• 제목/요약/키워드: FE human model

검색결과 41건 처리시간 0.028초

인체 골(bone)의 유한요소 모델링을 위한 VOXEL MESH 기법에 관한 연구 (A Study on the Voxel Mesh Technique for Finite Element Modeling of Human Bone)

  • 변창환;오택열;백승민;채경덕
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.1081-1084
    • /
    • 2002
  • In this study, we perform 3-D reconstruction of human proximal femur from DICOM files by using voxel mesh algorithm. After 3-D reconstruction, the model converted to Finite Element model which developed for automatically making not only 3-D geometrical model but also FE model from medical image dataset. During this job, trabecular pattern, one of characteristic of human bone can be added to the model by means of giving it's own elastic property calculated from intensity in CT scanned image to the each voxel. And then another model is made from same image dataset which have two material properties - one corresponds to cortical bone, another to trabecular bone. Finally, validity of voxel mesh technique is verified through comparing results of FE analysis, free vibration and stress analysis.

  • PDF

Marching cube 알고리즘을 이용한 대퇴골의 유한요소 모델링에 관한 연구 (A study on the finite element modeling of femur based marching cube algorithm)

  • 곽명근;오택열;변창환;이은택;유용석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.1074-1077
    • /
    • 2002
  • Biomechanical behavior of the human femur is very important in various clinical situations. In this study, the data of FE models based on DICOM file exported from Computed tomography(CT). We generated FE models(voxel model, tetra model) of human femur using CT slide image. We compared them with Yon Mises stress results derived from finite element analysis(FEA). Comparing the two models, we found a correlation of them. As a result, the tetra model based proposed marching cube algorithm is a valid and accurate method to predict parameters of the complex biomechanical behavior of human femur.

  • PDF

목상해 분석을 위한 상세 유한요소 목모델 개발 - 저속후방 오프셋 충돌에 따른 분석 - (Development of a Finite Element Human Neck Model for Neck Injury Analysis - Application to Low Speed Rear-End Offset Impacts -)

  • 김영은;조휘창
    • 대한기계학회논문집A
    • /
    • 제29권6호
    • /
    • pp.913-920
    • /
    • 2005
  • Compared to previous in-vitro test, FE model showed reliable motion patterns. A finite element model of a 50th percentile male neck was developed to study the mechanics of whiplash injury while the rear impacts. The model was consisted of the whole cervical vertebrae including part of occipital, intervertebral discs. which were modeled using linear viscoelastic materials and posterior elements. The sliding interfaces were defined to simulate contact phenomena in facet joints and in odontoid process. All ligaments and atlanto-occipital membrane were modeled as nonlinear bar elements. Only muscle elements were not considered. Motion of each cervical vertebra was obtained from the dynamic simulation with a MADYMO model for 15 km/h $40\%$ rear end offset impacts. Soft tissue neck injury(STNI) was investigated with a developed FE model. In FE model analysis, the high stress was appeared at C3/C4 disc in offset impact. Further research is still needed in order to improve the developed neck FE model for many different crash patterns.

유한요소 모델 변수의 역 추정법을 이용한 생체의 물성 규명 (Biomechanical Characterization with Inverse FE Model Parameter Estimation: Macro and Micro Applications)

  • 안범모;김영진;신현정;김정
    • 대한기계학회논문집A
    • /
    • 제33권11호
    • /
    • pp.1202-1208
    • /
    • 2009
  • An inverse finite element (FE) model parameter estimation algorithm can be used to characterize mechanical properties of biological tissues. Using this algorithm, we can consider the influence of material nonlinearity, contact mechanics, complex boundary conditions, and geometrical constraints in the modeling. In this study, biomechanical experiments on macro and micro samples are conducted and characterized with the developed algorithm. Macro scale experiments were performed to measure the force response of porcine livers against mechanical loadings using one-dimensional indentation device. The force response of the human liver cancer cells was also measured by the atomic force microscope (AFM). The mechanical behavior of porcine livers (macro) and human liver cancer cells (micro) were characterized with the algorithm via hyperelastic and linear viscoelastic models. The developed models are suitable for computing accurate reaction force on tools and deformation of biomechanical tissues.

