• Title/Summary/Keyword: Facade Variation

Search Result 17, Processing Time 0.035 seconds

Planning the Blind Position Considering Thermal Performance in the Intermediate Space of Double-Skin Facade (이중외피 중공층의 열성능을 고려한 블라인드 위치 계획)

  • Choi Dong-Hee;Jo Jae-Hun;Seok Ho-Tae;Yeo Myoung-Souk;Kim Kwang-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.620-628
    • /
    • 2005
  • The blinds in the intermediate space are installed to block the direct solar radiation. As the blind divide the airflow of intermediate space into two, thermal performance of Double-Skin Facade (DSF) are affected by the blind position. Therefore blind position should be planed with careful consideration in order to maximize the thermal performance of DSF. In this study, CFD was peformed to analyze the effect of blind position in multistory-type DSF in variation of other DSF elements. The simulation results showed that the case with narrow depth of intermediate space and outlet on upper side of outer-facade, it is profitable to place blind as close as possible to the outer-facade. In the other cases, the blind should maintain 0.15 m distance from outer-facade.

Planning of the Blind Position Considering Thermal Performance in the Intermediate Space of Double-Skin Facade

  • Choi Dong-Hee;Jo Jae-Hun;Seok Ho-Tae;Yeo Myoung-Souk;Kim Kwang-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.2
    • /
    • pp.57-65
    • /
    • 2006
  • The blinds in the intermediate space are installed to block the direct solar radiation. As the blind divides the airflow of intermediate space into two parts, thermal performance of Double-Skin Facade(DSF) is affected by the blind position. Therefore the blind position should be planned with careful consideration in order to maximize the thermal performance of DSF. In this study, CFD was performed to analyze the effect of blind position in multistory-type DSF in variation of other DSF elements. The simulation results showed that the case with narrow depth of intermediate space and outlet on upper side of outer-facade, it is profitable to place blind as close as possible to the outer facade. In the other cases, the blind should maintain 0.15m distance from outer facade.

Performance Assessment of Building Envelopes I: Double Skin Facade (외피 친환경 성능평가 I: 이중외피)

  • Kim, Deuk-Woo;Park, Cheol-Soo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.77-82
    • /
    • 2009
  • Many countries have been interested in sustainable development of buildings for environmental preservation. Thus it is significant to assess building envelopes in terms of $CO_2$ emissions owing to Kyoto Protocol. In this paper, a Double Skin Facade(DSF) installed in a general office building was assessed by $CO_2$ emissions(one of the performance-based assessment). To predict $CO_2$ emissions caused by the building energy consumption, the dynamic simulation program(Energy Plus) and $CO_2$ emission factor was used. Because DSF has various airflow regimes, pre-simulation runs were conducted to decide proximate optimal airflow regimes depending on seasonal variation. It is shown that the DSF can achieve 17.1-36.5% of annual energy savings.

  • PDF

A Study on the Cavity Height of Muti-Story Double-Skin Facade for better Thermal Performance (열성능을 고려한 다층형 이중외피의 중공층 높이에 관한 연구)

  • Shin, Seon-Joon;Jo, Jae-Hun;Seok, Ho-Tae;Kim, Kwang-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.53-62
    • /
    • 2005
  • In this study, the thermal performance of multi-story double-skin facade(DSF) with variation of cavity height is evaluated to offer useful data in determining cavity height of multi-story DSF. For this, thermal criteria for multi-story DSF is adopted and a DSF model for evaluation of the thermal performance is established. Through the evaluation of CFD simulation, the recommended height of multi-story DSF is 5 stories or less to improve the thermal performance during the intermediate season.

The Analysis on the Variation of the Ventilation Rates by Wind Pressure and Temperature Difference between Indoor and Outdoor in the Multi-Story Type Double Skin Facade applied to the Office Building (오피스 건물에 적용된 다층형 이중외피의 풍압과 실내·외 온도차에 의한 환기량 변화 분석)

  • Song, Chi-Ho;Kim, Teayeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.123-131
    • /
    • 2015
  • Purpose : Improvement of indoor thermal comfort and reduction of the energy consumption in building can be obtained by applying a double skin facade system. In order to achieve effectively this purpose, design team would have to perform easy and appropriate performance analysis for making better design decision during the design process. Method : This paper focus on the natural ventilation performance of a multi-story type double skin facade with main causes which are pressure difference according to the wind and temperature difference between indoor and outdoor (Buoyancy Effect). Using this main causes, the natural ventilation ratio of wind effect-to-buoyancy effect in cavity of multi-story type double skin facade were analyzed through the performance analysis results of CFD (Computational Fluid Dynamics) simulation. Result : When the wind velocity was 2m/s, the ventilation rate in the cavity was highest. If wind velocity was slower than 2m/s wind velocity, buoyancy effect has more influence on the ventilation rate in the cavity, and if wind velocity was faster than 2m/s wind velocity, wind effect has more influence on the ventilation rate in the cavity.

