• Title/Summary/Keyword: FD

Search Result 865, Processing Time 0.031 seconds

An Analysis of CD Distortions in Simple FD/CD Transcoding Algorithm (FD/CD 트랜스코딩기법에서 CD에 의한 왜곡 분석)

  • 김진수;김재곤;강경옥;김진웅
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.105-108
    • /
    • 2003
  • In the framework of universal multimedia access, one challenge for video transmission (communication) is to deliver video content through heterogeneous network channels matching the diversity of client devices. As one of the many adaptation methods, media transcoding is commonly considered. Particularly, FD (Frame Dropping)/CD Coefficient Dropping) transcoding is used due to the low computational complexity and simple implementation. In this scheme, CD is simply implemented by truncating the high frequency AC DCT coefficient bits. But, the CD error tends to be propagated within single GOV. In this paper, we derive the distortion relationships between CD error and propagation error, and investigate the error characteristics by computer simulations. The CD error characteristics can be effectively used in the FD/CD transcoding scheme.

  • PDF

Phage Assembly Using APTES-Conjugation of Major Coat p8 Protein for Possible Scaffolds

  • Kim, Young Jun;Korkmaz, Nuriye;Nam, Chang Hoon
    • Interdisciplinary Bio Central
    • /
    • v.4 no.3
    • /
    • pp.9.1-9.7
    • /
    • 2012
  • Filamentous phages have been in the limelight as a new type of nanomaterial. In this study, genetically and chemically modified fd phage was used to generate a biomimetic phage self-assembly product. Positively charged fd phage (p8-SSG) was engineered by conjugating 3-aminopropyltriethoxysilane (APTES) to hydroxyl groups of two serine amino acid residues introduced at the N-terminus of major coat protein, p8. In particular, formation of a phage network was controlled by changing mixed ratios between wild type fd phage and APTES conjugated fd-SSG phage. Assembled phages showed unique bundle and network like structures. The bacteriophage based self-assembly approach illustrated in this study might contribute to the design of three dimensional microporous structures. In this work, we demonstrated that the positively charged APTES conjugated fd-SSG phages can assemble into microstructures when they are exposed to negatively charged wild-type fd phages through electrostatic interaction. In summary, since we can control the phage self-assembly process in order to obtain bundle or network like structures and since they can be functionalized by means of chemical or genetic modifications, bacteriophages are good candidates for use as bio-compatible scaffolds. Such new type of phage-based artificial 3D architectures can be applied in tuning of cellular structures and functions for tissue engineering studies.

In utero exposure to 2.3', 4.4', 5- Pentachlorobiphenyl (PCB 118) alters postnatal reproductive development in female rat

  • Kim, Soon-Sun;Rhee, Gyu-Seek;Kim, So-Hee;Sohn, Kyung-Hee;Kwack, Seung-Jun;Lee, Rhee-Da;Park, Chul-Hoon;Kil, Kwang-Sup;Choi, Kwang-Sik;Park, Kui-Lea
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.296.2-296.2
    • /
    • 2002
  • Our previous study demonstrated that 2.3', 4.4'. 5- Pentachlorobiphenyl (PCB 118) showed an antiestrogenic activity in vitro and in vivo. In the present study. we examined the effect of PCB 118 on postnatal reproductive development in female rats. PCB 118 (0.001. 0.01 or 0.1 mg/kg/day) was administered to pregnant female SD rats from gestation day (GO) 6 to 18 via subcutaneous injection. and developmental parameters such as vaginal opening were determined. PCB 118 significantly delayed vaginal opening of female offsprings at dose of 0.1 ${\mu}g$/kg/day. whereas had no effects on body weights. In addition. in utero treatment of PCB 118 caused significant decreases in serum levels of E2, T3 and T4 in female oftsprings at certain doses on postnatal day (PND) 22. Our data of results indicate that in utero exposure to PCB 118 may postnatal reproductive development in female rat through its antiestrogenic activity.

