• Title/Summary/Keyword: FEAS

Search Result 58, Processing Time 0.027 seconds

Active control of field emitter arrays with a-Si:H TFTs (비정질 실리콘 박막 트랜지스터에 의한 전계방출기 어레이의 능동제어)

  • 엄현석;송윤호;강승열;정문연;조영래;황치선;이상균;김도형;이진호
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.33-36
    • /
    • 2000
  • Active-controlled field emitter arrays (ACFEAs) are developed by monolithically integrating molybdenum field emitter arrays with amorphous silicon thin film transistors (a-Si:H TFTs) on glass substrate. Transfer and output characteristics of the fabricated ACFEAs showed that the emission currents of FEAs can be accurately controlled by the gate bias voltages of TFTs. Also, the emission currents of the ACFEAs kept stable without any fluctuations during the 30 min-operation.

  • PDF

A Systematic Review of Randomized Controlled Trials on Acupuncture Treatment for Shoulder Pain (견비통에 침치료를 시행한 무작위대조군연구(RCT)들에 대한 계통적 연구)

  • Kim, Hyun-Wook;Kim, Sung-Soo;Park, Se-Woon;Kim, Eon-Kuk;Lee, Geon-Hui;Lee, Geon-Mok
    • Journal of Acupuncture Research
    • /
    • v.27 no.4
    • /
    • pp.67-84
    • /
    • 2010
  • Objectives : To review RCTs on acupuncture treatment for shoulder pain in order to establish a standard acupuncture treatment model in treating shoulder pain. Methods : RCT articles on traditional acupuncture treatment for shoulder pain were searched through online database. Quality of studies were assessed using the FEAS and the modified Jadad score. Results : Eighteen trials of acupuncture for shoulder pain were analyzed. Based on the results of these reviews the following factors might contribute to optimal results from acupuncture treatment. 1) Usage of LI, SI, TE meridians, usage of $LI_{15}$, $TE_{14}$, $GB_{21}$, $LI_{11}$, $LI_4$, $SI_{14}$, $LI_{14}$, $TE_{15}$ acupuncture points. 2) More than four acupuncture points should be used. 3) More than 15 minutes of needle retention time. 4) Needle length-40mm and diameter-0.30mm. 5) More than 9 times treatment 6) More than 5 weeks treatment duration. Conclusions : There was no relation between quality of article and effectiveness of acupuncture. To improve the remedial value, it is necessary to mention De-qi, stimulation of acupuncture and correct variation in diagnosis with the above-mentioned. It is better that clinical trials of acupuncture treatment is designed that type of RCT and double blind. Also when it is set that sham nonpenetrating acupuncture, no treatment group as a control group, and participants don't distinguish wheather acupuncture treatment or not, it will be more meaningful.

Review of Randomized Controlled Trials on Pharmacopuneture Treatment for Musculoskeletal Diseases (무작위대조군연구(RCT)를 중심으로 한 근.골격계 질환의 약침 치료에 관한 고찰)

  • Jang, Min-Ki;Yoon, Eun-Hye;Jung, Chan-Yung;Kim, Eun-Jung;Lee, Seung-Deok;Hwang, Min-Seop;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.26 no.3
    • /
    • pp.149-163
    • /
    • 2009
  • Objectives : The purpose of this study is to review RCTs on pharmacopuncture treatment for musculoskeletal diseases and to establish standards of pharmacopuncture treatment model. Methods : We searched articles up to date of March 2009 via computerized databases of Pubmed, The Journal of Korean Acupuncture & Moxibustion, Journal of Korean institute of Herbal Acupuncture, Journal of Oriental Rehabilitation and Journal of Korean Oriental Medicine. Only Randomized Controlled Trials (RCT) concerning the effects of pharmacopuncture on musculoskeletal diseases. The pharmacopuncture treatment methods were assessed based on STRICTA and items considering the feature of pharmacopuncture. And the methodological quality of the trials was assessed by FEAS and modified Jadad score. Results : Eighteen trials of pharmacopuncture on musculoskeletal diseases were analyzed. Except for 4 trials comparing the effect of SBV and BV, positive outcome was reported in ten trials. Among eighteen trials; most of the trials were about Bee Venom acupuncture, and most of the trials used about five acupuncture points, mainly local acupuncture points. But, the amount of injection to each point and total injection were various. And most of trials were lack in the information about method of stimulation. The adjusted FEAS score ranged from 0 to 12, and modified Jadad scoreranged from 1 to 5. Conclusions: To standardize pharmacopuncture treatment, we need more well-designed, high quality clinical trials. And methodological assessment tools designed for pharmacopuncture treatment are also needed.

