• 제목/요약/키워드: FRP sheets

검색결과 128건 처리시간 0.023초

실험에 의한 피로하중을 받는 FRP패널 보강 RC보의 부착성능 (The Bond Performance of RC Beams Strengrhened for FRP Pannel deal with Fatigue Loadings through Experiments)

  • 이창규;정영배
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권3호
    • /
    • pp.105-115
    • /
    • 2007
  • 리모델링의 증가로 보수보강에 대하여 많은 관심을 갖게 되었다. 탄소섬유시트의 사용은 철근콘크리트 구조의 강성을 증가시키기 위하여 많이 쓰이고 있다. 따라서 새로운 보강방법으로 외부 부착에 의한 강성이 증가된 RC구조의 휨거동을 알아보기 위하여 실험과 분석 연구를 수행하였다. 또한 본 연구는 실험에 의한 피로하중을 받도록 한 FRP패널 보강방법에 대하여 살펴보는데 그 목적이 있다.

섬유보강 철근콘크리트 보의 전단강도에 대한 실험적 연구 (An Experimental Study on Shear Strength of Reinforced Concrete Beams Strengthened by Fiber Reinforced Polymer)

  • 황현복;이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.371-374
    • /
    • 2005
  • The research reported in this paper provides the test results of eleven reinforced concrete beams strengthened with FRP composites. Three parameters were considered in this investigation: the amount of FRP composites, the types of bonding schemes(continuous sheets or strips), and the material types of FRP composites (Carbon or Glass). The experimental results indicated that because the rupture strain of FRP composites was relatively higher that the yield strain of steel bars, the RC beams strengthened with FRP composites failed due to concrete crushing before the FRP composites arrived at its rupture strain. The compatibility-aided truss model showed reasonable agreement between the predicted and experimental shear stress-strain curves of the beams throughout the entire loading history.

  • PDF

Effectiveness of different confining configurations of FRP jackets for concrete columns

  • Moretti, Marina L.
    • Structural Engineering and Mechanics
    • /
    • 제72권2호
    • /
    • pp.155-168
    • /
    • 2019
  • This paper presents the results of an experimental investigation on the compressive strength of small scale concentrically axially loaded fiber-reinforced polymer (FRP) confined plain concrete columns, with cylinder concrete strength 19 MPa. For columns with circular (150-mm diameter) and square (150-mm side) cross sections wrapped with glass- and carbon-FRP sheets (GFRP and CFRP, respectively) applied with dry lay-up the effect of different jacket schemes and different overlap configurations on the confined characteristics is investigated. Test results indicate that the most cost effective jacket configuration among those tested is for one layer of CFRP, for both types of sections. In square sections the location of the lap length, either in the corner or along the side, does not seem to affect the confined performance. Furthermore, in circular sections, the presence of an extra wrap with FRP fibers parallel to the column's axis enhances the concrete strength proportionally to the axial rigidity of the FRP jacket. The recorded strains and the distributions of lateral confining pressures are discussed. Existing design equations are used to assess the lateral confining stresses and the confined concrete strength making use of the measured hoop strains.

BFRP 보강이 직사각형 단면 철근콘크리트 기둥의 지진거동에 미치는 영향 (Effect of BFRP Wrapping on Seismic Behavior of Rectangular RC Columns)

  • 이혜린;조정현;이승건;이수형;홍기증
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.153-160
    • /
    • 2020
  • 지진동 하의 구조 시스템에서 기둥은 가장 중요한 구조 요소 중 하나이다. 이러한 관계로, 철근콘크리트(RC) 기둥의 내진 성능에 FRP 보강이 미치는 영행을 평가하기 위하여 광범위한 실험 연구가 이루어졌다. 이 중 상당수는 CFRP 또는 GFRP로 보강된 원형 단면 또는 정사각형 단면의 RC 기둥의 지진 거동에 집중하였다. 단면의 형태가 FRP 보강으로 인한 구속 효과에 영향을 미치기 때문에, 보강 효과와 최종 파괴 패턴이 형상에 따라 상이할 수 있다. 본 연구에서는 현무암 섬유를 함유한 BFRP 시트와 복합섬유 패널로 보강한 직사각형 단면을 가진 RC 기둥의 지진 거동을 살펴보기 위하여 반복하중 실험을 수행하였다. 실험 결과는 보강 효과가 크지 않았음을 보여주는데, BFRP 시트와 복합섬유 패널에 의한 구속 효과의 증가가 미미했음을 의미하며, 이는 기둥 단면 형상에 일부 기인하는 것으로 판단된다.

