• Title/Summary/Keyword: Facility Condition

Search Result 951, Processing Time 0.022 seconds

Research on a Valuation Standard and the Actual Condition About Security Management in PACS (PACS에서 보안관리 평가기준 연구와 실태조사)

  • Jeong, Jae-Ho;Dong, Kyung-Rae;Kweon, Dae-Cheol;Son, Gi-Gyeong;Kim, Hyun-Soo;Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.347-353
    • /
    • 2008
  • This study is to prepare an evaluation standard about personal information protection and security management of a medical institution and to build up a grade standard of evaluation in PACS environment. We built up evaluation index based on 10 detailed items in four big categories (political security, technical security, data management security and physical security) by referring to ISO17799 (BS 7799), HIPPA (Health Insurance and Portability and Accountability Act of 1996) and domestic medical law. We have investigated at the thirty places where medical facility with the extracted security criteria and security evaluation index. Average score of physical security list, one of the big categories, was 18.5/20 (93%) at all medical institutions. Political security score was 18.5/30 (62%), data management security score was 12/20 (60%) and technical security score was 17.5/30 (58%). Therefore, security evaluation score was average 67 in 30 general hospitals, which was 4th level. The results showed that it is necessary to establish evaluation and management standard about personal information protection and security consciousness which are weak in PACS environment.

  • PDF

A Study on the Utilization Level of Public Facilities Obtained through Contributed Acceptance on Urban Regeneration Planning (도시정비사업의 기부채납 공공시설 이용실태에 따른 개선방안 연구)

  • Min, Bi Ra;Yin, Myung No;Yoo, Shin Ho;Kang, Jun Mo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4D
    • /
    • pp.397-406
    • /
    • 2012
  • Contributed acceptance system is causing problems with the usefulness and follow-up services and the like, other than the origin purpose which needs to be operated as rational adjustment method between the public interest and the private. Accordingly, this study has examine the problems by analyzing the present condition of practical public facilities and has the purpose on drawing the improvements by conducting consciousness survey from in substance users. The problems drawn from the analysis and the survey are location and position of the public facilities by reason of making public facilities at leftover land, the awareness and use as in-site facilities, creating street facilities without considering the use and safety of the users, follow-up service issues and the usefulness issues by creation without considering the surrounding conditions. The proposal of improvements for efficient operation by each problems are devising plans by considering location and position of the facilities for utilization and usefulness, secondly the necessity of the public relations for the improvements of the utilization of public facilities. thirdly, conducting the legal obligation by installing direction boards for its awareness of public facilities and delegating operation of facilities to public corporations such as SH, LH and inhabitants for efficient follow-up services, lastly, establishing the public facility map service which could figure out the surrounding conditions of public facilities to utilize for the contributed acceptance.

Characteristics of Thermophilic Methane Fermentation Using the Organic Wastes (유기성 폐기물을 이용한 고온 메탄 발효의 특성)

  • Kim, Nam-Cheon;Choi, Suk Soon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.2
    • /
    • pp.29-37
    • /
    • 2008
  • In this work, it was investigated that various aspects of process, application situation, merits and short-coming results of the thermophilic methane fermentation with highly concentrated organic waste substances such as sewage sludges, food wastes and excretions. The merits of this methane fermentation were that it had a very fast reaction rate and was possible to proceed in high loads. It was also high in mortality for pathogenic microorganism and the digested sludge was more hygienic. However, the short-comings were that more energy was required for heating in the fermentation facility, no surplus energy could be gained from low concentration of organic waste, the fermentation treatment dropped level of water quality, thus burdens discharging process of water. Especially, the high concentration of methane fermentation could possibly lack nutritious salt and could face the disturbance by ${NH_4}^+-N$, a proper alternative was required. In general, thermophilic methane fermentation was considered as a better mean in disposing of cow excretion and food waste which were highly concentrated organic wastes. On the other hand, under the condition where the concentration of waste material was low and the high concentrate waste material became higher than 3,000 mg/L in ${NH_4}^+-N$, thermophilic methane fermentation resulted less desirable outcome.

