• 제목/요약/키워드: FDG PET-CT

검색결과 407건 처리시간 0.021초

$^{18}F-FDG$ 섭취를 보인 하지의 혈관평활근종 (Uptake of $^{18}F-FDG$ in the Angioleiomyoma of the Leg)

  • 김호균;박영찬
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권1호
    • /
    • pp.59-61
    • /
    • 2007
  • Angioleiomyoma is a rare benign tumor arising from the vascular smooth muscle (tunica media) and characterized by either a painful or painless, solitary subcutaneous nodule occurring most often in the lower extremity. We report a case of intense FDG uptake in the angioleiomyoma of right lower leg on $^{18}F-FDG$ PET/CT.

Image texture feature를 이용하여 비소세포폐암 전이 예측 머신러닝 모델 연구 (Study of machine learning model for predicting non-small cell lung cancer metastasis using image texture feature)

  • 주혜민;우상근
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2023년도 제68차 하계학술대회논문집 31권2호
    • /
    • pp.313-315
    • /
    • 2023
  • 본 논문에서는 18F-FDG PET과 CT에서 추출한 영상인자를 이용하여 비소세포폐암의 전이를 예측하는 머신러닝 모델을 생성하였다. 18F-FDG는 종양의 포도당 대사 시 사용되며 이를 추적하여 환자의 암 세포를 진단하는데 사용되는 의료영상 기법 중 하나이다. PET과 CT 영상에서 추출한 이미지 특징은 종양의 생물학적 특성을 반영하며 해당 ROI로부터 계산되어 정량화된 값이다. 본 연구에서는 환자의 의료영상으로부터 image texture 프절 전이 예측에 있어 유의한 인자인지를 확인하기 위하여 AUC를 계산하고 단변량 분석을 진행하였다. PET과 CT에서 각각 4개(GLRLM_GLNU, SHAPE_Compacity only for 3D ROI, SHAPE_Volume_vx, SHAPE_Volume_mL)와 2개(NGLDM_Busyness, TLG_ml)의 image texture feature를 모델의 생성에 사용하였다. 생성된 각 모델의 성능을 평가하기 위해 accuracy와 AUC를 계산하였으며 그 결과 random forest(RF) 모델의 예측 정확도가 가장 높았다. 추출된 PET과 CT image texture feature를 함께 사용하여 모델을 훈련하였을 때가 각각 따로 사용하였을 때 보다 예측 성능이 개선됨을 확인하였다. 추출된 영상인자가 림프절 전이를 나타내는 바이오마커로서의 가능성을 확인할 수 있었으며 이러한 연구 결과를 바탕으로 개인별 의료 영상을 기반으로 한 비소세포폐암의 치료 전략을 수립할 수 있을 것이라 기대된다.

  • PDF

종양 환자의 F-18 FDG PET/CT에서 관찰된 심근 섭취의 임상적 의미 (Clinical Significance of Myocardial Uptake on F-18 FDG PET/CT Performed in Oncologic Patients)

  • 조호진;조응혁;이종두;강원준
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권6호
    • /
    • pp.519-525
    • /
    • 2009
  • 목적: 심근의 F-18 FDG 섭취는 다양한 인자에 의해 영향을 받으며, 가역적인 허혈성 심질환이 있을 경우 심근에서 포도당 대사가 증가된다고 알려졌다. 이 연구에서는 허혈성 심질환의 과거력이 없는 종양 환자에서 시행한 F-18 FDG PET/CT에서 심근 섭취 정도 및 분포를 관찰하고, 심근 관류 SPECT와 비교하여 F-18 FDG 심근 섭취 소견으로 심근 허혈을 예측할 수 있는지를 알아보고자 하였다. 대상 및 방법: 2005년 1월부터 2009년 6월까지 F-18 FDG PET/CT를 시행한 환자 중 3개월 이내에 Tc-99m sestamibi 심근 관류 SPECT를 시행한 환자 77명을 대상으로 후향적 분석을 시행하였다. 결과: 77명의 환자 중 F-18 FDG PET/CT에서 심근에 섭취가 증가하여 있는 경우는 55명(71.4%)이었다. 이 중 40명은 균등 심근 섭취를 보였고 15명은 국소 심근 섭취를 보였다. 균등 F-18 FDG 섭취 증가를 보인 40명의 환자 중 17명(42.5%)에서 격벽에 섭취 감소가 관찰되었으나, 심근 관류 SPECT상 유의한 관류 이상은 관찰되지 않았다. 전체 심근에 균등한 섭취를 보인 23명(57.5%) 중 1명(4.3%)에서 하벽에 가역적인 관류 결손이 관찰되었고, 1명(4.3%)에서 측벽에 비가역적인 관류 결손이 관찰되었으며, 21명(91.3%)에서는 관류 결손이 관찰되지 않았다. 국소 심근 섭취를 보인 15명 중 9명(60.0%)은 기저부에 국소 섭취 증가를 보였고, 이 중 1명에서 심첨측벽에 가역적인 관류 결손이 관찰되었다. 국소적인 심근 섭취를 보인 나머지 6명(40.0%)의 환자 중에서 4명(66.7%)의 환자에서 가역적인 관류 결손이 관찰되었다. 결론: 전신 F-18 PET/CT에서 심근에 격벽 감소나 기저부 증가를 제외한 국소적인 섭취 증가가 관찰되는 경우에는 허혈성 심질환의 가능성이 있으므로 추가적인 진단 검사가 필요하다.