Strength and strain enhancements of concrete columns confined with FRP sheets

  • Campione, G.;Miraglia, N.;Papia, M.
    • Structural Engineering and Mechanics
    • /
    • 제18권6호
    • /
    • pp.769-790
    • /
    • 2004
  • The compressive behavior up to failure of short concrete members reinforced with fiber reinforced plastic (FRP) is investigated. Rectangular cross-sections are analysed by means of a simplified elastic model, able also to explain stress-concentration. The model allows one to evaluate the equivalent uniform confining pressure in ultimate conditions referred to the effective confined cross-section and to the effective stresses in FRP along the sides of section; consequently, it makes it possible to determine ultimate strain and the related bearing capacity of the confined member corresponding to FRP failure. The effect of local reinforcements constitute by single strips applied at corners before the continuous wrapping and the effect of round corners are also considered. Analytical results are compared to experimental values available in the literature.

유리섬유쉬트로 전단보강된 저강도 RC보의 전단강도 (Shear Strength of Low-Strength RC Beams Strengthened with Glass Fiber Sheets)

  • 유영찬;최기선;김도겸;류금성;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.283-286
    • /
    • 2005
  • The effectiveness of shear strengthening with glass fiber sheets on normal or low strength RC beams have been investigated experimentally. A design compressive strength of concrete of 13.5MPa has been planned considering the degradation state of the existing structure to be strengthened in this study. Also, concrete surface reinforcing agent was applied to increase bond capacity between concrete and GFRP sheets in case of low strength RC beams. Comparing the test results of low and normal strength beams strengthened with GFRP sheets indicated that total shear capacity of beams was decreased with concrete strength decreased, but the shear strengthening capacity of GFRP sheets are hardly affected by concrete strength. In addition, shear strengthening effects of RC beams strengthened with GFRP sheets can be estimated by $\rho_w{\cdot}f_w$ based on the maximum effective strain of FRP sheet proposed by ACI 440.2R recommendation.

  • PDF

An experimental investigation on effect of elevated temperatures on bond strength between externally bonded CFRP and concrete

  • Attari, Behzad;Tavakkolizadeh, Mohammadreza
    • Steel and Composite Structures
    • /
    • 제32권5호
    • /
    • pp.559-569
    • /
    • 2019
  • The bond strength between composite laminates and concrete is a key factor that controls the behavior of concrete members strengthened with fiber reinforced polymer (FRP) sheets, which can be affected by several parameters such as thermal stresses and surface preparation. This article presents the result of an experimental study on the bond strength between FRP sheets and concrete at ambient temperature after specimens had been exposed to elevated temperatures of up to $200^{\circ}C$. For this purpose, 30 specimens of plain concrete with dimensions of $150{\times}150{\times}350mm$ were prepared. Three different conventional surface preparation methods (sandblasting, wire brushing and hole drilling) were considered and compared with a new efficient method (fiber implantation). Deformation field during each experiment was monitored using particle image velocimetry. The results showed that, the specimens which were prepared by conventional surface preparation methods, preserved their bond integrity when exposed to temperature below glass transition temperature of epoxy resin (about $60^{\circ}C$). Beyond this temperature, the bond strength and stiffness decreased significantly (about 50%) in comparison with control specimens. However, the specimens prepared by the proposed method displayed higher bond strengths of up to 32% and 90% at $25^{\circ}C$ and $200^{\circ}C$, respectively.

