• Title/Summary/Keyword: Facility maintenance

Search Result 872, Processing Time 0.025 seconds

A Study on Quality Level of Underground Spacial Information for Accuracy Improvement (지하공간정보 정확도 향상을 위한 품질등급제 연구)

  • Kim, Wondae;Lee, Kang Won;Kim, Tae Hoon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.3
    • /
    • pp.167-177
    • /
    • 2021
  • Facilities located in the underground space are closely related to the sanitation and safety of the city, and the underground spatial information is precisely constructed and used as important information for facility maintenance, safety, and underground space development. In this study, a method was studied to increase the field usability by increasing the reliability of underground spatial information constructed in Korea and used in the field. For this study, the current status of the construction of underground spatial information in Korea was summarized, and cases of the underground spatial information quality grading system applied in the US, UK, Canada, France, and Australia, which are advanced geospatial information countries, were investigated. In terms of field usability, a questionnaire was conducted on the systems, standards, and management methods related to underground spatial information of field experts and consumers working in related fields in Korea, and statistical analysis was conducted to analyze the relevance of the introduction. Through this study, it was concluded that it is necessary to introduce a quality grading system according to the construction method of underground spatial information, accuracy and reliability, and to improve related systems and regulations.

Development of noise mapping system to manage the interior room noise of power plants (발전소의 실내 소음관리를 위한 소음 매핑 시스템 개발)

  • Kim, Young-Il;Kim, Won-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.92-98
    • /
    • 2021
  • The noise management in the interior of the power plant is difficult because the interior is large and the noise level varies greatly from location to location. Therefore, a noise visualization system capable of analyzing the noise distribution is required in order to effectively manage the interior noise. A noise mapping system was developed that can model the inside of the turbine room and create a noise map by measuring the noise level at selected points. And in order to increase the reliability of the model, the model was modified through a method of comparing the noise map and the actual noise measurement results. Facility abnormalities can be determined through regular analysis of noise maps, and a method of effectively managing the interior noise is presented by comparing and analyzing the frequencies and levels of the current and previous noise at a specific point. By using the mapping system, it is possible to establish noise countermeasures that can improve the working environment, check the machine for abnormalities, and increase the reliability of the facility through preventive maintenance.

Design of particulate matter reduction algorithm by learning failure patterns of PHM-based air conditioning facilites

  • Park, Jeong In;Kang, Un Gu
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.7
    • /
    • pp.83-92
    • /
    • 2022
  • In this paper, we designed an algorithm that can control the state of PM by learning the chain failure pattern of PHM based air conditioning facility. It is an inevitable spread of PM due to the downtime caused by the failure of the air conditioning facility. The algorithm developed by us is to establish a PM management system through PHM, and it is an algorithm that maintains a constant stabilization state through learning the stop/operation pattern of the air conditioner and manages PM based on this. As a result of the simulating at a subway station for the performance qualification of the algorithm, it was verified that the concentration of PM reduces by 30% on average. In the case of stations with many passengers using the subway, the concentration of PM exceeded the Ministry of Environment Standards(100 ㎍/m3), but it was verified that the concentration of PM was improved at all stations where the simulation was conducted. In the future research is to expand the system to comprehensively manage not only PM but also pollutants such as CO2, CO, and NO2 in subway stations.

Strategic Improvement of Harbor Floating Pier Facilities (항만부잔교시설의 전략적 운영 개선 방안)

  • Park, Doo-Jin;Kim, Jung Yee;Kim, Woo-Sun
    • Journal of Korea Port Economic Association
    • /
    • v.37 no.3
    • /
    • pp.105-116
    • /
    • 2021
  • Harbor floating pier is a structure in which one or several floating vessels are connected to have a port function so that ships can be bordered regardless of tide level in places where differences between tidal rocks are severe. There are 233 harbor floating piers in Korea, and 27.5% of harbor floating pier are over 30 years old. Harbor floating piers older than 30 years are potentially at high risk of accidents. However, there is no clear standard for disposal or sale of aging harbor floating pier, and the management regulations on the timing of maintenance inspection and repair are ambiguous. In this study, the AHP model was designed by classifying the problems and improvement factors of harbor floating pier facility operation through interviews with port managers and existing literature studies. The AHP analysis showed that the relative importance of the evaluation factors of the higher class was in the order of improvement of the legal system, improvement of operational management and technical improvement. This study can be used as basic data for improving the operation of Korea harbor floating pier facilities.