$[^{18}F]FDG$ 소동물 PET과 CT를 이용한 폐 전이 종양 마우스 모델의 영상화 (Imaging of Lung Metastasis Tumor Mouse Model using $[^{18}F]FDG$ Small Animal PET and CT)

  • 김준엽;우상근;이태섭;김경민;강주현;우광선;정위섭;정재호;천기정;최창운;임상무
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권1호
    • /
    • pp.42-48
    • /
    • 2007
  • 목적: 이 연구에서는 폐 전이 종양을 영상화하기 위하여 흑색종의 폐 전이 종양 마우스 모델을 제작하고 영상 획득 전처리 조건을 개선하여 폐 전이 종양의 $[^{18}F]FDG$ 소동물 PET 영상을 획득하고자 하였으며, 임상 CT를 이용하여 전이 종양의 해부학적 위치를 확인하고자 하였다. 대상 및 방법: 정상 마우스의 $[^{18}F]$FDG 영상 획득 전 조건은 $16{\sim}22$시간 금식 하고 $30^{\circ}C$의 온도를 유지하며 $[^{18}F]FDG$ (7.4 MBq) 정맥 주사 후 서로 다른 마취제(Ketamine/Xylazine, Ke/Xy과 Isoflurane, Iso)로 $[^{18}F]FDG$ 섭취 60분 동안 유지한 후 20분간 $[^{18}F]FDG$ 소동물 PET 영상을 획득하였다. 혈중 포도당 농도를 보정한 포도당 표준 섭취 계수 영상을 이용하여 관심영역 대 배경비(lung to background ratio, L/B)를 구하여 평가하였다. C57BL/6 마우스에 B16-F10 세포를 정맥내 주사하여 제작한 폐전이 종양 마우스 모델은 정상 마우스의 영상 획득 조건과 동일한 조건에서 $[^{18}F]FDG$ 소동물 PET 영상을 획득하였으며, 임상 CT를 이용하여 획득된 해부학적 영상으로 폐 부위의 종양 위치를 확인하였다. 결과: 정상 마우스의 평균 혈중 포도당 농도는 Ke/Xy으로 마취한 군에서 $128.0{\pm}23.87\;mg/dL$이었으며 Iso으로 마취한 군에서는 $86.0{\pm}21.65\;mg/dL$로, Ke/Xy으로 마취한 군이 Iso로 마취한 군 보다 1.5 배 높은 혈중 포도당 농도를 나타내었다. 포도당 표준 섭취 계수 영상에서의 L/B는 Ke/Xy으로 마취한 군에서 $8.6{\pm}0.48$ 이었으며 Iso으로 마취한 군에서는 $12.1{\pm}0.63$로, Iso로 마취한 군이 Ke/Xy으로 마취한 군 보다 주변 정상조직과의 대조도가 높은 경향을 보였다. 폐 전이 종양 마우스에서는 Iso로 마취한 군이 Ke/Xy으로 마취한 군의 $[^{18}F]FDG$ 소동물 PET 영상보다 주변 조직의 $[^{18}F]FDG$ 섭취가 낮았다. 또한 해부학적 종양의 위치를 확인하기 위하여 임상 CT 영상과 융합한 결과 폐 전이 종양이 폐 부위에 위치함을 확인하였다. 결론: 마우스와 같은 소동물에서의 폐 부위 종양을 $[^{18}F]FDG$로 영상화하는데 있어서 금식, 온도유지, $[^{18}F]FDG$ 섭취 시간 동안의 마취제 조건 등을 고려하여야 하며, $[^{18}F]FDG$ 소동물 PET과 CT 영상의 융합은 폐 부위의 전이 종양을 확인하는데 유용할 것으로 기대된다.

