• Title/Summary/Keyword: Facility factor

Search Result 805, Processing Time 0.035 seconds

A Study on Demand calculation for facility design of Complex Transfer Center (복합환승센터의 시설설계를 위한 수요산정에 관한 연구)

  • Kim, Yeon-Woong;Jo, Chang-Hee;Kim, Si-Gon
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.722-729
    • /
    • 2010
  • Deciding peak-time demand will be most important factor to decide facilities' capacity of complex transfer centers. Concentration of demand is growing more and more in urban railroad that has 3 minutes headway by using MOE of 15 minutes demand. It is far from reality. Moreover there are various demand and reflection of business facilities' demand and commerce facilities' demand is being requested in complex transfer centers. This study focused on it and suggested demand calculation method about facility design of complex transfer centers.

  • PDF

Monitoring System to Measure the Waste Volume of Landfill Facility using 3D Laser Scanner (3D 레이저 스캐너를 이용한 매립장의 체적 계측을 위한 모니터링시스템)

  • Cho, Sung-Youn;Lee, Young-Dae;Ryu, Seung-Ki
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.135-140
    • /
    • 2013
  • In this paper, we discussed about the volume monitoring system of a landfill facility. We proposed the waste volume calculation method using the point cloud of the surface of three dimensional object by measurement of the point cloud by the three dimensional scanner, which is based upon the robot technique. This computes not only the quantity of waste volume for continuos monitoring but also it helps not only to predict the evaluation factor of the usable age of a landfill. facility. Furthermore, the measuring system of waste volume was applied to the landfill facility in Ansung city.

Field measurements of natural periods of vibration and structural damping of wind-excited tall residential buildings

  • Campbell, S.;Kwok, K.C.S.;Hitchcock, P.A.;Tse, K.T.;Leung, H.Y.
    • Wind and Structures
    • /
    • v.10 no.5
    • /
    • pp.401-420
    • /
    • 2007
  • Field measurements of the wind-induced response of two residential reinforced concrete buildings, among the tallest in the world, have been performed during two typhoons. Natural periods and damping values have been determined and compared with other field measurements and empirical predictors. Suitable and common empirical predictors of natural period and structural damping have been obtained that describe the trend of tall, reinforced concrete buildings whose structural vibrations have been measured in the collection of studies in Hong Kong compiled by the authors. This data is especially important as the amount of information known about the dynamic parameters of buildings of these heights is limited. Effects of the variation of the natural period and damping values on the alongwind response of a tall building for serviceability-level wind conditions have been profiled using the gust response factor approach. When using this approach on these two buildings, the often overestimated natural periods and structural damping values suggested by empirical predictors tended to offset each other. Gust response factors calculated using the natural periods and structural damping values measured in the field were smaller than if calculated using design-stage values.

A Study on the Size Computation of Seogwipo Cruise Terminal CIQ Facilities (서귀포 크루즈터미널 CIQ시설 규모산정에 관한 연구)

  • Park, Chung-Keun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.3
    • /
    • pp.27-36
    • /
    • 2015
  • This research studies the adequate size standard of Seogwipo cruise terminal CIQ facility that is scheduled to be built around Gangjeong harbor area in Seogwipo-city. In order to respond to the highly increasing number of passenger cruise ships compared to Seogwipo cruise terminal design in 2010, the adequate size standard of Seogwipo cruise terminal CIQ facility was examined for passenger service level grade. Based on size computation elements such as the number of passengers of cruise ships with the largest size of port entry, ship landing rate, passenger processing ratio, and surge factor, the CIQ facility size for each service level grade was reviewed. As a result, the area of 2,971m2 (A grade), 2,409 m2 (B grade), and 2,088 m2 (C grade) were computed. This showed that the area of B grade was about 82% and C grade 70% compared to the area of A grade. The CIQ facility size computed for each service level grade in this research was analyzed that its area needed to be increased by 322% at least and 458% at most, compared to the CIQ facility area of 649m2 of the existing design (2010). In order to respond to the increasing number of cruise passengers, provide high-level passenger service, and improve the international image of Jeju, Seogwipo cruise terminal should secure the size that is equal to or higher than the B grade of service level.

Fundamental design consideration for optimum performance in altitude test cell facility (고공시험설비의 전체 사양을 결정하는 시험부를 중심으로 설비개발시의 주요 고려사항)

  • Choi, Kyoung-Ho;Lee, Jung-Hyung;Owino, George;Lee, Dae-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.411-415
    • /
    • 2008
  • This paper presents on design factor considered in an altitude test cell facility to determine the best sizing to optimize exhaust diffuser pressure recovery and the exact cooling load required to be supplied under transient operation. Engine simulation was performed to analyse the exhaust gas temperature, exit mass flow rate, specific fuel consumption and exhaust velocity helpful in determining secondary mass air flow and the mixed air temperature entering the ejector. based on this, the amount of cooling load was deduced. It was found that improved pressure recovery reduces operational cost(air supply facility, cooling water).

