• Title/Summary/Keyword: Facade Planning

Search Result 50, Processing Time 0.021 seconds

A Study on the Architectural Plan of the Pension by Modern People's Desire for Rural Life (전원생활에 대한 현대인의 욕구에 따른 펜션건축계획 연구)

  • Kim, Moon-Yeol;Park, Joon-Woong;Yeo, Joon-Ki;Choi, Moo-Hyuck
    • Journal of the Korean housing association
    • /
    • v.19 no.3
    • /
    • pp.49-58
    • /
    • 2008
  • This study focused on the architectural plan of the pension to meet modem people's desire for rural life, and the result of the study is as follows: First, the architectural plan for the characteristic of the location must apply the various architectural types considering the suburbs, tour and culture town, and community for the location improvement. Second, the architectural plan for the characteristic of the plot requires the encircled space and courtyard between buildings, the private gardens for the rooms, and the consideration of the surrounding environment. Above all, the plan for the subsidiary facilities is the most important. Third, the architectural plan for the characteristic of the plan requires the close connection with the outside, the wide opened view from the guest room, and the individual entrances for the guest rooms. Fourth, the architectural plan for the characteristic of the decorative design must consider the mass separation plan, the application of the facade design factors and eco-friendly environment materials, the night illumination plan, and the space program for the scenic view.

Analysis of Biophilic Design Elements in Exterior City Squares for a Application of Indoor Squares Design - Focused on Relaxation - (실내광장 적용을 위한 도시 광장의 바이오필릭 디자인(Biophilic Design) 요소분석 - 쉼(Relaxation)을 중심으로 -)

  • Park, Minjii;Lee, Hyunsoo
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.4
    • /
    • pp.3-12
    • /
    • 2016
  • The purpose of this study was to analyze City squares in Europe according to Biophilic Design elements to apply domestic Indoor Squares in Mixed-use building for relaxation. This study seeks to present a direction for designing an indoor square that uses the aspects of European city square. The following details consist the purpose of the study. First, Perspective from the Biophilic design and analyzing criteria of Europe city square. Second, European city square is analyzed to establish the criteria to be applied to indoor square. Third, based on European city square analysis, the planning direction for domestic indoor square is suggested. This result of paper proceeds as follows. First, it describes the analysis of the Indoor Squares of the domestic Mixed-use building. The results were derived of the fact that not applying the water elements and Facade greening. Second, In Europe Square, It is accounted for the highest proportion (33%) of the spaciousness. Third, Through a comparative analysis domestic indoor square was derived that the higher the need to improve the spaciousness and botanical motif. It is the ultimate goal of this study based on the analysis of the city square to set the criteria for the biophilic design of the indoor square to present the orientation of the indoor square.

Analysis on the Building System Integration Methods of the Salk Institute for Biological Studies (솔크 생물학 연구소에 적용된 건물시스템 통합기법 분석에 관한 연구)

  • Choi, Joon Sung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.7
    • /
    • pp.59-68
    • /
    • 2018
  • Salk Institute for Biological studies is widely considered as architectural masterpiece of Louis Kahn's. Its iconic plaza with symmetrical concrete structures, overlooking the Pacific ocean in La Jolla, has been acclaimed as a facade to the sky. Little has been written on Kahn's achievements in the building system integration in order to bridge the gap between technology and design. This paper explores the technical issues, the design intents, and the major building systems to identify the Kahn's integration methods between building systems. The project is analysed into four major systems; structure, mechanical, envelope, and interior system. The integration methods of building systems are investigated in physical, visual, and functional aspects. The most distinguished cases of building system integration are the introduction of the interstitial floors between the laboratories and the creation of the smooth and warm materiality of exposed concrete walls. Kahn proposed open floor plans for the laboratories which are capable of easily adapting to changing needs. He also introduced the interstitial floors which are framed of the vierendeel truss systems and deliberately overlapped the structure systems with the mechanical systems such as ducts, water pipes, and electric conduits. The exposed concrete walls mixed with pozzolan ashes look very much like granite or limestone as the result of the physical and visual integration between structure, envelope, and interior systems.

