• Title/Summary/Keyword: Facilities of Gas Fire Extinguishing

Search Result 9, Processing Time 0.026 seconds

Influence of the Nozzle Contraction Angles of Gaseous Extinguishing Systems on Discharge Noise (가스계 소화시스템 노즐 수축각이 방출소음에 미치는 영향)

  • Kim, Yo-Hwan;Yoo, Han-Sol;Hwang, In-Ju;Kim, Youn-Jea
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.77-82
    • /
    • 2019
  • Fire extinguishing systems are essential equipment in all indoor facilities to address unexpected fire scenarios, and appropriate fire extinguishing agent should be used depending on the place and object to protect. Among these, gaseous fire-extinguishing systems are used to protect electronic equipment. Therefore, inert gases that do not undergo chemical reactions are used mainly in those systems. On the other hand, recently, owing to the high integration of electronic equipment, there are some cases, in which large noise generated from gaseous systems damage the electronic equipment. In this study, numerical analysis of the discharge noise with various nozzle contraction angles was carried out to improve the gas fire extinguishing system. Numerical analysis was carried out using ANSYS FLUENT ver 18.1. The causes of the noise were elucidated using the swirl distribution. The noise level of the modified model was reduced by approximately 6 dB compared to the reference model, which is similar to the result of a previous study, confirming the validity of the method.

대규모건축물적용 특수방재설비

  • 이성모
    • Fire Science and Engineering
    • /
    • v.10 no.4
    • /
    • pp.37-42
    • /
    • 1996
  • The "Intelligent Fire detecting and Extinguishing System" is an up-to-date fire protection system for modern high-rise buildings, international airports, enormous industrial facilities, dome stadiums such as specific areas in which the application of our local fire protection regulation could not be satisfied. The state-of-the art initiating devices communicated with sophisticated network control panels enable peoples to get reliable and powerful suppressions using water or gas, providing absolute protection. The Intelligent Water Cannon System, the Low Pressure $CO_2$ System and the MXL Networking Fire Alarm System introduced in this paper accomplish the dynamic protection for the special hazards.

  • PDF

A Study on Clean Agents for Halon Replacement in the Portable Extinguisher with CO2 as an Expellant Gas (이산화탄소를 가압원으로 하는 할론대체 소화기용 청정소화약제에 대한 연구)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.51-55
    • /
    • 2019
  • To prevent ozone depletion caused by CFCs, the replacement of Halon with clean agents has been developed in the fire protection field along with refrigerants, detergents, and foaming agents. The alternatives for Halon 1211 have been developed in the portable fire extinguisher area and HCFC-123 is used widely as a clean fire extinguishing agent. The type of expellant gas is important because their own vapor pressure is low. In this study, HCFC-123, HCFC-124, HFC-125, and Novec-1230 were selected as fire extinguishing agents and CO2, which is expected to improve the fire extinguishing ability, was chosen as the expellant gas. For each agent, experiments changing the agent and CO2 amount were carried out and HCFC-123 showed a good result, as expected. The extinguisher, HCFC-123 of 1.5 kg, showed the same ability to suppress a class A and B fire as the extinguisher, HCFC-123 of 2.5 kg, which is currently sold on the market. According to this result, the expellant gas has a subsidiary fire extinguish effect. This can reduce the amount of HCFC fire extinguishing agent, which is categorized in the phase-out alternatives, and is a more eco-friendly and economical fire extinguisher than the previous one. This study can also help solve the problems of CO2 fire extinguishers for class B and C fires, and can be used to extinguish electric and electron facilities fire, which contains large amounts of class A fire combustibles.

Suggestion of the Attached Piping Material Rate for the Mechanical Fire Protection Facilities in Office Buildings (업무용 건축물의 기계소방시설 배관 부속자재 요율 제시)

  • Park, Lyool;Park, Kyung-Soon;Yoon, Hang-Mook
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.1-8
    • /
    • 2018
  • In generally, the estimation work regarding building mechanical service system in comparison with other architectural estimations is time-consuming, and the process is continuously getting more difficult because of the increased usage of the attached piping materials such as fittings and supports in addition to their complicated construction processes. In order to improve this problem, the Korean authority provides a simple method to estimate the attached material rate regarding the main piping material, which is the most time-consuming work in the architectural mechanical estimation. However, to be an applicable method on construction site, a proper conversion rate of the attached piping material is still required for the proposed method regarding building usage and working types. Therefore, the purpose of this research is the suggestion of the material and labor cost rate of the attached piping materials such as the fittings and supports by work types and fitting methods of indoor fire, sprinkler, and extinguishing gas piping work of mechanical fire protection facilities in office buildings that have been designed after 2010.