  • PDF

Environmental Design Factors for Open Space in Healing Facilities - Focused on Ann & Robert H. Lurie Children's Hospital and The Nationwide Children's Hospital -

  • Kim, Sunyoung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2021
  • The open space of the healing facility should contribute to the psychological and social healing of the users, provide a social environment for rest, and provide a design factor to support the walking path to move to the destination-connected space. In this paper, I examined the relationship between the environmental elements, spatial devices, and the characteristics of the design factors in the open space for healing facilities. As a research method, based on the analysis of previous studies, a healing facility in modern society was defined, and the relationship between the social support and physical environment factors of the healing facility where open space was considered. Through the consideration of cases, the characteristics of the physical space environment, and the design factors of the open space in the healing facility were categorized. As a result of research, open space in the healing facility is a space to promote a social exchange of users, as a physical form for accommodating psychological and social healing functions, it is necessary to construct the connection of the external space with the internal space.

A Study on Social Carrying Capacity in Outdoor Recreation Setting: An Exploratory Analysis on the Perceived Crowding Path Model in National Park (옥외휴양공간에서의 사회적 수용능력연구: 국립공원에서의 혼잡지각의 경로모형 분석)

  • Park, Chung In
    • KIEAE Journal
    • /
    • v.5 no.1
    • /
    • pp.35-42
    • /
    • 2005
  • The primary concerns of recreation plan are to provide visitors with quality of recreational experience and to protect of recreation resources. The quality of recreational experience is often defined in terms of social carrying capacity. The carrying capacity is revealed as perceived crowding. In this respects, measuring perceived crowding is useful tool of social carrying capacity determination. This study is to test the structural equation model that includes variables affecting perceived crowding. Through an on-site questionnaire survey, 467 visitors on Naejangsan national park were collected. The results of the study are follows. The encounter level on facility area is higher evaluated as crowding factor than other area in the park. It can be concluded that visitor perceived crowding when facility area situates high density use level rather than other areas expose high density use level. In the path analysis, the input variables(attitude, experience, encounter level) on the structural equation model affect significantly on perceived crowding. Especially, the attitude on the park management polocy is the most affecting factor on perceived crowding.

A Research the Optimal Plant Life Cycle using Case Study (사례를 통한 최적 라이프 사이클에 관한 연구)

  • 심종칠;김창은;고용해
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.18 no.34
    • /
    • pp.83-89
    • /
    • 1995
  • We call as plant life cycle the process starting from plant plan, design to disuse by way of construction, operation, but the plant facility inside it comes to changes of cope with various inner factor like blazing phenomenon and outer factor according to economic state. On the presumption of these factors, the problem is brought about how plant should be managed, this study attempt to suggest the conservation management through economic evaluation in investment design and alternative, that is, methodology connecting that of economical efficiency evaluation based on LCC(Life Cycle Costing) thinking method and facility management with that of life prediction.

  • PDF

A Study on the Design Standard of Substation Facility Density and Demand Factor in Office Buildings (사무소용건물의 변전시설밀도 및 수용률 기준설정에 관한 연구)

  • 김세동;정동효
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.6
    • /
    • pp.42-48
    • /
    • 1992
  • This paper shows a reasonable design standard of substation facility density and demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, electric power consumption, etc for 121 buildings. The saving of electric equipment investment, the decrease of power loss, the improvement of facilities utilization and the decrease of electric power rates an be contributed by the application of the design standard must be applied by the revision of current regulations and laws.

  • PDF

A Study on the Quantitative Evaluation of Outdoor-Recreational Function and User Satisfaction with Urban Park and Open Space (도시공원녹지에 대한 실외위락기능과 만족도의 계량적 평가에 관한 연구)

  • 박승범
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.18 no.4
    • /
    • pp.127-140
    • /
    • 1991
  • The Primary purpose of this study is to investigate factors and variables which have significant effects on user satisfaction with recreational facilities in Taejong-Dae recreational complex, thereby establishing indices of planning and development of urban parks and open space. To test the causal models of this research, the date were gathered by self-administered questionnaires from 967 households in Pusan City which were selected by the multi-stage probability sampling methood. The analysis of the multi-stage primarily consists of two phase : The first analysis dealt exploratory factor analysis which identified major factors involved in satisfaction with recreational activities and facilities in Taejong-Dae recreational complex and the second analysis tested the fit of the causal models of this research by employing LISREL methodology. There are three advantages of using LISREL over other multivariate analysis methods : First, measurement error is allowed and calculated in LISREL, otherwise there is a risk of seriously misleading estimates of coefficients ; Second, LISREL deals with latent variables or unmeasured variables ; Third, it enables to test causal relations among variables. The factors analysis identified that five factors are involved in satisfaction with recreational facilities. The five factors of satisfaction with recreational facilities are space for repose and relaxation, active recreation facilities such as pool and zoo, physical exercise facility, convenience and maintenance facility, and linear facility, and linear facility for walking. The second phase analysis tested the fit of the causal models for satisfaction with recreational facilities to the data and identified statistically significant causal linkage among overall satisfaction with Taejong-Dae recreational complex, other endogenous factors and exogenous variables. Overall fits of both causal models were very good. Among endogenous factors, facility for repose and relaxation. linear facility for walking, active recreation facility, facility for convenience and maintenance were identified as having significant effects on overall satisfaction. Exogenous variables which have significant effects on endogenous variables wer also identified. These significant relationships indicate important factors and variables that should be considered in planning and development of the recreational complex. On the basis of these significant causal relationships, implications for planning and the delovepment of Taejong-Dae recreational complex were suggested.

  • PDF