• Title/Summary/Keyword: FWHM

Search Result 656, Processing Time 0.026 seconds

Bandwidth Analysis of High-order Pulse for the Transmission of Ultrashort Laser Pulses (극초단펄스 전송을 위한 고차원펄스의 스펙트럼 대역 분석)

  • 전진성;조형래;오용선
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.237-242
    • /
    • 1999
  • In this paper, we analyze transmission characteristics of ultrashort laser pulses using the property of high-order pulses which are systematically obtained following their orders. The high-order pulses are easily derived from a modified PRS system model. But we make clear they are very useful to cover wider area and more accurate transmission characteristics of ultrashort pulses than Gaussian or Sech pulse approximations used conventionally. This may be based on the fact that the spectra and bandwidths of the high-order pulses are beautifully related to their orders. first modifying the generalized PRS system model, we propose a new model for deriving any type of high-order pulse. And we offer a novel analysis method of ultrashort pulse transmission which has any shape and FWHM, using the proposed model. In addition, by fixing the pulse range $\tau$=1(ps) and varying the order of the pulse from n:1 to n=100, we obtain spectra of ultrashort pulses with 1(ps)-150(fs) FWHM's, which are widely used in fiber communications. As a one-step further, we derive PSD's of their pulse trains when they are applied to Unipolar signaling scheme. These PSD's are decided in the range of possible pulse intervals. All of these results are not only coincided with some conventional experimental works but also will be applied to any pioneering ultrashort pulse in the future.

  • PDF

A Study on the Wedge shape Detector of Very High Resolution Positron Emission computer Tomography (초고해상도 양전자 방출 CT의 쐐기형 검출기에 관한 연구)

  • 이행세;이태원
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.2
    • /
    • pp.44-54
    • /
    • 1985
  • The high resolution of positron emission tomography, in particular, requires the use of detector crystals of narrow width but still with sufficiently high detection efficiency. If the crystal width is reduced to several millimeters, degradation of detection efficiency and leakage coefficient becomes significant, particularly in case of obliquely incident photons. Alleviation of such a problem can be made possible by modification of the detector shape from the conventional rectangular type to a wed농e type. The Proposed wedge shape makes the absorption length longer for obliquely incident photons, thus increasing the detection efficiency and suppressing leakage coefficient. For the BGO detectors of 4-8mm width, the computer simulation result of the system using wedge detectors reveals resolution improvement to the system using conventional detectors. For the system composed of 200 BGO detectors of 8mm width with 2 point sampling motion, the simulation resolution system using conventional detectors. For the very high resolution system of 3-7mm FWHM, the characteristics of the detector shape and size is studied by computer simulation.

  • PDF

Performance Evaluation of Breast Specific Gamma Imaging (Breast Specific Gamma Imaging 장비의 성능평가)

  • Cha, Eun-Sun;Kwak, In-Suk;Noh, Ik-Sang;Yeon, Joon-Ho;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.24-27
    • /
    • 2010
  • Purpose: Early diagnosis of breast is of the utmost importance to improve prognosis. We have a limitation for mammography and sonography detecting small cancer. Clinical importance of Breast Specific Gamma Imaging (BSGI) has improved for that reason. So We studied performance evaluation test of count rate and resolution with high sensitivity to the low dose of BSGI. Materials and Methods: BSGI of Dilon 6800, point source of $^{99m}Tc$ from 1.85~148 MBq (0.05~4 mCi) at the intervals of 1.85~37 MBq (0.05~1 mCi) was used for the test. Performance evaluation method was performed for measuring deadtime for choosing at the 5 different point in the useful field of view (UFOV), acquired image for 60 seconds. Compared with reference of clinical uptake distribution of breast, activity increased according to the distance change 10, 20, 30, 40, 50 mm in the useful field of view. Results: Counting curve increased according to the activity from 1.85 MBq (0.05 mCi) to the 74 MBq (2 mCi), and it change flat shape over 74 MBq (2 mCi). The variation of the full width of half maximum (FWHM) to the distance is 4.05, 4.73, 5.77, 6.90, 8.00, 9.32 mm in 1.85 MBq (0.05 mCi), 4.30, 4.80, 5.90, 7.00, 8.10, 9.07 mm in 3.7 MBq (0.1 mCi), 4.90, 5.60, 6.20, 7.20, 8.20, 9.10 mm in 5.55 MBq (0.15 mCi), 5.30, 6.10, 6.60, 7.00, 7.90, 8.70 mm in 7.40 MBq (0.2 mCi). Conclusion: Distortions of image would be acquired because of the deadtime in BSGI. We found out the fact that specification of $^{99m}Tc$ reaction under 74 MBq (2 mCi) for BSGI. Second, FWHM distribution change from varied distance from the detector, clearly distinguished the location of the lesion.