A Study on the Hazard and Risk Analysis of Hospital in Korea - Focused on Local Medical Centers (의료기관의 위험도 분석 조사 - 지역공공의료원을 중심으로)

  • Kim, Youngaee;Song, Sanghoon;Lee, Hyunjin;Kim, Taeyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.31-39
    • /
    • 2022
  • The purpose of this study is to analyse the hazard risk by examining the magnitude and severity of each type of hazard in order to mitigate and prepare for disasters in medical facilities. Methods: The hazard risk analysis for hazard types was surveyed for team leaders of medical facilities. The questionnaire analyzed data from 27 facilities, which were returned from 41 Local Medical Centers. Results: When looking at the 'Risk' by category type of hazard, the influence of health safety and fire/energy safety comes first, followed by natural disaster, facility safety, and crime safety. On the other hand, as for 'Magnitude', facility safety and crime safety come first, followed by health safety, fire/energy safety, and natural disasters. Most of the top types of disaster judged to have high hazard in medical facilities are health types. The top five priorities of hazard in medical facilities, they are affected by the geographical and industrial conditions of the treatment area. In the case of cities, the hazard was found to be high in the order of infectious disease, patient surge, and wind and flood damage. On the other hand, in rural areas, livestock diseases and infectious diseases showed the highest hazard. In the case of forest areas, the hazard was high in the order of wildfire, fire accident, lightning, tide, earthquake, and landslide, whereas in coastal areas of industrial complexes, the hazard was high due to fire, landslide, water pollution, marine pollution, and chemical spill accident. Implications: Through the research, standards will be established for the design of hospitals with disaster preparedness, and will contribute to the preparation of preemptive measures in terms of maintenance.

Complex Disaster Risk Assessment of Local Road using a Landslide Hazard Map (산사태위험지도를 이용한 도로중심 복합재난 위험도 평가)

  • Kim, Min-Ho;Jang, Chang-Deok;Jun, Kye-Won
    • Journal of Korean Society of Disaster and Security
    • /
    • v.15 no.3
    • /
    • pp.31-40
    • /
    • 2022
  • Domestic disaster risk maps are mainly produced and studied as a single disaster map by grid unit and disaster type. In particular, it is necessary to present an evaluation method of the disaster risk map that is more suitable for the relevant facility (local road) in order to utilize the work of practitioners who are mainly in charge of facility maintenance. In this study, an evaluation method was presented to evaluate the risk with a focus on local roads by using the landslide risk map and debris flow risk map provided by the Korea Forest Service. In addition, the risk was evaluated and verified for the provinces located in Gangwon-do. As a result of the evaluation, it was possible to evaluate the risk of grades 1 to 5 for 1,513 evaluation sections in the evaluation section with a total length of 234.59 km.

A Re-discussion on the Construction and Identity of Gwallamji Pond in the Rear Garden of Changdeokgung Palace (창덕궁 후원 관람지(觀纜池)의 조영과 실체에 관한 재고(再考))

  • Oh, Jun-Young
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.40 no.4
    • /
    • pp.32-48
    • /
    • 2022
  • This study analyzed the construction pattern and historical reality of Gwallamji Pond(觀纜池) in the rear garden of Changdeokgung Palace(昌德宮), which has been received as distorted information and has not received sufficient attention. The main topics consisted of the construction period and reorganization in the pond garden, changes in the installed wooden bridge, the existence of the berthing facility, and whether the plan shape was deformed. The main results of this study can be summarized as follows. First, the Gwallamji Pond was already completed before the Gapsin Coup, which occurred in the year of King Gojong. Since then, the Gwallamji Pond area, including the surrounding facilities, has been neglected for a while and was extensively renovated in the early 1900s. It is difficult to find a clear basis for the suspension and resumption of the Gwallamji Pond construction proposed in the previous discussion. Second, three types of wooden bridges with different shapes and structures were installed sequentially in the Gwallamji Pond. In particular, the second wooden bridge, which installed after the maintenance of the Gwallamji Pond, is judged to be the pontoon bridge depicted in Donggweoldohyeong(東闕圖形), and the railing of the bridge was decorated to symbolize the imperial family of the Korean Empire. The third wooden bridge, which appeared intensively in Japanese colonial era, was a Japanese-style bridge. Third, a berth facility for boarding and disembarking existed on the eastern shore of the Gwallamji Pond. The berth facility is also described in Donggweoldohyeong and it remained until the Japanese colonial period. However, as the maintenance work of the Gwallamji Pond was carried out several times after liberation, the berth facility was gradually damaged, and there are no traces left now. Fourth, The Gwallamji Pond was originally constructed in a planar shape of the Korean Peninsula similar to the present. It is necessary to reconsider the conventional theory that the Gwallamji Pond, made in the shape of a gored-shaped bottle, was renovated in the shape of the Korean Peninsula in Japanese colonial era. Even when the term Pandoji Pond(半島池) first appeared, there was no view that the Japanese intentionally modified the Gwallamji Pond.

