• Title/Summary/Keyword: Facilities.Equipment

Search Result 1,373, Processing Time 0.024 seconds

A Study on Deterministic Utilization of Facilities for Allocation in the Semiconductor Manufacturing (반도체 설비의 효율성 제고를 위한 설비 할당 스케줄링 규칙에 관한 연구)

  • Kim, Jeong Woo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.1
    • /
    • pp.153-161
    • /
    • 2016
  • Semiconductor manufacturing has suffered from the complex process behavior of the technology oriented control in the production line. While the technological processes are in charge of the quality and the yield of the product, the operational management is also critical for the productivity of the manufacturing line. The fabrication line in the semiconductor manufacturing is considered as the most complex part because of various kinds of the equipment, re-entrant process routing and various product devices. The efficiency and the productivity of the fabrication line may give a significant impact on the subsequent processes such as the probe line, the assembly line and final test line. In the management of the re-entrant process such as semiconductor fabrication, it is important to keep balanced fabrication line. The Performance measures in the fabrication line are throughput, cycle time, inventory, shortage, etc. In the fabrication, throughput and cycle time are the conflicting performance measures. It is very difficult to achieve two conflicting goal simultaneously in the manufacturing line. The capacity of equipment is important factor in the production planning and scheduling. The production planning consideration of capacity can make the scheduling more realistic. In this paper, an input and scheduling rule are to achieve the balanced operation in semiconductor fabrication line through equipment capacity and workload are proposed and evaluated. New backward projection and scheduling rule consideration of facility capacity are suggested. Scheduling wafers on the appropriate facilities are controlled by available capacity, which are determined by the workload in terms of the meet the production target.

Analysis of Medical Resources according to number of beds in Korean General Hospitals (국내 종합병원의 병상규모에 따른 의료자원 분석)

  • Cho, Junyoung;Yang, Naewon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.2
    • /
    • pp.27-35
    • /
    • 2017
  • Purpose: This study analyzed the status of general hospitals as an expanded concept of medical resources including medical staff and equipment. The purpose of this study is to provide a basic for the feasibility study of the scale and establishment of facility guidelines at the planning stage of general hospitals. Methods: The subjects of this study were limited to general hospitals. The status of medical resources was based on the data of the Health Insurance Review and Assessment Service. The number of beds, doctors, nursing grades and major medical equipment were surveyed in 335 general hospitals. Results: 1) The characteristic of general hospitals varies depending on the number of inpatient beds. To be concrete, there were differences in the number of medical staffs and equipments in general hospitals based on 300 500 800 1,000 beds. 2) As the number of hospital beds increases, the number of medical staff increases more than medical equipment and facilities. Medical equipment and facilities remain constant, even when the number of beds increases. On the other hand, the number of medical staff increased about 1.5 times in each level. Implications: Architectural plans for medical staff should be considered differently depending on the number of beds. In particular, architectural planning and facility guidelines should be applied differently based on 300 and 500 beds.

Graphical display technology of internal impact in remote monitoring and simulation system (원격 모니터링 및 시뮬레이션 시스템의 내부 충격 그래픽 표시 기법)

  • Yoon, Ji-young;Lee, Hyo-jai;Woo, Deok-gun;Jang, Moon-su;Kim, Cheol-hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.574-576
    • /
    • 2022
  • In this paper, we developed a technique to graphically display impact effects for remote monitoring or simulation systems. A remote monitoring or simulation system is being used to find a repair time or to prevent accidents while inspecting equipment or facilities in an industrial site in real time. These systems provide visual information to users so that they can analyze problem situations. The technique proposed in this paper is a method of modeling equipment and facilities using 3D graphics, and displaying the location of impact and damage occurring in the equipment inside using volume rendering. This technique has the advantage that the problem can be identified more accurately by displaying the impact animation by volume rendering at the location of the impact and damage inside the equipment. And it is expected that the problem situation can be identified more quickly through more intense visual effects.

