• Title/Summary/Keyword: Facility Criteria

Search Result 519, Processing Time 0.034 seconds

An Analysis of Relation between Supply Criteria of Public Facilities and Residents' Satisfaction for the Community Revitalization in the Apartments (공동주택 내 커뮤니티 활성화를 위한 주민공동시설 설치기준과 주민 만족도와의 관계 분석)

  • Choi, Ki-Taek;Lee, Joo-Hyung
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.19-28
    • /
    • 2011
  • This study examines the current status on the supply of community facilities based on the supply criteria of present welfare facilities. Analyzing satisfaction of residents about community facilities based on physical supply criteria. The study sets up the concept and proposed trend of the related studies and distinction through the examination of previous researches. Next, the present systematical supply criteria, was used to make indication in order to propose the promotion of improvement on supply criteria for community facilities. Multi dimensional analyzing system and the satisfaction level of the community facility was used to analyze the relationship between the two. The direction of policy improvement according to the analysis is as per the following. First, it is necessary to improve supply criteria of household to guarantee the minimal amount of space. Second, specification of the minimum distance of community facility to residential area in the complex is needed. Also, the presentation of bottom boundary line of the formation area size to expand the size up to minimal level of size is needed. Third, resident exercise facility supply criteria among the community facility supply criteria need to be improved from the number of household base to the size for each household base. Forth, resident resting facility criteria among the community facility supply criteria should be changed from the present criteria of one facility per five hundred households.

A Study on the Consumer Choice Criteria based on Facility Purpsoe for Multi-Mixed Complex Medical Care Facility Development (의료복합시설 개발을 위한 시설용도별 이용자 선택기준에 관한 연구)

  • Sung, Nayoung;Lee, Sangyoub
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.4
    • /
    • pp.28-39
    • /
    • 2016
  • The multi-mixed complex medical care facility consisting of mainly hospital and other associated facilities such as retail, office, accommodation, healthcare services, and so on, is currently recognized as a new segment in the real estate market. This study intends to identify the customer choice criteria for the development of multi-mixed complex medical care facility. Based on literature review and expert consultation, the 3 criteria with 12 sub-criteria for customer choice have been defined. And the AHP methodology has been implemented for the development of relative weight of those criteria depending on the type of facility including 'medical facility', 'supporting facility', 'healthcare service facility' and 'other ancillary facility'. Research findings indicated the implication for the optimal combination of facility development based on the customer choice criteria controlled by facility. Accordingly, this research intends to provide the guidance toward the development of multi-mixed complex medical care facility.

Layout Criteria of an Access Mode's on and off Facility at Multiple Transfer Centers (복합환승센터 접근교통수단의 승하차 시설배치기준)

  • Kim, Si-Gon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2D
    • /
    • pp.95-101
    • /
    • 2012
  • Layout Criteria are developed for an access mode's on and off facility at multiple transfer centers in this paper. Layout Criteria are location issues between a main mode and access modes in terms of the on and off facility one another. The total distance between them has been suggested to be minimized. In the distance calculation stairs are considered to be more difficult and than open space. On the other hand an escalator and an elevator are treated as easier than open space. Considering the number of people between on and off facility, the weighted average distance is suggested to be a MOE(Measure of effectiveness) for layout criteria at multiple transfer centers. Finally, the layout criteria are applied to the existing Kimpo airport terminal and some improvement ideas are suggested.

A Study on the Planning Criteria for Thalassotherapy Facility (해양치유시설 계획기준에 관한 연구)

  • Lee, Han-Seok;Kang, Young-Hun;Seong, Hai-Min
    • Journal of Navigation and Port Research
    • /
    • v.44 no.1
    • /
    • pp.20-31
    • /
    • 2020
  • The purpose of this study was to provide planning criteria for the thalassotherapy facility. Among the various contents of the planning criteria, the crucial parts of the thalassotherapy facility planning are the location, facility environment, and room space. To do this, we first examined the characteristics of the thalassotherapy facility and inquired about the thalassotherapy resources and treatments that are the basis of the thalassotherapy facility planning. And then, the overseas qualification criteria related to thalassotherapy facility were analyzed. Based on the above research results, the criteria for the thalassotherapy facility planning on location, facility environment, and spaces of rooms are presented. The location is within 1km of the coastline, where there is no pollutant emission facility, and the climate conditions are maintained more than 80% throughout the year below 'caution' level of the thermal sensation index and sensory temperature. The water quality of the facility environment meets the stricter criteria among the domestic standards or ISO 17680 standards, and the air quality is 60% of the atmospheric environment standard of the 「Framework Act on Environmental Policy」 and SO2, NO2, O3 and PM10 concentration shall ensure that the annual number of exceeding standards meets the EU standard, and noise is less than 50dB per daytime, 40dB per night. Therapy spaces have to meet the standards of the 「Building Act」, the working standards of architectural planning and international standards according to their function and use.

An Integrated AHP-VIKOR Methodology for Facility Layout Design

  • Shokri, Hamidreza;Ashjari, Behzad;Saberi, Morteza;Yoon, Jin Hee
    • Industrial Engineering and Management Systems
    • /
    • v.12 no.4
    • /
    • pp.389-405
    • /
    • 2013
  • A facility layout design (FLD) problem can be generally introduced as assignment of facilities (departments) to a site such that a set of criteria are satisfied or some objectives are minimized (maximized). Hence, it can be considered as a multi-criteria problem due to the presence of qualitative criteria such as maintenance or flexibility and quantitative criteria such as the total cost of handling material. The VIKOR method was developed to solve multiple criteria decision making problems with conflicting and non-commensurable (different units) criteria, assuming that compromising is acceptable for conflict resolution, the decision maker wants a solution that is the closest to the ideal, and the alternatives are evaluated according to all established criteria. This paper proposes a hierarchical analytic hierarchy process (AHP) and VIKOR approach to solve the FLD problem. A computer-aided layout-planning tool is adopted to generate the facility layout problems, as well as their quantitative data. The qualitative performance measures are weighted by AHP. VIKOR is then used to solve the FLD problem. Finally, the proposed integrated procedure is applied to three real-time examples.

