grid(SWG) Facility (스마트워터그리드 시설 운영 및 유지관리 고도화 실증 연구)

  • Han, Kuk Heon;Yum, Kyung Taek;Koo, Kang Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.426-426
    • /
    • 2018
  • 제 4차 산업혁명의 시대를 맞아 ICT 융합 차세대 물관리 시스템 관련 기술이 핵심적인 역할을 수행하게 될 것으로 예상되며, 이와 함께 다국적 기업의 시장 진출로 인한 경쟁심화가 예상되고 있다. 한편, 인구증가, 도시성장, 산업발전 및 기후변화에 따른 물부족, 물 수요와 물 공급의 불균형, 수질오염 등은 점점 더 심각해질 것으로 예상되고 있다. 또한, 수자원 산업에서 대상시설의 안전하고 경제적인 운영 및 유지관리를 목적으로 하는 운전, 감시, 진단, 보수, 개선 및 이를 위한 의사결정지원 기술인 운영관리(O&M, Operation and Maintenance) 기술의 중요성이 지속적으로 증가하는 추세이다. 스마트워터그리드(SWG)는 ICT 융복합 첨단 수자원 관리기술로 기후변화에 의한 물 부족과 수자원 인프라 노후화로 인한 효율저하 등 물 문제 해결을 위한 차세대 플랫폼으로 주목받고 있으나, 아직까지 스마트워터그리드 시스템 구축을 위한 장치, 부품, 공정, 설계, 시공 기술 등 주로 요소기술 확보를 목적으로 연구되었으며, 시설의 운영 및 유지관리 연구는 거의 진행되지 않아 효율적인 현장적용이 어려운 실정이다. 본 연구에서는 스마트워터그리드 데모플랜트 시설을 대상으로 운영 유지관리 기술의 고도화 기본방향, 세부 핵심기술, 추진방법 등을 제시하고자 한다. 특히 스마트워터그리드의 핵심기술인 AMI 기반 수운영 시스템을 대상으로 IoT 기반의 고효율 저비용 물 공급 체계 고도화 및 지능형 통합 운영 플랫폼 구축, Hybrid형 다중수원 활용 이동식 물 생산 시스템에 대한 운전제어 자가진단 운영관리 유지보수기술 등 원격 무인 자동화 물 생산시설 기술 고도화 개발방안에 대하여 중점적으로 다루고자 한다.

  • PDF

Selection of New High-maintenance Children's Activity Spaces based on Children's Life Patterns (어린이 활동양상 설문분석을 통한 신규관리 활동공간 검토)

  • Kim, Ho-Hyun;Choi, In-Seak;Nam, Yi-Hyun;Lee, Jeong-Hun;Yoo, Si-Eun;Park, Choong-Hee;Lee, Jung-Sub
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.2
    • /
    • pp.164-172
    • /
    • 2019
  • Objectives: This study's purpose is finding children's activity spaces that demand environmental safety management. Methods: The method of this study is analysing children's life patterns based on a questionnaire survey. Results: This study analyzed children's life patterns through a questionnaire survey. In total, 2,447 questionnaires were provided to analyze children's life patterns. The results of the questionnaire indicated a highly simple form because many children generally stayed in their home (66%) or nursery facility (2%). In the case of other facilities, playground was ranked first and amusement park was ranked second. In addition, kids cafe (including play facilities installed in shopping centers, etc.), library, and internet cafe were among the responses. Conclusions: The priority for new high-maintenance children's activity spaces are academy (rank 1), kids cafe (rank 2), indoor playground (rank 3).