  • PDF

Characterization of Volatile Components according to Fermentation Periods in Gamdongchotmoo Kimchi (발효기간에 따른 감동젓무 김치의 휘발성 향기 성분 특성)

  • Yoon, Mi-Kyung;Kwon, Mi-Jung;Lee, Sang-Mi;Kim, Ji-Won;Cho, Mi Sook;Lee, Jong-Mee;Kim, Young-Suk
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.497-502
    • /
    • 2008
  • The volatile components in Gamdongchotmoo kimchi, unfermented and fermented for 3 or 25 days, were extracted via solvent-assisted flavor evaporation (SAFE), and then analyzed via gas chromatography/mass spectrometry (GCMS). A total of 57 components, including 14 S-containing compounds, 22 terpene hydrocarbons, 13 aliphatic hydrocarbons, 4 alcohols, and 4 miscellaneous components, were detected in Gamdongchotmoo kimchi. Among them, the S-compounds were quantitatively dominant. The aroma-active compounds were also determined via gas chromatography-olfactometry (GC-O), using aroma extract dilution analysis (AEDA). A total of 16 aroma-active compounds were detected via GC-O. The most intense aroma-active compounds in Gamdongchotmoo kimchi included 4-isothiocyanato-1-butene ($Log_3$ FD factor 7, rancid), an unknown($Log_3$ FD factor 7, spicy) and another unknown ($Log_3$ FD factor 7, seasoning-like). In addition, other aroma-active compounds, including dimethyldisulfide ($Log_3$ FD factor 6, rotten onion-like/sulfury), 2-vinyl-[4H]-1,3-dithiin ($Log_3$ FD factor 5, spicy/garlic-like), and an unknown ($Log_3$ FD factor 5, rancid/cheese-like) might be crucial to the flavor characteristics of Gamdongchotmoo kimchi.

Development of a Food Retention Questionnaire for Functional Dyspepsia and the Analysis of Its Reliability and Validity (기능성소화불량의 식적설문지 개발과 신뢰도 및 타당도 검정)

  • Hwang, Mi-ni;Ha, Na-yeon;Ko, Seok-jae;Park, Jae-woo;Kim, Jin-sung
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.3
    • /
    • pp.390-408
    • /
    • 2019
  • Objectives: Several pattern diagnosis questionnaires have been developed to objectify the process of pattern diagnosis in Korean medicine. In this context, this study aimed to develop a food retention questionnaire for functional dyspepsia (FRQ-FD) by modifying the previously developed food retention questionnaire (FRQ) and to verify its reliability and validity. Furthermore, this study aimed to identify the optimal cut-off value of the FRQ-FD for standardization and use in clinical situations. Methods: To develop the FRQ-FD, we extracted the major symptoms of food retention pattern for functional dyspepsia from Chinese/Korean medicine textbooks and requested an importance survey from experts using the Delphi method. The first draft of the FRQ-FD was composed of 25 questions comprising 8 questions from the textbooks and the Delphi method and 17 questions from the FRQ already developed in 2013. To analyze its reliability, validity, and optimal cut-off value, 60 subjects were enrolled in this study from June 25 to August 13, 2018. Thirty patients were diagnosed as both functional dyspepsia and food retention pattern, and 30 healthy participants were not. All participants were requested to fill up the FRQ-FD, Stomach Qi Deficiency Questionnaire (SQDQ), Scale for Stomach Qi Deficiency pattern (SSQD), visual analog scale (VAS) for dyspepsia, Nepean Dyspepsia Index-Korean version (NDI-K), and functional dyspepsia-related quality of life (FD-QoL). Results: No statistically significant differences were found in sex distribution, age, and body mass index between the patient group and the control group. As five questions affected the reliability negatively and three questions affected the clinical validity negatively, we decided to exclude the eight questions upon further investigation. The Cronbach's ${\alpha}$ coefficient of the revised FRQ-FD (17 items) was 0.899, and its clinical validity was verified. Construct validity was analyzed by factor analysis and produced five factors. Statistically significant positive correlations were found between the revised FRQ-FD and the other dyspepsia scales, namely, SQDQ, SSQD, VAS, NDI-K, and FD-QoL. VAS and NDI-K especially had strong positive correlations with FRQ-FD. Conclusions: The FRQ-FD developed in this study can provide fundamental reliability and validity for a pattern diagnosis questionnaire. FRQ-FD can help to diagnose food retention pattern in functional dyspepsia patients. Further studies are required to inspect several statistical factors.

