Investigation of Exhaust Facility of Liquid Rocket Propulsion System (액체로켓 추진기관의 후류처리장치 고찰)

  • Cho, Nam-Kyung;Lee, Kwang-Jin;Han, Young-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.133-138
    • /
    • 2012
  • Exhaust facility has basically the role of flame deflector, and considering additional functions, it can be classified by noise/emission suppressor and altitude simulation facility. In this paper, principles of flame deflector, jet pump, emission suppression are presented for exhaust treatment facility. Principles of noise suppression caused by Mach wave mitigation, jet energy mitigation by water evaporation and condensation are shown. In addition, a concept of vertical exhaust treatment facility is presented applying basic principles aforementioned.

  • PDF

Modification of Dia. 2m-Small-scaled Rotor Test Facility (직경 2m급 축소로터 시험장치 개조 및 보완)

  • Song, Keun Woong;Lee, Jae Ha;Kim, Seoung Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.190-195
    • /
    • 2012
  • Small-scaled Rotor Test facility(GSRTS, General Small-scaled Rotor Test Facility) in KARI could not use the test because facility aging and parts discontinued. Also in order to perform a joint international research, GSRTS modifications should be needed. So requirements of GSRTS modifications were established and according to the requirements, GSRTS modifications were conducted. Facility operation test, 6-component fixed balance calibration, Small-scaled OLS rotor performance test were performed to verify the results of GSRTS modifications. Reasonable results were obtained in comparison to calculation results. Then GSRTS ready was completed to conduct international collaborative research and wind tunnel test.

  • PDF

Aircraft Engine Performance Test Technologies by 150K lbf Thrust Test Cell (15만 파운드급 테스트 셀을 이용한 엔진성능 시험기술)

  • Kim, Woocheol;Kim, Chul;Kim, Sangbaek
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.180-187
    • /
    • 2017
  • Major design targets such as test cell type, cell flow, cell bypass ratio, approach velocity, cell depression, front cell distortion, noise level and vibration level to construct a new 150,000 lbf thrust aircraft engine test facility were established. Based on the final aerodynamic and acoustic performance tests conducted at the newly constructed test facility, it was found that the new test facility is judged to be excellent and meets design targets.

  • PDF

Traffic Noise Reduction of Sunken Squares (썬큰광장의 교통소음 감쇠 효과)

  • Min Jang-Ki;Chang Tai-Hyun;Jung Jae-Man
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.5
    • /
    • pp.35-42
    • /
    • 2004
  • This study examines the traffic noise reduction effects of the diverse efficiency features of a sunken square, and investigates the reduction effects and characteristics of noise alterations according to the construction conditions in order to verify its possibility as a new noise reduction facility. The measured data were analyzed. As a result, (1) the traffic noise from the roads around the sunken squares exceeded the regulatory standards; (2) the sunken squares were protected from noise; (3) the sunken spaces yielded a greater reduction by 6∼7dB than the flat ground thanks to the diffraction effect; and (4) there were fine changes to noise according to the conditions of space construction. In short, a sunken square has the potential to afford new applications as a noise reduction facility in a highly concentrated downtown with the existing defects solved. In addition, its use for effective noise control is evident based on the noise characteristics of a space. Future studies need to include efforts to provide clearer quantitative data, as well as research on shape, layout, and materials.

Korean Standard Draft of the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling (매단 천장의 실간 공기전달음 차단성능 측정방법의 KS규격화 방안)

  • Yang, Kwan-seop;Lee, Keun-hee;Kim, Sun-woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.393.1-393
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO and ASTM have been used for evaluating sound performance in domestic so far. In this study, Korean Standards draft on test methods and test facility of suspended ceiling system and materials is proposed on the basis of ISO and ASTM.

  • PDF

Development of Reducer for Generating Facility of Electric Power for Low Noise/vibration (소음/진동을 고려한 발전설비용 감속기 개발)

  • Lee, Hyoung-Woo;Park, Chul-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.11
    • /
    • pp.73-82
    • /
    • 2008
  • A dynamic model of reducer for generating facility of electric pourer having bevel gear pair and planetary gear train is developed by lumped method. The model accounts for the shaft and bearing flexibilities, gyroscopic effects and the force couplings among the transverse and torsion motions due to gearing. Vibration/noise analysis as well as strength of bevel gear pair and planetary gear train are considered. Exciting forces of high reducer for generating facility of electric power areconsidered as the mass unbalance of the rotors, misalignment and a function of gear transmission error. A Campbell diagram, in which the excitation sources caused by the mass unbalance of the rotors, misalignment and the transmitted errors of the gearing are considered, shows that, at the operating speed, there are not critical speed.