  • PDF

Average Compressive Strengths of Stiffened Plates for In-Service Vessels Under Lateral Pressure (횡압력을 받는 실선 보강판의 평균압축강도)

  • Choung, Joon-Mo;Jeon, Sang-Ik;Lee, Min-Seong;Nam, Ji-Myung;Ha, Tae-Bum
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.4
    • /
    • pp.330-335
    • /
    • 2011
  • This paper presents estimation of average compressive strengths of three types of stiffened panels under lateral pressure and axial compression based on simplified formulas from CSRs and nonlinear FEAs. FEA scenarios are prepared based on the slenderness ratios of the stiffened panels used for in-service vessels. The seven step lateral pressures by 1bar increment are imposed on FE models assuming maximum 30m water height. The number of FEAs for FB-, AB-, and TB-stiffened panels is totally 189 times. FEA results show that existence of pressure can evolves significant reduction of ultimate strengths, meanwhile CSR formulas do not take into account the lateral pressure effect. Lateral pressure acting on the stiffened panel with higher column slenderness ratio more reduces the ultimate strengths than those with smaller column slenderness ratio. A new concept of relative average compressive strain energy instead of the ultimate strength is introduced in order to rationally compare the average compressive strength through complete compressive straining regime. The differences of the ultimate strengths between CSR formulas and FEA results are relatively small for FB- and AB-stiffened panels, but larger discrepancies of relative average compressive strain energies are shown.

Influence of Substrate Phase and Inclination Angle on Heat Transfer Characteristics in Vicinity of Hastelloy X Regions Deposited on S45C via Directed Energy Deposition (DED 공정을 이용한 S45C 위 Hastelloy X 분말 적층 시 기저부 상과 경사각이 적층부 인근 열전달 특성에 미치는 영향에 관한 연구)

  • Baek, Sun-Ho;Lee, Kwang-Kyu;Ahn, Dong-Kyu;Kim, Woo-Sung;Lee, Ho-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.10
    • /
    • pp.27-37
    • /
    • 2021
  • The use of additive manufacturing processes for the repair and remanufacturing of mechanical parts has attracted considerable attention because of strict environmental regulations. Directed energy deposition (DED) is widely used to retrofit mechanical parts. In this study, finite element analyses (FEAs) were performed to investigate the influence of the substrate phase and inclination angle on the heat transfer characteristics in the vicinity of Hastelloy X regions deposited via DED. FE models that consider the bead size and hatch distance were designed. A volumetric heat source model with a Gaussian distribution in a plane was adopted as the heat flux model for DED. The substrate and the deposited powder were S45C structural steel and Hastelloy X, respectively. Temperature-dependent thermal properties were considered while performing the FEAs. The effects of the substrate phase and inclination angle on the temperature distributions and depth of the heat-affected zone (HAZ) in the vicinity of the deposited regions were examined. Furthermore, the influence of deposition paths on depths of the HAZ were investigated. The results of the analyses were used to determine the suitable phase and inclination angle of the substrate as well as the appropriate deposition path.

Fabrication and Characterization of Si-tip Field Emitter Array (실리콘 팁 전계 방출 소자의 제조 및 동작 특성 평가)

  • 주병권;이상조;박재석;이윤희;전동렬;오명환
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.1
    • /
    • pp.65-73
    • /
    • 1999
  • Si-tip FEAs were fabricated by a lift-off based process and their operating properties were evaluated. The dependence of emission current on applied gate and anode voltages, maximum emission current, hysteresis phenomena, MOSFET-type curves, current fluctuation, light emission from the emitted electrons, and failure mechanism of the device were widely discussed based on the experimental results.

