• Title/Summary/Keyword: FTA: Fault Tree Analysis

Search Result 151, Processing Time 0.026 seconds

Emergency Evacuation Scenario Study of Urban Metro Vehicle Running on Elevated Guideway (도시철도차량의 고가선로 비상대피 시나리오 분석)

  • Kim, Young-Sang;Maeng, Hee-Young;Wang, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.117-124
    • /
    • 2012
  • There have been recently introduced new types of urban metro vehicles called LRT (Light Rail Transit) running on elevated guideway such as Uijeongbu VAL(which stands for V$\acute{e}$hicule Automatique L$\acute{e}$ger: Automatic Light Rail Vehicle) system, Yong-In LIM(Linear Induction Motor) system, Incheon international airport MAGLEV(Magnetic Levitated Vehicle) system and Daegu monorail system. Most of accidents by the vehicles are bound to happen on elevated guideway. Therefore, it is of vital importance to analyze hazards related to vehicles running on elevated guideway and study emergency evacuation scenarios applicable in case of accidents on elevated guideway so as to secure the safety of the new types of urban metro vehicles. In this study, FTA(Fault Tree Analysis) model was developed to identify all possible hazards, and all possible evacuation scenarios were studied. It was also confirmed that each hazard can be corresponded to one or more evacuation scenarios. This result shows that passengers can be evacuated according to one of the scenarios identified in this study in case of an accident of "Train Stranded on Elevated Guideway".

Two-Layer Approach Using FTA and BBN for Reliability Analysis of Combat Systems (전투 시스템의 신뢰성 분석을 위한 FTA와 BBN을 이용한 2계층 접근에 관한 연구)

  • Kang, Ji-Won;Lee, Jang-Se
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.3
    • /
    • pp.333-340
    • /
    • 2019
  • A combat system performs a given mission enduring various threats. It is important to analyze the reliability of combat systems in order to increase their ability to perform a given mission. Most of studies considered no threat or on threat and didn't analyze all the dependent relationships among the components. In this paper, we analyze the loss probability of the function of the combat system and use it to analyze the reliability. The proposed method is divided into two layers, A lower layer and a upper layer. In lower layer, the failure probability of each components is derived by using FTA to consider various threats. In the upper layer, The loss probability of function is analyzed using the failure probability of the component derived from lower layer and BBN in order to consider the dependent relationships among the components. Using the proposed method, it is possible to analyze considering various threats and the dependency between components.

A Study of Life about Naturally Aged Nitrocellulose by Storage (자연 노화된 니트로셀룰로오스의 수명에 관한 연구)

  • Kim, Dong-seong;Jin, Hong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.595-601
    • /
    • 2020
  • During the safety inspection of nitrocellulose-made explosive containers stored for more than 10 years, cracks were found in the containers. Therefore, a failure cause analysis test was performed. First, the cause of failure through the failure tree analysis was conducted to select the factors that influenced failure. The changes in the properties of the container caused by the acceleration of the reaction were found to be the cause of the failure by confirming the influence on the environment and internal/external factors that may occur during storage. To confirm this, environmental tests, such as thermal shock test and vacuum thermal stability test, were performed using a naturally aged container to analyze the cause of failure, and an accelerated aging test was performed to reproduce the failure. Through this, the chemical reaction was accelerated by heat and charge, as in the result of the fault tree analysis, and it was confirmed that the physical properties of the container were changed. In addition, the service life of the container was estimated using the Arrhenius model for the storage life due to thermal aging.

Failure Mode Effective Analysis for selection of Single Point Vulnerability in New type Nuclear Power Plant (신규노형 원전의 발전정지유발기기 선정을 위한 고장모드영향분석)

  • Hyun, Jin Woo;Yeam, Dong Un
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • For decreasing an unexpected shutdown of Nuclear Power Plants, Korea Hydro & Nuclear Power co.(KHNP) has developed Single Point Vulnerability(SPV) of NPPs since 2008. SPV is the equipment that cause reactor shutdown & turbine trip or more than 50% power rundown due to its malfunction. New type Nuclear Power Plants need to develop the SPV list, so performed the SPV selection for about 1 year. To develop this, Failure Mode Effect Analysis(FMEA) methods are used. As results of FMEA analysis, about 700 equipment are selected as SPV. Thereafter those are going to be applied to new type Nuclear Power Plants to enhance equipment reliability.

A Study on the Safety Demonstration of Train Control System (열차제어시스템의 안전입증에 관한 연구)

  • Shin Duc-Ko;Lee Jae-Ho;Lee Kang-Mi;Hwang Jong-Kyu;Joung Eui-Jin;Wang Jong-Bae;Park Young-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.412-418
    • /
    • 2006
  • In this paper we deal with the APARP theory which has been applied for UK railway system and risk assessment method which has been using in the domestic railway system for the safety demonstration. Both techniques are applied to the ATP wayside equipment for interface. Also, fur the applications of each techniques a analysis of the safety activity and a possibility of the application of ALARP theory are evaluated. Finally, we generate requirements of the safety demonstration for the future domestic railway system by way of the analysis of some assumptions and requirement data which can be applied to the risk assessment of ALARP.

