• Title/Summary/Keyword: FE analysis method

Search Result 1,541, Processing Time 0.031 seconds

Analysis of porous micro sandwich plate: Free and forced vibration under magneto-electro-elastic loadings

  • Mohammadimehr, Mehdi;Meskini, Mohammad
    • Advances in nano research
    • /
    • v.8 no.1
    • /
    • pp.69-82
    • /
    • 2020
  • In this study, the free and forced vibration analysis of micro sandwich plate with porous core layer and magneto-electric face sheets based on modified couple stress theory and first order shear deformation theory under simply supported boundary conditions is illustrated. It is noted that the core layer is composed from balsa wood and also piezo magneto-electric facesheets are made of BiTiO3-CoFe2O4. Using Hamilton's principle, the equations of motion for micro sandwich plate are obtained. Also, the Navier's method for simply support boundary condition is used to solve these equations. The effects of applied voltage, magnetic field, length to width ratio, thickness of porous to micro plate thickness ratio, type of porous, coefficient of porous on the frequency ratio are investigated. The numerical results indicate that with increasing of the porous coefficient, the non-dimensional frequency increases. Also, with an increase in the electric potential, the non-dimensional frequency decreases, while and with increasing of the magnetic potential is vice versa.

Synthesis and Characteristics of the Organic Layered Structure Material of $(C_4H_9NH_3)_2Fe_xPb_1-xCl_4$

  • Jeong, Su Jin;In, Ri Ju;O, Eung Ju;Jo, Ung In;Kim, Gyu Hong;Yo, Cheol Hyeon
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.7
    • /
    • pp.703-708
    • /
    • 2001
  • K2NiF4-type organic-based perovskites of the (C4H9NH3)2FexPb1-xCl4 (x=0.00, 0.25, 0.50, and 0.75) system have been synthesized using a low-temperatu re solution method under a flowing argon gas. When stoichiometric butylamine, iron chloride, and lead chloride are mixed, a yellow solution are obtained from slow cooling of 90 to -10 $^{\circ}C.$ The final product is a plate-like yellow crystal. The X-ray crystallographic analysis has been carried out using XRD in the range of $5^{\circ}{\leq}$ 2${\theta}$ ${\leq}80^{\circ}.$ The local symmetry around the absorbing Pb atom of the samples has been determined by the EXAFS spectroscopic study. The crystals assign to orthorhombic system by the XRD analysis. The FT-IR spectra are analyzed in the range of 600 to 3300 cm-1 . DSC and TGA are measured to detect thermal stability between 30 and 300 $^{\circ}C.$ Two endothermic peaks are detected in all samples. The electrical conductivity has been measured using the four-probes technique for the (C4H9NH3)2FexPb1-xCl4 system in 300-460 K. Photoluminescence phenomenon was also investigated at room-temperature.

Confinement coefficient of concrete-filled square stainless steel tubular stub columns

  • Ding, Fa-xing;Yin, Yi-xiang;Wang, Liping;Yu, Yujie;Luo, Liang;Yu, Zhi-wu
    • Steel and Composite Structures
    • /
    • v.30 no.4
    • /
    • pp.337-350
    • /
    • 2019
  • The objective of this paper is to investigate the confinement coefficient of concrete-filled square stainless steel tubular (CFSSST) stub columns under axial loading. A fine finite 3D solid element model was established, which utilized a constitutive model of stainless steel considering the strain-hardening characteristics and a triaxial plastic-damage constitutive model of concrete with features of the parameter certainty under axial compression. The finite element analysis results revealed that the increased ultimate bearing capacity of CFSSST stub columns compared with their carbon steel counterparts was mainly due to that the composite action of CFSSST stub columns is stronger than that of carbon steel counterparts. A further parametric study was carried out based on the verified model, and it was found that the stress contribution of the stainless steel tube is higher than the carbon steel tube. The stress nephogram was simplified reasonably in accordance with the limit state of core concrete and a theoretical formula was proposed to estimate the ultimate bearing capacity of square CFSSST stub columns using superposition method. The predicted results showed satisfactory agreement with both the experimental and FE results. Finally, the comparisons of the experimental and predicted results using the proposed formula and the existing codes were illustrated.