Mitochondrial Protein Nfu1 Influences Homeostasis of Essential Metals in the Human Fungal Pathogen Cryptococcus neoformans

  • Kim, Jeongmi;Park, Minji;Do, Eunsoo;Jung, Won Hee
    • Mycobiology
    • /
    • 제42권4호
    • /
    • pp.427-431
    • /
    • 2014
  • Mitochondrial protein Nfu1 plays an important role in the assembly of mitochondrial Fe-S clusters and intracellular iron homeostasis in the model yeast Saccharomyces cerevisiae. In this study, we identified the Nfu1 ortholog in the human fungal pathogen Cryptococcus neoformans. Our data showed that C. neoformans Nfu1 localized in the mitochondria and influenced homeostasis of essential metals such as iron, copper and manganese. Marked growth defects were observed in the mutant lacking NFU1, which suggests a critical role of Nfu1 in Fe-S cluster biosynthesis and intracellular metal homeostasis in C. neoformans.

스프링이 없는 진동형 전자기식 에너지 하베스터의 제작과 그 특성 (Fabrication of Vibration-Driven Electromagnetic Energy Harvester with Spring-Less and Its Characteristics)

  • 류경일;정귀상
    • 센서학회지
    • /
    • 제20권4호
    • /
    • pp.249-253
    • /
    • 2011
  • This paper describes the fabrication and characteristics of vibration-driven electromagnetic energy harvester without spring to use at low frequency like a human body motion. The implemented energy harvester consists of NdFeB magnets, copper coil. The optimization of induced voltage was done by the various widths of coil, number of the turns, size of fixed and moving magnets and thicknesses of the cylinder. The fabricated energy harvester is capable of producing up to 15.0 $V_{pp}$ for basic model and 28.80 $V_{pp}$ for improved model at 5.0 Hz resonance frequency and 0.75 g acceleration level. The basic model and improved model are provided a maximum power of 6.375 mWand 25.831 mW at 1 KHz of load resistance in rectifier circuit.

Skin Corrosion and Irritation Test of Nanoparticles Using Reconstructed Three-Dimensional Human Skin Model, EpiDermTM

  • Kim, Hyejin;Choi, Jonghye;Lee, Handule;Park, Juyoung;Yoon, Byung-Il;Jin, Seon Mi;Park, Kwangsik
    • Toxicological Research
    • /
    • 제32권4호
    • /
    • pp.311-316
    • /
    • 2016
  • Effects of nanoparticles (NPs) on skin corrosion and irritation using three-dimensional human skin models were investigated based on the test guidelines of Organization for Economic Co-operation and Development (OECD TG431 and TG439). EpiDerm$^{TM}$ skin was incubated with NPs including those harboring iron (FeNPs), aluminum oxide (AlNPs), titanium oxide (TNPs), and silver (AgNPs) for a defined time according to the test guidelines. Cell viabilities of EpiDerm$^{TM}$ skins were measured by the 3-(4, 5-dimethylthiazol-2-yl)-2.5-diphenyltetrazolium bromide based method. FeNPs, AlNPs, TNPs, and AgNPs were non-corrosive because the viability was more than 50% after 3 min exposure and more than 15% after 60 min exposure, which are the non-corrosive criteria. All NPs were also non-irritants, based on viability exceeding 50% after 60 min exposure and 42 hr post-incubation. Release of interleukin 1-alpha and histopathological analysis supported the cell viability results. These findings suggest that FeNPs, AlNPs, TNPs, and AgNPs are 'non-corrosive' and 'non-irritant' to human skin by a globally harmonized classification system.

유한요소 모델을 이용한 중이의 소리전달 특성 해석 (Finite Element Analysis of Sound Transfer Characteristics for Middle Ear)

  • 갈영민;백무진;이두호
    • 대한기계학회논문집A
    • /
    • 제35권12호
    • /
    • pp.1563-1571
    • /
    • 2011
  • 본 연구에서는 인간중이의 소리전달특성 계산을 위한 유한요소모델을 개발하였다. 이소골의 형상을 얻기 위하여 한국인 사체에서 추출한 측두골을 마이크로 CT 촬영하여 3 차원 입체모델로 변환하였다. 유한요소모델은 이소골, 고막, 인대와 근육 등을 포함하여 구성하였다. 유한요소모델을 이용하여 고막에서 등골족판까지의 응답함수를 계산한 후 측정값을 갖는 선행연구와 비교하였고 그 결과 10 kHz 주파수 대역까지 소리전달특성을 잘 표현하고 있음을 보였다. 또한 유한요소 모델을 구성하는 주요 물성인자의 변화에 대한 소리전달특성의 변화를 살피고 침등골관절의 강성값이 중이의 소리전달특성에 큰 영향을 미침을 보였다.