• Title/Summary/Keyword: FCU

Search Result 40, Processing Time 0.026 seconds

Electromyographic Analysis of Wrist Flexors by the Shape of Ultrasound Head (초음파 도자의 모양에 따른 손목굽힘근의 근전도 분석)

  • Kim, Won-Ho;Kim, Jong-Man;Park, Hyung-Ki;Park, Eun-Young
    • Physical Therapy Korea
    • /
    • v.14 no.3
    • /
    • pp.9-15
    • /
    • 2007
  • The purpose of this study was to investigate electromyographic activities of the flexor digitorum superficialis (FDS) and the flexor carpi ulnaris (FCU) by the shape of the ultrasound head. Twelve healthy subjects participated and performed ultrasound therapy with a round head and a long handled head during each 5-minute application. Electromyographic activities of the FDS and FCU were recorded by surface electrodes and normalized by maximal voluntary isometric contraction (MVIC) values. There was no difference in the muscular fatigue of FDS and FCU as determined by the shape of the ultrasound head (p>.05). Without the shape of head, the mean power frequency decreased with the time. There also was no difference in %MVIC of the FDS and FCU as determined by the shape of the ultrasound head (p>.05), but the force exerted exceeded 20%MVIC. There was however a significant difference in the amount of cumulative workload of the FDS and FCU as determined by the shape of ultrasound head (p<.05). The workload was however not affected by the shape of the ultrasound head. Constant static grasp of ultrasound transducer head during ultrasound therapy is considered a high risk factor of work-related musculoskeletal disease.

  • PDF

Speed Control of Induction Motor Drive for FCU Using TMS320LF2406 DSP controller (TMS320LF2406 DSP를 이용한 FCU용 유도 전동기 속도제어)

  • Choi Woo-Suk;Kim Lee-Hun;Park Kyu-Hyun;Won Chung-Yuen;Lee Sang-Suk;Choi Chang-Young
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.3-6
    • /
    • 2001
  • This paper designs a drive for high efficiency of the 3-phase IM (induction motor) for FCU(Fan Coil Unit). The speed control system of 3-phase IM for FCU has been implemented by a TMS320LF2406 DSP chip. The DSP TMS320LF2406, which include the most peripheral circuit for control of the Industrial motor suitable for AC motor drive. This type of the controller can be obtained low cost and high reliance. The proposed drive system of the 3-phase IM for the FCU is verified by simulation. The results show the speed control characteristics of the control strategy Proposed for 3-Phase IM drive.

  • PDF

The Influence of the Pattern of Gripping the Ultrasound Head on the Activity of Upper Limb Muscles (초음파 도자를 쥐는 방법이 팔 근육의 근활성도에 미치는 영향)

  • Choi, Seok-Ho;Yi, Chung-Hwi;Jeon, Hye-Sun;Lee, Jeong-Weon
    • Physical Therapy Korea
    • /
    • v.20 no.2
    • /
    • pp.28-37
    • /
    • 2013
  • This study examined differences in the activity of upper limb muscles according to how an ultrasound head is gripped. Twenty-two adult males were participated in the study. Each participant was asked to apply ultrasound treatment on to a lump of pork meat by two different ultrasound head grip patterns: spherical and cylindrical grips. Muscle activity was measured in the extensor carpi radialis longus (ECRL), flexor carpi ulnaris (FCU), and pronator teres (PT), triceps brachii (TB), middle deltoid (MD), and upper trapezius (UT) muscles. There were no significant differences in the EMG signals of any muscle according to the ultrasound head grip pattern (p>.05). There were significant differences in the EMG signal of each type of muscle (p<.05). The EMG signal of UT was the lowest and that of TB was lower than ECRL and FCU. There were interactions between ECRL and FCU, between ECRL and PT, between FCU and ECRL, and between FCU and MD. The EMG signal of ECRL using the cylindrical head was low and that of FCU with the cylindrical head was high, while the opposite was the case with the spherical head ($p_{adj}$ <.05/15). The results of this study indicate that the wrist muscles worked actively when the participants applied ultrasound therapy using both spherical and cylindrical heads. A spherical head might induce imbalanced muscle activity among the wrist muscles, leading to deviation of the wrist joint. Therefore, the cylindrical head is recommended for ultrasound therapy because it produced a constant, repeated force.

