• Title/Summary/Keyword: Facilities Management Corporation

Search Result 247, Processing Time 0.025 seconds

THE DEVELOPMENT OF BUILDING MAINTENANCE SYSTEM FOR DETERMINING PRIORITIES OF PUBLIC FACILITY REPAIRS & REPLACEMENT (I)

  • Chun-Kyong Lee;Tae-Gab Jung;Byong-Jin Yu;Tae-Keun Park
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.376-381
    • /
    • 2011
  • In Korea Water Resources Corporation (K-Water) has seen four problems rising in four aspects of property management of approximately 1,300 buildings scattered through put to country. To solve these, ground data for repair and replacement works to be conducted for prevention will be prepared and building maintenance system (hereinafter referred to as PBMS) intended to record related repair and replacement work histories and calculate LCC of the related these items will be developed. PBMS, a web-based system, will be developed for users' convenience and data monitoring in real time. To sum up, PBMS are expected to maximize efficiency in four aspects including the establishment of repair and replacement work plans for prevention, history management, DB for predicting future work to be occurred and enable the determination of priorities by being developing into facility condition assessment systems through the results of analysis of repair and replacement histories and LCC.

  • PDF

Development of Transmission & Substation Geographic Information System (송변전지리정보시스템(TGIS) 개발 추진현황 및 향후과제)

  • Ahn, Tae-Hyung;Moon, Bong-Soo;Kwon, Oh-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.575-577
    • /
    • 2005
  • KEPCO has developed Transmission & Substation Geographic Information System(TGIS) since 2000. TGIS is the system for the management of transmission and substation facilities on the geographic basis. This paper provides a brief introduction to TGIS.

  • PDF

Estimation of Emission and Development of Emission Factor on Greenhouse Gas (CO2) of the Combustion Facilities (연소시설의 온실가스(CO2) 배출량 산정 및 배출계수개발)

  • Kim, Hong-Rok;Jin, Byong-Bok;Yoon, Wan-Woo;Kwon, Young-Sung;Lee, Min-Young;Yoon, Young-Bong;Shin, Won-Geun
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.4
    • /
    • pp.277-283
    • /
    • 2007
  • Since the Kyoto Protocol became into effect, Korea has been expected to be part of the Annex I countries performing the duty of GHG reduction in the phase of post-Kyoto. Therefore, it is necessary to develop emission factors appropriate to Korean circumstances. In order to develop emission factors this study utilized the CleanSYS, which is the real-time monitoring system for industrial smoke stacks to calculate the emission rate of $CO_2$ continuously. In this study, the main focus was on the power generation plants emitting the largest amount of $CO_2$ among the sectors of fossil fuel combustion. Also, an examination on the comparison of $CO_2$ emission was made among 3 generation plants using the different types of fuels such as bituminous coal and LNG; one for coal and others for LNG. The $CO_2$ concentration of the coal fired plant showed Ave. 13.85 %(10,384 ton/day). The LNG fired plants showed 3.16 %(1,031 ton/day) and 3.19 %(1,209 ton/day), respectably. Consequently, by calculating the emission factors using the above results, it was found that the bituminous coal fired power plant had the $CO_2$ emission factor average of 88,726 kg/TJ, and the LNG fired power plants had the $CO_2$ average emission factors of 56,971 kg/TJ and 55,012 kg/TJ respectably which were similar to the IPCC emission factor.

The Accident Hazard and Properties of the Leakage Current on the Electrical Insulation by Pollution (전기 절연물의 오염에 따른 누설전류 특성 및 사고위험성 연구)

  • Kim, Young-Seok;Shong, Kil-Mok;Jung, Jin-Su;Jung, Jong-Wook;Kim, Sun-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.463-467
    • /
    • 2007
  • It is necessary to study the prevention and the management of electrical facilities because the electrical fault took place at the dust occurrence area due to environmental pollution. In particular, the dust accumulates easily on insulation material which is exposed an external long time. The leakage current brings out electrical fault after all. Also, it is need to variation of material and shape to repress a leakage current on electrical material. In this paper, we measured a leakage current on electrical material of facilities by dust, and in experiments the prevention to electrical fault was studied.

  • PDF

A Study on the Early-stage Storm Runoff Treatment for the Reduction of Non-point Pollution Materials on the Road (도로상의 비점오염물질 저감을 위한 초기 우수유출수 처리에 관한 연구)

  • Roh, Sung-Duk;Lee, Dae-Keun;Chun, Yang-Kun
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.525-533
    • /
    • 2004
  • The object ofthis study was to test for STORMSYS process that composed Catch Basin and Stormsys(three units: vortex solids separator, filter media bed and vegetated filter strips). It could be applied to treat the first-flush non-point pollution materials on the road(especially, motorway). This study investigated that the runoff characteristics of non-point pollutions containing the heavy metal(Fe, Zn and Cu) by rainfall showed relatively high pollution concentration in the early-stage storm runoff on the road, which seems to be caused by the vehicular traffic, and showed the rapid reduction of pollution concentration on the basis of about 5mm rainfall volume. As the number of the non-rainy days were increased, the pollution concentration by storm runoff was increased, also. As a test result of this process, the average removal efficiency of BOD, $COD_{mn}$, SS, T-N and T-P over the testing period were 92.7%,88.6%,97.4%,93.0% and 93.3%, respectively. Also, the average removal efficiency of n-Hexane, Fe, Zn and Cu were 86.7%, 96.1%, 84.4% and 78.4%, respectively. As shown in the characteristics of storm runoff, the non-point pollution materials have high pollution concentration in the early-stage storm runoff on the road, the installation of STORMSYS process is expected to reduce considerable amount of non-point pollutions.