Experimental study of reverberation time in ship's public area (선박의 공용구역 잔향시간의 실험적 연구)

  • Kim, Taemoo;Choi, Choongyoung;Park, Nojun;Park, JeanHyung;Kwun, Hyuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.242-242
    • /
    • 2013
  • Recently, importance of working environment is increased in commercial vessel and offshore structure. Marine facility design and ambient environment condition are influenced to enhancing human performance and reducing human errors. Consequently, the quality of accommodation where offshore facility crews sleep, eat and relax will influence their job performance and overall sense of comport and well-being. Therefore, adequate acoustic isolation between adjacent spaces is normally required to achieve satisfactory internal noise levels, acoustic privacy and speech intelligibility. In this study, the reverberation time is investigated in the public areas where there are not provided the information of material's noise reduction coefficient (NRC). The experiment of reverberation time is rarely performed for the various type public areas in a marine structure. Therefore, the reverberation time in a vessel is investigate in order to evaluate the room's noise reduction coefficient (NRC) in a public area.

  • PDF

A method to reject noise signals in partial discharge signals of turbine generator (터빈 발전기의 부분방전 신호 중 노이즈 제거 방법)

  • Park, Y.H.;Park, P.G.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.240-242
    • /
    • 2005
  • It is well known that the PD (Partial Discharge) signals are generated if insulators have some defects such as voids in electrical facility and various PD detection methods are developed for preventing electrical troubles. So, an interest for the PD signals is higher and higher according to the high concern for the defects detection method of the aging electrical facility. When the equipment to detect PD signals installed at site and it works, a lot of noises flow in the equipment from surrounding situation and it will be mixed with original PD waveform. So we can not get the desired PD waveform. Therefore, there are many trial to reject or suppress the noise from the PD signals from long times ago. The greater of them used the hardware such as bridge circuits and frequency filters to suppress the noise. This paper proposed a novel noise rejection method in acquired data from PD detection equipment. The noise has the irregular phase and higher signal level than real PD, and noise decision is performed after inspection of pulse distribution in ${\Phi}$-q-n graph of acquired data from PD detection equipments. By experimental results on high voltage electric equipments, it is shown that proposed method has good performance. It is expected that this noise rejection technology is useful in numeric calculation and trend management of PD level.

  • PDF

An Experimental Study on Ducted Silencers I (ISO 7235) (덕트 소음기의 실험적 연구 I (ISO 7235))

  • 남경훈;박희주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.282-287
    • /
    • 2001
  • The test facility has been manufactured to predict the dynamic insertion loss and the pressure drop for ducted silencers based on ISO 7235. The qualification test of the test facility is necessary for determining the dynamic insertion loss and the pressure drop of the test silencer, and is surveyed the reflection coefficient for an anechoic termination, the velocity profile near the upstream connection to the test silencer, the reduction of the system silencer and the limiting insertion loss due to the flanking sound transmission along the duct walls.

  • PDF

Development of noise mapping system to manage the interior room noise of power plants (발전소의 실내 소음관리를 위한 소음 매핑 시스템 개발)

  • Kim, Young-Il;Kim, Won-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.92-98
    • /
    • 2021
  • The noise management in the interior of the power plant is difficult because the interior is large and the noise level varies greatly from location to location. Therefore, a noise visualization system capable of analyzing the noise distribution is required in order to effectively manage the interior noise. A noise mapping system was developed that can model the inside of the turbine room and create a noise map by measuring the noise level at selected points. And in order to increase the reliability of the model, the model was modified through a method of comparing the noise map and the actual noise measurement results. Facility abnormalities can be determined through regular analysis of noise maps, and a method of effectively managing the interior noise is presented by comparing and analyzing the frequencies and levels of the current and previous noise at a specific point. By using the mapping system, it is possible to establish noise countermeasures that can improve the working environment, check the machine for abnormalities, and increase the reliability of the facility through preventive maintenance.