• Title/Summary/Keyword: Facility maintenance

Search Result 872, Processing Time 0.026 seconds

A Study on the Direction of Restructuring of Educational Facility Management Operating System (학교 교육시설관리 지원시설 업무체계 재구조화 방안 연구)

  • Kim, Young-Bong;Lee, Yong-Hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.21 no.4
    • /
    • pp.21-28
    • /
    • 2022
  • This study analyzes the reality of the overall operating system, such as recognition and satisfaction with school field support work system of the Education Facilities Management Center, recognition level of restructuring of work areas, and the direction of improvement for school facility maintenance support in various types of future learning environments. To analyze the problem of this study, a survey was conducted on 290 education administrative officials in Gyeonggi-do. First, school site awareness and work performance satisfaction of the Educational Facilities Management Center were evaluated as "below average," and it is necessary to improve the qualitative work area that is practically helpful to schools. Second, in the area of organizational operation, it is desirable to avoid simple tasks with a low evaluation of "below average" and to switch to an operating system that improves efficiency. Third, the need for the facility environment area (professionalism, safety) was the highest, but the center's ability and work processing level were evaluated very low as "below average," so it is urgent to improve the center's capacity. Fourth, in the area of social and educational policy change, the center received a high score for the need for access from the perspective of a learning environment linked to future education. Therefore, a policy review on the restructuring and improvement of work areas suitable for this is necessary.

A Study on Facility Changes according to Changes in the Urban Park Type in Korea - Focus on Parks in Seoul - (국내 도시공원 유형변경에 따른 시설변화 연구 - 서울시 공원을 중심으로 -)

  • Ko, Ha-jung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.2
    • /
    • pp.76-88
    • /
    • 2022
  • Urban parks play the role of providing leisure spaces for people in their everyday life along with serving ecological functions in the city. Although urban parks aim to satisfy the needs of users visiting the park, most urban parks are currently uniformly created and maintained without considering the environmental characteristics based on the needs of users. This study thus analyzed parks that underwent modifications in line with the revised Park Act in 2005. There were 45 parks whose types were legally changed, of which 21 were changed from children's parks to small parks, and 19 were changed to utilize and highlight the themes such as cultural parks and historical parks. Among the parks whose types have changed, the ratio of amenities in cultural and historic parks has increased, while the facility area in small parks has decreased and the green area has increased in its place. As a result of analyzing the changes to the park facility area, it was confirmed that increasing park amenities has a positive effect in pursuing revitalization of use through park maintenance, but has a negative consequence of significantly decreasing green area. It is necessary to reorganize the park type classification system to reflect the park environment and prepare guidelines for a new installation standard by park type to expand the net function of parks in cities and maintain the sustainable ecological environment. Through in-depth discussions on the facilities of park types, it is anticipated that innovative and multilateral research could be conducted to prepare improvement measures tailored to the guidelines of urban park types in years to come.

A Study on the Prediction of Buried Rebar Thickness Using CNN Based on GPR Heatmap Image Data (GPR 히트맵 이미지 데이터 기반 CNN을 이용한 철근 두께 예측에 관한 연구)

  • Park, Sehwan;Kim, Juwon;Kim, Wonkyu;Kim, Hansun;Park, Seunghee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.66-71
    • /
    • 2019
  • In this paper, a study was conducted on the method of using GPR data to predict rebar thickness inside a facility. As shown in the cases of poor construction, such as the use of rebars below the domestic standard and the construction of reinforcement, information on rebar thickness can be found to be essential for precision safety diagnosis of structures. For this purpose, the B-scan data of GPR was obtained by gradually increasing the diameter of rebars by making specimen. Because the B-scan data of GPR is less visible, the data was converted into the heatmap image data through migration to increase the intuition of the data. In order to compare the results of application of commonly used B-scan data and heatmap data to CNN, this study extracted areas for rebars from B-scan and heatmap data respectively to build training and validation data, and applied CNN to the deployed data. As a result, better results were obtained for the heatmap data when compared with the B-scan data. This confirms that if GPR heatmap data are used, rebar thickness can be predicted with higher accuracy than when B-scan data is used, and the possibility of predicting rebar thickness inside a facility is verified.

Current State and Improvement Measures of HACCP System Applying in Elementary School Lunch (HACCP 적용 초등학교급식에서의 시행실태와 개선방안)