Development of classification criteria for non-reactor nuclear facilities in Korea

  • Dong-Jin Kim;Byung-Sik Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.792-799
    • /
    • 2023
  • Non-reactor nuclear facilities are increasing remarkably in Korea combined with advanced technologies such as life and space engineering, and the diversification of the nuclear industry. However, the absence of a basic classification guideline related to the design of non-reactor nuclear facilities has created confusion whenever related projects are carried out. In this paper, related domestic and international technical guidelines are reviewed to present the classification criteria of non-reactor nuclear facilities in Korea. Based on these criteria, the classification of structures, systems and components (SSCs) for safety controls is presented. Using the presented classification criteria, classification of a hot cell facility, a representative non-reactor nuclear facility, was performed. As a result of the classification, the hot cell facility is classified as the hazard category 3, accordingly, the safety class was classified as non-nuclear safety, the seismic category as non-seismic (RW-IIb), and the quality class as manufacturers' standards (S).

A Study on the Architectural facility standards of integrated child care facility (통합보육시설의 시설 및 설비 기준에 관한 연구)

  • Kim Young-Eun;Park Hyeon-Soo;Lee Keon-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.3 s.56
    • /
    • pp.136-143
    • /
    • 2006
  • This research proposes the importance of physical environment if integrated early childhood education. For a successful integration of children's education, we processed fundamental research on requirements of facility and equipments, looking at related standards and code on handicapped person's convenience facility. Also, this research alms at providing first step to establish evaluation method and quality assurance standards of integrated child care facility, regarding space planning of handicapped children. By examining home and abroad material and analyzing handicapped children's convenience facility standards, this research pursues improving the basis of planning criteria. As present criteria of relevant regulations appears not to handle detailed facility standards, and the handicapped people's facility is for childhood education, it is necessary first to differentiate indispensable equipments from optional one, then categorize them into more specific needs.

A Study on the Facility Eligibility Inspection of National Inpatient Isolation Units (국가지정 입원치료 격리병상 시설적격성 평가분석에 관한 연구)

  • Hong, Jin Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.506-514
    • /
    • 2015
  • During the progression of this study, we visited 17 medical institutions. These medical institutions underwent inspection for facility eligibility of national inpatient isolation units to care for patients. Seventeen consultation meetings were held to gather expert opinions, and conferences were held with the medical institutions and local levels of government. Based on these facts, we established a field application model of the criteria of safety-management and conducted a study on this method in order to create more scientific and systematic safety-management criteria including criteria regarding facilities maintenance and methods of equipment inspection. According to an analysis on the 17 medical institutions examined, facility eligibility of 17 national inpatient isolation units was found to be 78.3% on average. Through analysis of the present domestic and foreign conditions of medical institutions, we proposed improvements for when remodeling becomes necessary and established criteria for safety-management in national inpatient isolation units for the care of patients in accordance with the domestic healthcare system.

Design Criteria in Barrier Free Housing (장애물 없는 주택 설계기준에 관한 연구 - 국내 공동주택의 무장애(barrier free) 설계수준 평가를 중심으로 -)

  • Kim, Sang-Woon;Park, Kwani-Jae;Kang, Byoung-Keun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.10 no.2
    • /
    • pp.107-115
    • /
    • 2004
  • In this paper, the all units of residential housing that is not legislated in facility development law are analyzed and foreign design criteria that is related to barrier-free unit housing is comparing to domestic. Through the comparison in front door, living room, bathroom, bedroom, and kitchen, this paper aims to suggest internal barrier-free design criteria. This paper is limited to internal housing which are front door, living room, bedroom, bathroom, and kitchen. Also, the objectives of facility development law are U.S, Japan, German, and in case of U.S, UFAS is established by ADA, in Japan, Heart Building law and detail standard drawing are used, in German, DIN is used. The objective of domestic case study is the latest residential housings that are built over 2003. The flow of study is as follows ; First, the internal items of residential housing are abstracted, and each item is checked in facility development law that is legislated in. Next, through comparison of domestic and foreign facility development law related to housing, common items are abstracted and detail standards are defined. Domestic residential housings are analyzed in those standards. Finally, the problems that is the result of analysis are analyzed and the barrier free design criteria is abstracted in unit housing. Also, more developed items and future study are suggested.

  • PDF

Land Suitability Analysis of Collective Facility Area in the Kimhae Daechung Park using Geographic Information System and Multi-Criteria Evaluation (GIS와 다요소의사결정방법(MCE)에 의한 김해 대청공원 집단시설지구 적지분석)

  • Hwang, Kook-Woong;Lee, Kyu-Wan
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.3 no.3
    • /
    • pp.45-53
    • /
    • 2000
  • Geographical Information Systems(GIS) overlay analyses, while ideal for performing spatial searches on nominally mapped criteria, are of limited use when multiple uncertian criteria are concerned. But, Multi-Criteria Evaluation(MCE) techniques offer a means of making complex siting decisions, involving multiple criteria. The integration of GIS and MCE techniques became rational and objective approach to perform land suitability analysis on the basis of multiple criteria. An example application based on the search for suitable sites for the collective facility area in the kimhae daechung park using IDRISI is described.

  • PDF