Intermediate crack-induced debonding analysis for RC beams strengthened with FRP plates

  • Wantanasiri, Peelak;Lenwari, Akhrawat
    • Structural Engineering and Mechanics
    • /
    • 제56권3호
    • /
    • pp.473-490
    • /
    • 2015
  • This paper presents the analysis of intermediate crack-induced (IC) debonding failure loads for reinforced concrete (RC) beams strengthened with adhesively-bonded fiber-reinforced polymer (FRP) plates or sheets. The analysis consists of the energy release and simple ACI methods. In the energy release method, a fracture criterion is employed to predict the debonding loads. The interfacial fracture energy that indicates the resistance to debonding is related to the bond-slip relationships obtained from the shear test of FRP-to-concrete bonded joints. The section analysis that considers the effect of concrete's tension stiffening is employed to develop the moment-curvature relationships of the FRP-strengthened sections. In the ACI method, the onset of debonding is assumed when the FRP strain reaches the debonding strain limit. The tension stiffening effect is neglected in developing a moment-curvature relationship. For a comparison purpose, both methods are used to numerically investigate the effects of relevant parameters on the IC debonding failure loads. The results show that the debonding failure load generally increases as the concrete compressive strength, FRP reinforcement ratio, FRP elastic modulus and steel reinforcement ratio increase.

FRP로 보강된 RC보의 전단보강효과 비교연구 (A Comparative Study on the Shear-Strengthening Effect of RC Beams Strengthened by FRP)

  • 심종성;김규선
    • 콘크리트학회지
    • /
    • 제10권4호
    • /
    • pp.101-111
    • /
    • 1998
  • 본 논문의 목적은 전단내력이 부족한 R/C보에 CFS(Carbon Fiber Sheets), CFRP(Carbon Fiber Reinforced Plastic), GFRP(Glass Fiber Reinforced Plastics)를 이용해 전단보강을 할 경우에 보의 역학적 거동특성을 규명하기 위한 것이다. 본 논문의 목적을 달성하기 위하여 총 19개의 시험체가 제작되었으며, 실험변수로는 전단스팬비, 보강재료, 보강방법, 보강간격 및 방향을 산정하였다. 본 논문의 실험결과, FRP를 이용해 전단내력이 부족한 R/C보에 보강을 하였을 경우 약 50~70%정도의 보강효과를 나타내었다. 또한 소성이론에 근거한 철근콘크리트보의 전단강도 예측모델을 개발하였고 실험치와의 비교를 통해 개발된 모델의 적합성을 검증하였다.

Utilizing vacuum bagging process to enhance bond strength between FRP sheets and concrete

  • Abdelal, Nisrin R.;Irshidat, Mohammad R.
    • Structural Engineering and Mechanics
    • /
    • 제72권3호
    • /
    • pp.305-312
    • /
    • 2019
  • This paper investigates the effect of utilizing vacuum bagging process to enhance the bond behavior between fiber reinforced polymer (FRP) composites and concrete substrate. Sixty specimens were prepared and tested using double-shear bond test. The effect of various parameters such as vacuum, fiber type, and FRP sheet length and width on the bond strength were investigated. The experimental results revealed that utilizing vacuum leads to improve the bond behavior between FRP composites and concrete. Both the ultimate bond forces and the maximum displacements were enhanced when applying the vacuum which leads to reduction in the amount of FRP materials needed to achieve the required bond strength compared with the un-vacuumed specimens. The efficiency of the enhancement in bond behavior due to vacuum highly depends on the fiber type; using carbon fiber showed higher enhancement in the bond strength compared to the glass fiber when vacuum was applied. On the contrary, specimens with glass fiber showed higher enhancement in the maximum slippage compared to specimens with carbon fibers. Utilizing vacuum does not affect the debonding failure modes but lead to increase in the amount of attached concrete on the surface of the debonded FRP sheet.