Policy Direction for Fire Products Life Expectancy Legislation (소방용품 내용연수 제도화 정책방안)

  • Baek, Chang Sun;Park, In-Seon
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.111-120
    • /
    • 2016
  • This study is intended to provide legislative direction for fire products life expectancy. Domestic and international laws relating to fire products life expectancy have been reviewed, and the results of a Fire Safety Manager Consciousness (FSMC) survey were analyzed. The FSMC survey has been designed in order to assist with the establishment of appropriate fire safety policy. A questionnaire survey was conducted with 660 fire safety administrators from 17 municipal and provincial districts, with the intention of gaining expertise on the extension of life-span for 32 fire products. The survey also asked for candidates opinions on future policy direction. Based on the survey results and the review of policies within other nations, we have devised a set of policy issues with the intention of extending the life-span of fire-safety items. The survey result revealed that 79.3% of Fire Safety Managers (FSMs) concurred with the establishment of legislation regarding the maintenance and correct care of fire-safety products. Overall, over 30% of FSMs were in favor of regulations regarding Ddry chemical fire extinguishers (77.3%), fire detectors (44.6%), fire hoses (44.4%), gaseous agent fire extinguisher (40.6%), automatic descending life lines (36.2%), exit lights (35.9%), air respirators (35.9%), extinguishing systems for residential cooking facilities (33.9%), automatic spray-type extinguishing units (33.9%), emergency lights (31.2%), and gas leakage detectors (30.7%). Especially, among these, dry chemical fire extinguishers (60.0%), detectors (20.0%), and fire hose (18.8%) were identified as the fire products primarily in need of maintenance legislation. The general consensus is that fire products older than 10 years need to be replaced. Based on the survey results, there was general agreement that fire product life expectancy is in need of legislation. This study recommends the introduction of fire product life expectancy legislation in phases.

The Proposal of Installations Standards for Commercial Kitchen Automatic Fire System (상업용 주방자동소화장치 도입과 설치기준 제안)

  • Lee, Changwoo;Kang, Dowoo;Oh, Seungju;Ham, Eungu;Cho, Yongsun
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.1
    • /
    • pp.89-97
    • /
    • 2016
  • According to the statistics released by Ministry of Public Safety and Security, the number of restaurant fires in Korea reached around 2,400 and 169 damages of human life and damages to property was approximately over $8.8 billion for recent 3 years. It could be desirable having automatic commercial fire-extinguishing equipment at commercial facilities excluding housing facilities for the safety, applying at the place first where it has been more risky and expected fire can be occurred relatively because economical burden can be accelerated. In order to do this, adjust its level to meet the same level of the kitchen for 'Specific Target for Fire Fighting' that "gas leak alarm" has be equipped relevant regulations and it is considered and reasonable to expand the limit of application gradually.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Development of a Tool for Predicting the Occurrence Time of BLEVE in Small LPG Storage Tanks (LPG소형저장탱크 BLEVE 발생 시점 예측 툴 개발)

  • Chae, Chung Keun;Lee, Jae Hun;Chae, Seung Been;Kim, Yong Gyu;Han, Shin Tak
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.74-83
    • /
    • 2020
  • In Korea, about 110,000 LPG small storage tanks of less than three tons have been installed in restaurants, houses and factories, and are used as LPG supply facilities for cooking, heating and industrial use. In the case of combustible liquefied gas storage tanks, the tank may rupture due to the temperature increase of the tank steel plate (approximately 600℃) even when the safety valve is operating normally, causing large-scale damage in an instant. Therefore, in the event of a fire near the LPG small storage tank, it is necessary to accurately predict the timing of the BLEVE(Boiling Liquid Expanding Vapour Explosion) outbreak in order to secure golden time for lifesaving and safely carry out fire extinguishing activities. In this study, we have first investigated the results of a prior study on the prediction of the occurrence of BLEVE in the horizontal tanks. And we have developed thermodynamic models and simulation program on the prediction of BLEVE that can be applied to vertical tanks used in Korea, have studied the effects of the safety valve's ability to vent, heat flux strength of external fires, size of tanks, and gas remaining in tanks on the time of BLEVE occurrence and have suggested future utilization measures.