I-131 MIBG와 F-18 FDG 섭취의 불일치를 보였던 악성 부신경절종 1례 (A Significant Discrepancy of Uptake between I-131 MIBG and F-18 FDG in a Patient With Malignant Paraganglioma)

  • 김종수;김현근;최규영;박형기;김은실;김윤권;김소연;김영중;이효진
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권3호
    • /
    • pp.247-251
    • /
    • 2007
  • A 38-year-old man who was diagnosed with malignant paraganglioma underwent computed tomography (CT) and I-131 metaiodobenzylguanidine (MIBG) san. CT showed extensive lymph node enlargement in right iliac area and retroperitoneum with severe hydronephrosis and mass on posterior bladder wall. However, I-131 MIBG scan didn't showed abnormal uptake. He also underwent F-18 fluorodeoxyglucose (FDG) positron emisson tomography/CT for localizing accurate tumor site. F-18 FDG PET/CT showed multiple metastases of left supraclavicular, hilar, mediastinal para-aortic, inguinal, right iliac lymph nodes, lung, vertebrae, and pelvis. There are a few reports showing that the F-18 FDG PET/CT is helpful for staging and localizing tumor site of patients who are diagnosed with negative on the MIBG scans. Thus, we report a case with paraganglioma which showed negative I-131 MIBG scan, but revealed multiple intense hypermetabolic foci in F-18 FDG PET/CT.

Basic principles and applications of $^{18}F$-FDG-PET/CT in oral and maxillofacial imaging: A pictorial essay

  • Omami, Galal;Tamimi, Dania;Branstetter, Barton F.
    • Imaging Science in Dentistry
    • /
    • 제44권4호
    • /
    • pp.325-332
    • /
    • 2014
  • A combination of positron emission tomography (PET) with $^{18}F$-labeled fluoro-2-deoxyglucose ($^{18}F$-FDG) and computed tomography ($^{18}F$-FDG-PET/CT) has increasingly become a widely used imaging modality for the diagnosis and management of head and neck cancer. On the basis of both recent literature and our professional experience, we present a set of principles with pictorial illustrations and clinical applications of FDG-PET/CT in the evaluation and management planning of squamous cell carcinoma of the oral cavity and oropharynx. We feel that this paper will be of interest and will aid the learning of oral and maxillofacial radiology trainees and practitioners.

PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가 (Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction)

  • 윤석환;김병진;문일상;이홍재
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.35-42
    • /
    • 2018
  • 양전자 방출 단층촬영에서 정량적 평가에 통상적으로 쓰이는 표준섭취계수(SUV : Standardized Uptake Value)는 종양의 병소와 병기의 진단 그리고 치료 성적 평가에 있어서 사용되고 있는 유용한 지표이다. 하지만 SUV는 환자의 체격, 검사까지의 시간, 부분용적 효과, 관심영역의 설정, 검사장비, 영상재구성 차이 등에 따라 변화 되므로 다양한 인자의 영향을 고려하여야만 한다. 그 중에서도 PET/CT 장비와 영상의 재구성 방법의 차이에 의한 SUV의 차이를 SIEMENS 사의 EQ PET을 이용하여 방사능의 차이를 보정 할 수 있게 되었다. 그러므로 본 연구에서는 phantom 실험과 FDG PET 임상영상의 SUVmax를 비교 하여 EQ PET을 적용함으로써, SUV의 변화를 평가 하고 EQ PET의 유용성에 대해서 검증해보고자 하였다. 본원의 3대의 PET/CT 장비인 Biograph true point 40, Biograph mCT 40, Biograph mCT 64 장비를 이용하여 $^{18}F-FDG$를 주입 한 NEMA IEC body phantom 영상을 획득 한 후 OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF의 알고리즘을 이용하여 영상을 재구성 하였다. 각각 재구성된 영상에서 관심영역의 방사능 농도를 측정한 후, EARL에서 권고하는 NEMA IEC body phantom의 방사능 농도의 회복계수 값을 비교하여 서로 다른 PET system 간에 방사능 농도의 차이를 줄일 수 있는 EQ filter 값을 산출 하였다. 산출한 EQ Filter 값을 장비와 영상 재구성에 따라 적용하여 팬텀의 회복계수와 61명의 폐암환자의 FDG PET 영상에서 종양의 SUVmax를 비교 분석 하였다. 3대의 PET/CT 장비에서 영상의 재구성 알고리즘을 달리하여 획득한 phantom의 영상의 6개구의 평균 변동계수는 EQ PET 적용 전 후의 값은 OSEM3D 재구성 영상에서 각각 0.05, 0.04 OSEM3D+TOF 재구성 영상에서는 각각 0.04, 0.03, OSEM3D+PSF 재구성 영상에서는 각각 0.04, 0.03, OSEM3D+PSF+TOF 재구성 영상에서는 각각 0.03, 0.02 값을 보여 EQ PET 적용 후 팬텀의 6개 구의 평균 변동계수는 감소하였다. 임상 영상 비교 에서는 폐암환자 종양의 SUVmax는 OSEM3D, OSEM3D+TOF, OSEM3D+PSF, OSEM3D+PSF+TOF 순으로 증가하였으며, EQ PET 적용 후 재구성 영상에 대한 SUVmax는 통계적으로 유의한 차이가 없었다(p=1.000). PET/CT 영상에서 서로 다른 PET/CT 장비와 영상의 재구성 방법의 차이에 의해 발생하는 방사능 농도의 차이를 EQ PET을 이용하여 측정함으로서 장비와 영상 재구성별 방사능 농도의 편차가 감소되었다. PET 영상에서 정량적 평가에 이용되는 SUV의 편차를 줄일 수 있어 종양의 병소와 병기의 진단, 그리고 치료 성적평가의 정량적 평가 신뢰도가 향상 될 것으로 사료된다.

