• Title/Summary/Keyword: FLD Analysis

Search Result 93, Processing Time 0.027 seconds

Formability Test in Warm Forming Simulation of Magnesium Alloy Sheet Using FLD (마그네슘 합금 판재의 온간성형 해석에서 FLD를 이용한 성형성 평가)

  • Lee, M.H.;Kim, H.K.;Kim, H.K.;Oh, S.I.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.556-559
    • /
    • 2008
  • In this study, the failure in circular cup deep drawing simulation at warm temperature is predicted using forming limit diagram (FLD). The FLD is used in sheet metal forming analysis to determine the criterion for fracture prediction. The simulation with heat transfer of circular cup deep drawing at warm temperature was conducted. To predict the failure, the simulation with heat transfer used FLD at temperature in the vicinity of maximum thinning. The result of the simulation with heat transfer shows that the drawn depth increases with increasing temperature and is in accord with the experimental results above $150^{\circ}C$. The FLD provides a good guide for the failure prediction of warm forming simulation with heat transfer.

  • PDF

Analytical Characteristics of GC/MS and HPLC according to the Concentration Distribution of PAHs (PAHs 농도 분포에 따른 GC/MS와 HPLC의 분석특성에 관한 연구)

  • Hong, Jwa-Ryung;Choi, Kwang-Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.312-321
    • /
    • 2015
  • Objectives: The purpose of this study was to determine the best method to analyze PAHs at extremely low concentrations. To this end, 16 PAHswere analyzed simultaneously by GC/MS, HPLC/FLD and HPLC/UVD, and the analytical characteristics of HPLC and GC/MS were compared. Methods: This study was conducted by GC/MS and HPLC/FLD/UVD, and evaluated linearity, precision and detection limit. Standard solutions were prepared for 21 samples in the range of $0.00001{\sim}1.0{\mu}g/mL$ and the samples were divided into four groups. All samples were made in three sets and analysis was replicated seven times. Results: Sixteen PAHs could be simultaneously separated by HPLC and GC/MS, and the adequate equipment was HPLC/FLD. The retention times by HPLC were shorter than GC/MS, and HPLC had better separation for most PAHs than GC/MS. The peaks of naphthalene and naphthalene-D8 partially overlapped for GC/MS. HPLC/FLD had a 20-2000 times lower limit of detection than GC/MS and UVD. However FLD was not adequate for analyzing acenaphthylene because it has too low a fluorescence quantum yield to be detected. The precision of HPLC/FLD/UVD and GC/MS showed less than 20% at $0.001{\mu}g/mL$ PAHs and when the concentration was higher, the coefficient of variation was decreased. HPLC/FLD was better for the overall detection of limits. Conclusions: The results indicate that the HPLC/FLD method has good linear range, precision and a detection of limits from $0.00001{\sim}0.0001{\mu}g/mL$ for all 16 PAHs. This study contributes to providing useful data for analysis technology and can be applied to occupational exposure measurement for PAHs in workplaces.

Application of Competitive ELISA Method for Estimation of Urinary Aflatoxin M1 Level (ELISA 방법을 이용한 요중 아플라톡신 M1 측정)

  • Kim, Yong-Dae;Kim, Heon
    • Journal of Life Science
    • /
    • v.23 no.2
    • /
    • pp.306-310
    • /
    • 2013
  • We compared the efficacy of the competitive ELISA method for measuring the level of urinary aflatoxin M1 (AFM1) with that of the HPLC-fluorescence detector (HPLC-FLD) method. The recovery rate of AFM1 with the ELISA method was 105% (73-124%), and the coefficient of variation of the analysis was 6.85%. The ELISA method showed a 0.20 pg/ml and 0.62 pg/ml limit of detection and limit of quantitation, respectively. In correlation analysis, the two methods showed a very strong and statistically significant correlation (R=0.96, p<0.01). However, in spite of the strong correlation, the ELISA method tended to overestimate the urinary AFM1 concentration compared to the HPLC-FLD method. These results suggest that the competitive ELISA method may be a useful technique for measuring the AFM1 level in high-throughput urine samples, but it needs to be corrected with a regression equation from regression analysis with the HPLC-FLD method.