Development of a Phlegm Pattern Questionnaire for Functional Dyspepsia and Analysis of Its Reliability and Validity (기능성소화불량에 대한 담음 변증설문지 개발과 신뢰도 및 타당도 검정)

  • Baek, So-young;Ha, Na-yeon;Ko, Seok-jae;Park, Jae-woo;Kim, Jin-sung
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.4
    • /
    • pp.563-582
    • /
    • 2020
  • Objectives: The aim of this study was to develop a Phlegm Pattern Questionnaire for Functional Dyspepsia (PPQ-FD) by modifying a previously developed Phlegm Pattern Questionnaire (PPQ) and to verify its reliability and validity. Further objectives were to obtain the optimal cut-off value for the PPQ-FD for standardization and for clinical use. Methods: The PPQ-FD was developed by extracting the major symptoms of the phlegm pattern in functional dyspepsia and by using the Delphi method to administer a requested importance survey to experts. The reliability, validity, and optimal cut-off value of the PPQ-FD were analyzed by enrolling a total of 60 subjects in this study. Thirty patients were diagnosed with both functional dyspepsia and phlegm pattern and thirty patients were diagnosed with only functional dyspepsia. All participants were requested to fill out the PPQ-FD. Results: No statistically significant differences were detected in the two groups for sex distribution, age, or body mass index. Five of the survey questions negatively affected its reliability; therefore, we decided to exclude those five questions on further inspection. The Cronbach's α coefficient of the revised PPQ-FD was 0.853, and clinical validity was verified. Construct validity was analyzed by factor analysis and identified four factors. Statistically significant positive correlations were found between the revised PPQ-FD and other dyspepsia scales, such as the SQDQ, SSQD, VAS, NDI-K, and FD-QoL scales. The VAS had particularly strong positive correlations with the PPQ-FD. Conclusions: The PPQ-FD developed in this study has fundamental reliability and validity for use as a pattern-diagnosis questionnaire. The PPQ-FD can help to diagnose the phlegm pattern in patients with functional dyspepsia.

Comparison and Performance analysis of Wavelet OFDM system and FD-OFDM (웨이블릿 OFDM 시스템과 FD-OFDM 시스템 성능 비교 분석)

  • Lee, Junseo;Kim, Ji-Hoon;Kim, Whanwoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.34-42
    • /
    • 2013
  • In this paper, we compare the performance of wavelet OFDM (Orthogonal Frequency Division Multiplexing) and FD-OFDM(Frequency diversity OFDM) system with conventional OFDM system. Wavelet OFDM system uses wavelet transform rather than Fourier transform and contains intermediate characteristics of CDM (Code Division Multiplexing) and OFDM. In wavelet OFDM system, inter-symbol interference (ISI) can be suppressed effectively and adjacent channel interference can be also minimized well. In FD-OFDM system, each parallel branch symbol is multiplied by the orthogonal sequence and distributed into all sub-carriers. Then, each sub-carrier transmits information composed of the symbol components of all parallel branches in the given frame. FD-OFDM contains the frequency diversity characteristic and, therefore, FD-OFDM can be robust to the narrowband interference. For the comparison among different systems, BER (Bit-Error Rate) performances are evaluated in the presence of narrow-band interference and a harmonic noise channel. From the evaluation results, compared to the conventional OFDM, wavelet OFDM and FD-OFDM shows better robustness against the interference and, especially, wavelet OFDM is the most robust in harmonic noise channel.