$^{18}F$-FDG PET/CT 검사에서 이뇨제 사용여부에 따른 $^{18}F$-FDG 배설 특성 (Characteristic of $^{18}F$-FDG Excretion According to Use Diuretics in $^{18}F$-FDG of PET/CT)

  • 장동근;양승오;이상호;배종림;김정구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권2호
    • /
    • pp.151-156
    • /
    • 2012
  • $^{18}F$-fluorodeoxyglucose ($^{18}F$-FDG)는 상당한 양의 방사능이 신장과 비뇨기계에 저류 되어 영상의 질을 저하시키고 진단 성능을 저하시킨다. 이러한 $^{18}F$-FDG의 비뇨기계 저류를 막기 위해 이뇨제를 사용하여 검사를 진행하게 된다. 이때 사용되는 이뇨제가 영상에 미치는 영향과 $^{18}F$-FDG 배설률에 미치는 영향을 알아보고자 하였다. PET/CT 검사를 시행한 환자 중 신장의 원발성 종양 또는 전이 병변이 없는 환자를 대상으로 $^{18}F$-FDG와 함께 이뇨제를 주사한 그룹, 생리식염수를 주사한 그룹, $^{18}F$-FDG만을 주사 한 정상군 그룹으로 진행하였으며, 각 그룹의 관심영역을 설정하여 SUV를 측정하였다. 또한 정량적 분석을 위하여 $^{18}F$-FDG를 주사 후 이뇨제 투여 여부에 따른 SUV를 비교 평가하였다. SUV 측정에 따라 영상의 배후방사능이 감소된 영상을 얻을 수 있었으며 이뇨제 사용으로 배설된 소변의 양이 늘어났지만, 소변에 방사능량의 변화가 없는 상반된 결과가 나타났다. 따라서 이뇨제가 영상의 배후방사능을 줄일 수는 있지만 $^{18}F$-FDG 배설에는 영향을 미치지 못함을 확인 하였다.

18F-FDOPA Brain PET/CT 검사의 영상 대조도 분석 및 섭취 시간에 따른 SUV변화 고찰 (A Study on analysis of contrasts and variation in SUV with the passage of uptake time in 18F-FDOPA Brain PET/CT)

