• 제목/요약/키워드: FDS (Fire Dynamics Simulator)

검색결과 141건 처리시간 0.022초

Application of FDS for the Hazard Analysis of Lubricating Oil Fires in the Air Compressor Room of Domestic Nuclear Power Plant (국내 원자력발전소의 공기 압축기실에서 윤활유 화재의 위험성 분석을 위한 FDS의 활용)

  • Han, Ho-Sik;Hwang, Cheol-Hong;Baik, Kyung Lok;Lee, Sangkyu
    • Journal of the Korean Society of Safety
    • /
    • 제31권2호
    • /
    • pp.1-9
    • /
    • 2016
  • The standard procedure of fire modeling was reviewed to minimize the user dependence, based on the NUREG-1934 and 1824 reports. The hazard analysis of lubricating oil fires in the air compressor room of domestic nuclear power plant (NPP) was also performed using a representative fire model, FDS (Fire Dynamics Simulator). The area ($A_f$) and location of fire source were considered as major parameters for the realistic fire scenarios. As a result, the maximum probability to exceed the thermal damage criteria of IEEE-383 unqualified electrical cables was predicted as approximately 70% with $A_f=1m^2$. It was also found that for qualified electrical cables, the maximum probabilities of exceeding the criteria were 2% and 90% with $A_f=2$ and $4m^2$, respectively. It was concluded that all electrical cables should be replaced with IEEE-383 qualified cables and the dike to restrict as $A_f{\leq}2m^2$ should be installed at the same time, in order to assure the thermal stability of electrical cables for lubricating oil fires in the air compressor room of domestic NPP.

Comparative Study on The Numerical Simulation for The Back-Layer of The Tunnel Fire-Driven Flow with LES and RANS (터널화재유동의 역기류 해석을 위한 LES 및 RANS 결과의 비교 고찰)

  • Jang, Yong-Jun;Kim, Hag-Beom;Kim, Jin-Ho;Han, Seok-Youn
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제33권3호
    • /
    • pp.156-163
    • /
    • 2009
  • In this study, comparative analysis on the back-layer phenomena in the tunnel-fire driven flow is performed using numerical simulation with LES and RANS. FDS(Fire Dynamics Simulator) code is employed to calculate the fire-driven turbulent flow for LES and Smartfire code is used for RANS. Hwang and Wargo's data of scaling tunnel fire experiment are employed to compare with the present numerical simulation. The modeled tunnel is 5.4m(L) ${\times}$ 0.4m(W) ${\times}$ 0.3m(H). Heat Release Rate (HRR) of fire is 3.3kW and ventilation-velocity is 0.33m/s in the main stream. The various grid-distributions are systematically tested with FDS code to analyze the effects of grid size. The LES method with FDS provides an improved back-layer flow behavior in comparison with the RANS (${\kappa}-{\epsilon}$) method by Smartfire. The FDS solvers, however, overpredict the velocity in the center region of flow which is caused by the defects in the tunnel-entrance turbulence strength and in the near-wall turbulent flow in FDS code.

FDS Simulation and Validation on the Under-Ventilated Compartment Fires (환기부족 구획화재에 대한 FDS 해석 및 검증)

  • Ko, Gwon-Hyun;Kim, Sung-Chan;Hamins, A.;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • 제23권5호
    • /
    • pp.103-109
    • /
    • 2009
  • In this study, fire simulations on the under-ventilated compartment fires have been conducted using the Fire Dynamics Simulator (FDS Ver. 5.2) and its prediction performance on the thermal and combustion chemical characteristics has been discussed. The temperature and chemical species concentrations in the upper layer of methane, heptane, and toluene fires located in a 2/5 scale compartment based on the ISO-9705 standard room are predicted and compared with the previously published experimental data. The results showed that the FDS simulations reproduced well the temperature of the ceiling and the mixture fraction in the upper layer under the well-ventilation conditions. For the under-ventilated fires, which were taken place due to the insufficient oxygen entrainment, the prediction by the FDS significantly under-estimated the production of carbon monoxide and soot compared to the experimental data.