Probabilistic Strength at Serviceability Limit State for Normal and SBHS Slender Stiffened Plates Under Uniaxial Compression

  • Rahman, Mahmudur;Okui, Yoshiaki;Anwer, Muhammad Atif
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1397-1409
    • /
    • 2018
  • Stiffened plates with high slenderness parameters show large out-of-plane deflections, due to elastic buckling, which may occur before the plates reach their ultimate strength. From a serviceability point of view, restriction of out-of-plane deflections exceeding the fabrication tolerance is of primary importance. Compressive strength at the serviceability limit state (SLS) for slender stiffened plates under uniaxial stress was investigated through nonlinear elasto-plastic finite element analysis, considering both geometric and material nonlinearity. Both normal and high-performance steel were considered in the study. The SLS was defined based on a deflection limit and an elastic buckling strength. Probabilistic distributions of the SLS strengths were obtained through Monte Carlo simulations, in association with the response surface method. On the basis of the obtained statistical distributions, partial safety factors were proposed for SLS. Comparisons with the ultimate strength of different design codes e.g. Japanese Code, AASHTO, and Canadian Code indicate that AASHTO and Canadian Code provide significantly conservative design, while Japanese Code matches well with a 5% non-exceedance probability for compressive strength at SLS.

Evaluation of the Burst Pressure for Rectangular Wall-thinning of CANDU Feeder Pipe (사각 감육을 고려한 중수로 공급자관 파열압력 평가)

  • Kwang Soo Kim;Min Kyu Kim;Doo Ho Cho;Jae Joon Jeong
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.1
    • /
    • pp.28-35
    • /
    • 2021
  • The flow accelerated corrosion (FAC) is one of significant aging and degradation mechanism and can affect structural integrity of CANDU feeder pipes. Pipe burst can occur under normal operation pressure (min. 10 MPa) if wall-thinning of the feeder pipe due to FAC is accumulated. Previous studies considered simple shapes of feeder pipe with local wall-thinning in order to conservatively assess structural integrity of wall-thinned feeder pipe. In this paper, a new FE model is developed, having an actual shape of the feeder pipe (double bent) as well as the actual wall-thinning shape and location based on the in-service inspection result. Then, the burst pressure assessment of the wall-thinned feeder pipe is performed using lower bound limit load analysis considering elastic-perfectly plastic material. In addition, an improved formulation to predict the burst pressure of the wall-thinned feeder pipe is presented and the safety margin is compared with an existing assessment method.

A Study on Frequency and the Physical Properties of Ni-Cu-Zn Ferrites with the Variation of Ni Addition and Temperature Prepared by Co-Precipitation Method (공침법으로 제조한 Ni-Cu-Zn Ferrite의 Ni 첨가량과 온도에 따른 주파수 및 물리적 특성 연구)

  • Kim, Moon-Suk;Koh, Jae-Gui
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.5
    • /
    • pp.282-286
    • /
    • 2005
  • Ni-Cu-Zn ferrites were prepared by the co-precipitation and ferrite microwave absorbers on low temperature sintering were investigated in this work. The properties of its microwave absorbing and physical were analyzed into variations of Ni addition, calcination temperature, sintering temperature. From the analysis of X-ray diffraction patterns, we can see that all the particles have only a single phase spinel structure. In addition, the powders particle size distribution obtained the nano size. By increasing the Ni additive, the permeability of the powders was decreased and the loss factor increased at sintering temperature $1100^{\circ}C$. Also, we considered that it can used high frequency rage. We found that the $(Ni_{0.7}Cu_{0.2}Zn_{0.1}O)_{1.02}(Fe_{2}O_3)_{0.98}$ appeared microwave absorbing properties better than other composition.

Use of High Molecular Alkylamines in the Simultaneous Determination of Copper and Cobalt by Spectrophotometry (구리와 코발트의 분광광도법에 의한 정량에 있어서 고분자량 알킬아민의 이용)

  • Chon Han Kim;Chan Ho Jee;Ki Tae Sung;Chang Ung Joung
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.208-214
    • /
    • 1989
  • A method for the simultaneous determination of copper and cobalt by spectrophotometry has been described. The procedure involves the co-extraction of Cu(Ⅱ) and Co(Ⅱ) from 0.3M HCl into methyl isobutyl ketone as the ion-pairs formed between their thiocyanate complexes and high molecular alkylamines such as Amberlite LA1, Alamine 336, and Aliquat 336. The extract shows the color development to have the maximum absorbances at two different wavelengths i.e., 480 nm for copper and 625 nm for cobalt. Since the spectra of the ion-pairs overlap each other, two simultaneous equations are used to obtain the concentrations from absorbances. Even small amount of Fe(Ⅲ) and Ni(Ⅱ) interferes with the determination of copper. The results of the analysis of samples are in good agreement with the results determined by separate methods within RSD 5.9%.