An analysis on marine casualties of fishing vessel by FTA method (결함수 분석 (FTA) 기법을 이용한 어선 해양 사고 분석)

  • KIM, Su-Hyung;KIM, Hyung-Suk;KANG, Il-Kwon;KIM, Wook-Sung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.4
    • /
    • pp.430-436
    • /
    • 2017
  • The most frequent occurring and the serious marine casualties in fishing vessels are the collision in statistics from Korea Maritime Safety Tribunal (2008-2015). Collisions are is given a great deal of weight in all marine casualties, and the main cause of collisions is the negligence of watching. From this point of view, this study deals with the collision and its immediate cause, the negligence of watching which are main factors on the indirect causes. Basic analyzing data was gathered from the questionnaire made by experts of sea service part, and analyzed by using the fault tree analysis (FTA). From the result of the study, the occurrent probability of the negligence of watching in the collision due to the indirect causes occupied 64.9%, and its probability caused by the man factors was less than the other factors; i.e. the media factors and the management factors. For the reduction of the negligence of watching in the collision from this study, it needs an effort to remove not only the man factors, but also the media factors and management factors.

A Risk Assessment Approach to Safety Management of Electric Railway Facilities (전기철도 전철전력설비의 위험도 평가 기반 안전관리에 관한 연구)

  • Jang, Yoon-Suk;Choi, Kyu-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.960-967
    • /
    • 2009
  • Power supply system of electric railway has a diversity of safety problems since it should supply high electric power to the trains moving high speed with a lot of passengers on board. This paper provides a risk assessment approach to safety management of the electric railway facilities. Construction of database from field accident information, risk assessment and management of the risk are carried out systematically to ensure the safety. The risk assessment includes hazard identification, cause analysis by FTA(Fault Tree Analysis), consequence analysis by EVA(Event Tree Analysis), and loss analysis. In terms of the severity and the probability of the accidents deduced by these analyses, the risk of the accidents is assessed by using a risk matrix designed for electric railway facilities. Based on the risk assessment, possible risk mitigation options are identified and evaluated by analyzing their impact on the risk reduction and their cost benefit ratio. The long-term safety of the electric railway facilities can be ensured by renewal of the risk assessment and the risk mitigation option analysis with continuous accident database update. The proposed approach is applied to the electric railway facilities of Korean railway based on the accident data from 2002 to 2008.

Cause Analysis and Improvement of Signal Interference in Byteflight Data Bus

  • Kwon, Jung-Hyuk;Tak, Su-Pyeong;Kwon, Ik-Hyun;Lee, Wang-Sang
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.6
    • /
    • pp.50-58
    • /
    • 2021
  • Byteflight is developed based on RS-485 communication (an international standard), and it can be used as a data bus during the operation of an integrated avionics system in the latest aircraft. Therefore, the integrated avionics system can perform an effective and safe flight mission only when the accurate and seamless display of flight information, communication, and accurate functions of navigation are implemented. In this study, cause analysis and failure investigation were performed on screen abnormalities and communication interruptions due to signal interference in the Byteflight data bus of the integrated avionics system during aircraft operation. To improve signal interference between avionics units, the branch point and wiring path of the Byteflight data bus were changed, and the verification result of the improved method was also described.

Development a Collision Accident Evaluation Indicator for an e-Navigation Service (e-Navigation 서비스를 위한 충돌사고 평가지표 개발)

  • Kim, Jeong-Ho;Bae, Sek-Han;Jang, Eun-Kyu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.1-12
    • /
    • 2021
  • The International Maritime Organization (IMO) is promoting the introduction of e-Navigation that prevents maritime accidents by fusion of Information & Communication Technology (ICT) with ship operation technology. In Korea, Korean e-Navigation is also being developed for fishing vessels and small vessels sailing offshore, which are vulnerable to maritime accidents. However, for the successful development of Korean e-Navigation, it is necessary to develop an indicator that can evaluate the development performance so that the development performance that has been progressed so far can be evaluated and the development direction can be re-established. Therefore, this study attempted to develop an evaluation index tailored to the development goal of e-Navigation service centering on the collision accident, which is a major maritime accident. In this study, a collision accident evaluation index for e-Navigation service was developed by deriving and quantifying the root cause of maritime collision accidents using Root cause analysis(RCA) and fault tree analysis (FTA) techniques. This indicator is considered to be helpful in reducing maritime accidents as it is used as a development indicator for e-Navigation and an indicator for maritime collision accident analysis.

Reliability analysis for substation based on the failure rate data the facilities (설비의 고장을 데이터를 이용한 변전소 신뢰도 분석 연구)

  • Lee, Y.H.;Baek, D.H.;Jang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.29-31
    • /
    • 2006
  • The most crucial requirement of a power system is o supply quality electric energy to customers without interrution. This problem is directly related to reliability of power system. Reliability assessment of power system has been an important topic for the past several decades. This paper deals with reliability assessment of a 154kV power substation n KEPCO. In his paper, exponential distribution is used to calculate reliablity index. The failure rate data that are utilited for reliablity index based on the realistic system. Also, FTA(Fault Tree Analysis) is used to compute substation reliablity

  • PDF