• Title/Summary/Keyword: Face cooling

Search Result 76, Processing Time 0.031 seconds

Modeling of the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners using Accelerated Particle-Loading System (파울링 가속장치를 이용한 공기조화기용 열교환기의 공기측 파울링 특성에 대한 예측 모델링)

  • Ahn Young-Chull;Lee Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.3
    • /
    • pp.262-267
    • /
    • 2005
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate and to model the air-side particulate fouling characteristics of the heat exchangers using accelerated particle loading system. The main variables of the modeling equation are face velocity and dust concentration. The modeling equation shows good agreements with the experimental results at the face velocity of 0.5, 1.0, 1.5 m/s and the dust concentration of 1.28 and $3.84\;g/m^3$. It will be very useful to predict fouling characteristics such as variations of pressure drop and heat transfer capacity in finned-tube heat exchangers of air conditioners.

The Moisturizing and Cooling Effects of the Cosmetic Products Containing Scrophulariae Radix, Poria, Lonicerae Flos, Portulacea Herba and Ginko Folium Extract on Human Skin (현삼(玄蔘), 백봉령(白茯岺), 금은화(金銀花), 마치현, 백과엽(白果葉)을 함유하는 한방화장품이 인체 피부의 보습 및 청열 효능에 미치는 영향)

  • Kim, Seung-Hun;Kim, Eun-Joo;Kim, Jee-Eun;Nam, Hye-Seong;Kim, Youn-Joon;Chung, Hyun-Mi;Nam, Gae-Won;An, Sung-Yeon;Lee, Hae-Kwang;Moon, Seong-Joon;Yang, Woong-Mo;Chang, Mun-Seog;Park, Seong-Kyu
    • The Korea Journal of Herbology
    • /
    • v.22 no.2
    • /
    • pp.45-50
    • /
    • 2007
  • objectives: We investigated the moisturizing and cooling effects of the cosmetic product with Scrophularia Buergeriana, Poria Cocos, Lonicera Japonica, Portulaca Oleracea and Ginko Biloba extract on human skin by using non-invasive instrument. Methods: We measured physiological effects after volunteers(female, n=5) applied the cosmetic product containing the extract of oriental herbs. The forearm skin moisturization was measured with $Corneometer^{\circledR}$ CM825 after 15min, 3hr, and 6hr. The forearm skin surface roughness was with Scanning electron microscopy after 15min, and 6hr. The face skin temperatures cooling and microcirculation effects were measured with ThermaCAMTM PM525 and LDl-Periscan PlM II after 15min, and 30min. Results: The forearm skin moisturization was imcreased 108% after 15min. The forearm skin surface roughness was decreased significantly after 15min. The face skin temperatures were cooling down to $30.7^{\circ}C$. The face skin microcirculation effect was normalized time-dependently. Conclusions: We concluded that cosmetic product containing the extract of Scrophularia Buergeriana, Poria Cocos, Lonicera Japonica, Portulaca Oleracea and Ginko Biloba had a moisturization effect and improving the surface roughness, temperature and microcirculation on the human skin.

  • PDF

Cooling Energy Saving System using Solar Heat Protection Dvices (일사차단용 설비를 이용한 냉방 에너지 절약 방안)

  • Jeong, Ky-Bum;Choi, Sang-Gon
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.108-115
    • /
    • 2010
  • Global warming and heat island make the outdoor air temperature ascend. Tall office buildings are covered with glass window facades as a design aspect and the portion of window area to facade area is increasing. Hence, cooling load for solar radiation passing through glass window is rising. Cooling air to a certain room is supplied equally despite the face of the room in most office buildings. Especially, the west part of the office cannot maintain the required temperature that occupant needs because of the solar heat coming through windows.?In this study, we projected the water spray system to reduce the solar heat transfer and to reflect the solar ray through windows. We perform the experiments to evaluate the performance of the solar heat protection devices. We measured the room temperature of two separated office rooms for solar heat control devices. The investigation's results show that the water spray system is sufficient to the coated glass and the venetian blinds for the decrease of the solar heat inflow.

