• Title/Summary/Keyword: FPI

Search Result 84, Processing Time 0.023 seconds

Seismic evaluation and retrofitting of reinforced concrete buildings with base isolation systems

  • Vasiliadis, Lazaros K.
    • Earthquakes and Structures
    • /
    • v.10 no.2
    • /
    • pp.293-311
    • /
    • 2016
  • A parametric study on the nonlinear seismic response of isolated reinforced concrete structural frame is presented. Three prototype frames designed according to the 1954 Hellenic seismic code, with number of floor ranging from 1 to 3 were considered. These low rise frames are representative of many existing reinforced concrete buildings in Greece. The efficacy of the implementation of both lead rubber bearings (LRB) and friction pendulum isolators (FPI) base isolation systems were examined. The selection of the isolation devices was made according to the ratio $T_{is}/T_{fb}$, where Tis is the period of the base isolation system and $T_{bf}$ is the period of the fixed-base building. The main purpose of this comprehensive study is to investigate the effect of the isolation system period on the seismic response of inadequately designed low rise buildings. Thus, the implementation of isolation systems which correspond to the ratio $T_{is}/T_{fb}$ that values from 3 to 5 is studied. Nonlinear time history analyses were performed to investigate the response of the isolated structures using a set of three natural seismic ground motions. The evaluation of each retrofitting case was made in terms of storey drift and storey shear force while in view of serviceability it was made in terms of storey acceleration. Finally, the maximum developed displacements and the residual displacements of the isolation systems are presented.

Ground-based Observations for the Upper Atmosphere at King Sejong Station, Antarctica

  • Jee, Geonhwa;Kim, Jeong-Han;Lee, Changsup;Kim, Yong Ha
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.169-176
    • /
    • 2014
  • Since the operation of the King Sejong Station (KSS) started in Antarctic Peninsula in 1989, there have been continuous efforts to perform the observation for the upper atmosphere. The observations during the initial period of the station include Fabry-Perot Interferometer (FPI) and Michelson Interferometer for the mesosphere and thermosphere, which are no longer in operation. In 2002, in collaboration with York University, Canada, the Spectral Airglow Temperature Imager (SATI) was installed to observe the temperature in the mesosphere and lower thermosphere (MLT) region and it has still been producing the mesopause temperature data until present. The observation was extended by installing the meteor radar in 2007 to observe the neutral winds and temperature in the MLT region during the day and night in collaboration with Chungnam National University. We also installed the all sky camera in 2008 to observe the wave structures in the MLT region. All these observations are utilized to study on the physical characteristics of the MLT region and also on the wave phenomena such as the tide and gravity wave in the upper atmosphere over KSS that is well known for the strong gravity wave activity. In this article, brief introductions for the currently operating instruments at KSS will be presented with their applications for the study of the upper atmosphere.

Pool Boiling Heat Transfer Coefficients of R1234yf on Various Enhanced Surfaces (열전달 촉진 표면에서 R1234yf의 풀 비등 열전달계수)

  • Lee, Yohan;Kang, Dong Gyu;Seo, Hoon;Jung, Dongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.143-149
    • /
    • 2013
  • In this work, nucleate pool boiling heat transfer coefficients (HTCs) of R134a and R1234yf are measured, on flat plain, 26 fpi low fin, Turbo-B, Turbo-C and Thermoexcel-E surfaces. All data are taken at the liquid pool temperature of $7^{\circ}C$, on a small square copper plate ($9.53mm{\times}9.53mm$), at heat fluxes from $10kW/m^2$ to $200kW/m^2$, with an interval of $10kW/m^2$. Test results show that nucleate boiling HTCs of all enhanced surfaces are greatly improved, as compared to that of a plain surface. Nucleate pool boiling HTCs of R1234yf are very similar to those of R134a, for the five surfaces tested.