  • Woo, Gun-Yeon;Park, Jae-Yong;Han, Chang-Hyun
    • Journal of the Korean Society of School Health
    • /
    • v.16 no.2
    • /
    • pp.13-23
    • /
    • 2003
  • To provide data necessary for effectively applying the HACCP system by understanding the current application condition of HACCP system and satisfaction level of the dietician in elementary schools, a mail-in survey was conducted on dieticians serving for 227 elementary schools applying HACCP system in Kyungsangbuk-Do since November 1, 2001 to December 20, 2001. 83.5% of the subjected schools were conducting more than 50% of HACCP cooking process management, and the level of cooking process management displayed significant relevance according to the number of dieticians serving the school meals. The area that was not well conducted in the field of HACCP system was proven to be water examination(94.0%), inspection on self-sanitation of cooks prior to cooking(90.6%), and maintenance of dry kitchen floor(l4.8%). The reason why the above areas are not well conducted was because of lack of time due to over workloads. Subjective dieticians had pointed out improvement of sanitary concept(58.1%) and improvement of self-sanitation (28.8%) as benefits of applying HACCP. 21.2% of the subjective dieticians were satisfied with application HACCP and 35.2% were dissatisfied with applying HACCP. In case of which the duration of applying the HACCP was longer than one year and in case of higher rate of HACCP cooking process management and longer work experience of the dieticians, the level of satisfaction was proven to be significantly higher. The most difficult things to follow in important management categories according to the features of dietitian work and work experience were food distribution of CCP7 step and maintenance of optimum temperature(70.7%). Subjective dieticians had pointed out insufficient facility or environment and lack of inspection equipments in order regarding problems of applying HACCP. Also in the level of necessity of improvement categories in applying HACCP, dieticians had replied that facility and equipment improvement was mostly needed. Due to the induction of HACCP system in school meals, comparatively well cooking process management is being conducted, and I believe it could contribute in securing safety and quality improvement of school meal by improving the sanitation concept of the dieticians. However, the satisfaction level of dieticians are rather low and there are many difficulties in maintaining optimum temperature in the process of food distribution and transportation process. Also, lack of facilities and environment, lack of inspection equipments and etc are pointed out as problems of inducing HACCP. Thus, to settle HACCP system, it is believed that brave investment must be preceded.

An Estimation Model for the Replacement Parts based on the Operational Availability of Hi-Pass System (하이패스 운용가용도를 이용한 부품의 교체 추정 모델)

  • Hwang, Eui-duk;Heo, Seo Jeong;Kim, Chang Suk;Cheul, Son Dong
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.6
    • /
    • pp.285-291
    • /
    • 2015
  • FTMS, TCS, ITS equipment such as high-pass highway are just a situation that does not lack traceability and passive surveillance is related to fault DB has so far consisted of an integrated operations management to maximize utilization of the facility. In addition, there is no replacement parts are replaced when a failure occurs, increasing the number of parts and repair time I have trouble growing, and becoming a service interruption whenever you replace each time. In this study, proactively manage the failure history of a highway facility ITS tries to preventive maintenance. Therefore, the error history is based on the reliability of the high-pass facilities theory to calculate the reliability of the system through a systematic statistical analysis Operational Availability. The fault number and the time the replacement period through the estimate decreases and can reduce the budget expenses by securing the spare parts quantity, establish a management plan in part by improving the quality of the system through constant preventive maintenance, quality of service at all times It may direct the non-stop operation state of the available state.

A Study on the Application Ratio by the New and Renewable Energy Systems Fit for Public Medical Facilities (공공의료시설에 적합한 신재생에너지시스템의 복합적용비율에 관한 연구)

  • Hong, Jun-Ho;Lee, Yong-Ho;Cho, Young-Hum;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.2
    • /
    • pp.32-43
    • /
    • 2014
  • This study set out to identify the importance of each factor influencing facility selection with a survey among public medical facilities under the category of public buildings and apply the importance of economy, technology and environment with the weighting factor method, thus proposing optimal application plans. The research content of each section can be summarized as follows:1) Estimated energy consumption according to the energy simulation was 65,129MWh/yr, which was 18.7% higher than that according to the calculation equation. Of the energy consumption, more than 80% was used by heating and cooling facilities and construction facilities, and 20% was used by electronics such as medical equipments and in and outdoor lighting. 2) The results of a survey on the factors influencing the importance when selecting a new and renewable energy system reveal that the upper items had a priority in economy, environment, and technology in the descending order and that the lower item shad a priority in initial investments, maintenance and repair costs=energy costs, supply reliability, energy efficiency and $CO_2$ emissions in the descending order. 3) The application alternatives were analyzed in economy, technology, and environment. As a result, a geothermal system turned out to be the most excellent one a cross all the upper and lower comparison items. Of the other systems, a solar thermal system was superior in initial investments, maintenance and repair costs, and energy efficiency, where as a photovoltaic system was superior in energy costs, supply reliability, and $CO_2$ emissions. 4) As for the mixed application ratio among economy, technology, and environment, when the percentage of a geothermal system was approximately 80% or higher in anew and renewable energy system, it was the best and most optimal application plan.

Trail Deterioration in Woraksan National Park (월악산국립공원 등산로의 훼손실태 분석)

  • Kwon Tae-Ho;Kim Dong-Wook;Lee Joon-Woo
    • Korean Journal of Environment and Ecology
    • /
    • v.19 no.2
    • /
    • pp.130-138
    • /
    • 2005
  • The purpose of this study is to analyze the trail deterioration conditions and to obtain the informations for the desirable maintenance and restoration of the trails in Woraksan National Park. To accomplish the purpose, not only trail condition such as altitude, entire width, bare width, maximum depth and slope of trail, but also deterioration types of trail were surveyed at the total 111 points for 13.5km in length on the four access trails to Yeongbong which is the main peak of Woraksan. Furthermore, impact rating class, which could be effective means to check the step and extent of deterioration process, was judged on each points of trail. Results informs us that the deterioration condition of the trail in Woraksan National Park is not reached the lev- el of grave concern yet, but the active counterplan to change over from the safety-centric facility station to the integrated and organized restoration aiming to natural environment conservation is urgently needed.