  • PDF

Performance Improvement of an Air Source Heat Pump by Storage of Surplus Solar Energy in Greenhouse (온실 내 잉여 태양열을 이용한 공기열원 히트펌프 성능향상)

  • Kwon, Jin Kyung;Kang, Geum Chun;Moon, Jong Pil;Kang, Youn Ku;Kim, Chung Kil;Lee, Su Jang
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.328-334
    • /
    • 2013
  • A greenhouse heating system to improve heat pump performance using inside and outside air of greenhouse as a heat source selectively and cut $CO_2$ enrichment costs by delay of greenhouse ventilation was developed. In this system, thermal storage modes divided into inside circulation mode using surplus solar energy and outside circulation mode using outside air heat. The thermal storage modes were designed to be switched mutually according to inside greenhouse temperature and six temperature values were input to control the heat pump operating, thermal storage mode switching and greenhouse heating automatically. Operating characteristics of this system were tested in a plastic greenhouse of non-ventilation condition. The results of test showed that the inside circulation mode began at about 11:00 and lasted for about 210 minutes and inside greenhouse temperature was maintained between $20{\sim}28^{\circ}C$ in spite of non-ventilation. System heating COP of the inside circulation mode in the daytime was 3.35, which was 36% and 25% higher than that of the outside circulation modes in the nighttime and daytime respectively.

Effect of Professional Oral Healthcare Program on the Oral Status of Elderly Residents in Long-Term Care Facilities (전문가 구강위생관리가 장기요양시설 재원노인의 구강상태에 미치는 효과)

  • Lee, Keun-Yoo;Lim, Soon-Ryun
    • Journal of dental hygiene science
    • /
    • v.16 no.6
    • /
    • pp.432-441
    • /
    • 2016
  • This study was conducted to investigate the effects of professional oral healthcare program in eldery residents long-term care facilities. Ninety-four elderly residents from 5 different facilities in Asan participated in this study. The subjects were divided into 3 groups, with 32 in experimental group I, 30 in experimental group II, and 32 in the control group. Subjects in experimental group I were treated by a dental hygienist with professional oral healthcare and received daily oral care from caregivers who had completed elderly oral healthcare course. Subjects in experimental group II received daily oral care from caregivers who had completed elderly oral healthcare course. Control group received daily oral care from caregivers. These 3 groups were tested for dental plaque, halitosis, tongue coating, and salivary flow at baseline, and after 4 and 12 weeks of treatment. There were significant differences in the dental plaque index between the groups, mediate times, and mediate methods, in halitosis between the mediate methods, and in tongue coating between the mediate times, as well as the mediate methods. Finally, salivary flow was significantly different with regard to mediate methods between experimental group II and the control group. Therefore, to improve the oral health condition of elderly residents, involvement of a part-time dentist and scheduled professional oral healthcare are necessary. Furthermore, elderly oral healthcare education for nursing staff, including managers, should be provided.

Applicability Analysis of an Improved Multistep Steel Pipe Grouting Method in Shallow Depth Railway Tunnels in Considering Safety and Constructability (저토피 철도터널구간의 안전 및 시공성을 고려한 개선된 강관다단 그라우팅 공법 적용성 분석)

  • Kim, Nakseok;Choi, Gisung;Kim, Seokhyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.97-103
    • /
    • 2020
  • The newly improved multistep steel pipe grouting method was applied to an existing steel pipe-reinforced grouting method. It was applied in order to prevent a damage caused by ground failure from excessive grouting pressure in a tunnel construction. The tunnel goes under a highway and a ramp connected to a rest area on OO highway with 11.3~12.1 m depth cover and is a part of roadbed facility construction section ordered by OO public corporation. The improved grouting method provides pre-construction work condition assessment technique through new water injection limit test and grouting effect assessment technique by grouting type assessment. It also includes assessments on interval of joints, appropriate grouting pressure, and optimal operation time to be applied to current operations. Application of the grouting method allowed the smooth road management in shallow-depth grouting construction area located upper part of tunnel excavation. Moreover, the possibility of the application of the method not only to shallow-depth grouting construction but also to various steel pipe-reinforced grouting constructions was confirmed.

A Plan of Spatial Data Modeling for Tidal Power Energy Development (조력에너지 개발을 위한 공간데이터 모델링 방안)

  • Oh, Jung-Hee;Choi, Hyun-Woo;Park, Jin-Soon;Lee, Kwang-Soo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.3
    • /
    • pp.22-35
    • /
    • 2011
  • Incheon Bay has a suitable condition for tidal power generation due to the high tidal range by topographical effect. Therefore a study on the technology development for tidal energy utilization has been promoted since 2006. It is needed to deduce optimal alternatives to determine the suitable location of facilities for tidal power generation and to reduce the environmental damage from development. In order to carry out efficiently this mission, spatial information system is essential to manage and use various spacial elements related to the development and conservation. In this study, for the development of tidal energy, spatial data could be defined as three kinds of dataset. Fundamental dataset is defined as spatial data such as tide, tidal current, wave, erosion and sedimentation. Framework dataset is composed of topographical map, facility map and bathymetry. The reference dataset is composed of marine ecology and environment having the characteristics of thematic map. This study is mainly aimed at establishing methodology of conceptual spatial data modeling classifying as essential data model and optional data model through the definition of the components of spatial data.