Pool Boiling Heat Transfer Characteristics of R-l34a in Titanium Horizontal Plain and Low Finned Tubes (티타늄 평활관 및 전열촉진관에서 R-l34a의 관외측 풀비등 열전달 특성에 대한 연구)

  • Heo Jae-Hyeok;Yun Rin;Chung Jin-Taek;Moon Young-lune;Kim Yongchan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.854-860
    • /
    • 2005
  • Pool boiling heat transfer characteristics of R-134a were investigated in titanium plain and low finned tubes. The diameter of test tube was 15.88 mm and the fin density was 33 fpi. Tests were conducted at saturation temperatures of $20^{\circ}C$ and $30^{\circ}C$. Heat fluxes varied from 5000 W/$m^2$ to 50,000 W/$m^2$ based on surface area of the plain tube. The pool boiling heat transfer coefficients of the titanium horizontal plain tube are lower than those of the copper plain tube by $8.2\%$. The boiling heat transfer coefficients of the low finned tube are averagely higher than those of the plain tubes by $34\%$. The average deviation of the Slipcevic correlation from the present data for the low finned tube is $20\%$.

Pool Boiling Heat Transfer Coefficients of New Refrigerants on Various Enhanced Tubes (열전달 촉진관에서 신냉매의 풀비등 열전달계수)

  • 박진석;김종곤;정동수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.710-719
    • /
    • 2001
  • Pool boiling heat transfer coefficients (HTCs) of HCFC123, HFC134a, HCFC22, HFC407C, HFC410A and HFC32 wre measured on a horizontal smooth tube, 26 fpi low fin tube, Turbo-B and Thermoexcel-E enhanced tubes. AN experimental apparatus was designed such that all tubes heated by cartridge heaters could be installed at the same time to save the refrigerant. Data were taken in the pool of $7^{\circ}C$ with the heat flux decreasing from 80 kW/$m^2\;to\;5kW/m^2$. Test results showed that HTCs of pure refrigerants and those of a azeotrope were greatly influenced by reduced pressure. HTCs of HFC407C were 21~25% lower than those of HCFC22 due to mass transfer resistance. For all refrigerants, enhanced tubes with sub-surface and sub-tunnels showed the largest heat transfer enhancement. Especially the largest heat enhancement was obtained for HCFC123 whose reduced pressure is the lowest among al the refrigerants tested. This indicates that either Turbo-B or Thermoexcel-E enhanced tube would be the best choice when used with a low vapor pressure refrigerant.

  • PDF

The Mediating Effects of Nutritional Status on the Relationship between Symptom Experience and Functional Status in Patients with Chronic Obstructive Pulmonary Disease (만성 폐쇄성 폐질환 환자의 증상경험과 기능상태의 관계에 미치는 영양상태의 매개효과)

  • Jang, Jun Hee;Min, Hye Sook
    • Journal of muscle and joint health
    • /
    • v.25 no.2
    • /
    • pp.112-121
    • /
    • 2018
  • Purpose: This study was conducted to explore the mediating effect of nutritional status on the relationship between symptom experience and functional status of patients with Chronic Obstructive Pulmonary Disease (COPD). Methods: A total of 141 COPD patients visiting D hospital and I hospital in B city were enrolled in this study. Data were collected from January 2017 to July 2017. Outcome variables were measured by Mini Nutritional Assessment Short-Form (MNA-SF) for nutritional status, The Memorial Symptom Assessment Scale (MSAS) for symptom experience, and The Functional Performance Inventory Short Form (FPI-SF) for functional status. The data were analyzed with descriptive statistics, Pearson's correlation, and path analysis using SPSS/WIN 21.0 and AMOS 25. Results: There was a significant negative correlation between symptom experience and nutritional status (r=-.61, p<.001), a significant negative correlation between symptom experience and functional status (r=-.40, p<.001), and significant positive correlation between nutritional status and functional status (r=.47, p<.001). Symptom experience had indirect effects on functional status through nutritional status. Conclusion: For enhancing functional status in COPD patients, it is necessary to develop nursing intervention programs to enhance symptom management as well as nutritional status.