Comparison Analysis of Ready to Use Time Depending on The Type of Public Fire Hydrant of Fire-fighting Water Facility (소방용수시설의 공설소화전 종류에 따른 사용 준비시간 비교분석)

  • Jeon, Jai-In;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.4
    • /
    • pp.87-92
    • /
    • 2019
  • The purpose of this study is to investigate the preparation time of fire-fighting water for public fire hydrants and ground, underground fire hydrants. The equipment preparation time for stage 1 was 20.50 seconds for ground type and 24.67 seconds for underground type. The reason for this difference in preparation time is that an underground fire hydrant requires additional standpipes to connect to the main conduit of Paru and the underground hydrant, which open the manhole cover. Water tank Maintenance joint with water hose male coupling of the second stage was similar to that of the ground type of 48.50 seconds and underground water tipe of 49.00 seconds. This is because the operation of connecting the fire hose to the maintenance tank of the water tank car is the same. In the third stage, the water pipe connection was 43 seconds for ground type and 174.33 seconds for underground type. The reason why the time for connecting the water pipe to the fire hydrant is large difference is that the underground fire hydrant is opened by opening the manhole cover, After connecting the stand pipe to the fire hydrant, the additional process of connecting the water pipe to the stand pipe is required, which is considered to have greatly increased the time required. The opening of Water Control Valve and spindle Valve in the fourth stage was 66.50 seconds for the ground type and 78.83 seconds for the underground type. This difference is due to the fact that the spindle of the ground fire hydrant is located on the main body and can be easily opened, but the underground type is located next to the main body under the manhole and requires additional time to connect the opening equipment.

Methodology for Estimating the Probability of Damage to a Heat Transmission Pipe (열수송관 파손확률 추정 방법론 개발)

  • Kong, Myeongsik;Kang, Jaemo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.11
    • /
    • pp.15-21
    • /
    • 2021
  • Losses of both life and property increased from damage to underground pipe such as heat transmission pipe buried underground in downtown because pipes are gradually aging. Considering the characteristics of the heat transmission pipe, which is not exposed to the outside and difficult to immediately identify problems such as damage, it is realistic to indirectly check the condition of the facility based on the historical information that is periodically collected through facility maintenance. In this study, a methodology for estimating the damage probability was developed by examining the history information of the heat transmission pipe, deriving an evaluation factor that is related to the damage probability. The contribution factor of the damage probability were reviewed by analyzing not only the guidelines for maintenance of heat transmission pipe of advanced European countries and domestic district heating companies, but also the cases of waterworks with similar characteristics. Evaluation factors were selected by considering not only the correlation with the damage probability but also the possibility of securing data. Based on 1999, when the construction technology and standards of heat transmission pipe changed, the damage probability estimation function according to the period of use was divided into the case of being buried before 1998 and the case of being buried after 1999, and presented. In addition, the damage probability was corrected by assigning weights according to the measured data for each evaluation factor such as the diameter, use, and management authority.

Current Quality Control Practices of Primary Care Clinics Participating in the National Cancer Screening Program in Korea (의원급 국가암검진기관 질 관리 현황)

  • Lee, Hyewon;Park, Bomi;Han, Kyu-Tae;Her, Eun Young;Jun, Jae Kwan;Choi, Kui Son;Suh, Mina
    • Quality Improvement in Health Care
    • /
    • v.26 no.2
    • /
    • pp.86-94
    • /
    • 2020
  • Purpose: This study aimed to identify current quality control (QC) practices of primary care clinics participating in the National Cancer Screening Program (NCSP) in Korea. Methods: A nationwide survey using a structured questionnaire was conducted among the primary care clinics participating in the NCSP, which were selected by a proportionate stratified sampling. The questionnaire consisted of general information about the responding clinics and the scope of QC activities undertaken. A total of 360 clinics responded and the set of data was then analyzed with Chi-square test and multivariable logistic regression analysis. Results: Among 360 respondents, 332 (92%) reported that they were involved in the QC activities. Most frequently performed QC activities were 'maintenance of facility and instruments' (89%) and 'staff training' (85%). The analysis revealed, with statistical significance (p<.05), that there was an association between certain characteristics of the clinics and the scope of QC activities. These findings also indicated that the diversity of QC practices varies according to the size of the clinics. The clinics screening more types of cancer, those with more screenees, and those with more employees were more likely to implement various QC activities including 'maintenance of facility and instruments', 'external quality control', and 'management of screening data'. Conclusion: To our knowledge, this is the first study to investigate the current status of QC activities conducted among primary care clinics participating in the NCSP. The results of this survey can be used as a basis for further development of policies on quality management of small- and medium-sized primary care clinics in Korea. However, further studies encompassing various aspects of QC activities and management of primary care clinics are needed to assess the current situation in a concise manner.