• Title/Summary/Keyword: FSE

Search Result 84, Processing Time 0.022 seconds

Fixed-Complexity Sphere Encoder for Multi-User MIMO Systems

  • Mohaisen, Manar;Chang, Kyung-Hi
    • Journal of Communications and Networks
    • /
    • v.13 no.1
    • /
    • pp.63-69
    • /
    • 2011
  • In this paper, we propose a fixed-complexity sphere encoder (FSE) for multi-user multi-input multi-output (MU-MIMO) systems. The proposed FSE accomplishes a scalable tradeoff between performance and complexity. Also, because it has a parallel tree-search structure, the proposed encoder can be easily pipelined, leading to a tremendous reduction in the precoding latency. The complexity of the proposed encoder is also analyzed, and we propose two techniques that reduce it. Simulation and analytical results demonstrate that in a $4{\times}4$ MU-MIMO system, the proposed FSE requires only 11.5% of the computational complexity needed by the conventional QR decomposition with M-algorithm encoder (QRDM-E). Also, the encoding throughput of the proposed encoder is 7.5 times that of the QRDM-E with tolerable degradation in the BER performance, while achieving the optimum diversity order.

Modified CMA for Fractionally Spaced Linear Equalizer (Fractionally Spaced 등화기를 위한 Modified CMA)

  • 김한경;백홍기
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.601-604
    • /
    • 2000
  • 본 논문에서는 MCMA(modified constant modulus algorithm) 블라인드 등화 알고리듬을 고속 데이터 통신에 적합한 FSE(fractionally spaced equalize.)에 적용시킨 FS-MCMA를 제안하였다. 제안한 FS-MCMA는 위상 복원문제와 같은 CMA의 단점을 보완하기 위하여 M-ary QAM 신호의 경우 다중레벨로 등화하는 기존의 MCMA 이용하였고 주기 T의 간격으로 수신되는 심볼을 2배 이상으로 샘플링하는 기법, 즉 FSE를 도입하여 높은 테이터율을 요구하는 멀티미디어 통신에 적합하도록 구성하였다. 컴퓨터 모의 실험을 시행한 결과를 residual ISI 측면에서 기준을 정하고 비교하였는데 4dB정도의 성능향상을 보였으며, 또한 기존의 CMA보다 154dB 정도의 성능향상을 보였다.

  • PDF

A Study on the Convergence Characteristics Improvement of the Modified-Multiplication Free Adaptive Filer (변형 비적 적응 필터의 수렴 특성 개선에 관한 연구)

  • 김건호;윤달환;임제탁
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.6
    • /
    • pp.815-823
    • /
    • 1993
  • In this paper, the structure of modified multiplication-free adaptive filter(M-MADF) and convergence analysis are presented. To evaluate the performance of proposed M-MADF algorithm, fractionally spaced equalizer (FSE) is used. The input signals are quantized using DPCM and the reference signals is processed using a first-order linear prediction filter, and the outputs are processed by a conventional adaptive filter. The filter coefficients are updated using the Sign algorithm. Under the assumption that the primary and reference signals are zero mean, wide-sense stationary and Gaussian, theoretical results for the coefficient misalignment vector and its autocorrelation matrix of the filter are driven. The convergence properties of Sign. MADF and M-MADF algorithm for updating of the coefficients of a digital filter of the fractionally spaced equalizer (FSE) are investigated and compared with one another. The convergence properties are characterized by the steady state error and the convergence speed. It is shown that the convergence speed of M-MADF is almost same as Sign algorithm and is faster that MADF in the condition of same steady error. Especially it is very useful for high correlated signals.

  • PDF

Distinction between Intradural and Extradural Aneurysms Involving the Paraclinoid Internal Carotid Artery with T2-Weighted Three-Dimensional Fast Spin-Echo Magnetic Resonance Imaging

  • Lee, Nam;Jung, Jin-Young;Huh, Seung-Kon;Kim, Dong-Joon;Kim, Dong-Ik;Kim, Jin-Na
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.6
    • /
    • pp.437-441
    • /
    • 2010
  • Objective : The precise intra- vs. extradural localization of aneurysms involving the paraclinoid internal carotid artery is critical for the evaluation of patients being considered for aneurysm surgery. The purpose of this study was to investigate the clinical usefulness of T2-weighted threedimensional (3-D) fast spin-echo (FSE) magnetic resonance (MR) imaging in the evaluation of unruptured paraclinoid aneurysms. Methods : Twenty-eight patients with unruptured cerebral aneurysms in their paraclinoid regions were prospectively evaluated using a T2- weighted 3-D FSE MR imaging technique with oblique coronal sections. The MR images were assessed for the location of the cerebral aneurysm in relation to the dural ring and other surrounding anatomic compartments, and were also compared with the surgical or angiographic findings. Results : All 28 aneurysms were identified by T2-weighted 3D FSE MR imaging, which showed the precise anatomic relationships in regards to the subarachnoid space and the surrounding anatomic structures. Consequently, 13 aneurysms were determined to be intradural and the other 15 were deemed extradural as they were confined to the cavernous sinus. Of the 13 aneurysms with intradural locations, three superior hypophyseal artery aneurysms were found to be situated intradurally upon operation. Conclusion : High-resolution T2-weighted 3-D FSE MR imaging is capable of confirming whether a cerebral aneurysm at the paraclinoid region is intradural or extradural, because of the MR imaging's high spatial resolution. The images may help in identifying patients with intradural aneurysms who require treatment, and they also can provide valuable information in the treatment plan for paraclinoid aneurysms.

Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review (간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

Simulation and Measurement of Signal Intensity for Various Tissues near Bone Interface in 2D and 3D Neurological MR Images (2차원과 3차원 신경계 자기공명영상에서 뼈 주위에 있는 여러 조직의 신호세기 계산 및 측정)

  • Yoo, Done-Sik
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.33-40
    • /
    • 1999
  • Purpose: To simulate and measure the signal intensity of various tissues near bone interface in 2D and 3D neurological MR images. Materials and Methods: In neurological proton density (PD) weighted images, every component in the head including cerebrospinal fluid (CSF), muscle and scalp, with the exception of bone, are visualised. It is possible to acquire images in 2D or 3D. A 2D fast spin-echo (FSE) sequence is chosen for the 2D acquisition and a 3D gradient-echo (GE) sequence is chosen for the 3D acquisition. To find out the signal intensities of CSF, muscle and fat (or scalp) for the 2D spin-echo(SE) and 3D gradient-echo (GE) imaging sequences, the theoretical signal intensities for 2D SE and 3D GE were calculated. For the 2D fast spin-echo (FSE) sequence, to produce the PD weighted image, long TR (4000 ms) and short TE$_{eff}$ (22 ms) were employed. For the 3D GE sequence, low flip angle (8$^{\circ}$) with short TR (35 ms) and short TE (3 ms) was used to produce the PD weighted contrast. Results: The 2D FSE sequence has CSF, muscle and scalp with superior image contrast and SNR of 39 - 57 while the 3D GE sequence has CSF, muscle and scalp with broadly similar image contrast and SNR of 26 - 33. SNR in the FSE image were better than those in the GE image and the skull edges appeared very clearly in the FSE image due to the edge enhancement effect in the FSE sequence. Furthermore, the contrast between CSF, muscle and scalp in the 2D FSE image was significantly better than in the 3D GE image, due to the strong signal intensities (or SNR) from CSF, muscle and scalp and enhanced edges of CSF. Conclusion: The signal intensity of various tissues near bone interface in neurological MR images has been simulated and measured. Both the simulation and imaging of the 2D SE and 3D GE sequences have CSF, fat and muscle with broadly similar image intensity and SNR's and have succeeded in getting all tissues about the same signal. However, in the 2D FSE sequence, image contrast between CSF, muscle and scalp was good and SNR was relatively high, imaging time was relatively short.

  • PDF

Combined Effect of Fermentation and Extrusion Process on Antioxidant Properties of Sangmaksan (압출성형 공정을 이용한 발효 생맥산의 항산화 활성)

  • Yang, Hye-Jin;Ryu, Gi-Hyung
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.5
    • /
    • pp.566-571
    • /
    • 2009
  • The principal objective of this study was to use a fermentation and extrusion process in order to improve the antioxidant properties of original Sangmaksan (ES), containing maekmoondong, omija, and white ginseng. The antioxidant activities of fermented Sangmaksan prepared with different types of ginseng [white (FSW), red (FSR), and extruded white (FSE)], were investigated. The white ginseng powder was extruded at 20% moisture content and $120^{\circ}C$ of the maximum process temperature at the barrel. The antioxidant properties of Sangmaksan were increased after fermentation. Interestingly, the fermented Sangmaksan containing the extruded white ginseng evidenced more potent antioxidant properties than the fermented Sangmaksan containing white ginseng. The content of total phenolic compounds, DPPH-radical scavenging activity, acidic polysaccharide, reducing power, and total anthocyanin were highest with FSR, followed by FSE, FSW and ES, respectively. Additionally, superoxide dismutase-like activity and total flavonoid contents were highest in the fermented Sangmaksan containing extruded white ginseng. In conclusion, it can be asserted that the fermentation and extrusion process utilized in this study may prove to be an effective new process for the production of high-quality Sangmaksan.

Effectiveness of a fast spin echo technique using the signal void in acquisition of black blood images (흑혈류영상 획득 시 신호소실을 활용한 고속스핀에코기법의 유용성)

  • Choi, Kwan-Woo;Kim, Yoon-Shin;Son, Soon-Yong;Lee, Hee-Ju;Min, Jung-Whan;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4313-4319
    • /
    • 2013
  • The purpose of our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images using the signal void effect in the fast spin echo technique while keeping the diagnostic value of the test. Thirty-two consecutive patients who underwent black blood MR imaging were examed with additional double inversion recovery (DIR) sequence and the conventional fast spin echo (FSE) sequence. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images to determine whether there are differences between the two techniques for depiction of the signal void effect inside the vessel wall. The FSE images showed lower SNR values than the DIR images in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the FSE images than in the DIR images in both of the T1 and T2 weighted images (8.69% and 7.55% respectively).There was no significant difference between the two techniques for either of the SNR or CNR (p>0.05, p>0.05 respectively). The DIR and the FSE images demonstrated almost identical imaging patterns. Therefore, it is anticipated that the use of FSE technique in acquisition of the black blood imaging could reduce the inconveniences of the patients during the scanning and minimize exam time while keeping the diagnostic value of the test.