  • PDF

Performance Measurements of Positron Emission Tomography: An Investigation Using General Electric $Advance^{TM}$ (양전자방출단층촬영기의 표준 성능평가 방법: GE $Advance^{TM}$에 적용한 예)

  • Lee, J.R.;Choi, Y.;Choe, Y.S.;Lee, K.H.;Kim, S.E.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.548-559
    • /
    • 1996
  • A series of performance measurements of positron emission tomography (PET) were performed following the recommendations of the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. We investigated the performance of the General Electric $Advance^{TM}$ PET. The measurements include the basic intrinsic tests of spatial resolution, scatter fraction, sensitivity, and count rate losses and randoms. They also include the tests of the accuracy of corrections: count rate linearity correction, uniformity correction, scatter correction and attenuation correction. GE $Advance^{TM}$ PET has bismuth germanate oxide crystals (4.0mm transaxial ${\times}$ 8.1mm axial ${\times}$ 30.0mm radial) in 18 rings, which form 35 imaging planes spaced by 4.25mm. The system has retractable tungsten septa 1mm thick and 12cm long. Transaxial resolution was 4.92mm FWHM in 2D and 5.14mm FWHM in 3D at the center. Average axial resolution in 2D decreased from 3.91mm FWHM at the center to 6.49mm FWHM at R=20cm. Average scatter fraction of direct and cross slices was 9.57%. Dead-time losses of 50% corresponded to a radioactivity concentration of $4.86{\mu}Ci/cc$ and a true count rate of 519 kcps in 2D. The accuracy of count rate linearity correction was 1.84% at the activity of $4.50{\mu}Ci/cc$. Non-uniformity was 2.06% in 2D and 2.93% in 3D. Remnant errors after scatter correction were 0.55% in 2D and 4.12% in 3D. The errors of attenuation correction were 6.21% (air), 0.20% (water), -6.32% (teflon) in 2D and 5.00% (air), 6.94% (water), 3.01% (teflon) in 3D. The results indicate the performance of GE $Advance^{TM}$ PET scanner to be well suited for clinical and research applications.

  • PDF

The Evaluation of Images with Various Filters in I-131 SPECT/CT (I-131 SPECT/CT에서 Ringing Artifact 감소를 위한 다양한 Filter값의 적용)

  • Kim, Ha Gyun;Kim, Soo Mee;Woo, Jae Ryong;Oh, So Won;Lee, Jae Sung;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.62-68
    • /
    • 2014
  • Purpose: After I-131 therapy, SPECT/CT is useful in identifying location of thyroid remnants and metastasis of thyroid cancers. An excessive uptake of thyroid leads to a ringing artifact in the SPECT images. The aim of this study is to investigate and suggest a proper post filters to remove ringing artifact and produce better image quality. Materials and Methods: A low-cost, customized thyroid-mimicking phantom, consisting of an acrylic bottle and a hollow sphere was used for SPECT/CT Discovery (GE Healthcare, USA). It was filled with I-131 solution. The ratio of hollow sphere to background were varied as 50:1, 200:1, 1000:1 and 4000:1. Acquired images were reconstructed by OSEM (2 iterations, 10 subsets) with and without Evolution (resolution recovery correction, GE). Three different post-filters were applied; Butterworth (cut off: 0.38 to 0.58 with intervals of 0.05), Hanning (cut off: 0.8 to 1 with intervals of 0.05) and Gaussian (FWHM: 3 to 5 with intervals of 0.5) filters. Contrast, background variability, air area variability, and full width half maximum (FWHM) were compared. Results: Higher contrasts were obtained from the SPECT images with Evolution than without Evolution. In the case of images without Evolution, image distortion such as star artifact was generated. For all sphere-to-background ratio, the Butterworth filter showed better constrasts and FWHMs than other two filters, but the ringing artifact was still generated in all studies except 50:1 and it was decreased as cutoff value was increased. The ringing artifact didn't appear with Hanning and Gaussian filters at all studies, however constrats and FWHMs with Gaussian was worse than Hanning filter. For the images having ringing artifacts, the background variability and air area variability were increased. Conclusion: In this study, we suggested that it is desirable to use Hanning filter when the ringing artifact is generated and to use Butterworth filter when ringing artifact is not generated in I-131 SPECT.