Strength Experimets on Head and Cooling Channel Specimens of a Preburner (예연소기 헤드 및 냉각채널 시편 강도 시험)

  • Yoo, Jae-Han;Moon, In-Sang;Lee, Soo-Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.2
    • /
    • pp.50-55
    • /
    • 2011
  • A preburner for the high performance, staged combustion cycle liquid rocket engine is being developed. For the structural design processes, strength experiments and finite element analyses on specimens simulating the brazing joints of the preburner, were performed and compared. Total two kinds of the specimen were manufactured for the tests. One simulated the joints between the oxygen injectors and the head junctioned by the conventional vacuum brazing. The another was made to test the brazing surfaces by vacuum compression between the combustion chamber cooling channel and the outer wall. During the burst experiments, it was observed that the fractures were occurred not at the brazed joining but in the middle of the face plate and the cooling wall. In addition, the analysis showed that the predicted fracture locations and the strains were well matched with the experiment results.

A review on the risk, prevention and control of cooling water intake blockage in coastal nuclear power plants

  • Heshan Lin;Shuyi Zhang;Ranran Cao;Shihao Yu;Wei Bai;Rongyong Zhang;Jia Yang;Li Dai;Jianxin Chen;Yu Zhang;Hongni Xu;Kun Liu;Xinke Zhang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.389-401
    • /
    • 2024
  • In recent decades, numerous instances of blockages have been reported in coastal nuclear power plants globally, leading to serious safety accidents such as power reduction, manual or automatic power loss, or shutdown of nuclear power units. Loss or shortage of cooling water may compromise the reliability of the cooling water system, thus threatening the operational safety of power plants and resulting in revenue reduction. This study provides a comprehensive review of the current state of cooling water system safety in coastal nuclear power plants worldwide and the common challenges they face, as well as the relevant research on cooling water system safety issues. The research overview and progress in investigation methods, outbreak mechanisms, prevention and control measures, and practical cases of blockages were summarized. Despite existing research, there are still many shortcomings regarding the pertinence, comprehensiveness and prospects of related research, and many problems urgently need to be solved. The most fundamental concern involves understanding the list of potential risks of blockages and their spatially distributed effects in surrounding waters. Furthermore, knowledge of the biological cycles and ecological habits of key organisms is essential for implementing risk prevention and control and for building a scientific and effective monitoring system.

A Study on the Characteristics of Martensitic Transformation Behaviors in In-X(X=Pb,Sn) Alloys (In-X(X=Pb,Sn) 합금의 마르텐사이트변태거동 특성에 관한 연구)

  • Han, Chang-Suk;Han, Seung-Oh
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.5
    • /
    • pp.233-238
    • /
    • 2010
  • The phase transformations and the shape memory effect in In-rich Pb alloys and In rich-Sn alloys have been studied by means of X-ray diffractometry supplemented by metallographic observations. The alloys containing 12~15 at.%Pb transform from the ${\alpha}_2$ (fct) phase to the ${\alpha}_1$ (fct) phase by way of an intermediate phase (m phase) on cooling. The results of X-ray diffraction show that the metastable intermediate phase is observed both on cooling and heating, and has a face-centered orthorhombic (fco) structure. It is concluded that the ${\alpha}_1{\rightleftarrows}{\alpha}_2$ transformation is expressed by the ${\alpha}_1{\rightleftarrows}m{\rightleftarrows}{\alpha}_2$ transformation both on usual cooling and heating with the rate more than $8{\times}10^{-3}$ K/s. The $m{\rightleftarrows}{\alpha}_2$ transformation takes place with a mechanism involving macroscopic shear and are of diffusionless (martensitic) type. The temperature hysteresis in the two transformations is 10~13 K between the heating and cooling transformations. The alloys containing 0~11 at.%Sn are -phase solid solutions with a face centered tetragonal structure (c/a > 1) at room temperature, the axial ratio increasing continuously with tin content. The In-(11~15) at.%Sn alloys are mixtures of ${\alpha}$ and ${\beta}$ phases, the ${\beta}$ phase having a f. c. tetragonal structure (c/a < 1). The alloys containing more than 15 at.%Sn are ${\beta}$-phase solid solutions. The In-(12.9~15.0) at.%Sn alloys show a shape memory effect only when quenched to the temperature of liquid nitrogen, although their effect becomes weak and finally disappears after keeping at room temperature for a long time. The ${\beta}{\rightarrow}{\alpha}^{\prime}$ phase transformation is of the diffusionless (martensitic) type, and takes place between 330 K at 12.9 at.%Sn and 150 K at 14.5 at.%Sn. The hysteresis of transformation temperatures on heating and cooling is considerably large (29~40 K), depending on the composition. Both In-Pb and In-Sn alloys showed distinct the shape memory effects.

