• Title/Summary/Keyword: Facilities Management Corporation

Search Result 247, Processing Time 0.026 seconds

Distribution Transformer Statistical Expected Life Evaluation and Removal Adequacy Review (배전 변압기의 통계적 기대 수명 평가 및 초기 고장제거 적정성 검토)

  • Chong-Eun, Cho;Sang-Bong, Kim;On-You, Lee;Kang-Sik, Kim
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.79-86
    • /
    • 2022
  • Recently, the amount of maintenance is increasing due to the aging of power facilities, but the budget is constrained. Therefore, the importance of asset management that selects replacement priorities based on the failure probability and enhances investment effects is increasing. Because the number of distribution transformers is very large, the proportion of investment cost is very high. Therefore, it is important to select the investment priority by evaluating the reliable remaining life based on the failure probability. This paper evaluates the statistical expected life using the failure data of distribution transformers for the last 11 years and the current operation data. The hazard rate of distribution transformer and MV cable was compared with each other and the adequacy of early failure removal was reviewed and the statistical expected life corresponding to the cumulative failure probability B3% was calculated.

SUGGESTING IMPROVEMENT METHODS OF FORM WORK FOR COST REDUCTION IN THE MID-RISE APARTMENT HOUSING

  • Jeongseok Lee;Seunghee Kang;Gunhee Cho;Jeongrak Sohn;Jongdae Bang
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1608-1614
    • /
    • 2009
  • In recent days, the study of urban regeneration has been conducting with purposeful and sincere intent starting out with the residential environment improvement works. Within the range of urban regeneration, the low-cost housing technology means development of totally-integrated housing technology that may be applied to the regeneration project, especially for the rundown areas where infrastructure facilities in the urban zone have been degraded and obsoleted. In line with this, among many and varied methods in order for realization of the low-cost housing as a part of urban regeneration project, this study should like to propose an improvement methods of the key technologies in relation to the construction works by type of work with which construction costs (directing cost) would be reduced. And, in order to elicit the method for element technology that has been developed and improved in the most optimal manner centering on the selected construction work by the type of work, the researcher conducted comparative review of summary of element technologies related to the construction works concerned, characteristics, and construction method thereof. In particular, the researcher investigated the expenses (construction cost and labor cost), constructions (contractibility and productivity), safety, quality of works, and the technical status in environmental aspects, and the researcher also conducted analyses and evaluations thereof.

  • PDF

TECHNICAL PROPOSAL BASED COST REDUCTION BIDDING SYSTEM FOR SUPPLYING AFFODABLE HOUSING

  • Seunghee Kang;Jeongseok Lee;Gunhee Cho;Jeongrak Sohn;Jongdae Bang
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1433-1439
    • /
    • 2009
  • Best value is the ultimate goal of the owner and can thus have diverse meanings according to the project characteristic, owner's purpose, user groups' payment capability, etc.. Recently, resettlement problems of the marginalized members in the urban regeneration area have been issued in Korea because they have no capability to purchase (or lease) redeveloped housing (or apartment). It means that a minimized production cost for reducing supply price of housing is a key factor in establishing the best value of the marginalized members. The lowest-price bidding system serves the purpose of ensuring a minimized production cost, but due to the low-cost investments, it creates various problems, such as sloppy construction, lowered quality, an increased LCC, and worsening profitability for builders. Thus, to help them resettle, it is necessary to supply affordable housing geared towards a certain appropriate quality and minimum construction costs. Towards this end, this study aimed to propose a cost reduction bidding system based on a technical proposal. The proposed technical-proposal-based cost reduction bidding system consists of the following components: work-unit-based, project-unit-based, and construction-period-reducing technical proposals. These components are evaluated to select the best bidder for a given project. The technical proposal based cost reduction bidding system proposed herein is expected to provide facilities with appropriate supply prices and appropriate quality levels, to bolster the technological competitiveness of builders.

  • PDF

Evaluation of the Effectiveness of Low Impact Development Practices in an Urban Area: Non-point Pollutant Removal Measures using EPA-SWMM (EPA-SWMM을 이용한 LID 기법의 비점오염 저감효과 분석)

  • Cho, SeonJu;Kang, MinJi;Kwon, Hyeok;Lee, JaeWoon;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.466-475
    • /
    • 2013
  • Non-point source pollution management is one of the most important issues in Korean water quality/watershed management. In recent years, Low Impact Development (LID) has emerged as an effective approach to control stormwater in an urban area. This study illustrates how to design and evaluate the effect of non-point pollutant management using EPA-SWMM LID module and suggests design parameters for modeling LID facilities. In addition, optimal installation locations of LID can be determined by a simple distributed hydrologic model by using SWMM for a long-term.

A Study on Development and Construction Methods of the Inorganic Floor Finishing Material of Hazardous Material Storage Facilities (위험물 저장시설의 무기질 바닥마감재와 이를 이용한 시공방법에 관한 연구)

  • Oh, Dong-Seok;Yu, Chul-Hee;Kim, Byung-Duk;Kim, Heum;Park, Sang-Min
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.35-43
    • /
    • 2014
  • Usage of the inorganic floor finishing material can be advantageous to overcome some problems of traditional organic-based floor finishing material used for hazardous material storage facilities. A spark can be produced by physical impact between the flooring and the flooring disposal equipment while removing the existing flooring. In order to prevent a fire hazard, which may be caused the spark, it is feasible that a construction can be implemented without removing the existing flooring. Moreover, the top coating material containing an antistatic agent is effective to prevent secondary damage caused by static electricity after finishing the construction of the flooring. Therefore, the inorganic floor finishing material of the this study is expected to be beneficial for safety management and economical aspect for inspectors.