Uncertainty Analysis of Fire Modeling Input Parameters for Motor Control Center in Switchgear Room of Nuclear Power Plants (원자력발전소 모터제어반 스위치기어실 화재 모델링 입력변수 불확실성 분석)

  • Kang, Dae-Il;Yang, Joon-Eon;Yoo, Seong-Yeon
    • Fire Science and Engineering
    • /
    • 제26권2호
    • /
    • pp.40-52
    • /
    • 2012
  • This paper presents the uncertainty analysis results of fire modeling input parameters for motor control center in switchgear room of nuclear power plants. FDS (Fire Dynamics simulator) 5.5 was used to simulate the fire scenario and Latin Hyper Cube Monte Carlo simulations were employed to generate random samples for FDS input parameters. The uncertainty analysis results of input parameters are compared with those of the model uncertainty analysis and sensitivity analysis approaches of NUREG-1934. The study results show that the input parameter uncertainty analysis approach may lead to more conservative results than the uncertainty analysis and sensitivity analysis methods of NUREG-1934.

Fire Modeling and Smoking Control Characteristic Analysis of Electric Room by Using FDS (FDS를 이용한 전기실의 화재모델링 및 연기제어 특성 분석)

  • Choi, Jeong-A;Lee, Min-Gu;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제19권3호
    • /
    • pp.662-668
    • /
    • 2018
  • Most electric rooms are located in the underground spaces of buildings. When a fire occurs in electrical equipment, the fire expands to cable insulation material, resulting in toxic smoke and combustion products. If the smoke and combustion products quickly move vertically and horizontally, the evacuation of occupants and firefighting activities will be hindered. Therefore, it is necessary to design optimal equipment for smoke control in cases of fires in electric rooms. This study analyzes the characteristics of smoke and combustion products in fires in a cubicle-type switchboard in an electric room using PyroSim, which is based on the program Fire Dynamics Simulator (FDS). The fire modeling consists of four scenarios according to the operation mode of the mechanical ventilation equipment, the amount of air supply and exhaust, and the location of the air supply slot. The analysis shows that the mechanical ventilation equipment improves the smoke density, visibility, carbon monoxide concentration, and temperature characteristics. The visibility and temperature characteristics were improved when the air flow rate and the location of the air supply slot from fire defense regulations were applied.

Analysis for Fire Spread through Double Skin Facade System with FDS (화재시뮬레이션(FDS)을 이용한 Double Skin 연소확대 위험에 관한 고찰)

  • Huh, Yoon-Taek;Park, Chang-Bok;Sung, June-Shik;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • 제23권5호
    • /
    • pp.110-116
    • /
    • 2009
  • This study is related with fire risk assessment for fire and smoke spread of double skin facade system by use of FDS (Fire Dynamics Simulator) which is a computational fluid dynamics (CFD) model of fire-driven fluid flow. For the study, fire scenario is intended to evaluate the impact of a fire spread for glazed office building. The major purpose of this study is to analyze the fire risk depending on the width of between inner skin and outer skin and to present fire prevention method regarding double skin facade system. The result of analysis presents fire spread more vertically as intermediate space becomes narrow. It is anticipated that fire can spread upper 2 stories above the fire floor if intermediate space with not more than 1m width. Therefore, prevention of vertical fire spread is required.

A Numerical Study of the Effect of Sprinkler Spray on the Flow Characteristics Induced by Fire (스프링클러 분무가 화재유동특성에 미치는 영향에 관한 수치해석 연구)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • 제26권5호
    • /
    • pp.105-110
    • /
    • 2012
  • The present study investigates the effects of sprinkler spray on fire driven flow characteristics in a compartment based on numerical approach. The FDS (Fire Dynamics Simulator), a widely used fire field model, was used to simulate the fire induced flow and sprinkler spray and a series of grid independence tests have been performed to obtain the optimal grid size. In order to validate the result predicted by FDS model, the calculated results were compared with experimental results of Magnone et al.. The FDS model matches quite well to experiments in temperature profile and mass flux through doorway, however, the discrepancy between the FDS model and experiments increases with increasing water discharge rate. As with previous study, the FDS calculation also shows a decrease of mass flow rate of combustion products through doorway due to the sprinkler spray. This study can contribute to optimize the sprinkler system design and verify the validity of the fire field model with sprinkler spray.

