• 제목/요약/키워드: Fabric filter

검색결과 75건 처리시간 0.023초

기후변화 대응을 위한 수처리 여과시스템 선정 방안 연구 (Study on Selection of Water Treatment Filtration System to Cope with Climate Change)

  • 황윤빈;박기학
    • 한국기후변화학회지
    • /
    • 제9권1호
    • /
    • pp.75-80
    • /
    • 2018
  • The problem of water shortages and water related disasters caused by climate change has increased the seriousness of water problems and the importance of water treatment technology capable of securing clean water is expanding. In this study, we analyzed not only the water pollutant generated by the filtration system technology of various water treatment technologies but also the indirect greenhouse gas emissions generation, and analyzed the influence on the environment. The subjects of study are Fabric Filter, Reverse Osmosis System and Pressurized Microfiltration Device which are widely used for water treatment and we analyzed the impact on the environment using the Life Cycle Assessment (LCA) method using the electricity amount necessary for use, the water purification efficiency, the throughput per ton and the cost. The amount of greenhouse gas generated when the Pressurized Microfiltration Device operates for 1 year is $2.15E+04kg\;CO_2-eq$., Fabric Filter is $3.29E+04kg\;CO_2-eq$., and Reverse Osmosis System is $1.68E+05kg\;CO_2-eq$. As a result of analyzing the amount of greenhouse gas generated at the time of purifying 1 ton of the Pressurized Microfiltration Device and the conventional filtration system, the Pressurized Microfiltration Device was $20.5g\;CO_2-eq$., Fabric Filter was $34.7g\;CO_2-eq$., and Reverse Osmosis System was $191.7g\;CO_2-eq$. The amount of greenhouse gas generated was calculated to be 41.0% less than that of the Fabric Filter by the Pressurized Microfiltration Device and 89.3% less than the Reverse Osmosis System. From the viewpoint of climate change, it is necessary to select a filtration system that takes climate change into account, not from the viewpoint of water quality removal efficiency and economic efficiency according to future water treatment applications, and it is necessary to select a water treatment filtration system more researches and improvements will be made for.

필터 케익내의 압축현상에 관한 연구 (A Study on the Compression Behaviour of Filter Cake)

  • 김정민;정용원
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 1999년도 추계학술대회 논문집
    • /
    • pp.469-470
    • /
    • 1999
  • 본 연구는 가스 중에 포함되어 있는 입자들을 fabric filter를 이용하여 집진할 때 형성되는 dust filter cake의 구조 및 압력강하가 입자간의 부착력(adhesion force), 마찰계수(friction coefficient)등의 여러 관련변수에 따라 변화되는 양상을 전산모사를 통해 예측하고자 하는 것이다.(중략)

  • PDF

부직포 및 황 충진 MBR을 이용한 포기조내 동시 질산화/탈질에 관한 연구 (Simultaneous Nitrification and Denitrification using Submerged MBR packed with Granular Sulfur and Non-woven Fabric)

  • 문진영;황용우;박지형
    • 상하수도학회지
    • /
    • 제23권4호
    • /
    • pp.439-446
    • /
    • 2009
  • This study was performed to evaluate SND(simultaneous nitrification and denitrification)efficiency, nitrogen removal efficiency and filtration function of non-woven fabric by using submerging MBR packed with granular sulfur covered with non-woven fabric filter. Synthetic wastewater was used as influent wastewater. Concentration of $NH_4{^+}-N$ in influent was maintained about 40 mg/L and the experiment was performed in four phases according to the flow rate. Nitrogen loading rate divided four phases ranging from $0.04 kg\;NH_4{^+}-N/m^3-day$ to $0.16 kg\;NH_4{^+}-N/m^3-day$. As a result, the maximum $NH_4{^+}-N$ removal rate was accomplished at $0.142 kg\;NH_4{^+}-N/m^3-day$ in nitrogen loading of $0.147 kg\;NH_4{^+}-N/m^3-day$. Nitrification efficiency was higher than 95% in all phases. $NO_3{^-}-N$ loading rate was adjusted ranging from $0.22 kg\;NO_3{^-}-N/m^3-day$ to $0.89 kg\;NO_3{^-}-N/m^3-day$. The maximum $NO_3{^-}-N$ removal rate was accomplished up to $0.71 kg\;NO_3{^-}-N/m^3-day$ in $NO_3{^-}-N$ loading of $0.89 kg\;NO_3{^-}-N/m^3-day$. The maximum $NO_3{^-}-N$ removal efficiency was 95% in $NO_3{^-}-N$ loading of $0.22 kg\;NO_3{^-}-N/m^3-day$. T-N removal rate was 90% and concentration of T-N in effluent was 3.7 mg/L in T-N loading rate of $0.039 kg\;NO_3{^-}-N/m^3-day$. In this study, TMP in reactor with and without non-woven fabric filter were observed to define fouling of hollow-fiber membrane module. Reaching time to standard washing pressure(22 cm Hg) of two reactors were 29 days with non-woven fabric But the reactor without non-woven fabric reached standard washing pressure only after 4 days. Accordingly, non-woven fabric was demonstrated the superiority as a filtration ability. With high nitrogen removal rate and decreasing of fouling of membrane, MBR packed with granular sulfur covered with non-woven fabric filter submerging in activated sludge aeration tank can be used as an advanced treatment process.