Relationship of Colorectal Polyps and Fatty Liver Disease Diagnosed by Ultrasonography (초음파로 진단된 지방간 질환과 대장 용종과의 연관성)

  • Lee, Hye-Nam;Lim, Cheong-Hwan;Jung, Hong-Ryang
    • Journal of Digital Convergence
    • /
    • v.12 no.3
    • /
    • pp.345-352
    • /
    • 2014
  • This study proposes a more comprehensive approach for FLD by analyzing the relationship of colorectal polyps, which are precursors of colorectal cancer. In Chi-Square tests of FLD and colorectal polyps, the prevalence of colorectal polyps was significantly high in cases of FLD. The polyps and correlation of each factor showed a positive relationship with all factors, and the correlation coefficient with FLD was highest (r = 0.39, p <.001). In multiple regression analysis, FLD(OR 3.80 95% CI 1.93.-7.50), FBS (OR 2.51; 95% CI 1.12-5.62), and older age (OR 2.12; 95% CI 1.27-3.54) were independent risk factors for colorectal polyps. FLD was associated with the prevalence of colorectal polyps. These results show a meaningful influenceof FLD by ultrasonography in the occurrence of colorectal polyps, and that positive consideration of colonoscopy is needed for diagnosed FLD.

Formability Test of Boron Steel Sheet at Elevated Temperature for Hot Stamping (핫스탬핑용 보론강의 고온 성형한계선도 평가 연구)

  • Han, S.S.
    • Transactions of Materials Processing
    • /
    • v.26 no.2
    • /
    • pp.121-126
    • /
    • 2017
  • The hot stamping process is an innovative forming method that could prevent the cracking of high strength steel sheets. The formability test of boron steel sheet using forming limit diagrams at elevated temperature is very complicated and time consuming job. In this paper, an alternative test method to evaluate the formability of boron steel in hot stamping has proposed. It measured the FLD0 instead of whole strain combinations of FLD with the tensile test machine and specially designed test rig. Test results shows that the proposed test method can simulate the plain strain condition fracture and can make the FLD of boron steel sheet at elevated temperature with less effort.

Analysis of Neurotoxins, Anatoxin-a, Saxitoxin in Algae Cultured and Algae in Dam Reservoir and its Water Treatment (배양조류 및 댐 저수지 조체중 신경독소 Anatoxin-a, Saxitoxin류의 분석 및 수처리방안)

  • Kim, Hak-Chul;Choi, Il-Whan
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.37-44
    • /
    • 2008
  • In this study we developed the analytical methods for the determination of three neurotoxin; anatoxin-a, saxitoxin and neosaxitoxin using HPLC/FLD system and this analytical methods were applied to real sample; algae culture and algae extracts. For the HPLC/FLD analysis of anatoxin-a samples were concentrated on WCX(Weak Cation Exchanger) SPE and then anatoxin-a in concentrate was derivatized with NBD-F solution. Supernatant was injected on HPLC system. For the HPLC/FLD analysis of saxitoxin and neosaxitoxin samples were separated on the column and then derivatizied by post column reactor for fluorescen detection. For post column reaction of saxitoxin we feed two kinds of reaction solution; Oxidizing Reagent of which composition was periodic acid(7mM) in 50mM potassium phosphate buffer, pH 9 and acidifying reagent of which Composition was 0.5M acetic acid. The LOD value for anatoxin-a, saxitoxin and neosaxitoxin in HPLC/FLD method was 24.3 ng. $35{\mu}g/L$, $27{\mu}g/L$ respectively. We determined the anatoxin-a content of lyophilized anabaena flos-aquae and $20{\mu}g/g$ d.w. of anatoxin-a was detected. We analyzed saxitoxin and neosaxitoxin in algae culture media and extracts of lypopyllized algal cell cultured and that of Deachung reservior. Saxitoxin and neosaxitoxin in real sample were below the limit of detection. Although there are various water treatment processes for removing neurotoxins were suggested no process give simultaneous and complete removal of neurotoxins. It was cocluded that nanofiltration which reject material by size can be a process for removal of neurotoxins.

A Study on the Development of Force Limiting Devices of Folded Plate Type (절판형 응력제한 기구의 개발에 관한 연구)

  • Kim, Cheol Hwan;Chae, Won Tak
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.6
    • /
    • pp.571-579
    • /
    • 2014
  • The steel braces are used to control the lateral drift of high rise buildings. The braces are designed as tensile members since the braces consisted of slender member can not resist compressive loads by elastic buckling. To resolve this problem, a lot of research were performed to develop the non-buckling member. The force limiting device (FLD.) is one of them. The purpose of this study is the development of FLD. to prevent a elastic buckling for a slender member. The folded plate type is proposed to induce the yielding before occurring elastic buckling. In this study, member test and FEM analysis for proposed type were performed. Further, It is verified that the structure with FLD member is stable by high energy absorption. The proposed folded plate type FLD could be effective to preserve the compressive member from the elastic buckling.