Numerical Analysis on 3-dimensional Heat transfer of Heating Surface with Periodically Arrayed Injectors (분사기가 주기적으로 배열된 가열면의 3차원 열전달 수치해석 연구)

  • Cho, Won-Kook;Kim, Young-Mog
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.8
    • /
    • pp.112-119
    • /
    • 2002
  • Three dimensional numerical heat transfer analysis was carried out against periodically arranged fuel injectors of the liquid rocket engine. A finite volume method based on SIMPLE algorithm was adapted which gave a good agreement with the published results of the heat transfer problem of a backward facing step. The Nusselt number and pressure drop increased as the distance between the injector elements decreased. When the Reynolds number increased, the Nusselt number increased but nondimensionalized pressure drop decreased slightly.

Window-to-Wall-Ratio for Energy Reduction in Early Design Stage of Residential Building

  • Lee, Myung Sik
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.89-94
    • /
    • 2017
  • In Korea, it is necessary to improve the performance of buildings with respect to the energy efficiency while improving the quality of occupants' lives through a sustainable built environment. During the design and development process, building projects must have a comprehensive, integrated perspective that seeks to reduce heating, cooling and lighting loads through climate-responsive designs. The aim of this study is to assess the optimal window-to-wall ratio of multi-rise residential units in the early design phase in Korea. The study analyzed the variation of annual heating and cooling energy load in two apartment prototype units located in Seoul city using different WWRs. The analysis was conducted using Autodesk Ecotect Analysis 2011 tool. The study found for total annual building load reductions WWR on the south and north face should be studied independently based on the room function. It also found reducing the WWR for bedrooms and windows on the northern façade resulted in reduced total annual building load.

Cooling Geometry Dependent Operation Properties in a Diode End-Pumped Monolithic Yb:YAG Laser

  • Moon, Hee-Jong;Lim, Changhwan
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.593-600
    • /
    • 2016
  • Operation properties, such as output power, beam radius, and crystal temperature rise were investigated in a diode-pumped edge-cooled monolithic Yb:YAG laser with ~ 4 W pumping level. The output power showed saturation behavior because of severe temperature rise and poor spatial overlapping between pump beam and lasing mode. Face cooling geometry by using a sapphire plate was also investigated. No apparent saturation behavior in output power was observed due to the reduced temperature rise, which could be attributed to efficient heat removal through the crystal-sapphire interface.

Thermal Analysis of Continuous Casting Welding-Coated Mold (용접코팅된 연속주조 몰드의 열해석)

  • 이종선;김세환
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.1
    • /
    • pp.7-12
    • /
    • 2001
  • This study is object to thermal analysis of continuous casting welding-coated mold. A two-dimen-sional transient finite element model was developed to compute the temperature distribution for continuous casting welding-coated mold. For thermal analysis using analysis result from FEM code. This thermal analysis results, many variables such as casting speed, cooling condition, film coefficient, convection and load condition are considered.

  • PDF