A Sobel Operator Combined with Patch Statistics Algorithm for Fabric Defect Detection

  • Jiang, Jiein;Jin, Zilong;Wang, Boheng;Ma, Li;Cui, Yan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권2호
    • /
    • pp.687-701
    • /
    • 2020
  • In the production of industrial fabric, it needs automatic real-time system to detect defects on the fabric for assuring the defect-free products flow to the market. At present, many visual-based methods are designed for detecting the fabric defects, but they usually lead to high false alarm. Base on this reason, we propose a Sobel operator combined with patch statistics (SOPS) algorithm for defects detection. First, we describe the defect detection model. mean filter is applied to preprocess the acquired image. Then, Sobel operator (SO) is applied to deal with the defect image, and we can get a coarse binary image. Finally, the binary image can be divided into many patches. For a given patch, a threshold is used to decide whether the patch is defect-free or not. Finally, a new image will be reconstructed, and we did a loop for the reconstructed image to suppress defects noise. Experiments show that the proposed SOPS algorithm is effective.

주름필터를 적용한 CYBAGFILTER®의 여과성능 특성 (Dust Filtration Characteristics of Pleated Filter Bags Installed in CYBAGFILTER®)

  • 박영옥;노학재;이영우
    • 한국대기환경학회지
    • /
    • 제24권4호
    • /
    • pp.483-491
    • /
    • 2008
  • The filtration characteristics of $CYBAGFILTER^{(R)}$ unit with pleated filter bags were evaluated by comparing the performance of the unit with the lower part of cyclone shape with that of the unit with conventional lower part. Results from the test were also compared with those from the previous research with the $CYBAGFILTER^{(R)}$ in which round filter bags were installed. $CYBAGFILTER^{(R)}$ is the unit which combines the centrifugal separation mechanism and the fabric filtration mechanism in a single unit for efficient removal of particulate matters. The pleated filter bags are made of pleated fabric with an extension of the filtration area about 3 times compared with the conventional round filter bags. The results from the test using pleated filter bags showed an overall collection efficiency of over 99.9% regardless of the shape of lower part installed. When the lower part of cyclone shape was installed, the filter cleaning interval was over 2 times longer compared with that when the conventional lower part was installed. At the same conditions of filtration velocity and filter pressure drop, the $CYBAGFILTER^{(R)}$ with the lower part of cyclone shape, in which the pleated filter bags are installed, can be operated with a flow rate of round 3 times higher than that with conventional round filter bags.

섬유필터를 사용한 강우유출수의 부유물질 제거 방법의 개발 (Removal of Suspended Solids from Stormwater Runoff Using a Fabric Filter System)