User-Participated Design Method for Perforated Metal Facades using Virtual Reality (가상현실 기반 사용자 참여형 타공패널 파사드 설계 방법론)

  • Jang, Do-Jin;Kim, Seongjun;Kim, Sung-Ah
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.4
    • /
    • pp.103-111
    • /
    • 2020
  • Perforated metal sheets are used as panels of facades for controlling environmental factors while ensuring user's visibility. Despite their functional potentials, only a specific direction of facades or an orientation of a building was considered in the relevant studies. This study proposed a design methodology for the perforated panel facades that reflects the location on the facades and the user's requirements. The optimization of quantitative and qualitative performance is achieved through communication between designers and users in a VR system. In optimizing quantitative performances, designers use machine learning techniques such as clustering and genetic algorithm to allocate optimal panels on the facades. In optimizing qualitative performances, through the VR system, users intervene in evaluating performances whose preferences are depending on them. The experiment using the office project showed that designers were able to make decisions based on clustering using GMM to optimize multiple quantitative performances. The gap between the target and final performance could be narrowed by limiting the types of perforated panels considering mass customization. In assessing visibility as a qualitative performance, users were able to participate in the design process using the VR system.

Motion Planning of Building Maintenance Robot System for Reducing Jerk Effect (빌트인형 BMR 시스템의 이동 중 충격완화를 위한 모션제어)

  • Lee, Seunghoon;Kang, Min-Sung;Kang, Sungpil;Hwang, Soonwoong;Kim, YoungSoo;Moon, Sung-Min;Hong, Daehie;Han, Chang-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.4
    • /
    • pp.368-374
    • /
    • 2013
  • Maintenance works for current high-rise buildings significantly depend on human labor, unlike other construction processes that are gradually being automated. Herein, this paper proposes robotic building maintenance system using motion control, in specific, reducing a system jerk which is directly subjected to improve the process performance and economic feasibility. The sensor for detecting straight and curvature section of the building facade, moreover rail-joint segment can be detected and be utilized for reducing jerk of the system. Analysis of the proposed system error caused by excessive vibration, e.g. jerk motion is introduced. To enhance the stability and safety of the system, herein, the strategy is proposed for enhancing the performance of the system based on anti-jerk motion control algorithm which comes out increasing the stability and sustainability of the integrated system, as well.

A Process of Optimization for the Best Orientation of Building Façades Based on the Genetic Algorithm by Utilizing Digital Topographic Map Data (수치지형도 데이터를 활용한 유전자 알고리즘 기반 건축외피의 최적향 산정 프로세스)

  • Choe, Seung-Ju;Han, Seung-Hoon
    • Land and Housing Review
    • /
    • v.13 no.1
    • /
    • pp.113-129
    • /
    • 2022
  • A building's eco-friendliness is directly related to various values including the life cycle cost of a building. However, the conventional architectural design method has a limitation in that it cannot create an optimized case according to the surrounding environmental conditions. Therefore, the purpose of this research is to present a design assistance tool that can review planning cases optimized for the environmental conditions of the building site in the planning stage of architectural production. To achieve the purpose of the study, an algorithm for realizing 3D modeling of the region and analysis of the solar environment was produced based on the site contours, building, and road information from the digital topographic map provided by the National Geographic Information Institute. To examine the validity of the developed algorithm, a comparative experiment was conducted targeting the elevation direction of the existing building. As a result, it was found that the optimal elevation direction selected by the algorithm can receive higher insolation compared to the front facade of the main building.

The Development of Performance Evaluation Program of Building Integrated Photovoltaic System (건물일체형 태양광발전 시스템 성능평가 프로그램 개발)

  • Kim, Beob-Jeon;Park, Jae-Wan;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.85-90
    • /
    • 2015
  • Purpose: In design and planning Building Integrated Photovoltaic(BIPV) system can reduce cost by replacing building facade as construction material such as roofs, outer walls and windows as well as generating electricity. BIPV system should be applied at the early stage of architectural design. However, it is hard to decide whether using BIPV system or not for architects and builders who are not professional at BIPV system because performance of system is considerably influenced by types of module, installation position, installation methods and so on. It is also hard for experts because commercialized analytical program of photovoltaic systems is too complicated to use and domestic meteorological data is limited to partial areas. Therefore, we need evaluation program of BIPV system which can easily but accurately interpret generating performance and evaluate validity of BIPV system at the early stage of architectural design even for inexpert. Method: In this study, we collected meteorological data of domestic major region and analyzed generation characteristic of BIPV system by using PVsyst(commercialized software) in accordance with regions, types of solar module, place and methods of installation and so on. Based on this data, we developed performance evaluation program of BIPV system named BIPV-Pro, through multiple regression analysis and evaluated its validity. Result: When comparing predictive value of annual average PR and annual electricity production of BIPV-Pro an that of PVsyst, each of root mean square error was 0.01897 and 123.9.