  • PDF

A study on the Risks of Using Filtration Facilities at the Organic Light Emitting Diode(OLED) and Its Preventive Measures (유기발광다이오드(OLED) 소재 제조 현장 여과 설비사용 위험성 및 개선 방안 연구)

  • Jong-Ku Kwak;Chankyu Kang
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.1-11
    • /
    • 2023
  • The size of the OLED material market is expected to grow from $1.1 billion in 2019 to $2.3 billion in 2023, with an average annual sustainable growth of more than 19%. Among the facilities mainly used by OLED material manufacturers, accidents such as fire, explosion, and leakage frequently occur when using filtration equipment, so it is necessary to improve the risk when using filtration equipment. In this study, it was divided into four main processes, namely, assembly and disassembly process, filtration process, wet cake recovery process, and washing process in order to derive the risks associated with the use of filtration equipment. Hazard factors were derived by conducting accident case investigations, preliminary interviews, and surveys. For the analysis of questionnaire results, statistical analysis such as frequency analysis and Pearson chi-square test analysis was performed using SPSS 21, and risk improvement measures were suggested using the analyzed results. It is expected that this study will serve as a basis for dealing with safety and risk factors that may occur as the size of the OLED market expands.

International Sanction on North Korea and Inter-Korea Fisheries Cooperation (국제사회의 대북제재와 남북수산협력)

  • Park, Joon-Mo
    • The Journal of Fisheries Business Administration
    • /
    • v.50 no.4
    • /
    • pp.11-28
    • /
    • 2019
  • In this study, the Inter-Korea Fisheries Cooperation Project was divided into four categories: North Korea's Fisheries Infrastructure Development Project, Fisheries Cooperation Project, Human Exchange Project, and North Korea Fisheries Investment Project. First, North Korea's fisheries infrastructure development projects include North Korea's fisheries resource research project, it's fisheries resource development project, and joint enforcement on illegal operation of Chinese ships. Second, fisheries cooperation projects include the operation of the North-South common fish area in the West Sea, the fishing project in North Korea's East sea, and the import of North Korean seafood. Third, human exchange projects include training of aquaculture technicians in North Korea, technology transfer and training of fishing vessels, and boarding of North Korea's fisherman in Korean fishing vessels. Fourth, North Korea's fisheries investment projects include aquaculture facilities and aquaculture feed support, aquatic product processing facilities and technology transfer, and fishery equipment support. However, as international sanctions are maintained in the international community to North Korea, Inter-Korea Fisheries cooperation, however, should be promoted according to the level of easing of international sanctions as international sanctions are maintained in the international community to North Korea. First, North Korea's fisheries resource research project, North Korea's fisheries resource creation project, joint enforcement on illegal operation of Chinese ships, and operation of the common fish area in the West Sea can be promoted if international sanctions are maintained at present, promote North Korea's fisheries resource research project. Second, boarding of North Korean's fisherman in Korean fishing vessels, conducting the fishing project in North Korea's East sea, and importing North Korean seafood can be aided if commercial transactions are possible with North Korea. Third, South Korea will support aquaculture facilities and aquatic feed, fisheries processing facilities and technology transfer, fishery equipment support, training of fisheries and aquaculture technicians, fishery fishing technology transfer, and training of fisherman when a comprehensive economic cooperation project is possible with North Korea.

A Study on Factory Monitoring System based on Manufacturing Facility Condition Diagnosis Algorithm (제조설비 상태 진단 알고리즘 기반의 공장 모니터링 시스템에 대한 연구)

  • Song, Enjoo;Song, Kyogin;Ko, Dongbeom;Park, Jeongmin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.2
    • /
    • pp.261-269
    • /
    • 2020
  • This paper introduces a facility simulation system for efficient error detection of smart factories. The facility simulation system, which can infer and solve errors autonomously when analyzing the relationship between plant facilities, is one of the important technologies for constructing a smart factory with high productivity. In order to implement this autonomic control system, it is necessary to be able to identify the status of facilities and analyze the relationship between facilities through the data of factory facilities. Therefore, in this paper, we design and develop a simulation program that can detect the equipment that causes the process error when an error occurs based on the process scenario using the defined equipment status. The simulation shows that the error inference process based on the process map and facility status is more efficient than the general error inference process. This simulation program provides an intuitive view of the reasoning and resolution of facility failures.