Development of Evaluation Model of Pumping and Drainage Station Using Performance Degradation Factors (농업기반시설물 양·배수장의 성능저하 요인분석 및 성능평가 모델 개발)

  • Lee, Jonghyuk;Lee, Sangik;Jeong, Youngjoon;Lee, Jemyung;Yoon, Seongsoo;Park, Jinseon;Lee, Byeongjoon;Lee, Joongu;Choi, Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.4
    • /
    • pp.75-86
    • /
    • 2019
  • Recently, natural disasters due to abnormal climates are frequently outbreaking, and there is rapid increase of damage to aged agricultural infrastructure. As agricultural infrastructure facilities are in contact with water throughout the year and the number of them is significant, it is important to build a maintenance management system. Especially, the current maintenance management system of pumping and drainage stations among the agricultural facilities has the limit of lack of objectivity and management personnel. The purpose of this study is to develop a performance evaluation model using the factors related to performance degradation of pumping and drainage facilities and to predict the performance of the facilities in response to climate change. In this study, we focused on the pumping and drainage stations belonging to each climatic zone separated by the Korea geographical climatic classification system. The performance evaluation model was developed using three different statistical models of POLS, RE, and LASSO. As the result of analysis of statistical models, LASSO was selected for the performance evaluation model as it solved the multicollinearity problem between variables, and showed the smallest MSE. To predict the performance degradation due to climate change, the climate change response variables were classified into three categories: climate exposure, sensitivity, and adaptive capacity. The performance degradation prediction was performed at each facility using the developed performance evaluation model and the climate change response variables.

Field Model Test of the Non-power Soil Cleaning System (무동력 토사제거시스템의 현장모형실험)

  • Park, Chan Keun;Lee, Young Hak;Hong, Seok Min;Lee, Dal Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.4
    • /
    • pp.63-73
    • /
    • 2019
  • Coastal and fishing facilities are gradually deteriorating in function due to the continual accumulation of soil sediments, which has affected local economic activities. Currently, there are many methods to remove soil sediments, but these methods are either a temporary solution or require a repetitive removal of the soil sediments, which is a huge financial burden for the maintenance of the facilities. To solve these problems, this study proposed a non-power soil cleaning system and evaluated field applicability by carrying out field model tests. The conditions for the evaluation focused on the drainage-elapsed time and drainage-outflow velocity according to the water level change in the water tank. In the field test, silty clay and sand were separately installed, and sedimentation soil removal test was practiced. As a result, the system was verified to have a sufficient outflow velocity for the removal of soil sediments. In addition, a generalization equation that can be used in different regions of the tide was suggested in this study. These results will greatly contribute to removing soil sediments in ports and dike gate facilities on the southwest coast. Since the system is an eco-friendly technology that does not require additional energy, thus it is expected to contribute to maintenance of sustainable facility performance as well as economic effect in the future.

A Study on the Verification of water level criteria for forecasting system of reservoir failure (저수지 붕괴예보 시스템의 수위기준 검증 연구)

  • Lee, Baeg;Choi, Byounghan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.51-55
    • /
    • 2019
  • The loss of safety for reservoirs brought about by climate change and facility aging leads to reservoir failures, which results in the loss of lives and property damage in downstream areas. Therefore, it is necessary to provide a Reservoir Failure Forecasting System for downstream residents to detect the early signs of failure (with sensors) in real-time and perform safety management to prevent and minimize possible damage. For the verification of established water level management criteria, 10 water level data up to reservoir capacity was selected. Weight factor and trend line were applied to dramatic increase section of water level in the 1 year period data. The results shows that water level criteria based on three even parts shows less than 7% of standard deviation and it is appropriate to verify management criteria.

Design of a Planar Log-Spiral Antenna for Testing Plane-Wave Shielding Effectiveness (평면파 차폐효과 시험용 평판형 로그 스파이럴 안테나 설계)

  • Chung, Yeon-Choon
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.762-767
    • /
    • 2019
  • The plane-wave shielding effectiveness is typically measured for horizontal and vertical polarizations using a linearly polarized antenna. However, this typical measurement method results in big evaluation fees due to very long measurement time as well as huge idle space for maintenance, these problems is more severe especially in large shielded enclosures such as EMP protection facilities to be built in indoor buildings and underground. This paper describes the design and fabrication process and results of a planar log-spiral antenna applicable to the evaluation of the electromagnetic shielding effectiveness of a large EMP protection facility. Since the proposed antenna has a circular polarization, there is no need to separately measure the horizontal and vertical polarizations. Therefore, the measurement time can be shortened by more than 1/2, and further, its small volume with a planar structure can reduce greatly idle space required for the maintenance.