A Comparative Experimental Study on Thermal Performance of Box-typed Double Skin and Curtain Wall in Cooling Period (박스형 이중외피와 커튼월의 냉방기 열적성능에 관한 비교실험 연구)

  • Park, Chang-Young;Lee, Keon-Ho;Yoon, Yong-Sang;Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.111-119
    • /
    • 2007
  • The annual mean temperature of South Korea has risen by $1.3^{\circ}C$ for last 100 years by urbanization and industrialization. Especially, the frequency of unusual hot weather in summer increases for a long time and the frequency of unusual cold weather in winter clearly decreases. In recently, The considerable portion of curtain wall system is appled to building skin in domestic. As related to this, the Korea Institute of Construction Technology devised the box typed double skin facade(It is occasionally called as FDFS : Functional Double Facade System) as an alternative that reflects the distinctive local climate and saves cooling energy. Two mock-ups($49m^*4.9m$) applied to single skin(curtain wall) and double skin each were monitored under the outdoor condition. Therefore, the characteristics of natural ventilation and cooling energy consumption of each window had been analyzed in real time. The results of this study are summarized as follow, Analysis of the experiment on an air conditioner: the indoor temperature of the chamber with FDFS is lower than that of the chamber with single skin facades by $3{\sim}6$ degrees(C). A temperature variation of about $1{\sim}2$ degrees between the 0.2m and 1.7m height of the mock-up occurs in FDFS, while that of about maximum 7 degrees occurs in single skin facade at noon with abundant intensity of solar accident. Also, 67 percent of energy consumption for air conditioning has been saved.

Study on variation of electrical characteristics of vertical PV module according to the change of irradiance and temperature (수직형 태양광발전모듈의 계절별 일사획득 및 온도변화에 따른 출력특성 변화에 관한 연구)

  • Park, Kyung-Eun;Kang, Gi-Hwan;Kim, Hyun-Il;Yu, Gwon-Jong;Kim, Jun-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.57-62
    • /
    • 2008
  • Building Integrated PV(BIPV) is one of the best fascinating PV application technologies. To apply PV module in building, various factors should be reflected such as installation position, shading, temperature, and so on. Especially the installation condition should be considered, for the generation performance of PV module is changed or the generation loss is appeared according to installation position, method, and etc. This study investigates variation of electrical characteristics of a PV module according to the change of irradiance and temperature. From this experimental study, we confirmed that the irradiance, the temperature variation and the generation performance of a PV module were appeared differently according seasonal variation. Actually the PV module installed in building facade showed high-generation performance in winter.

  • PDF

Wind Effects on Tall Buildings with a Porous Double-Skin Façade

  • Shengyu Tian;Cassandra Brigden;Caroline Kingsford;Gang Hu;Robert Ong;K.C.S. Kwok
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.4
    • /
    • pp.265-276
    • /
    • 2022
  • Double-Skin Facades (DSF) on tall buildings are becoming increasingly common in urban environments due to their ability to provide architectural merit, passive design, acoustic control and even improved structural efficiency. This study aims to understand the effects of porous DSF on the aerodynamic characteristics of tall buildings using wind tunnel tests. High Frequency Force Balance and pressure tests were performed on the CAARC standard tall building model with a variable porous DSF on the windward face. The introduction of a porous DSF did not adversely affect the overall mean forces and moments experienced by the building, with few differences compared to the standard tall building model. There was also minimal variation between the results for the three porosities tested: 50%, 65% and 80%. The presence of a full-height porous DSF was shown to effectively reduce the mean and fluctuating wind pressure on the side face of the building by about 10%, and a porous DSF over the lower half height of the building was almost as effective. This indicates that the porous DSF could be used to reduce the design load on cladding and fixtures on the side faces of tall buildings, where most damage to facades typically occurs.

Study on the size reduction factor of extreme wind pressure of facade cladding of high-rise buildings with square section

  • Xiang Wang;Yong Quan;Zhengwei Zhang;Ming Gu
    • Wind and Structures
    • /
    • v.36 no.1
    • /
    • pp.41-60
    • /
    • 2023
  • The effect of cladding panel size on the size reduction factor (SRF) of extreme area-averaging wind pressure (EAWP) on the facades of a high-rise building is often ignored in previous studies. Based on wind tunnel tests, this study investigated the horizontal and vertical correlations of wind pressure on the facade claddings of square-section high-rise buildings. Then, the influencing parameters on the SRF of the EAWP on the cladding panels were analyzed, which were the panel area, panel width, panel length and building width. The results show clear regional distinctions in the correlation of wind pressures on the building facades and the rules of the horizontal and vertical correlations are remarkably different, which causes the cladding size ratio to impact the SRF significantly. Therefore, this study suggests the use of the non-dimensional comprehensive size parameter b𝜶h1-𝜶/B (𝜶 is the fitting parameter) determined by the cladding panel horizontal size b, cladding panel vertical size h and the building width B rather than the cladding panel area to describe the variation of the EAWP. Finally, some empirical formula for the SRF of the EAWP on the cladding of a high-rise building is proposed with the nondimensional comprehensive size parameter.

Study on the Utilization of System Form By the Variation on Structure Elevation (구조물 입면 변화에 따른 시스템 거푸집 활용 방안 연구)

  • Lee, Yong-Sang
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.207-208
    • /
    • 2014
  • The construction of economic, efficient and stable process has been a major challenge as the building are getting high-rise and biger. Low-rise buildings widely have been used Euro-form in the past. Recently, we are mainly using Al-form which can respond to chang in the various structures. we should be used in combination with Al-form and Gang-form to ensure the quality and construction process, according to the change of various elevations. Recently construction project is reguired diversification of elevation. And we apply the open balcony on the general architecture as well as public housing. Accordingly, Al-form & Gang-form has been applied the change of elevation, We further apply design and construction as proposal of issues and alternatives.