• Title/Summary/Keyword: FT

Search Result 3,799, Processing Time 0.031 seconds

The study of quantitative analysis for noxious gases of plastic materials by remote sensing open path FT-IR spectrometer (원격 측정용 개방 경로형 FT-IR spectrometer를 사용하여 플라스틱 재료의 유해 가스 정량 분석에 관한 연구)

  • Cho, Nam-Wook;Cho, Won-Bo;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.230-235
    • /
    • 2012
  • It is to use many plastic materials as living essential goods. But when the fire is happened, owing to noxious gases, many men should be injured. Therefore as the noxious gases are measured by open path FT-IR spectrometer as remote monitoring, the demage of men could be minimized. Such this system consists of a Fourier transform spectrometer and infrared lamp fitted to long length. The study was to do the quantitative analysis on CO, $NO_2$, HCl, HF gas by remote monitoring open path FT-IR spectrometer. And the method of it should use MLR (multiple linearity regression) method. As result, It was confirmed to be more than 0.95 as $R^2$ of MLR. And then Urethane and PVC of plastic materials selected was burned, the concentration of polluted gases were measured by remote monitoring method.

System Software Design and Simulation for LEON2-FT Processor based on PCI (PCI 기반 LEON2-FT 프로세서를 위한 시스템 소프트웨어 설계 및 시뮬레이션)

  • Choi, Jong-Wook;Nam, Byeong-Gyu
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.1
    • /
    • pp.54-60
    • /
    • 2013
  • The need for high performance of on-board computer (OBC) is essential due to the growing requirements and diversified missions, and so OBC has been developed on the basis of the standard design and reconfigurable modularization in order to improve the utilization of OBC for different missions. The processor in OBC of next generation satellite which is currently developed by KARI is adopted the LEON2-FT/AT697F processor based SPARC v8 as main processor and controls various devices such as SpaceWire, MIL-STD-1553B and CAN through PCI on the standardized communication chips. This paper presents the architecture and design of system software for LEON2-FT processor based on PCI, and development of PCI software component. Also it describes the porting of VxWorks 6.5 for LEON2-FT and the test under the simulation environment for LEON2-FT and PCI with communication chips.

FT의 빠른 신뢰도 계산을 위한 연구

  • 이광원;이일재
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.05a
    • /
    • pp.95-109
    • /
    • 1997
  • 보통 시스템은 신뢰도 계산을 위하여 graph나 fault tree(FT)등으로 그 시스템의 신뢰도 특성을 표현하게 된다. 전산망이나 교통망등은 보통 하나의 부품이 graph의 한선에 1:1로 대응하는 linear graph로 표현되나 화학공장이나 원자력 발전소의 신뢰성 분석을 위하여 쓰이는 FT는 보통 하나의 부품 또는 사건이 여러 곳에서 나타나는 non linear graph이다. (중략)

  • PDF

Role of FT-IR in Assessing Lubricant Degradation - A Study on Palm Oil Methyl Ester Blended Lubricant

  • Maleque, M.A.;Masjuki, H.H.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.351-352
    • /
    • 2002
  • In this paper, studies were made on the palm oil methyl ester (POME) added lubricants using FT-IR for monitoring oil degradation. In order to assess the degradation characteristics of POME added lubricant by FT-IR, static oxidation test was conducted using three different blended lubricants (viz, zero percent POME, five percent POME and ten percent POME with mineral-based oil) for 280 hrs. The oxidation temperature was set at $140^{\circ}C$. FT-IR quantitative data indicate an increased in oxidation products which was formed from 10% POME added lubricants after 280 hrs of oxidation test. The 5% POME added lubricant and mineral-based lubricant (without POME) showed less oxidation product after the test. From the FT-IR spectrum analysis of the oxidized oils it could be concluded that 5% POME can improve the performance of mineral-based oil by forming protective films.