Analysis of Damage Patterns for Gas Turbine Combustion Liner according to Model Change (모델 변천에 따른 가스터빈 연소기 라이너의 부위별 손상유형 분석)

  • Kim, Moon-Young;Yang, Sung-Ho;Park, Sang-Yeol;Kim, Sang-Hoon;Park, Hye-Sook;Won, Jong-Beom
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2862-2867
    • /
    • 2008
  • High-temperature components of gas turbine operated for certain period of time can be reused by being repaired or rejuvenated. In case of the gas turbine combustion liners, the biggest and the most important one in the high-temperature components, come in a repair shop after operated for 8,000 or 12,000 hours according to the model and go through the repair and rejuvenation in order to be reused. A stated combustion liner is the first channel which has the combustion gas reached a nozzle from a fuel nozzle. Materials and coating properties of old and new model combustion liners were investigated. To repair these components after the visual inspection, the coatings of combustion liners were removed and then FPI(Fluorescent Penetrant Inspection), a kind of the NDI(Non-Destructive Inspection), was conducted. Damage patterns and the number of the damaged components were classified and analyzed based on data provided from the visual inspection over a long period of time. Focusing on the difference between old model and new model combustion liners, we analyzed the damage distribution and changes and consequently concluded that new model combustion liner would increase repair rate.

  • PDF

Heat Transfer Characteristics of Spray Cooling up to Critical Heat Flux on a Low-fin Enhanced Surface (Low-fin 촉진 표면에서 임계 열유속까지의 분무 냉각 열전달 특성)

  • Lee, Yohan;Kang, Dong-Gyu;Jung, Dongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.9
    • /
    • pp.522-528
    • /
    • 2013
  • Spray cooling is a technology of increasing interest for electronic cooling and other high heat flux applications. In this study, heat transfer coefficients (HTCs) and critical heat fluxes (CHFs) were measured on a smooth square flat copper heater of $9.53{\times}9.53$ mm at $36^{\circ}C$ in a pool, with a smooth flat surface, and 26 fpi. Low-fin surfaces were used to see the change in HTCs and CHFs according to the surface characteristics, and FC-72 was used as the working fluid. FC-72 fluid had a significant influence on the heat transfer characteristics of the spray over the cooling surface. HTCs were taken from 10 $kW/m^2$ to critical heat flux, for all surfaces. Test results with Low-fin showed that the CHFs of all the enhanced surface were greatly improved. It can be said that the surface form affects the heat transfer coefficient and critical heat flux.

Foreign Capital Inflows and Stock Market Development in Pakistan

  • SAJID, Ali;HASHMI, Muhammad Arsalan;ABDULLAH, A.;HASAN, Muhammad Amin
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.6
    • /
    • pp.543-552
    • /
    • 2021
  • The study examines how foreign capital inflows affect stock market development in Pakistan for the period from July 2008 to June 2018. Several components of foreign capital inflows were used for empirical analysis, namely, foreign direct investment, foreign portfolio investment, and remittances. Further, market capitalization was used as a proxy for stock market development. The study uses an ARDL model for examining the long-run and short-run relationships between variables. We also analyze the bi-directional causality between the variables through the Granger causality test. Further, the presence of structural breaks was analyzed through the CUSUM and CUSUM Square test. The results suggest that in the long run, remittances have a positive and significant relationship with stock market development. However, foreign direct investment, foreign portfolio investment, and USD-PKR exchange rate do not have a significant impact on stock market development. The results also suggest that in the short run there is a negative relationship between FDI, USD-PKR exchange rate and market capitalization. Contrarily, we found a positive relationship between FPI and market capitalization. The results of Granger causality test suggest that remittances and USD-PKR exchange rate have a causal relationship with stock market development. Finally, we found no evidence of structural breaks in the dataset.

Si/SiO2 Multilayer-based Fabry-Perot Filter for 4.26 ㎛ Filtering in Carbon Dioxide Detection (이산화탄소 감지를 위한 4.26 ㎛ 필터용 poly-Si/SiO2 다층 박막 기반의 패브리 페로-필터)

  • Do, Nam Gon;Lee, Junyeop;Jung, Dong Geon;Kong, Seong Ho;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.56-60
    • /
    • 2021
  • In this study, the relationship between the transmitted light intensity and full-width-at-half-maximum (FWHM) of a Fabry-Perot filter was investigated. The measured refractive indices and absorption coefficients of the fabricated thin films were applied to the Fabry-Perot filter via simulations using optical software. Although considerable research has been conducted on Fabry-Perot filters, this study focused on the usefulness of 4.26-㎛ infrared filtering in carbon dioxide detection. Optical analysis was performed considering the effects of the thickness, refractive indices, and number of thin films in a distributed Bragg reflector. Ultimately, a clear trade-off relationship was observed wherein the transmitted light intensity decreased as the number of multilayers increased; however, the FWHM was observed to be narrower.