Improvement Method of Hazardous Materials Facilities Installation License of Manufacturer (위험물시설의 설치허가제도의 개선방안)

  • 이종영;이수경;김태환
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.21-35
    • /
    • 2001
  • By rearing private experts to design hazardous facilities, Safety property is obstained. So it is necessary to limit within the designer of hazardous materials facilities who has some degree skill. After permission progress about the inspection of the design ascertain whether it is safety property Mayor/Do governor permits within the laws and their qualification. Accordingly, Korea Fire Equipment Inspection Corporation be come specialization about the design, inspection of construction completion. A inquire purpose of Fire Service Act be considered fitness. Subject by which the Korea Fire Equipment Inspection Corporation is entrusted, subject by which the a non-probit corporation in The Civil Law be possible to entrusted in separate. In this case, because of the level of one's technique and facilities are important, to limit as a nonprobit corporation in The Civil Law give rise to trouble. Consequently; established a business corporation, which the level of one's technique and facilities, in accordance with The Commercial Law can assign inspection of construction completion. The contents of the Fire Services Act is caused by the historic growth of hazardous facilities's safety management. Because we decide on a course about completed inspection of hazardous substance, it is needed that adjust the task performed by a corporation of the exert skill and the duty performed by the task that a authorized corporation on the civil law or the commercial law To adjust the duty, the Fire Service Act, that is suitable to the purpose and principle, should constitute a measure of the duty. With the object of insure the safety of the hazardous substance, when the fire survice act establish a corporation of the expert skill. There is the will of lawmakers that need organization to have the power of the professional technology. The state excise the will that insure the safety of hazardous materials facilities on the basis of the professional technology and facilities, and construct to establish a corporation of the expert skill. Therefore as concentrate on the technology to need to insure the safety of the facilities of hazardous substance to be suitable on the purpose of laws and take responsibility and reports to a corporation of the expert skill. The task to be given to the state will be done.

  • PDF

Legislative and policy issues related to the advancement of the maintenance system of water resource facilities (수자원시설물의 유지관리 체계 선진화를 위한 입법 및 정책과제)

  • Lee, Giha;Yeon, Minho;Lee, Daeeop;Kim, Seongwon;Kim, Jinsoo
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.spc1
    • /
    • pp.773-784
    • /
    • 2020
  • In this study, legislative and policy issues related to advancing the maintenance system of water resource facilities were presented by investigating and analyzing the degree of aging and management status of water resource facilities. Data from the comprehensive Facility Management System (FMS) operated by the Korea Infrastructure Safety Corporation were collected and used to analyze the aging of water resource facilities. Using safety grade data categorized by facility, type, local area, and grade, the ratio of dangerous facilities and the aging rate were calculated to analyze the status of water resource facilities and guidelines and manuals related to water resource facilities were investigated. Through this, four required actions to address legislative and policy issues were presented: 1) Readjusting the scope of water resource facilities and supplementing guidelines and manuals, 2) Establishing a maintenance system considering changes in disaster conditions, 3) Improving the FMS and activating standard linkage services, and 4) Establishing a facility asset management system.

A Study on Surveying Functions of RBI Software (RBI 소프트웨어의 기능에 관한 조사연구)

  • Song J S;Shim S H;No W H;Park J H;Choi S C;Kwon J R;Kim J Y;Yoon K B
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.56-61
    • /
    • 2001
  • Recently RBI softwares have received widespread interests from various industries. The available RBI softwares have variety of levels of analysis, fields of applications and damage mechanisms considered, which depend on the software developing institutes. In this paper results of a GSP(Group Sponsored Project) entitled 'Study on Surveying Functions of Foreign RBI Softwares' are summarized. A part of the study is explained in detail as a sample case for showing the contents of the project. Based on the demo softwares as well as the open documents and contents obtained in the web pages of the developer critical comparisons of the well-known RBI softwares were made. The required functions of the optimal RBI software is also discussed from the review results of this study.

  • PDF

Developing Mobile Safety Management System for City-Gas Supply Facilities (도시가스 공급시설을 위한 모바일 안전관리 시스템 개발)

  • Oh, Jeong-Seok;Sung, Jong-Gyu;Park, Jang-Sik;Kim, Ji-Yoon
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.1-7
    • /
    • 2011
  • The Measurement of risk parameter in city-gas equipments have been measured and confirmed by human, and evolved into remote monitoring system using wireless communication. Furthermore, domestic and international industry increase the efficiency of management, which can develop remote monitoring and control system using wireless communication. However, Those wireless system might be decrease the efficiency and ease because of connecting PDA and lap-top using wire-cable when data have checked immediately from outside. This paper is able to improve efficiency of safety management on city-gas equipments by developing mobile city-gas safety management system on AR.

A Safety Management Strategy for Temporary LP-gas Facilities (이동형 LP가스 사용시설의 안전관리 방안)

  • Lee, Duk-Gwon;Lee, Seung-Kuk;Lee, Yeon-Jae;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.73-79
    • /
    • 2016
  • A temporary LP-gas facility means outdoor LP-gas facilities in public venues such as boothes or food stalls. As temporary LP-gas facility is not an object of mandatory inspection, it is neccesary to develop an effective strategy of safety management. In this study, the direction of safety management strategy is analyzed through a survey and analysis of risk factor about gas facilities in a booth and stall. Some improved directions are suggested such as the use of pipeline and common gas storage. It is expected that the results of this study could help to improve LP-gas efficiency management.