• 제목/요약/키워드: Facility Noise

검색결과 247건 처리시간 0.028초

UHFPD측정시스템을 이용한 GISPD측정 (GISPD Measurement Using UHFPD Measurement System)

  • 최재구;이상화;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1857-1859
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the noise suppression methods and the PD measurement results of the in-service substation by the developed UHF PD measurement system which consists of the external UHF coupler, the UWB LNA and the digital storage oscilloscope. As results, it was found that the effect of the noise suppression methods were verified and that the developed external UHF coupler showed a better detection sensitivity than a conventional external coupler.

  • PDF

천장속 공간을 공유하는 매단 천장의 실간 공기전달음 차단성능 측정방법의 KS규격화 방안 (Korean Standard Draft of the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling)

  • 양관섭;이근희;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.956-960
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO and ASTM have been used for evaluating sound performance in domestic so fu. In this study, Korean Standards draft on test methods and test facility of suspended ceiling system and materials is proposed on the basis of ISO and ASTM.

  • PDF

38M6 리사이클 Compressor의 고속진동 밸런싱 사례연구 (A Study of High-speed Vacuum Balancing for 38M6 Recycle Compressor)

  • 이동환;김병옥;이안성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.657-662
    • /
    • 2004
  • This paper presented is a case study of a real compressor rotor of a refinery plant for high speed balancing of flexible rotor. The rotor was tested in the expert high-speed balancing facility established by KIMM at early 2004. The capability of the facility can reach 40000rpm in rotation speed and 8 ton in rotor weight for high-speed balancing. The facility performs multi-plane at-speed balancing using influence coefficient from the vibration data measured at two pedestals. The test rotor had exceeded permissible criteria of vibration at initial run. But by processing a low-speed balancing at 1000 rpm and six trial run trying to calculate influence coefficient of rotor to the range of operating speed, the final result of high-speed balancing revealed a remarkable reduce of vibration at pedestal of the rotor.

  • PDF

매단 천장의 실간 공기전달음 실험실 측정 방법 고찰 (Investigation on the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling)

  • 양관섭;이근희;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1126-1131
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO or ASTM have been used for evaluating sound performance in domestic so far. In this study, every regulation from ISO, ASTM, especially for airborne sound insulation against suspended ceiling system, is analyzed in order to apply to establishment of Korean Standards on test methods and test facility of suspended ceiling system and materials.

  • PDF

KSR-III Rocket 종합 추진 시험 설비에서 발생한 열-음향학적 진동의 특성 (The characteristics of thermo-acoustic oscillation happened at PTA-II of KSR-III rocket)

  • S. Cho;S. Kang;Kim, Y.;I. Cho;S. Oh;Lee, D.
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.364.2-364
    • /
    • 2002
  • Thermoacoustic oscillation, which stems from phase correlation between unsteady heat release and acoustic fluctuation, can cause severe vibration and incite the excessive local heat transfer inside the rocket engine. It is very important to understand and prevent this phenomenon in the way of rocket engine development. In this study, the propulsion test facility of KSR-III, which is the first liquid propellant rocket developed by KARI, will be introduced. and the characteristics of thermoacoustic ocillation occurred at the facility will be examined.

  • PDF

소음과 경관을 고려한 주택단지계획의 수립에 관한 연구 (Study on Residential Section Plan Considering Traffic Noise and Scenery)

  • 선효성;박영민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.693-695
    • /
    • 2007
  • This study describes the proposed methods for constructing the residential section which satisfies quiet environment and scenery at the same time. For the purpose of achieving this objective, the influences of house arrangement, house skyline change, soundproofing facility installation, etc. on traffic noise environment and scenery are compared using document investigation and computational results.

  • PDF

상수도관로 누수신호의 특성 분석을 위한 누수 실험시설 개발 (Development of leakage test facility for leak signal characteristic analysis in water pipeline)

  • 박상혁;곽필재;이현동;최창호
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.459-469
    • /
    • 2017
  • A real scale leakage test facility was developed to study the leak signal characteristics of water supply pipelines, and then leak tests were carried out. The facility was designed to overcome the limited experimental circumstances of domestic water supply pipeline experimental facilities. The length of the pipeline, which was installed as a straight line, is 280m. Six pipes were installed on a 70m interval with different pipe material and diameters that are DCIP(D200, D150, D100, D80), PE(D75) and PVC(D75).The intensity of the leakage is adjusted by changing the size of the leak hole and the opening rate of ball valve. Various pressure conditions were simulated using a pressure reducing valve.To minimize external noise sources which, deteriorate the quality of measured leak signal, the facility was built at a quiet area, where traffic and water consumption by customers is relatively rare. In addition, the usage of electric equipment was minimized to block out noise and the facility was operated using manual mode. From the experimental results of measured leakage signal at the facility, it was found that the signal intensity weakened and the signal of high frequency band attenuated as the distance from the water leakage point increased.

고에너지 음향환경시험 튜브 개발 (Development of High Intensity Progressive Wave Tube)

  • 김영기;김홍배;문상무;우성현;임종민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.962-965
    • /
    • 2005
  • A high intensity progressive wave tube is installed at Korea Aerospace Research Institute (KARI) for acoustic environmental tests. The test facility has 700 mm x 800 mm cross-sectional area, and provides acoustic environment of 165 dB over the frequency range of $25Hz{\sim}10,000Hz$. The facility consists of a 6 m long acoustic wave tube, acoustic power generation systems, gases nitrogen supply systems, and acoustic control systems. This paper describes how the basic parameters of the facility and power generation systems are controlled to meet the requirement of the test. The shape and length of the tube has been designed by using the size of test objects and the wave propagation characteristics of the tube. The capacity of acoustic power generation systems is determined by the energy conversion of acoustic wave and the efficiency of acoustic modulators. Moreover, the paper introduces test run results of the tube. Overall of 163dB has been generated by using the test facility.

  • PDF

설정 음압 및 스펙트럼 재현을 위한 음향 환경 시험 챔버의 기본 설계 변수 선정 (Design of High Intensity Acoustic Test Facility to Generate Required Sound Pressure Level and Spectrum)

  • 김영기;우성현;김홍배;문상무;이상설
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.867-872
    • /
    • 2002
  • A high intensity acoustic test facility is constructed at Korea Aerospace Research Institute (KARI) by 2003. The reverberant chamber of the facility has a volume of 1,228 cubic meters and shall provide an acoustic environment of 152 dB over the frequency range of 25 Hz to 10,000 Hz. The facility consists of a large scaled reverberant chamber, acoustic power generation systems, gases nitrogen supply systems, and acoustic control systems. This paper describes how the basic parameters of a chamber and power generation systems are controlled to meet the requirement of the test. The volume of a reverberant chamber is controlled by the size of test objects and the reverberant characteristics of a chamber. The capacity of acoustic power generation systems is determined by the energy absorption of a chamber and the efficiency of acoustic modulators. Simple math is employed to calculate the required power of acoustic modulators. Moreover, the paper explains how the distribution of sound pressure level at low frequency is checked by analytical and numerical methods.

  • PDF