  • 서강록;이정은;고현수;류재광;남기표
    • 핵의학기술
    • /
    • 제23권1호
    • /
    • pp.69-74
    • /
    • 2019
  • $^{18}F$-FDOPA는 뇌 종양의 아미노산 대사를 추적하는 방사성 의약품이다. 본 연구의 목적은 뇌 종양의 아미노산 대사를 영상화 하여 악성 종양을 진단하는 $^{18}F$-FDOPA와 포도당 대사를 통한 $^{18}F$-FDG의 Brain PET/CT 검사 영상의 대조도 분석을 통해 병변의 검출 능력을 비교하고, $^{18}F$-FDOPA Brain PET/CT 검사에서 섭취 시간에 따른 SUV의 변화를 분석하여 최적의 영상 획득 시간을 알아보기 위함이다. $^{18}F$-FDOPA 와 $^{18}F$-FDG 두 영상에서 종양(Tumor)과 소뇌(Cerebellum)의 중심에 각각 약 $350mm^2$의 관심 영역을 설정하여 $SUV_{max}$를 측정하였고, 종양과 소뇌의 $SUV_{max}$ 비율(T/C ratio)을 산출하였고, $^{18}F$-FDOPA 투여 직후 30분 동안 획득한 리스트 수집 방식 데이터(List mode data)를 활용해 2분씩 15프레임으로 나눈 뒤 각 프레임 별로 종양과 소뇌 중심에 $SUV_{max}$를 측정하여 위와 동일한 방법으로 T/C ratio를 산출하여 분석하였다. 종양의 평균 $SUV_{max}$를 비교해 본 결과, $^{18}F$-FDOPA Brain PET/CT 검사에서 $4.2{\pm}0.8$, $^{18}F$-FDG Brain PET/CT 검사에서는 $5.6{\pm}0.7$ 이었다. 또한, T/C ratio는 $^{18}F$-FDOPA 검사에서 $2.1{\pm}0.7$, $^{18}F$-FDG 검사에서는 $1.1{\pm}0.4$ 이었으며, $^{18}F$-FDOPA의 $SUV_{max}$$^{18}F$-FDG보다 낮지만 T/C ratio는 높게 나타나 종양 구별 능력이 더욱 뛰어난 것을 알 수 있었다(t=-5.214, p=0.000). $^{18}F$-FDOPA의 섭취 시간에 따른 $SUV_{max}$와 T/C ratio를 분석한 결과, $SUV_{max}$와 T/C ratio의 Peak는 모두 6~8분에서 나타났다. 이를 토대로 본원에서 $^{18}F$-FDOPA Brain PET/CT 검사에서 활용하는 10~30분의 영상과 Peak가 나타나기 시작한 6~26분의 영상을 비교한 결과 SUV와 T/C ratio가 각각 0.2, 0.1 증가하였다. 추후 지속적인 연구를 통해 검사 소요시간의 단축 가능성과 추가적인 스캔 정보 활용을 통한 정확한 진단에도 도움이 될 것으로 사료된다.

PET/CT에서 방사성 의약품 주입량이 방사선 피폭에 미치는 영향분석: 초기연구 (Analysis of Relationship Between Injection Dose and Exposure Dose in PET/CT Scan: Initial Study)

  • 박훈희;유광열
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권4호
    • /
    • pp.351-357
    • /
    • 2011
  • PET/CT 검사에서 $^{18}F$-FDG가 가장 널리 이용되며, 장비의 물리적 특성에 따라 환자 주입 $^{18}F$-FDF량이 다르게 권고되고 있다. 또한 검사 특성상 방사선종사자와 환자의 접촉으로 인하여 방사선의 피폭이 불가피하기에 본 연구에서는 각기 다른 PET/CT 장비를 대상으로 환자에게 주입되는 $^{18}F$-FDG가 방사선종사자에게 미치는 피폭선량과의 관계를 분석하였다. 총 3대의 각각 다른 PET/CT(Scanner1(S1): 0.15 mCi/kg, Scanner2(S2): 0.17 mCi/kg, Scanner3(S3): 0.12 mCi/kg)를 대상으로 각 장비에 숙련도를 고려하여 총 6명의 방사선종사자를 5개월간 순환근무하였고, 하루에 검사하는 환자수를 일정하게 유지하였다. 또한 검사진행 방법을 유사하게 유지하고, 방사선종사자의 개인피폭선량계인 열형광유리선량계(TLD)를 매월 판독하여 분석하였다. 개인의 월별 평균 피폭선량은 방비에 따라 S1은 0.76 mSv, S2는 0.93 mSv, S3는 0.47 mSv였다. 피폭선량은 개인 최대 1.12 mSv, 최저 0.42 mSv로 숙련도와 경험에 따라 유의한 차이를 보였고, 또한 각 주입량에 따른 PET/CT의 종류에 따라 피폭선량은 유의한 상관관계를 나타냈다. 본 연구를 통하여 주입 $^{18}F$-FDG가 적을수록 방사선종사자의 피폭선량이 낮았다. 또한 개인 숙련도에 따라 피폭선량이 감소하였으나, 장비의 특성에 따라 적은 방사선의약품 주입량의 영향이 방사선종사자의 피폭선량을 현저하게 감소할 수 있기에 이에 대한 연구가 보다 활성화 되어야 할 것이다.