• 제목/요약/키워드: Facet strain

검색결과 7건 처리시간 0.026초

Biomechanical Study of Lumbar Spinal Arthroplasty with a Semi-Constrained Artificial Disc (Activ L) in the Human Cadaveric Spine

  • Ha, Sung-Kon;Kim, Se-Hoon;Kim, Daniel H.;Park, Jung-Yul;Lim, Dong-Jun;Lee, Sang-Kook
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권3호
    • /
    • pp.169-175
    • /
    • 2009
  • Objective : The goal of this study was to evaluate the biomechanical features of human cadaveric spines implanted with the Activ L prosthesis. Methods : Five cadaveric human lumbosacral spines (L2-S2) were tested for different motion modes, i.e. extension and flexion, right and left lateral bending and rotation. Baseline measurements of the range of motion (ROM), disc pressure (DP), and facet strain (FS) were performed in six modes of motion by applying loads up to 8 Nm, with a loading rate of 0.3 Nm/second. A constant 400 N axial follower preload was applied throughout the loading. After the Activ L was implanted at the L4-L5 disc space, measurements were repeated in the same manner. Results : The Activ L arthroplasty showed statistically significant decrease of ROM during rotation, increase of ROM during flexion and lateral bending at the operative segment and increase of ROM at the inferior segment during flexion. The DP of the superior disc of the operative site was comparable to those of intact spine and the DP of the inferior disc decreased in all motion modes, but these were not statistically significant. For FS, statistically significant decrease was detected at the operative facet during flexion and at the inferior facet during rotation. Conclusion : In vitro physiologic preload setting, the Activ L arthroplasty showed less restoration of ROM at the operative and adjacent levels as compared with intact spine. However, results of this study revealed that there are several possible theoretical useful results to reduce the incidence of adjacent segment disease.

The First-principles View of Nanometal Alloy Catalysts

  • Ham, Hyung Chul;Hwang, Gyeong S.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.129-129
    • /
    • 2013
  • Nanometal alloy catalysts have been found to significantly increase catalytic efficiency, compared to the monometallic counterparts. This enhancement can be attributed to various alloying effects: i) the existence of uniquemixed-metal surface sites [the so called ensemble (geometric) effect]; ii) electronic state changes due to metal-metal interactions [the so called ligand (electronic) effect]; and iii) strain caused by lattice mismatch between the alloy components [the socalled strain effect]. In addition, the presence of low-coordination surface atoms and preferential exposure of specific facets [(111), (100), (110)] in association with the size and shape of nanoparticle catalysts [the so called shape-size-facet effect] can be another important factor for modifying the catalytic activity. However, mechanisms underlying the alloying effect still remain unclear owing to the difficulty of direct characterization. Computational approaches, particularly the prediction using first-principles density functional theory (DFT), can be a powerful and flexible alternative for unraveling the role of alloying effects in catalysis since those can give us quantitative insights into the catalytic systems. In this talk, I will present the underlying principles (such as atomic arrangement, facet, local strain, ligand interaction, and effective atomic coordination number at the surface) that govern catalytic reactions occurring on Pd-based alloys using the first-principles calculations. This work highlights the importance of knowing how to properly tailor the surface reactivity of alloy catalysts for achieving high catalytic performance.

  • PDF

다축응력상태에서의 304 스테인리스강의 고온 파괴수명에 관한 연구 (High temperature rupture lifetime of 304 stainless steel under multiaxial stress states)

  • 김호경;정강;정진성
    • 대한기계학회논문집A
    • /
    • 제22권3호
    • /
    • pp.595-602
    • /
    • 1998
  • Specimens of 304 stainless steel were tested to failure at elevated temperatures under multiaxial stress states, uniaxial tension using smooth bar specimens, biaxial shearing using double shear bar specimens, and triaxial tension using notched bar specimens. Rupture times are compared for uniaxial, biaxial, and triaxial stress states with respect to the maximum principal stress, the von Mises effective stress, and the principal facet stress. The results indicate that the principal facet stress gives the best correlation for the material investigated, and this parameter can predict creep life data under multiaxial stress states with rupture data obtained with specimens under uniaxial stresses. The results also suggest that grain boundary cavitation, coupled with localized deformation processes such as grain boudary sliding, controls the lifetimes of the specimens.

High-Temperature Rupture of 5083-Al Alloy under Multiaxial Stress States

  • Kim Ho-Kyung;Chun Duk-Kyu;Kim Sung- Hoon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권7호
    • /
    • pp.1432-1440
    • /
    • 2005
  • High-temperature rupture behavior of 5083-Al alloy was tested for failure at 548K under multiaxial stress conditions: uniaxial tension using smooth bar specimens, biaxial shearing using double shear bar specimens, and triaxial tension using notched bar specimens. Rupture times were compared for uniaxial, biaxial, and triaxial stress conditions with respect to the maximum principal stress, the von Mises effective stress, and the principal facet stress. The results indicate that the von Mises effective and principal facet stresses give good correlation for the material investigated, and these parameters can predict creep life data under the multiaxial stress states with the rupture data obtained from specimens under the uniaxial stress. The results suggest that the creep rupture of this alloy under the testing condition is controlled by cavitation coupled with highly localized deformation process, such as grain boundary sliding. It is also conceivable that strain softening controls the highly localized deformation modes which result in cavitation damage in controlling rupture time of this alloy.

