• 제목/요약/키워드: FE modal analysis

검색결과 147건 처리시간 0.021초

500MW급 증기터빈 블레이드-디스크계의 진동특성 분석 (Vibration Characteristic Analysis of 500MW Steam Turbine Blade-Disks)

  • 최홍일;배용채;김희수;이욱륜;이두영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.253-253
    • /
    • 2008
  • The main purpose of this study is to identify the vibrational characteristics for the LP blades of Korean standard fossil power plants. Modal tests for the 6 stage blade with boundary condition in which the root of blades are constrained with the disk were conducted, and FE analysis was also did with the same boundary condition. The steady-stress and modal analyses for the coupled bladed-disk system of LP turbine stages were completed. The dynamic analysis and fatigue analysis were followed to diagnose the integrity of LP turbine blades.

  • PDF

복합재료를 사용한 지구관측위성 광학탑재체 지지구조물 개발 (Development of Composite Optical Bench for Earth observation Satellite)

  • 김진희;김경원;이주훈;진익민;윤길원
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.207-210
    • /
    • 2005
  • In this paper, technical issues for an optical bench of high precision LEO Earth observation satellite are described. The optical bench should be stable for thermal and dynamic environment. In this point of view, an intermediate type of optical bench is developed. Thermal deformation analysis and modal analysis are performed for two types of FE model. Modal test are performed to verify the analysis results. The test results fit well the analysis results.

  • PDF

수중 원통셸의 진동특성 연구 (A Study on the Modal Characteristics of Submerged Cylindrical Shell)

  • Park, Young-Jin;Kim, Sung-Joong;Han, Kyu-Hyun;Lee, Young-Shin
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.284-284
    • /
    • 2003
  • The free vibration characteristics of the cylindrical shell submerged in water is investigated using by FEM and experiment. In the FE analysis, the fluid-structure interaction effect is concerned. The restraint condition is clamped-free. In the results, the natural frequency and mode shape characteristics are evaluated with various water height. This results are compared with those of experiment to verify the validation of the FE analysis. The change of damping ratio is also presented by experiment.

  • PDF

Structural health monitoring and resilient assessment by novel intelligent models

  • C.C. Hung;T. Nguyen;C.Y. Hsieh
    • Structural Monitoring and Maintenance
    • /
    • 제10권4호
    • /
    • pp.339-360
    • /
    • 2023
  • In this paper, to assess the performance of a multi-span simply supported RC bridge, the dynamic characteristics of the bridge were measured and determined by structural health monitoring and resilient assessment via operational modal analysis as well as FE modeling. Supporting finite element (FE) models were created and analyzed according to the design drawings. This study used 2D plane monitoring of locations of hole in the infill wall and used 3D health monitoring and resilient assessment. From the results of 3Dsymmetric frame, if the frame is unsymmetrical, the used model can lead to the reduction in the internal forces. The recommendations from this study is from some discrepancies observed between 2D and 3D models, if possible 3D model should be used in analyzing the real frames.

Collapse mechanism estimation of a historical slender minaret

  • Nohutcu, H.;Hokelekli, E.;Ercan, E.;Demir, A.;Altintas, G.
    • Structural Engineering and Mechanics
    • /
    • 제64권5호
    • /
    • pp.653-660
    • /
    • 2017
  • The aim of this study is to accurately estimate seismic damage and the collapse mechanism of the historical stone masonry minaret "Hafsa Sultan", which was built in 1522. Surveying measurements and material tests were conducted to obtain a 3D solid model and the mechanical properties of the components of the minaret. The initial Finite Element (FE) model is analyzed and numerical dynamic characteristics of the minaret are obtained. The Operational Modal Analysis (OMA) method is conducted to obtain the experimental dynamic characteristics of the minaret and the initial FE model is calibrated by using the experimental results. Then, linear time history (LTH) and nonlinear time history (NLTH) analyses are carried out on the calibrated FE model by using two different ground motions. Iron clamps which used as connection element between the stones of the minaret considerably increase the tensile strength of the masonry system. The Concrete Damage Plasticity (CDP) model is selected in the nonlinear analyses in ABAQUS. The analyses conducted indicate that the results of the linear analyses are not as realistic as the nonlinear analysis results when compared with existing damage.