  • PDF

Comparison of interpretation methods for large amplitude oscillatory shear response

  • Kim Hyung-Sup;Hyun Kyu;Kim Dae-Jin;Cho Kwang-Soo
    • Korea-Australia Rheology Journal
    • /
    • v.18 no.2
    • /
    • pp.91-98
    • /
    • 2006
  • We compare FT (Fourier Transform) and SD (Stress Decomposition), the interpretation methods for LAOS (Large Amplitude Oscillatory Shear). Although the two methods are equivalent in mathematics. they are significantly different in numerical procedures. Precision of FT greatly depends on sampling rate and length of data because FT of experimental data is the discrete version of Fourier integral theorem. FT inevitably involves unnecessary frequencies which must not appear in LAOS. On the other hand, SD is free from the problems from which FT suffers, because SD involves only odd harmonics of primary frequency. SD is based on two axioms on shear stress: [1] shear stress is a sufficiently smooth function of strain and its time derivatives; [2] shear stress satisfies macroscopic time-reversal symmetry. In this paper, we compared numerical aspects of the two interpretation methods for LAOS.

GeoVideo: A First Step to MediaGIS

  • Kim, Kyong-Ho;Kim, Sung-Soo;Lee, Sung-Ho;Kim, Kyoung-Ok;Lee, Jong-Hun
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.827-831
    • /
    • 2002
  • MediaGIS is a concept of tightly integrated multimedia with spatial information. VideoGIS is an example of MediaGIS focused on the interaction or interaction of video and spatial information. Our suggested GeoVideo, a new concept of VideoGIS has its key feature in interactiveness. In GeoVideo, the geographic tasks such as browsing, searching, querying, spatial analysis can be performed based on video itself. GeoVideo can have the meaning of paradigm shift from artificial, static, abstracted and graphical paradigm to natural, dynamic, real, and image-based paradigm. We discuss about the integration of video and geography and also suggest the GeoVideo system design. Several considerations on expanding the functionalities of GeoVideo are explained for the future works.

  • PDF

5ft S-Band TT&C Antenna Test

  • Ahn Sang-il;Park Dong-Chul
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.467-470
    • /
    • 2004
  • In early 2004, KARI developed 5ft S-Band TT&C antenna for especially KOMPSAT-2 operation in LEOP phase. This paper shows system features of 5ft S-Band antenna and its test result with KOMPSAT-l. Tracking test, command uplink test and telemetry downlink test were performed. Through tests, 5ft antenna was verified to be operational in uplink and downlink with KOMPSAT series. Due to its inherent wide 3dB beam-width of about 7deg at S-Band, this antenna system can be used very effectively even though orbital information is less accurate like LEOP and spacecraft safe mode.

  • PDF

Curing Reaction of Urea-formaldehyde Resin Using Real Time FT-IR Spectroscopy (실시간 FT-IR 분광분석법을 이용한 우레아-포름알데히드 수지의 경화반응)

  • Lee, Young-Kyu;Kim, Hyun-Joong
    • Journal of Adhesion and Interface
    • /
    • v.13 no.2
    • /
    • pp.85-88
    • /
    • 2012
  • In this paper, the curing reaction of UF resins was investigated by a real time FT-IR method. The curing temperature range of the UF resin was $25{\sim}200^{\circ}C$. It was found that the reactions of UF resin at different temperatures resultedin resins with different cross-linked structures. A real time FT-IR spectroscopy can be considered as a good routine analytical tool for following the progress of UF resin curing.

Determination of Water Content in Skin by using a FT Near Infrared Spectrometer

  • Suh Eun-Jung;Woo Young-Ah;Kim Hyo-Jin
    • Archives of Pharmacal Research
    • /
    • v.28 no.4
    • /
    • pp.458-462
    • /
    • 2005
  • The water content of skin was determined using a FT near infrared (NIR) spectrometer. NIR diffuse reflectance spectra were collected from hairless mouse, in vitro, and from human inner arm, in vivo. It was found that the variation of NIR absorbance band 1450 nm from OH vibration of water and 1940 nm from the combination involving OH stretching and OH deformation, depending on the absolute water content of separated hairless mouse skin, in vitro, using the FT NIR spectrometer. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed good correlation. For practical use of the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo on the basis of the relative water content of stratum corneum from the conventional capacitance method. The PLS model predicted human skin moisture with a standard errors of prediction (SEP) of 3.98 at 1130-1830 nm range. These studies showed the possibility of a rapid and nondestructive skin moisture measurement using FT NIR spectrometer.