인공추간판 적용 시 인접 운동 분절에서의 변화 분석 (Analysis of biomechanical change of adjacent motion segment of the lumbar spine with an implanted artificial disc)

  • 김영은;윤상석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.244-247
    • /
    • 2005
  • Although several artificial disc designs have been developed for the treatment of discogenic low back pain and used clinically, biomechanical change with its implantation seldom studied. To evaluate the effect of artificial disc implantation on the biomechanics of lumbar spinal unit, nonlinear three-dimensional finite element model of L1-L5, S1 was developed and strain and stress of vertebral body and surrounding spinal ligaments were predicted. Intact osteoligamentous L1-L5, S1 model was created with 1-mm CT scan of a volunteer and known material property of each element were applied. This model also includes the effect of local muscles which was modeled with pre-strained spring elements. The intact model was validated with reported biomechanical data. Two models implanted with artificial discs, SB Charite or Prodisc, at L4/5 via anterior approach were also developed. The implanted model predictions were compared with that of intact model. Angular motion of vertebral body, force on spinal ligaments, facet joint contact force with $2\sim12$ Nm flexion-extension moment.

  • PDF

부분 장골과 장요추 인대를 포함한 요추 천추골의 유한 요소 모델링 및 비선형 해석 (Finite Element Modeling and Nonlinear Analysis of Lumbosacrum Including Partial Ilium and Iliolumbar Ligaments)

  • 하성규;임종완
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권3호
    • /
    • pp.397-409
    • /
    • 2007
  • Owing to needs of biomechanical comprehension and analysis to obtain various medical treatment designs which are related with the spine in order to cure and diagnose LBP patients, the FE modeling and nonlinear analysis of lumbosacrum including a partial ilium and iliolumbar ligaments, were carried out. First, we investigated whether the geometrical configuration of vertebrae displayed by DICOM slice files is regular and normal condition. After constructing spinal vertebrae including a partial ilium, a sacrum and five lumbars (from L1 to L5)with anatomical shape reconstructed using softwares such as image modeler and CAD modeler, we added iliolumbar ligaments, lumbar ligaments, discs and facet joints, etc.. And also, we assigned material property and discretized the model using proper finite element types, thus it was completely modeled through the above procedure. For the verification of each segment, average sagittal ROM, average coronal ROM and average transversal ROM under various loading conditions(${\pm}10Nm$), average vertical displacement under compression(400N), ALL(Anterior Longitudinal Ligament) and PLL(Posterior Longitudinal Ligament) force at L12 level, strains of seven ligaments on sagittal plane at L45 level and maximal strain of disc fibers according to various loading conditions at L45 level, etc., they were compared with experimental results. For the verification of multilevel-lumbosacrum spine including partial ilium and iliolumbar ligaments, the cases with and without iliolumbar ligaments were compared with ROM of experiment. The results were obtained from analysis of the verified FE model as follows: I) Iliolumbar ligaments played a stabilizing role as mainly posterior iliolumbar ligaments under flexion and as both posterior and anterior iliolumbar ligaments of one side under lateral bending. 2) The iliolumbar ligaments decreased total ROM of 1-8% in total model according to various motion conditions, which changed facet contact forces of L5S level by approximately 0.8-1.4 times and disc forces of L5S level by approximately 0.8-1.5 times more than casewithout ilioligaments, under various loading conditions. 3) The force of lower discs such as L45 and L5S was bigger than upper discs under flexion, left and right bending and left and right twisting, except extension. 4) It was predicted that strains of posterior ligaments among iliolumbar ligaments would produce the maximum 16% under flexion and the maximum 10% under twisting. 5) It's expected that this present model applies to the development and design of artificial disc, since it was comparatively in agreement with the experimental datum.

GaN 스트라이프 꼭대기 위의 AlGaN 어레이 미세구조의 선택적 결정 성장 (Selective area growth of micro-sized AlGaN array structures on GaN stripes)

  • 이승현;안형수;양민
    • 한국결정성장학회지
    • /
    • 제25권5호
    • /
    • pp.182-187
    • /
    • 2015
  • GaN 스트라이프 구조의 정상 부분에 Metal Organic Chemical Vapor Deposition(MOCVD) 방법에 의해 선택적으로 결정 성장된 마이크로 크기의 AlGaN 어레이 구조의 성장과 그 특성에 관해 연구하였다. AlGaN 어레이 구조의 형태 변화가 선택 성장을 위한 노출 면적에 의존한다는 것을 확인하였다. 상대적으로 넓게 노출 된 성장 영역 위에서 선택 성장된 AlGaN 어레이 구조는 기판 위의 GaN 스트라이프와 유사한 규칙적인 모양을 가지는 반면 상대적으로 좁게 노출된 영역 위에서 선택 성장 된 AlGaN 어레이 구조는 불규칙한 모양을 가진다. 한편, Al 조성비가 증가함에 따라 AlGaN 어레이 미세 구조에 대한 고유 포논 진동수도 높아짐을 확인할 수 있었다. 하지만 상대적으로 높은 Al 조성비에서는 고유 포논 진동수는 AlGaN 구조와 그 아래의 GaN 스트라이프 사이의 큰 격자상수 차이와 선택적 결정 성장 과정 동안의 결정면 방향의 변화에 의해 강한 tensile strain으로 인해 다시 감소하는 경향을 보임을 확인하였다.