The verification about possibility of introducing Window to Floor Ratio as design index for building energy performance

  • Choi, Won-Ki;Lee, Yong-Jun;Lee, Hyun-Soo;Eom, Jae-Yong;Lee, Chung-Kook
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • Purpose: Many design index that are using in planning phase have been developed. The most popular things among them are Window to Wall Ratio and Surface to Volume Ratio. However there are some limits. Window to Wall Ratio cannot consider building size and Surface to Volume Ratio cannot do Window to Wall Ratio. Accordingly, in this paper, the Window to Floor Ratio was proposed that it can be considered both building size and Window to Wall Ratio. And analyzed correlation of energy demand. Method: For the test, 16 modules with the size of $6m{\times}6m{\times}4m$ were used to make 35 models with the same volume. The simulation was conducted to 945 cases using the window-to-wall ratio of 30, 50 and 70 % in three areas such as Seoul, Gwangju and Jeju and three kinds of windows. And IES_VE was used. Result: The findings above show that the Window to Floor Ratio that can be considered both building size and Window area have to become as design index. It was found out that design criteria with SHGC is necessary, not with the thermal performance (U-value). It is needed to additional analysis about residential building and the effect of 24-hours heating and cooling condition. It plans to carry out research to establish design indicators for climatic conditions in the country and building applications.

An Analysis of Façade Panel Characteristics of UN Studio's Office Projects (유엔스튜디오 업무시설 외피 패널의 형태적 특성 분석)

  • Ko, Sung Hak
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.8
    • /
    • pp.23-34
    • /
    • 2019
  • The façade, a fundamental function as a skin that protects human life from external environment such as cold and hot weather, snow, rain, and wind, etc, has served as a media for communication between indoor space of the building and outside space. From the media for communication point of view, the approach to envelope design, in which environmental elements are transmitted internally through the filtering of external environments, has been evolving in various ways from the past to the present. Today, modern architecture technologies including curtain wall systems and user-friendly computer programming and environmental analysis programs demonstrate a differentiated approach to envelope design related to the indoor environment. For this reason, it is worth noting that the envelope design factors and trends that appear variously in the UNStudio's projects before and after the 2000s. The factors reflected in the envelop design in conjunction with the indoor environment obtained through the case study of the UNStudio's office projects were daylight environment, thermal environment, ventilation, noise, privacy and view, and consideration for daylight environment and thermal environment was reflected in many cases through the case study. Looking at the changes in the diagrams in order of year, it can be seen that the envelope design using the environmental analysis tool has been performed since 2006. This is a clue to show the envelop design changes from the conceptual method to the data-based one. The diagrams and analysis results related to the envelop design showed that the thermal environment related to solar radiation was the most, and no diagrams and analysis related to the indoor illumination were found. Since 2010, PV panel installation has been shown in the envelope design, which can be found in the increased efficiency of PV panels due to the technological advances and the decrease in production cost.

Analysis of Thermal Environment Improving Effects of Green Curtain in Summer (Green Curtain 형식의 벽면녹화시스템을 통한 여름철 건물 실내 열환경 비교 분석)

  • Lee, Sunyoung;Jo, Sangman;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.5
    • /
    • pp.80-89
    • /
    • 2022
  • In order to solve the limitations of horizontal thermal environment improvement, this study compared the thermal environment of the indoor and outdoor of a building in summer according to the presence or absence of a green curtain, a vertical greening method. In the summer of 2021, the air temperature, relative humidity, wind speed, and shortwave and longwave radiation were measured at a central point inside a building and the grass field outside of the building to determine the human thermal sensation index, PET and UTCI. As a result, the green curtain showed an average 1.6℃ cooler air temperature during the daytime, but it did not have an effect at night. For relative humidity, it showed higher humidity indoors by an average of 5.6% and 1.0% during the daytime and at night, respectively. Wind speed was 1.4-1.8 ms-1 and 1.4-1.5 ms-1 higher outdoors on average during the daytime and at night, respectively, showing a high value outdoors regardless of whether a green curtain was installed. The green curtain showed an average indoor mean radiant temperature reduction effect of 4.7℃ during the daytime, but it did not have an effect at night. In PET and UTCI, the green curtain reduced the indoor PET by about a 1/3 level, an average of 2.1℃, and the indoor UTCI by about a 1/6 level, an average of 1.1℃, during the daytime. However, no effects appeared in PET and UTCI at night. For landscape planning, a green curtain can effectively modify the thermal environment during the daytime in summer.