Aerodynamic Design of EAV Propeller using a Multi-Level Design Optimization Framework (다단 최적 설계 프레임워크를 활용한 전기추진 항공기 프로펠러 공력 최적 설계)

  • Kwon, Hyung-Il;Yi, Seul-Gi;Choi, Seongim;Kim, Keunbae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.173-184
    • /
    • 2013
  • A multi-level design optimization framework for aerodynamic design of rotary wing such as propeller and helicopter rotor blades is presented in this study. Strategy of the proposed framework is to enhance aerodynamic performance by sequentially applying the planform and sectional design optimization. In the first level of a planform design, we used a genetic algorithm and blade element momentum theory (BEMT) based on two-dimensional aerodynamic database to find optimal planform variables. After an initial planform design, local flow conditions of blade sections are analyzed using high-fidelity CFD methods. During the next level, a sectional design optimization is conducted using two dimensional Navier-Stokes analysis and a gradient based optimization algorithm. When optimal airfoil shape is determined at the several spanwise locations, a planform design is performed again. Through this iterative design process, not only an optimal flow condition but also an optimal shape of an EAV propeller blade is obtained. To validate the optimized propeller-blade design, it is tested in wind-tunnel facility with different flow conditions. An efficiency, which is slightly less than the expected improvement of 7% predicted by our proposed design framework but is still satisfactory to enhance the aerodynamic performance of EAV system.

A Study on B Class Fire Extinguishing Performance of Air Ratio in the Compressed Air Foam System (압축공기포 소화설비의 공기포비에 따른 B급 소화성능 연구)

  • Lee, Jang-Won;Lim, Woo-Sub;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.8-14
    • /
    • 2013
  • This research is to evaluate the fire extinguishing performance at a mixing ratio of pressurized air in the fire extinguishing system of compressed air foam (CAF) which injects compressed air into foam liquid and then discharging. The experimental device is made use of exclusive foam extinguishing facility for compressed air foam that is produces based on Canada National Laboratory and UL 162 standard, apply model of oil fire (B Class) 20 unit in accordance with "Standard of Model Approval and Product Inspection for Fire Extinguishing Agent" to the fire Extinguishing model. Compressed air is injected through the air mixture and study the tendency depending on increasing air foam ratio 1 : 4, 1 : 7, 1 : 10. In addition, the comparison experiments between synthetic surfactants foam and AFFF carry out with it at the air foam ratio 1 : 4. As a result, in the condition of same discharging flow, fire extinguishing effect of AFFF is the fastest at the air foam ratio 1 : 7 and the slowest at 1 : 10. Moreover, the fire extinguishing effect of AFFF in the comparison expeiments between AFFF and synthetic surfactants foam is faster than the other.

Analysis of Interior Color Status in Facilities for the Elderly - Focused on the 10 Facilities in Seoul and Kyunggi region- (고령자를 위한 실내환경의 색채적용 평가 -서울ㆍ경기도 지역 10개 양로시설을 중심으로 -)

  • 천진희
    • Archives of design research
    • /
    • v.16 no.4
    • /
    • pp.313-322
    • /
    • 2003
  • The residential and welfare facilities for the elderly are continuously increasing due to change of value on family under situation of aging population increase. And it is predicted that accommodation capacity of facilities for the elderly and its rate those facility takes compared to whole social welfare facilities will be accelerated considering past increase speed. On the other hand, about 60% of elderly people have low physical and mental level almost dose to handicapped people therefore special environmental concerns helping their independent living are necessary. The purpose of this study is to analyze whether facilities for the elderly are adequate to accommodate their request condition by understanding color among environmental factors is one of most important factor for smooth understanding, communication and psychological remedy effect for thou. For this purpose, importance and effect of color and visual characteristic and reaction to color in elderly environment are researched through documents and visited 10 facilities in Seoul and Kyunggi region to research interior color status. And measuring of color on 5 main spaces of the facilities such as lobby/lounge, corridor, dining room, bedroom, stairway/ramp are done under analysis of its functional and aesthetic level based on Moon & Spencer's color theory.

  • PDF