The effects of scour depth and riverbed condition on the natural frequencies of integral abutment bridges

  • Akbari, Reza;Maadani, Saeed;Abedi, Alireza;Maalek, Shahrokh
    • Structural Monitoring and Maintenance
    • /
    • 제6권2호
    • /
    • pp.85-101
    • /
    • 2019
  • The effects of foundation scour depth and riverbed condition on the natural frequencies of a typical cross-river integral abutment bridge have been studied. The conventional operational modal analysis technique has been employed in order to extract the modal properties of the bridge and the results have been used in the Finite Element (FE) model updating procedure. Two tests have been carried out in two different levels of water and wet condition of the riverbed. In the first test, the riverbed was in dry condition for two subsequent years and the level of water was 10 meter lower than the natural riverbed. In the second test, the river was opened to water flow from the upstream dam and the level of water was 2 meter higher than the natural riverbed. The results of these two tests have also been used in order to find to what extend the presence of water flow in the river and saturation of the surrounding soil affect the bridge natural frequencies. Finally, the updated FE model of the bridge has been applied in a series of parametric analyses incorporating the effect of piles' relative scour depth on the bridge natural frequency of the first four vibration modes.

정전 마이크로 액츄에이터의 자동 CAE 평가 (Automated CAE Evaluation of Electrostatic Micro Actuator)

  • Lee, Joon-Seong
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.711-715
    • /
    • 1996
  • This paper describes an automated computer-aided engineering (CAE) system for micromachines whose size range 10 to 10$^3$${\mu}{\textrm}{m}$. An automatic finite element mesh generation technique, which is based on the fuzzy knowledge processing and computational geometry techniques, is incorporated into the system, together with one of commercial finite clement (FE) analysis codes, MARC, and one of commercial solid modelers, Designbase. The system allows a geometry model of concern to be a automatically converted to different FE models, depending on physical phenomena to be analyzed, i.e. electrostatic analysis, stress analysis, modal analysis and so on. The FE analysis models are then exported to the FE analysis code, and then analyses are performed. This system is successfully applied to an electrostatic micro actuator.

  • PDF

대형 해상풍력발전용 필라멘트 와인딩 복합재 타워의 동적 특성에 관한 연구 (Dynamic Characteristics Analysis of Filament-wound Composite Towers for Large Scale Offshore Wind-Turbine)

  • 한정영;홍철현;정재훈;문병영
    • 한국유체기계학회 논문집
    • /
    • 제15권4호
    • /
    • pp.55-60
    • /
    • 2012
  • The purpose of this study is to investigate the buckling load of filament-wound composite towers for large scale wind-turbine using finite element method(FEM). To define material properties, we used both the effective property method and the stacking properties method. The effective properties method is to assume that composite consists of one ply. The stacking properties method is to assume that composite consists of some stacked plies. First, linear buckling analysis of the tower, filament-wounded with angles of [${\pm}30$] was carried out by two methods for composite material properties, the stacking method and the effective method. and FE analysis was performed for the composite towers according to filament winding angles of [${\pm}30$], [${\pm}45$], [${\pm}60$]. FE analysis results using the stacking properties of the composite were in good agreement with the results by the effective properties. The difference between FEM results by material properties methods was approximately 0~2.3% in buckling Analysis and approximately 0~0.6% in modal analysis. And above the angle of [${\pm}60$], there was a little change of buckling load.

유한요소 해석을 통한 슬림형 광디스크 드라이브의 진동해석 및 구조 동특성 변경 (FE Vibration Analysis and Structural Modification of Slim Type Optical Disk Drive)

  • 김경태;임승호;이용현;박노철;박영필;이인환;이한백;차익주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1284-1287
    • /
    • 2007
  • Recently, the need for slim type optical disk drive(ODD) has increased with popularization of lightweight notebook. Because of its lightweight and small structure, slim type ODD has low structural stiffness and it is weak to high-speed disk vibration. In this paper, Finite Element(FE) Model of slim type ODD is constructed and verified by experimental modal analysis. Additionally, sensitivity analysis is performed about structural parameters. As a result of sensitivity analysis, improved characteristic is verified by experiments using a sample of new model.

  • PDF

대형 풍력 발전용 필라멘트 와인딩 복합재 타워의 고유 진동수 해석에 관한 연구 (Modal Analysis of Filament-wound Composite Towers for Large Scale Wind-Turbine)

  • 홍철현
    • 한국해양공학회지
    • /
    • 제25권2호
    • /
    • pp.73-78
    • /
    • 2011
  • The purpose of this study was to investigate the natural frequency of filament-wound composite towers for large scale wind-turbines using the finite element method (FEM). To define the material properties, we used both the effective property method and the stacking properties method. The effective properties method assumes that a composite consists of one ply. The stacking properties method assumes that a composite consists of several stacked plies. First, a modal analysis of the tower, filament-wound with angles of $[{\pm}30]$, was carried out using the two methods for composite material properties, the stacking method and effective method. Then, an FE analysis was performed for composite towers using filament winding angles of $[{\pm}30]$, $[{\pm}45]$, and $[{\pm}60]$. The FE analysis results using the stacking properties of the composite were in good agreement with the results from the effective properties method. The difference between the FEM and material properties methods was approximately 0~0.6%