A Study on the Current Status and Improvement of Facilities Management Corporations' Records Management: Focused on the Gyeonggi Area (시설관리공단의 기록물관리 실태 및 개선방안에 관한 연구: 경기지역을 중심으로)

  • Cho, Jin-Rae;Chung, Yeon-Kyoung
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.20 no.2
    • /
    • pp.1-20
    • /
    • 2020
  • The record management of public enterprises under basic local governments has been in a blind spot while many studies have been mainly conducted on public enterprises directly managed by the National Archive of Korea and local public enterprises located in metropolitan cities. Hence, this study aims to examine the current status of Facilities Management Corporations' records management in local cities and counties of the Gyeonggi area, and to suggest improvement measures with some basic data as a reference. After conducting a survey and telephone interviews with eight record management officers from Facilities Management Corporations, the results of this study found that record management of them was in hard conditions with many improvements needed.

A Empirical Study on Applying Ubiquitous Technology for Gas Safety Management (U-기반 가스안전관리의 기술을 적용을 위한 실증적 연구)

  • Oh, Jeong-Seok;Choi, Kyung-Suhk;Kwon, Jeong-Rock
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.63-68
    • /
    • 2008
  • The ubiquitous technology is capable of innovating various area to constructing intelligent and network to all objects. This technology can construct network infrastructure to facilities for applying legacy industry and need to develop intelligent service that analyze context-aware through network. This paper derive and propose the introduction range of ubiquitous technology, which should be testified and analyzed network, and studied the detection and analysis of information for managing gas facilities. We investigate the current status of gas facilities and automatic reading system, testing and analyzing wireless personal area network and mobile communication by scalability, self-configuration, connection in underground. Furthermore, we propose modelization method for intelligent service and derive the introduction range for applying ubiquitous technologies for managing gas facilities.

  • PDF

Development and Application of Water Balance Network Model in Agricultural Watershed (농업용수 유역 물수지 분석 모델 개발 및 적용)

  • Yoon, Dong-Hyun;Nam, Won-Ho;Koh, Bo-Sung;Kim, Kyung-Mo;Jo, Young-Jun;Park, Jin-Hyeon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.66 no.3
    • /
    • pp.39-51
    • /
    • 2024
  • To effectively implement the integrated water management policy outlined in the National Water Management Act, it is essential to analyze agricultural water supply and demand at both basin and water district levels. Currently, agricultural water is primarily distributed through open canal systems and controlled by floodgates, yet the utilization-to-supply ratio remains at a mere 48%. In the case of agricultural water, when analyzing water balance through existing national basin water resource models (K-WEAP, K-MODISM), distortion of supply and regression occurs due to calculation of regression rate based on the concept of net water consumption. In addition, by simplifying the complex and diverse agricultural water supply system within the basin into a single virtual reservoir, it is difficult to analyze the surplus or shortage of agricultural water for each field within the basin. There are limitations in reflecting the characteristics and actual sites of rural water areas, such as inconsistencies with river and reservoir supply priority sites. This study focuses on the development of a model aimed at improving the deficiencies of current water balance analysis methods. The developed model aims to provide standardized water balance analysis nationwide, with initial application to the Anseo standard watershed. Utilizing data from 32 facilities within the standard watershed, the study conducted water balance analysis through watershed linkage, highlighting differences and improvements compared to existing methods.

A Study on the Potable Water Purification System with Pre-Ozone and Ultra Filtration Membrane of Hollow Fiber Type (전오존과 중공사형 한외여과막을 이용한 간이정수처리시스템에 관한 연구)

  • Kim, Min-Kuk;Chun, Yang-Kun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.196-204
    • /
    • 2005
  • The objective of this study is to evaluate the possibility to apply pre-ozone and membrane system for drinking water. This system is improved in fouling control by pre-ozone system. It is composed of ultrafiltration hollow fiber type membrane and ozone reactor. The result of this study is that the flux is increased about 10.7% and decreased in TMP by the pre-ozone. Also, backwashing pressure decreased about 18%. The optimum concentration of residual ozone is 0.3~0.5 ppm. During the period, the recovery ratio of this system was turned out to be 90% as the flowrate of effluent is $67.1m^3/day$. When the TMP and backwashing pressure was $0.85kg/cm^2$ and $1.10kg/cm^2$, this system was stable without sudden fouling. Finally, the quality of effluent is satisfied the guidelines for potable water quality such as turbidity, color, E.coli, Mn, Al, Fe and so on.

Analysis of the Status of Safety Management of Photovoltaic Power Generation Facilities (태양광발전설비 안전관리 현황 분석)

  • Kim, Wan-su;Park, Sang-June;An, Seong-ryeol
    • Current Photovoltaic Research
    • /
    • v.7 no.2
    • /
    • pp.38-45
    • /
    • 2019
  • In this paper, we analyzed the present status of the safety manager and safety assurance aspects through a complex analysis on the operational aspects, marketability and electrical safety aspects of photovoltaic power generation facilities. In the analysis of the equipment status, we analyzed the status and operated status of the installed PV system in Korea and the correlation between the safety manager and the accident. In addition, we analyzed the direction of the ESS through the analysis of the installation status of the ESS, and applied it to the interpretation part of the ESS associated with the solar power generation. The status of the electric safety manager can be used to analyze the data for selecting the electric safety manager by capacity by analyzing the accident status, the electric safety manager operation status, the safety management time by capacity, and the electric safety manager market.