A Clinical Study on the Relationship between Functional Dyspepsia (FD) and Biosignals from Heart Rate Variability (HRV) and Yangdorak Diagnosis (기능성 소화불량증과 심박변이도 및 양도락과의 상관성 연구)

  • Yoon, Seung-Woo;Park, Jae-Woo
    • The Journal of Korean Medicine
    • /
    • v.28 no.2 s.70
    • /
    • pp.80-92
    • /
    • 2007
  • Objectives : Functional dyspepsia (FD) is one of the most common gastrointestinal diseases. Nevertheless, there are many unknown mechanisms of autonomic functioning in FD patients. This study was designed to investigate the relationship between FD and biosignals from heart rate variability (HRV) and Yangdorak diagnosis. Methods : 32 patients (22 female, 10 male; mean age 40) and 32 healthy volunteers (21 female, 11 malemean; age 38) participated in this study. First gastrointestinal symptoms rating scale (GSRS) was assessed by questionnaires in both groups to evaluate the types of gastrointestinal symptoms. Second, HRV and Yangdorak diagnosis were measured in both groups. Results : 1. The FD group in this study mainly had the complaint of 'bloating' symptoms. 2. There was statistically no significant difference between Yangdorak (total average and 24 acupoints) and HRV values except logarithmic low-frequency band (lnLF) and total power (TP) in frequency domain. 3. There was statistically no significant relationship between HRV and Yangdorak in either group. However, most Yangdorak values were positively related with some HRV values (low-frequency, low-frequency/high-frequency ratio and high-frequency, etc) in the control group. Conclusions : FD patients had relatively lesser sympathetic domain than healthy subjects, indicated by decreased lnLF and TP. Particularly, there were positive relationships and significant differences between Yangdorak and HRV in young healthy subjects. This suggests that biosignals from HRV may be a useful method that can differentiate FD from healthy state in those of young age.

  • PDF

Design of a Frequency Domain Equalizer Algorithm for MBOK DS-UWB System (MBOK DS-UWB 시스템을 위한 주파수 영역 등화기 알고리즘의 설계)

  • Kang, Shin-Woo;Im, Se-Bin;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.10A
    • /
    • pp.1034-1041
    • /
    • 2007
  • In this paper, we propose a FD USE (frequency domain minimum mean square error) equalizer algorithm for MBOK DS-UWB (M-ary bi-orthogonal keying direct sequence UWB) systems considered as a PHY proposal for high-speed wireless communication in IEEE 802.15.TG3a. The conventional FD MMSE equalization scheme has a structural limit due to insertion of the cyclic prefix (CP) in all transmit packets, but the proposed scheme is able to equalize the channel effect without CP. In order to overcome channel estimation error by multipath delay, we introduce a moving FFT and a moving average scheme. Compared with conventional FD MMSE equalizer and the traditional TD (time domain) MMSE-RAKE receiver, the proposed FD MMSE equalizer has better BER performance and we demonstrate this result by computer simulation.

Long-term Statistical Analysis of the Simultaneity of Forbush Decrease Events at Middle Latitudes

  • Lee, Seongsuk;Oh, Suyeon;Yi, Yu;Evenson, Paul;Jee, Geonhwa;Choi, Hwajin
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.1
    • /
    • pp.33-38
    • /
    • 2015
  • Forbush Decreases (FD) are transient, sudden reductions of cosmic ray (CR) intensity lasting a few days, to a week. Such events are observed globally using ground neutron monitors (NMs). Most studies of FD events indicate that an FD event is observed simultaneously at NM stations located all over the Earth. However, using statistical analysis, previous researchers verified that while FD events could occur simultaneously, in some cases, FD events could occur non-simultaneously. Previous studies confirmed the statistical reality of non-simultaneous FD events and the mechanism by which they occur, using data from high-latitude and middle-latitude NM stations. In this study, we used long-term data (1971-2006) from middle-latitude NM stations (Irkutsk, Climax, and Jungfraujoch) to enhance statistical reliability. According to the results from this analysis, the variation of cosmic ray intensity during the main phase, is larger (statistically significant) for simultaneous FD events, than for non-simultaneous ones. Moreover, the distribution of main-phase-onset time shows differences that are statistically significant. While the onset times for the simultaneous FDs are distributed evenly over 24-hour intervals (day and night), those of non-simultaneous FDs are mostly distributed over 12-hour intervals, in daytime. Thus, the existence of the two kinds of FD events, according to differences in their statistical properties, were verified based on data from middle-latitude NM stations.