  • PDF

Synthesis of (110) oriented diamond films by microwave plasma enhanced chemical vapor deposition (마이크로파 플라즈마 화학기상성장법에 의해 (110)면으로 배향된 다이아몬드막의 합성)

  • 박재철;박상현
    • Electrical & Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.270-276
    • /
    • 1996
  • As methane concentration was varied, the textures of diamond films deposited on Si(100)substrate were observed by XRD,SEM and Raman spectroscope. As a result, $O_{2}$ plasma etching has been useful to observe microscopic structure of diamond films by SEM. The cross section of diamond films deposited on Si(100)substrate with 4% concentration of methane to hydrogen was a polycrystal like a pillar. The diamond crystal like a pillar has been oriented to (110)surface and the high quality diamond film with FWHM of Raman spectra being 3.8 $cm^{-1}$ / has been grown. As time goes by deposition time, the preferred orientation increases

  • PDF

Growth of Zn-chalcogenide epilayers by hot-wall epitaxy and their structural properties (Hot-wall epitaxy에 의한 Zn-chalcogenide 에피층의 성장 및 구조적 특성)

  • 유영문;남성운;이종광;오병성;이기선;최용대;이종원
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4A
    • /
    • pp.470-475
    • /
    • 1999
  • ZnS and ZnTe epilayers were grown on GaAs(100) GaP(100) substrates by hot-wall eitaxy. X-ray diffraction revealed that the epilayers have zinc-blende structure and were grown in (100) direction. The small values of the full width at half maximum (FWHM) of double crystal rocking curve (DCRC) showed high quality of the epilayers. From the thickness dependence of the FWHM of DCRC, the strain remaining in films is found to be due to the thermal expansion difference as well as due to the lattice mismatch.

  • PDF

A Study on parameter optimization and output stabilization of Magnetic Switch System. (자기스위치 시스템의 파라메다 최적화 및 출력 안정화에 관한 연구)

  • Jun, Sang-Young;Lee, Choo-Hie
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.637-641
    • /
    • 1989
  • We have developed 3-stage of Magnetic Switch System based on the nonlinearities of ferromagnetic material used in the saturable inductor, and made experiment of parameter optimization and output stabilization of Magnetic Switch System. The cross-section and conductor burns of each satarable inductor were optimized 30 $cm^2$ 19.25 $cm^2$ 5, and 25 $cm^2$ 2, respectively. With this condition, 6.2 us [FWHM], 96 A pulse at first stage was compressed into 0.4 us[FWHM], 1.61 kA pulse at last stage. The current gain and compression ratio were 16.8, 17, respectively. ln addition, System output was stabilized with reset current of 6 A, 200 us.

  • PDF

Texture development in cold-roiled and heat-treated Ni tapes (냉간가공과 열처리한 Ni 테이프에서의 집합조직 발달)

  • 이동욱;지봉기;임준형;주진호;정충환;박순동;전병혁;홍계원;김찬중
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.535-538
    • /
    • 2002
  • Cube-textured Ni substrates for YBCO coated conductors were fabricated by cold-rolling and annealing of Ni powder compacts. To establish the optimum sintering temperature, tensile test was performed for the Ni rod sintered at various temperatures. The Ni rods prepared at above 100$0^{\circ}C$ showed good mechanical properties due to the complete densification of the Ni rods. The Ni rods were rolled to final thickness of 100 ${\mu}{\textrm}{m}$ and then annealed at 100$0^{\circ}C$ for various annealing time for texture development. The texture analysis made by 2 $\theta$ scan and pole-figure showed that the cube texture was developed in a short time of a few munitues. The FWHM of in-plane and out of plane texture of the prepared Ni tapes was 8-10$^{\circ}$. The AEM surface roughness of the Ni tapes was as smooth as 3 nm.

  • PDF