Study on Optimized Manual Development and Optimum Lighting System within Luminance-based Tunnel (휘도기반 터널내 운전자 적정조명시스템 개발 연구)

  • Lee, Mi-Ae;Kim, Yeon-Hwa;Han, Seung-Hun;Kim, Ji-Heon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.18-29
    • /
    • 2015
  • The purposes of this research and development are as follows: first, to provide pleasant driving environments inside tunnels; second, to improve the current illumination environments lacking in diffusion luminance meters to meet tunnel lighting standards; and, third, to reduce the consumption of tunnel lighting energy accounting for approximately 65% of tunnel maintenance costs because of inadequate visual environments and tunnel operations. Further details are listed below. Firstly, an image luminance meter for tunnels that can implement the L20-method which is a tunnel luminance method that follows the international standards of CIE88, which was developed in order to improve and change the existing illumination-based tunnel lighting operation system to a luminance-based system. (The margin of error of below 5% according to the results of a test by an authorized agency and field test). Secondly, early illumination control is possible since the lighting control system that can be operated based on luminance enables interlocking control of the inside and outside of a tunnel using ethernet communication. Thirdly, guidelines for field application of the system are proposed. In addition, the luminance inducers of tunnels are found and the reflexibility of each facility that may reduce luminance of the boundaries is also proposed. Fourthly, as a result of a test bed, power consumption of luminance-based lighting operations decreased by 15.6% compared to illumination-based operations. Applying the feedback controls and maintenance factors of internal/external luminance meters, it reduced by 36.4%. Therefore, we became able to provide a luminance-based lighting operation system that complies with tunnel lighting design standards and provides a visual environment for drivers.

A Study on the Efficient Bossiness Strategy for BTL Project using Sensitivity Analysis of Financial Model (재무모델 민감도분석을 이용한 BTL사업에 대한 효율적 사업전략에 관한 연구)

  • Kim, Dong-Hun;Lee, Seung-Wook;Kim, Yong-Su
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.409-414
    • /
    • 2008
  • The purpose of this study is to analyze the problem of BTL business through the sensitivity analysis of financial model and presented efficiency business strategy when private business owner propose their business. For this, we analyzed the sensitivity of financial model after analyzed costs of the school facility construction case for each place of business. The results of this study are as follows. 1)As the results of the sensitivity of financial model, requirement-earning rate for the results of analysis was decreased average 2.28 points (0.5%) per increasing 0.10% and Construction costs and the maintenance costs were decreased average 10.73 points (2.38%), 6.22 points(1.38%) for increasing 1billion won. 2) The Problem of BTL business according to the sensitivity analysis of financial model was analyzed that the price consultation low investments, and estimation from personal consideration caused it. So, it was analyzed to increase maintenance costs is more efficient method than to increase construction costs.

  • PDF

A Study on Design of Control Device on Small Wind Generator Using 2-Level Boost Converter (2레벨용 부스트 컨버터를 이용한 소형풍력발전기 제동장치 설계에 관한 연구)

  • Moon, Chae-Joo;Chang, Young-Hak;So, Soon-Youl;Park, Tae-Sik;Jeong, Moon-Seon;Youn, Young-Chan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1481-1486
    • /
    • 2013
  • The small wind generator with existing mechanical control system has a frequent failure and malfunction, and its maintenance is difficult. In this paper, an electric control method using a boost converter for small wind generator was suggested. The suggested 2-level boost converter control device was manufactured and its experimental operation were conducted on a wind generator with 200 [W] capacity. As a result of experimental device, the control by a boost converter was executed at the point that the output voltage of a wind generator became 36 [V] so it could be identified that the output voltage of a wind generator diminished and then it became 0 [V] after 5 [sec]. Besides, in case of applying the method suggested in this paper to a small wind power generation facility for street lights, it is expected to reduce its maintenance by preventing a frequent failure of a generator and to improve its utilization rate.