  • PDF

Evaluation of $CO_2$ Uptake Using $CO_2$ Philic Adsorbents in Mortar (친 이산화탄소 흡착제를 이용한 모르타르 내 이산화탄소 흡수능 평가)

  • Park, Hyojeong;Jang, Junwon;Lee, Jihyun;Park, Jaewoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.11
    • /
    • pp.11-17
    • /
    • 2012
  • This study focused on application of various $CO_2$ philic adsorbents with amine to improve $CO_2$ uptake in mortar. TGA, phenolphthalein method, FT-IR XRD, and FE-SEM analysis methods were used to evaluate $CO_2$ capture in mortar. When $CO_2$ philic adsorbents was used, $CO_2$absorption efficiency was improved maximum of 58.5%. Carbonation depth was increased 3 times compared with original mortar. Chemical reactions between bicarbonate ion, $CO_2$, $CO_2$ philic adsorbents aqueous solution, and $Ca^{2+}$ ions dissolved from cement formed $CaCO_3$ in the mortar. Therefore, impregnation of the $CO_2$ philic adsorbent on the surface of the mortar can increase the adsorbed $CO_2$.

A Comparison Study on the Concentration of Total Welding Fume and Respirable Particulate Mass for Welding Workers of a Shipbuilding (조선소 용접작업자들의 총용접흄과 호흡성분진농도 비교연구)

  • Kang, Yong-Seon;Sim, Sang-Hyo;Lee, Song-Kwon;Bin, Sung-Oh;Choi, Eun-Seok
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.276-282
    • /
    • 2007
  • The purpose of this study is to assess the accurate state of the following: total welding fumes versus welding fumes in the air, respirable particulate mass, and exposure of dockyard welders to heavy metals. In addition, this study provides basic data for proposing improvements to create efficient and appropriate welding environments and to prevent occupational diseases. The subjects of this study were 94 laborers who worked at the block construction sites of large-scale dockyards located in Gyeongnam Province from March 2005 to June 2005. In order to collect samples on total welding fumes in the air and respirable particulate mass from the welders, Methods 0500 and 0600, established by the National Institute for Occupational Safety and Health (NIOSH), were used. The metals within the welding fumes were also analyzed using Inductively Coupled Plasma (ICP) under Method 7300 from NIOSH. The results of this research are summarized below. The geometric mean concentration of total welding fumes and that of respirable particulate mass were $4.11\;mg/m^3\;and\;3.53\;mg/m^3$, respectively. As a result of comparing the two measurement methods, there were significant differences (p<0.05) between the two groups for Ca, Cu, Cr, and Ni; however, there were no differences in Fe, Mg, Zn, Mg, Pb, and Cd. As a result of the analysis, the correlation between Mn and the concentration of heavy metals in the total welding fumes and respirable particulate mass was found to be -0.29, a significant negative correlation. The correlation between other heavy metals, however, was low. Finally, in the same total welding fumes, the correlation of Fe and Mg was high.

Bolted connectors with mechanical coupler embedded in concrete: Shear resistance under static load

  • Milicevic, Ivan;Milosavljevic, Branko;Pavlovic, Marko;Spremic, Milan
    • Steel and Composite Structures
    • /
    • v.36 no.3
    • /
    • pp.321-337
    • /
    • 2020
  • Contemporary design and construction of steel-concrete composite structures employs the use of prefabricated concrete elements and demountable shear connectors in order to reduce the construction time and costs and enable dismantling of elements for their potential reuse at the end of life of buildings. Bolted shear connector with mechanical coupler is presented in this paper. The connector is assembled from mechanical coupler and rebar anchor, embedded in concrete, and steel bolt, used for connecting steel to concrete members. The behaviour and ultimate resistance of bolted connector with mechanical coupler in wide and narrow members were analysed based on push-out tests and FE analyses conducted in Abaqus software, with focus on concrete edge breakout and bolt shear failure modes. The effect of concrete strength, concrete edge distance and diameter and strength of bolts on failure modes and shear resistance was analysed. It was demonstrated that premature failure by breakout of concrete edge occurs when connectors are located 100 mm or closer from the edge in low-strength and normal-strength reinforced concrete. Furthermore, the paper presents a relatively simple model for hand calculation of concrete edge breakout resistance when bolted connectors with mechanical coupler are used. The model is based on the modification of prediction model used for cast-in and post-installed anchors loaded parallel to the edge, by implementing equivalent influence length of connector with variable diameter. Good agreement with test and FE results was obtained, thus confirming the validity of the proposed method.