  • PDF

Application of Low-hydrogenated Diamond-like Carbon Film to Mo-tip Field Emitter Array (낮은 수소 함유량을 갖는 유사 다이아몬드 박막의 몰리브덴 팁 전계 방출 소자 응용)

  • Ju, Byeong-Kwon;Jung, Jae-Hoon;Lee, Yun-Hi;Kim, Hoon;Oh, Myung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.2
    • /
    • pp.76-79
    • /
    • 1999
  • Low-hydrogenated DLC films were coated on the Mo-tip FEAs by 'layer-by-layer' process based on the plasma-enhanced CVD method. The hydrogen content in the DLC film deposited by the 'layer-by-layer' process was appeared to be remarkably lowered through SIMS analysis. Also, the low-hydrogenated DLC-coated Mo-tip FEA showed good potentiality for FED applications in terms of turn-on voltage, emission current, emission stability and light emitting uniformity.

  • PDF

Fabrication and Properties of Under Gate Field Emitter Array for Back Light Unit in LCD

  • Jung, Yong-Jun;Park, Jae-Hong;Jeong, Jin-Soo;Nam, Joong-Woo;Berdinsky, Alexander S.;Yoo, Ji-Beom;Park, Chong-Yun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1530-1533
    • /
    • 2005
  • We investigated under-gate type carbon nanotube field emitter arrays (FEAs) for back light unit (BLU) in liquid crystal display (LCD). Gate oxide was formed by wet etching of ITO coated glass substrate instead of depositing $SiO_2$ on the glass substrate. Wet etching is easer and simpler than depositing and etching of thick gate oxide to isolate the gate metal from cathode electrode in triode. Field emission characteristic s of triode structure were measured. The maximum current density of 92.5 ${\mu}A/cm^2$ was when the gate and anode voltage was 95 and 2500 V, respectively at the anode-cathode spacing of 1500 ${\mu}m$.

  • PDF

Development of an Automation Tool for the Three-Dimensional Finite Element Analysis of Machine Tool Spindles

  • Choi, Jin-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.2
    • /
    • pp.166-171
    • /
    • 2015
  • In this study, an automation tool was developed for rapid evaluation of machine tool spindle designs with automated three-dimensional finite element analysis (3D FEA) using solid elements. The tool performs FEA with the minimum data of point coordinates to define the section of the spindle shaft and bearing positions. Using object-oriented programming techniques, the tool was implemented in the programming environment of a CAD system to make use of its objects. Its modules were constructed with the objects to generate the geometric model and then to convert it into the FE model of 3D solid elements at the workbenches of the CAD system using the point data. Graphic user interfaces were developed to allow users to interact with the tool. This tool is helpful for identification of a near optimal design of the spindle based on, for example, stiffness with multiple design changes and then FEAs.

Investigation of Physical Properties of N-doped DLC Film and Its Application to Mo-tip FEA Devices (질소가 도핑된 DLC 막의 물성 조사 및 Mo-tip FEA 소자에의 응용)

  • Ju, Byeong-Kwon;Jung, Jae-Hoon;Kim, Hoon;Lee, Yun-Hi;Lee, Nam-Yang;Oh, Myung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.1
    • /
    • pp.19-22
    • /
    • 1999
  • N-doped and low-hydrogenated DLC thin films were coated on the Mo-tip FEAs in order to improve the field emission performance and their electrical properties were evaluated. The fabricated devices showed improved field emission performance in terms of turn-on voltage, emission current and current fluctuation. This result might be caused both by the shift of Fermi level toward conduction band by N-doping and by the inherent stability of DLC material. Furthermore, the transconductance of the DLC-coated Mo-tip FEA and electrical conductivity and optical band-gap of the deposited DLC films were investigated.

  • PDF