• Title/Summary/Keyword: FREQUENCY ANALYSIS

Search Result 23,624, Processing Time 0.04 seconds

Creep Damage Evaluation of High-Temperature Pipeline Material for Fossil Power Plant by Ultrasonic Frequency Analysis Spectrum Method (초음파 주파수분석법에 의한 발전소 고온배관재료의 크리프손상 평가)

  • Chung, Min-Hwa;Lee, Sang-Guk
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.90-98
    • /
    • 1999
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operationg conditions like high temperature and high pressure for an extended period time. Such material degradation lead to various component faliures causing serious accidents at the plant. Conventional measurement techniques such as replica method, electric resistance method, and hardness test method have such disadvantages as complex preparation and measurement procedures, too many control parameters, and therefore, low practicality and they were applied only to component surfaces with good accessibility. In this study, both artificial creep degradation test using life prediction formula and frequency analysis by ultrasonic tests for their preparing creep degraded specimens have been carried out for the purpose of nondestructive evaluation for creep damage which can occur in high-temperature pipelline of fossil power plant. As a result of ultrasonic tests for crept specimens, we confirmed that the high frequency side spectra decrease and central frequency components shift to low frequency bans, and bandwiths decrease as increasing creep damage in backwall echoes.

  • PDF

Transient Vibration Analysis of an Agricultural Tractor (농업용 트랙터의 과도 진동 분석)

  • 김용준;김경욱
    • Journal of Biosystems Engineering
    • /
    • v.26 no.6
    • /
    • pp.509-516
    • /
    • 2001
  • This paper introduced some advantages of the time-frequency analysis of vibration and investigated, using the time-frequency transform, the characteristics of the transient motion of a tractor seat, which occurred during the tractor traversed over a rectangular obstacle on the flat surface. The characteristics of the short-time courier and wavelet transforms as time-frequency analysis methods were introduced and discussed to figure out which is more suitable to the analysis of the transient motions of agricultural tractors. Using each transform, transient vibration of a tractor seat was analyzed. Results of the analysis showed that the transient vibration of the seat was influenced by the natural frequencies of vertical mode of chassis, pitching mode of engine and pitching mode of cab of the tractor. The time sequence of the natural mode of tractor vibration was also revealed by the time-frequency analysis. The vibration path analysis by the time-frequency transform showed that the vibration energies transmitted from the front mounts to the seat were less than those from the rear mounts. The energy reduction ratios between the cab mounts and seat were also estimated to be about 72∼78%. The front mounts showed larger reduction than the rear mounts. However, the reduction difference between the right and left sides mounts was negligibly small. The short time Fourier transform was found to be a proper method for investigating the transient motions of farm machines and their effects on the ride vibration.

  • PDF

Obstructive Sleep Apnea Analysis Based on Heart Rate Variability (폐쇄성 수면 무호흡 검출을 위한 심박동변이율 분석)

  • Ye, Soo-Young;Kim, Jung-Guk;Kim, Dong-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.7
    • /
    • pp.605-608
    • /
    • 2011
  • In this study, OSA (the obstructive sleep apnea) periods were detected in patients with OSA during sleep because of the treatment was different according to the frequency and symptoms of obstructive sleep apnea. ANS (autonomic nervous activity) was changed by obstructive sleep apnea periods so we intended to detect the periods to care the obstructive sleep apnea patients. RR intervals, SDNN (standard deviation of normal to normal) and RMSSD (root mean square standard deviation) were calculated in time domain analysis and LF (low frequency), HF (high frequency), NHF (normalized high frequency), NLF (normalized low frequency) were calculated in frequency domain analysis of HRV (heart rate variability) with obstructive sleep apnea patients. In this paper, SDNN (standard deviation of normal to normal) of time domain analysis were decreased in the obstructive sleep apnea periods. And NLF and LF/HF ratio were increased and NHF (normalized high frequency) was decreased in the frequency domain analysis. The parameters can be used to treat obstructive sleep apnea patients by detecting the obstructive sleep apnea periods such as CPAP (continuous positive airway pressure).

Analysis of the effect of Digital frequency synthesizer in FSK-Frequency-hopped data communications (FSK-주파수 도약 데이터 통신시스템에서의 디지털 주파수 합성기의 영향분석)

  • 송인근
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.879-886
    • /
    • 2003
  • Agile frequency synthesizers are the common device used for commandable, wide-band frequency hopping in frequency-hopped (FH) communications. In this paper, synthesizer phase transient effect and its compensation methods in an FH/FSK(Frequency Hopped Frequency Shift Keying) system are studied. Models for these analysis are developed and resulting performance degradations are computed. The basic PLL is difficult to implement for fast frequency hopping in narrowband radio communication systems. To solve this problem, digital frequency synthesizer/CPM (Continuous Phase Modulation)modulator is proposed. And it's performance is analyzed theoretically. The analysis show that fast frequency hopping is possible in frequency hopping system that use digital frequency synthesizer/CPM modulator.

Regional Drought Frequency Analysis of Monthly Precipitation with L-Moments Method in Nakdong River Basin (L-Moments법에 의한 낙동강유역 월강우량의 지역가뭄빈도해석)

  • 김성원
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.431-441
    • /
    • 1999
  • In this study, the regional frequency analysis is used to determine each subbasin drought frequency with reliable monthly precipitation and the L-Moments method which is almost unbiased and has very nearly a normal distribution is used for the parameter estimation of monthly precipitation time series in Nakdong river basin. As the result of this study, the duration of '93-'94 is most severe drought year than any other water year and the drought frequency is established as compared the regional frequency analysis result of cumulative precipitation of 12th duration months in each subbasin with that of 12th duration months in the major drought duration. The Linear regression equation is induced according to linear regression analysis of drought frequency between Nakdong total basin and each subbasin of the same drought duration. Therefore, as the foundation of this study, it can be applied proposed method and procedure of this study to the water budget analysis considering safety standards for the design of impounding facilities large-scale river basin and for this purpose, above all, it is considered that expansion of reliable preciptation data is needed in watershed rainfall station.

