Abstract
The blinds in the intermediate space are installed to block the direct solar radiation. As the blind divides the airflow of intermediate space into two parts, thermal performance of Double-Skin Facade(DSF) is affected by the blind position. Therefore the blind position should be planned with careful consideration in order to maximize the thermal performance of DSF. In this study, CFD was performed to analyze the effect of blind position in multistory-type DSF in variation of other DSF elements. The simulation results showed that the case with narrow depth of intermediate space and outlet on upper side of outer-facade, it is profitable to place blind as close as possible to the outer facade. In the other cases, the blind should maintain 0.15m distance from outer facade.
Keywords
Double-skin facade; Blind; Intermediate space; Thermal performance; Airflow; CFD;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Choi, D. H., 2004, A Study on the Influence of Blinds on Thermal Characteristics of Double-Skin Facade, Master's thesis, Seoul National University
2 Grabe, J., 2002, A prediction tool for the temperature field of double facades, Energy and Buildings, Vol. 34, pp. 891-899   DOI   ScienceOn
3 Urn, J. W., 2002, Evaluation of the Thermal Environment and Ventilation Performance for the Double Skin Building, Master's thesis, University of Seoul, Seoul, Korea
4 Oesterle, E., 2001, Double-Skin Facades, Prestel, New York
5 Jaros, M., 2002, Numerical and experimental investigation of the conditions in the double solar energy facade, Proceedings of the 10th International Conference on Indoor Air Quality and Climate-Indoor Air 2002, pp.1062-1067
6 Ove- Arup Consulting Engineers, 2003, Goyang City Culture Centre Study of Natural Ventilation by DSF, Schematic Design Report
7 Zollner, A., Winter, F. and Viskanta, R., 2002, Experimental studies of combined heat transfer in turbulent mixed convection fluid flows in double-skin-facades, International Journal of Heat and Mass Transfer, Vol. 45, pp.4401-4408   DOI   ScienceOn