Sensitivity Analysis of FDS Results for the Input Uncertainty of Fire Heat Release Rate (화재 열발생률 입력 불확실도에 대한 FDS 결과의 민감도 분석)

  • Cho, Jae-Ho;Hwang, Cheol-Hong;Kim, Joosung;Lee, Sangkyu
    • Journal of the Korean Society of Safety
    • /
    • 제31권1호
    • /
    • pp.25-32
    • /
    • 2016
  • A sensitivity analysis of FDS(Fire Dynamics Simulator) results for the input uncertainty of heat release rate (Q) which might be the most influencing parameter to fire behaviors was performed. The calculated results were compared with experimental data obtained by the OECD/NEA PRISME project. The sensitivity of FDS results with the change in Q was also compared with the empirical correlations suggested in previous literature. As a result, the change in the specified Q led to the different dependence of major quantities such as temperature and species concentrations for the over- and under-ventilated fire conditions, respectively. It was also found that the sensitivity of major quantities to uncertain value of Q showed the significant difference in results obtained using the previous empirical correlations.

Validation of FDS for the Pool Fires within Two Rooms (이중격실 Pool 화재에 대한 FDS 검증분석)

  • Bae, Young-Bum;Ryu, Su-Hyun;Kim, Yun-Il;Lee, Sang-Kyu;Keum, O-Hyun;Park, Jong-Seok
    • Fire Science and Engineering
    • /
    • 제24권5호
    • /
    • pp.60-67
    • /
    • 2010
  • Fire model shall be verified and validated to reliably predict the consequences of fires within its limitations. Generally the verification and validation procedures are conducted by comparison with experimental test data. This study aims to evaluate predictive capabilities of FDS in the pool fire with two rooms and the sensitivity between input parameters such as heat release rate and ventilation rate and the output values like temperature, concentration, and heat flux. The predictive capabilities of FDS will be evaluated by comparing FDS simulation results with PRISME experimental data which result from the international fire test project. The sensitivity analysis will be conducted to decide which one of input parameters affects outcomes by comparison of FDS results with ${\pm}$ 10% changes of input parameter. From this study, the FDS predictive capabilities are within 20% error range. Heat release rate as input parameter affects most of outcomes and flow rate only has relation with concentration of oxygen and combustion products.

Effects of Ventilation Condition on the Fire Characteristics in Compartment Fires (Part II: Multi-dimensional Fire Dynamics) (구획화재에서 환기조건의 변화가 화재특성에 미치는 영향 (Part II: 다차원 화재거동))

  • Kim, Jong-Hyun;Ko, Gwon-Hyun;Park, Chung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • 제24권5호
    • /
    • pp.32-38
    • /
    • 2010
  • Multi-dimensional fire dynamics were studied numerically with the change in ventilation conditions in a full-scale ISO 9705 room. Fire Dynamic Simulator (FDS) was used for the identical conditions conducted in previous experiments. Flow rate and doorway width were changed to create over-ventilated fire (OVF) and under-ventilated fire (UVF). From the numerical simulation, it was found that the internal flow pattern rotated in the opposite direction for the UVF relative to the OVF so that a portion of products recirculated to the inside of compartment. Significant change in flow pattern with ventilation conditions may affect changes in the complex process of CO and soot formation inside the compartment due to increase in the residence time of high-temperature products. The fire behavior in the UVF created complex 3D characteristics of species distribution as well as thermal and flow structures. In particular, additional burning near the side wall inside the compartment significantly affected the flow pattern and CO production. The distribution of CO inside the compartment was explained with 3D $O_2$ distribution and flow patterns. It was observed that gas sampling at local positions in the upper layer were insufficient to completely characterize the internal structure of the compartment fire.