A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings (현행소방시설설치기준의 분석과 개선방안에 관한 연구)

  • 정병재;이경회
    • Fire Science and Engineering
    • /
    • v.4 no.2
    • /
    • pp.3-13
    • /
    • 1990
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the ]after fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern Higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First. We are going to look history of the fire protection system and change course of that with the year and facility. Second, We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF

Indoor Air Quality in Various Type of Public Facilities at Honam Province (호남지역의 다중이용시설별 실내공기질 실태 조사)

  • Seo, Byeong-Ryang;Jeong, Man-Ho;Jeon, Jun-Min
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.387-397
    • /
    • 2006
  • This study was performed to investigate the characteristics of indoor air quality(IAQ) in 91 public facilities from September 2004 to March 2005 in the Honam province(Chonnam, Gwangju). The measured air pollutants are $PM_{10}$, formaldehyde(HCHO), CO, $CO_{2}$ and total suspended bacteria(TSB), the maintenance standard materials of IAQ management law established by ministry of environment in Korea(MOE). We also surveyed establishment and operation of ventilation equipment. It was measured $1.2m{\sim}1.5m$ on the floor between 8 o'clock AM and 7 o'clock PM. As the result, $PM_{10}$ and CO was showed the highest concentration, $188.89{\mu}g/m^{3}$, 8.67 ppm, at the indoor parking. The concentration of HCHO was the highest in large store and steamer room. The concentration was respectively $118.70{\mu}g/m^{3}\;and\;113.21{\mu}g/m^{3}$. The concentration of $CO_{2}$ was the highest at the reading room of the library on the condition of natural ventilation. The concentration of $CO_{2}$ was 1,816 ppm and higher than the IAQ standards established by MOE. The TSB was just measured in the hospital and silver town. It was the highest at the admission room of hospital. The concentration of TSB was $766CFU/m^{3}$. The public facilities of this study were not exceed each maintenance standards except $CO_{2}$ but it was surveyed that the management will be needed about some air pollutant according to target facilities.

Part II A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings (현행소방시설설치기준의 분석과 개선방안에 관한 연구II)

  • 정병재;이경회
    • Fire Science and Engineering
    • /
    • v.5 no.1
    • /
    • pp.5-14
    • /
    • 1991
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it Is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the latter fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First, We are going to look history of the fire protection system and change course of that with the year and facility. Second. We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have to reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use count about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF

Study on the Technological Levels for the Industries Manufacturing the Machinery and Equipment for Livestock Production Facilities (축산시설의 기계 및 설비 산업의 기술 수준 분석 연구)

  • 장동일;장홍희
    • Journal of Animal Environmental Science
    • /
    • v.2 no.1
    • /
    • pp.13-25
    • /
    • 1996
  • This study was conducted to analyze the technological levels of the domestic industries manufacturing the machinery and equipment for livestock production facilities and to lay out a scheme for upgrading the technical improvement. The results of this study are as follows : 1 . According to the study results, the technological levels of the domestic industries for livestock production facilities lag far behind those of the advanced countries in this field. 2. It was found that the ratio engaged in the areas of R&D was 10.7% and lower than that engaged in the other areas and the ratio of junior college graduated engineers engaged in the areas of research and design was 44.4%. Therefore, the amounts of investment for the areas of R&D and design should be increased. 3. In the design area, it was found from the study that the most weakness technologies which should be developed in near future were the universal harvester and the mechanical designing. Therefore, the multipurpose universal harvester suitable to the domestic farmland conditions should be developed and strength, hardness, and durability of materials in the mechanical designing should be improved.

  • PDF