  • 구영민;김재영;김병로;서동일
    • 대한환경공학회지
    • /
    • 제37권3호
    • /
    • pp.165-174
    • /
    • 2015
  • 강우시 표면유출에 의해 지표수에 유입되는 우수에는 토사를 포함한 각종 비점오염 물질이 다량 포함되어 있으며 이는 지표수의 수질관리에 부정적인 영향을 미치고 있다. 유역의 오염물질이 수계에 도달하기 전에 처리하는 것이 바람직하며 따라서 강우유출수를 처리하는 다양한 방법들이 시도되고 있다. 그러나 일반적인 빗물오염 제어시설 및 장치들은 설치 및 유지관리를 위해 많은 노력과 비용을 요구하는 문제점 가지고 있다. 본 연구에서는 유역의 초기우수에 의한 오염을 제어하기 위해 경제적으로 타당하고 설치 및 관리가 용이한 섬유 필터를 이용하여 부유물질을 제거할 수 있는 방법을 개발하였다. 여재는 경제적이면서 내구성이 우수한 폴리에스터계열의 섬유 필터를 사용하였으며, 연구 대상지역 강우유출수의 입도분석 결과에 따라 $20{\mu}m{\sim}94{\mu}m$ 범위에서 다양한 공극의 여재에 대한 성능을 실험을 통해 분석하였다. 수두별 여과성능을 분석하기 위한 실험 장치를 고안 제작하여 필터 공극에 따른 섬유 필터의 TSS 제거 효율을 평가 하였다. 수두가 높을수록 여과속도가 증가하는 것을 확인하였으며 공극별 여과 속도를 측정하여 분석하였다. 섬유 필터의 공극 크기가 작을수록 TSS 제거효율이 증가되었으나, 공극별 TSS 제거 효율은 대체적으로 양호하나 유사한 편으로서 TSS의 대부분의 질량은 입자의 크기가 큰 부분에 치중되어 있는 것이 주요 원인으로 분석된다.

활성슬러지조내 부직포 여재 관형필터의 고액분리 특성 평가 (Evaluation of Tubular Type Non-woven Fabric Filter for Solid-liquid Separation in Activated Sludge Reactor)

  • 서규태;이택순;박영미
    • 대한환경공학회지
    • /
    • 제30권2호
    • /
    • pp.234-238
    • /
    • 2008
  • 활성슬러지 공정에 막을 침지한 MBR(Membrane Bioreactor)공정에서 고가의 막을 대체하여 부직포 같은 섬유 여과막을 이용한 연구가 수행되었다. 부직포는 저렴한 가격, 저압에서 높은 투과유속의 확보 등 막을 대체할 수 있는 대안으로서 가치가 높다. 그러나 부직포 여과막 모듈은 막에 비하여 비표면적이 현저하게 작기 때문에 이를 증가시키는 노력이 필요하다. 본 연구에서는 활성슬러지 공정에 부직포 여과 관형 막모듈을 침지하여 설치형태와 관직경에 따라 여과압력에 미치는 영향을 실험적으로 검토하였다. 관형 필터의 직경이 같을 때, 반응조내 필터 모듈의 설치형태가 여과압력 변화에 미치는 영향은 없었다. 그러나 필터의 관 직경이 작을수록 여과압력의 상승이 빠르게 나타났고 이는 관내 수리학적 손실에 기인된 것으로 해석되었다. 따라서 관형 부직포 여과막은 관경 10 mm 이상에서 비표면적을 고려하여 설계하고, 반응조내 수직형으로 설치함이 적정한 것으로 나타났다.

은나노를 부착한 활성탄 필터의 제균특성 (Antibacterial Characteristics of Silver Nano-Particles Attached to Activated Carbon Filter)

  • 허주영;남상엽;강정희;송지현;강병하;한성
    • 설비공학논문집
    • /
    • 제21권10호
    • /
    • pp.583-589
    • /
    • 2009
  • Activated carbon has long been used in purification processes for indoor air quality. However, the bioaerosol removal by activated carbon is not often sufficient to be used in an air control devise. In order to overcome these problems, silver nano-particles have been proposed as an antibacterial agent on the surface of activated carbon. Silver or silver ions have been known for antimicrobial activities. In this study, bioaerosol generated by using an Escherichia coli culture was introduced to a lab-scale column packed with activated carbon (AC) and silver nano-particles attached to activated carbon (Ag-AC). E. coli was almost completely removed in the Ag-AC column, whereas bioaerosol penetrated through the AC column. To determine the antibacterial effect of different filter materials in a full-scale air-handling system, another experiment was conducted using a wind tunnel equipped with a heat exchanger and three filter materials including commercial fabric, AC and Ag-AC. It was found that E. coli proliferated on the surface of the heat exchanger after 5 days, which dramatically increased bioaerosol counts in the effluent air stream. The fabric filter could not control the increased bioaerosol and most of the E. coli penetrated the filter. The bacterial removal efficiency was found to be approximately 45% in the AC filter, while the antibacterial efficiency increased to 70% using the Ag-AC filter. Consequently, the Ag-AC filter can be an effective method to control bioaerosol and improve indoor air quality.