• Title/Summary/Keyword: FRP concrete

Search Result 751, Processing Time 0.029 seconds

Development of Hybrid Fiber Reinforced Polymer Reinforcing Bars and Evaluation of the Bond Properties (하이브리드 FRP 보강근의 형상개발과 부착성능 평가)

  • Park, Ji-Sun;Park, Young-Hwan;You, Young-Jun;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.629-632
    • /
    • 2006
  • The various rib geometry of hybrid fiber reinforced polymer (FRP) reinforcing bars were analyzed by finite element method. From the analysis result, two types of hybrid FRP reinforcing bars such as spiral and cross type with the same dimension of rib geometry were fabricated in this study. To evaluate the bond properties of them, direct pull-out test was performed. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made in accordance with the recommendations of CSA Standard S806-02. From the test results, it was found that cross type hybrid FRP reinforcing bars showed the highest bond strength than that of the others due to the higher relative rib area.

  • PDF

An Analytical Model for FRP Debonding in Strengthened RC Beams under Monotonic and Cyclic Loads

  • Moein, Reza Saeidi;Tasnimi, Abbas Ali
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.4
    • /
    • pp.499-511
    • /
    • 2016
  • Reinforced concrete (RC) beams strengthened by externally bonded reinforcement often fail by debonding. This paper presents an experimental and analytical study aimed at better understanding and modeling the fiber reinforced polymer (FRP) debonding failures in strengthened RC beams under monotonic and cyclic loads. In order to investigate the flexural behavior and failure modes of FRP-strengthened beams under monotonic and cyclic loadings, an experimental program was carried out. An analytical study based on the energy balance of the system was also performed. It considers the dominant mechanisms of energy dissipation during debonding and predicts the failure load of the strengthened beams. Validation of the model was carried out using test data obtained from the own experimental investigation.

Fatigue behaviors on the reinforced concrete beam strengthened with FRP (FRP 보강 RC보의 피로거동)

  • Kim, Jae-Young;Kim, Chung-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.505-506
    • /
    • 2009
  • This paper is an investigation of the fatigue behaviors on the GFRP bar and GSP embedded method as repair and reinforced method. In the experiments, the stress ratio R is 0.1 and loading frequency is 1.5 Hz. As a result of fatigue test, the fatigue strengths of the GFRP bar and GSP reinforced beams were 58%, 52% of the static strength in S-N curve.

  • PDF

Analytical Study of Reinforced Concrete Beams Strengthened with Fiber Reinforced Plastic Laminates (적층판으로 보강된 철근콘크리트보에 대한 해석적 연구)

  • Chae, Seoung-Hun;Kang, Joo-Won
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2004.05a
    • /
    • pp.206-211
    • /
    • 2004
  • This paper deals with the flexural strengthening of reinforced concrete beams by means of thin fiber reinforced plastic(FRP) laminas. This study focuses on modeling of structural of concrete bonded FRP laminate in flexural bending members. Used computational equation is derived by relation of stress and strain. The section analysis is based on experimental observations of a linear strain distribution in the cross section until failure, and a multi-linear moment-deflection curve that is divided into four regions, each terminated by a similarly numbered point. The load-deflection relationship in each region is assumed to be linear. The present model is validated to compare wit the experiment of 4-point bending tests of R/C rectangular beams strengthened with CFRP laminates, and has well predicted the moment-displacement relationships of members.

  • PDF

Reinforced high-strength concrete square columns confined by aramid FRP jackets -part II: modeling

  • Wu, Han-Liang;Wang, Yuan-Feng;Ma, Yi-Shuo
    • Steel and Composite Structures
    • /
    • v.11 no.4
    • /
    • pp.325-340
    • /
    • 2011
  • Based on the experimental data presented in part I of these companion papers, a semi-empirical model is proposed for axial stress-strain curves of reinforced high-strength concrete square columns confined by aramid fiber reinforced polymer (FRP) jackets. Additionally, a three-dimensional finite element model is developed to simulate the mechanical behaviors of the columns. In the finite element model, both material nonlinear and contact nonlinear are taken into account. Moreover, the influence of contact nonlinear (i.e., the end friction on the contact surface between test machines and specimens) is investigated deeply. Predictions from both the semi-empirical model and the finite element model agree with the experimental results, and it is also demonstrated that the friction coefficient of end friction notably affect the properties of columns when it ranges from 0.00 to 0.25.

Experiment for the Improvement of Fire Resistance Capacity of Reinforced Concrete Flexural Member Strengthened with Carbon Fiber Reinforced Polymer (CFRP로 보강된 철근콘크리트 휨부재의 내화성능 개선을 위한 실험)

  • Lim, Jong-Wook;Seo, Soo-yeon;Song, Se-Ki
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.19-27
    • /
    • 2017
  • This paper is a study to improve the fire-resistance capacity of reinforced concrete (RC) members strengthened by fiber-reinforced-polymer (FRP). The fire resistance of the RC members strengthened by FRP was evaluated through high temperature exposure test. In order to improve the fire resistance of the FRP reinforcing method, a fire-proof board was attached to the reinforced FRP surface and then the high temperature exposure test was carried out to evaluate the improvement of the fire resistance performance. It was confirmed that the resistance to high temperature of NSMR could be improved somewhat compared with that of EBR from the experiment that exposed to high temperature under the load corresponding to 40% of nominal strength. When 30 mm thick fire-resistance (FR) board is attached to the FRP surface, the surface of the reinforced FRP does not reach $65^{\circ}C$, which is the glass transition temperature (GTT) of the epoxy until the external temperature reaches $480^{\circ}C$. In particular, when a high performance fire-proof mortar was first applied prior to FR board attachment, the FRP portion did not reach the epoxy glass transition temperature until the external temperature reached $600^{\circ}C$.

Improvement and Evaluation of Seismic Performance for Reinforced Concrete Beam-Column Joints Using High Performance Embedded FRP (고성능 FRP를 활용한 철근콘크리트 보-기둥 접합부의 내진 성능 평가 및 개선)

  • Ha, Gee-Joo;Shin, Jong-Hack;Kang, Hyun-Wook
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.385-392
    • /
    • 2011
  • In this study, experimental research was carried out to evaluate and improve the seismic performance of reinforced concrete beam-column joint regions using strengthening materials (steel plate, carbon fiber sheet, and embedded carbon fiber rod) in existing reinforced concrete buildings. Six specimens of retrofitted beam-column joints are constructed using various retrofitting materials and tested for their retrofit performances. Specimens designed by retrofitting the beam-column joint regions (LBCJ series) of existing reinforced concrete building showed a stable mode of failure and an increase in load-carrying capacity due to the effect of crack control at the time of initial loading and confinement from retrofitting materials during testing. Specimens of LBCJ series, designed by the retrofitting of FRP in reinforecd beam-column joint regions increased its maximum load carrying capacity by 26~50% and its energy dissipation capacity by 13.0~14.4% when compared to standard specimen of LBCJC with a displacement ductility of 4.