  • PDF

Estimation of Chest Compression Depth during Cardiopulmonary Resuscitation by using Single Frequency Analysis (단일주파수분석을 이용한 심폐소생술 흉부압박깊이 추정)

  • U, One Sang;Kang, Seong Min;Choi, Seong Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.211-217
    • /
    • 2017
  • During the emergency situation such as cardiac arrest, cardiopulmonary resuscitation(CPR) is the most important treatment to maintain patient's blood circulation. Since the quality of CPR can not be easily measured or evaluated by the eye, an assistive device with an accelerometer can help to assess the pressure depth of CPR. In this study, we propose a single frequency analysis method to reduce the error of the accelerometer by extracting only one frequency component from the Fourier transform process. To verify the effectiveness of the single frequency analysis, acceleration data at CPR conditions were measured at a sampling rate of 50 / sec using a wristband equipped with an acceleration sensor. Then, We compared the existing distance estimation method and the single frequency analysis method using the measured data. The amplitude value proportional to the compression depth was obtained by applying the single frequency analysis method.

Verification of Frequency-Dependent Equivalent Linear Method (주파수 의존성을 고려한 등가선형해석기법의 검증)

  • Jeong, Chang-Gyun;Kwak, Dong-Yeop;Park, Du-Hee
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.12
    • /
    • pp.113-120
    • /
    • 2008
  • One-dimensional site response analysis is widely used to simulate the seismic site effects. The equivalent linear analysis, which is the most widely used type of site response analysis, is essentially a linear method. The method applies constant shear modulus and damping throughout the frequency range of the input motion, ignoring the dependence of the soil response on the loading frequency. A new type of equivalent linear analysis method that can simulate the frequency dependence of the soil behavior via frequency-strain curve was developed. Various forms of frequency-strain curves were proposed, and all curves were asserted to increase the accuracy of the solution. However, its validity has not been extensively proven and the effect of the shape of the frequency-strain curve is not known. This paper used two previously proposed frequency-strain curves and three additional curves developed in this study to evaluate the accuracy of the frequency-dependent equivalent linear method and the influence of the shape of the frequency-strain curves. In the evaluation, six recordings from three case histories were used. The results of the case study indicated that the shape of the frequency-strain curve has a dominant influence on the calculated response, and that the frequency dependent analysis can enhance the accuracy of the solution. However, a curve that results in the best match for all case histories did not exist and the optimum curve varied for each case. Since the optimum frequency-strain curve can not be defined, it is recommended that a suite of curves be used in the analysis.

The Frequency Characteristics of Elastic Wave by Crack Propagation of SiC/SiC Composites

  • Kim, J.W.;Nam, K.W.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.110-114
    • /
    • 2012
  • We studied on the nondestructive evaluation of the elastic wave signal of SiC ceramics and SiC/SiC composite ceramics under monotonic tensile loading. The elastic wave signal of cross and unidirectional SiC/SiC composite ceramics were obtained by pencil lead method and bending test. It was applied for the time-frequency method which used by the discrete wavelet analysis algorithm. The time-frequency analysis provides time variation of each frequency component involved in a waveform, which makes it possible to evaluate the contribution of SiC fiber frequency. The results were compared with the characteristic of frequency group from SiC slurry and fiber. Based on the results, if it is possible to shift up and design as a higher frequency group, we will can make the superior material better than those of exiting SiC/SiC composites.

  • PDF

Model Order Reduction for Mid-Frequency Response Analysis (중주파수 응답해석을 위한 축소 기법)

  • Ko, Jin-Hwan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.135-138
    • /
    • 2009
  • Most of the studies use model order reduction for low frequency (LF) response analysis due to their high computational efficiency. In LF response analysis, one of model order reduction, algebraic substructuring (AS) retains all LF modes when using the modal superposition. However, in mid-frequency (MF) response analysis, the LF modes make very little contribution and also increase the number of retained modes, which leads to loss of computational efficiency. Therefore, MF response analysis should consider low truncated modes to improve the computational efficiency. The current work is focused on improving the computational efficiency using a AS and a frequency sweep algorithm. Finite element simulation for a MEMS resonator array showed that the performance of the presented method is superior to a conventional method.

  • PDF

Analysis of Current Control Stability using PI Control in Synchronous Reference Frame for Grid-Connected Inverter with LCL Filter (LCL 필터를 사용하는 계통연계형 인버터의 동기좌표계 PI 전류제어 안정도 해석)

  • Jo, Jongmin;Lee, Taejin;Yun, Donghyun;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.2
    • /
    • pp.168-174
    • /
    • 2016
  • In this paper, current control using PI controller in the synchronous reference frame is analyzed through the relationship among bandwidth, resonance frequency, and sampling frequency in the grid-connected inverter with LCL filter. Stability is investigated by using bode plot in frequency domain and root locus in discrete domain. The feedback variable is the grid current, which is regulated by the PI controller in the synchronous reference frame. System delay is modeled as 1.5Ts, which contains computational and PWM modulator delay. Two resonance frequencies are given at 815 Hz and 3.16 kHz from LCL filter parameters. Sufficient phase and gain margins can be obtained to guarantee stable current control, in case that resonance frequency is above one-sixth of the sampling frequency. Unstable current control is performed when resonance frequency is below one-sixth of the sampling frequency. Analysis results of stability from frequency response and discrete response is the same regardless of resonance frequency. Finally, stability of current control based on theoretical analysis is clearly verified through simulation and experiment in grid-connected inverters with LCL filter.