A Study on the Development of Force Limiting Devices(FLD) which Induce Yielding before Elastic Buckling (좌굴전 항복유도 장치(FLD) 개발에 관한 연구)

  • Kim, Cheol Hwan;Chae, Won Tak;Oh, Young Suk;Kim, Chae Yeong
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.3
    • /
    • pp.279-287
    • /
    • 2013
  • The steel members are applied to high rise building since they have high strength compare to the concrete member. On the other hand, the elastic buckling is likely to occur in steel member because of their small section. When the elastic buckling occur, the steel structure lose a load carrying capacity. The steel frame would be unstable due to a rapid decline in strength by buckling. The purpose of this study is the development of FLD(Force Limiting Device) to prevent a elastic buckling for a slender member. Further, the behavior of steel structures with FLD would be stable by high energy absorption capacity. The proposed type of FLD is the type of out-of-plane resistance. In this study, member test and FEM analysis for proposed type were performed. The test parameters are thickness and gradient angle of out-of-plane plate. The proposed type may be effective method for FLD.

Development of Analytical Methods for Micro Levels of Naphthalene and TNT in Groundwater by HPLC-FLD and MSD (HPLC-FLD와 MSD를 이용한 지하수 중 나프탈렌 및 TNT의 미량 분석법 개발)

  • Park, Jong-Sung;Oh, Je-Ill;Jeong, Sang-Jo;Choi, Yoon-Dae;Her, Nam-Guk
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.6
    • /
    • pp.35-44
    • /
    • 2009
  • Naphthalene and TNT (2,4,6-trinitrotoluene) are defined by U.S. EPA as possible carcinogenic compounds known to have detrimental effects on the aquatic ecosystem and human body. There are, however, few researches on methods of analyzing micro-levels of naphthalene and TNT dissolved in groundwater. This study introduces and evaluates the newly developed analytical methods of measuring naphthalene and TNT in groundwater by using HPLC-FLD (Fluorescence detector) and MSD (Mass detector). The MDL, LOQ and salt effect of these methods, respectively, are compared with those of conventional methods which use HPLC-UV. For the analysis of naphthalene, HPLC-FLD was set in the maxima wavelength (Ex: 270 nM, Em: 330 nM) obtained from 3D-Fluorescence to be compared with HPLC-UV in 266 nM wavelength. The MDL ($0.3\;{\mu}g/L$) and LOQ ($2.0\;{\mu}g/L$) of naphthalene by using HPLC-FLD were approximately 80 times lower than those analyzed by HPLC-UV (MDL: $23.3\;{\mu}g/L$, LOQ: $163.1\;{\mu}g/L$). HPLC-MSD were used in comparison with HPLC-UV in 230 and 254 nM wavelength for the analysis of TNT. The MDL ($0.13\;{\mu}g/L$) and LOQ ($0.88\;{\mu}g/L$) of TNT analyzed by using HPLC-MSD were approximately 130 times lower than those obtained by using HPLC-UV in 230 nM (MDL: $16.8\;{\mu}g/L$, LOQ: $117.5\;{\mu}g/L$). The chromatogram of TNT analyzed by using HPLC-UV in 230 nM displayed elevated baseline as the concentration of ${NO_3}^-$ increases beyond 21 mg/L, while the analysis using HPLC-MSD did not demonstrate any change in baseline in presence of ${NO_3}^-$ of 63.7 mg/L which is 3.5 times higher than average concentration in groundwater. In conclusion, HPLC-FLD and HPLC-MSD may be used as suitable methods for the analysis of naphthalene and TNT in groundwater and drinking water. These methods can be applied to the monitoring of naphthalene and TNT concentration in groundwater or drinking water.

Monitoring of Aflatoxin $B_1$ in Livestock Feeds Using ELISA and HPLC

  • Han Eun-Mee;Park Hee-Ra;Hu Soo-Jung;Kwon Ki-Sung;Lee Hyo-Min;Ha Mi-Sun;Kim Kyung-Mi;Ko Eun-Jung;Ha Sang-Do;Chun Hyang-Sook;Chung Duck-Hwa;Bae Dong-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.4
    • /
    • pp.643-646
    • /
    • 2006
  • Because of potential health hazards of aflatoxins for humans, the present study was conducted to monitor aflatoxin $B_1\;(AFB_1)$ in livestock feeds. A total of 249 samples of feeds collected in Korea were analyzed by DC-ELISA for qualitative analysis of $AFB_1$. Then, 27 samples that were verified to contain $AFB_1$ by DC-ELISA were quantitated by HPLC/FLD. HPLC/FLD analysis revealed that only one sample collected from a farm contained 11 ppb of $AFB_1$, whereas the other samples collected from feed companies did not contain $AFB_1$. The presence of $AFB_1$ was further confirmed by LC/MS analysis. TLC analysis indicated that the result of the DC-ELISA was most likely due to possible contamination of other mycotoxins rather than $AFB_1$. In conclusion, HPLC/FLD analysis following DC-ELISA is necessary for rapid and accurate detection of $AFB_1$.