Location of Ulnar Nerve Branches to the Flexor Carpi Ulnaris during Surgery for Cubital Tunnel Syndrome

  • Won Seok, Lee;Hee-Jin, Yang;Sung Bae, Park;Young Je, Son;Noah, Hong;Sang Hyung, Lee
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.1
    • /
    • pp.90-94
    • /
    • 2023
  • Objective : Cubital tunnel syndrome, the most common ulnar nerve entrapment neuropathy, is usually managed by simple decompression or anterior transposition. One of the concerns in transposition is damage to the nerve branches around the elbow. In this study, the location of ulnar nerve branches to the flexor carpi ulnaris (FCU) was assessed during operations for cubital tunnel syndrome to provide information to reduce operation-related complications. Methods : A personal series (HJY) of cases operated for cubital tunnel syndrome was reviewed. Cases managed by transposition and location of branches to the FCU were selected for analysis. The function of the branches was confirmed by intraoperative nerve stimulation and the location of the branches was assessed by the distance from the center of medial epicondyle. Results : There was a total of 61 cases of cubital tunnel syndrome, among which 31 were treated by transposition. Twenty-one cases with information on the location of branches were analyzed. The average number of ulnar nerve branches around the elbow was 1.8 (0 to 3), only one case showed no branches. Most of the cases had one branch to the medial head, and one other to the lateral head of the FCU. There were two cases having branches without FCU responses (one branch in one case, three branches in another). The location of the branches to the medial head was 16.3±8.6 mm distal to the medial epicondyle (16 branches; range, 0 to 35 mm), to the lateral head was 19.5±9.5 mm distal to the medial epicondyle (19 branches; range, -5 to 30 mm). Branches without FCU responses were found from 20 mm proximal to the medial condyle to 15 mm distal to the medial epicondyle (five branches). Most of the branches to the medial head were 15 to 20 mm (50% of cases), and most to the lateral head were 15 to 25 mm (58% of cases). There were no cases of discernable weakness of the FCU after operation. Conclusion : In most cases of cubital tunnel syndrome, there are ulnar nerve branches around the elbow. Although there might be some cases with branches without FCU responses, most branches are to the FCU, and are to be saved. The operator should be watchful for branches about 15 to 25 mm distal to the medial epicondyle, where most branches come out.

A study on the design of air conditioning system in the mushroom cultivation greenhouse (버섯재배사의 공조시스템 설계에 대한 연구)

  • Ryu, Kyung-Jin;Son, Jae-Hwan;Han, Chang-Woo;Nah, Kyu-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.743-750
    • /
    • 2017
  • It is important to ensure a uniform temperature distribution in greenhouses for the mushroom cultivation. The air temperature of the mushroom cultivation greenhouse is made uniform by supplying a constant air temperature with the underground air. The mushroom cultivation array in a greenhouse in seven columns and four rows can make smooth air flows between the rows and prevent air differences between the top and bottom. The buoyancy effect in the entering air of 0.5m/s based on following density difference depending on initial internal temperature needs to be considered. The locations of the Fan Coil Unit (FCU) and fan were defined through flow analysis in a greenhouse to distribute the optimal uniform temperature. In this study, the air conditioning system of a greenhouse with a sandwich heat insulting panel shape which is composed of a FCU and fan was designed by flow analysis. A relatively uniform temperature distribution can be formed because the circulation path of air becomes longer in the different locations of the FCU (inlet) and fan (outlet) through the internal temperature and flow analysis. The cultivation and quality uniformity of the mushrooms could be promoted through these environmental improvements.

Dynamic Simulation of Annual Energy Consumption in an Office Building by Thermal Resistance-Capacitance Method

  • Lee, Chang-Sun;Choi, Young-Don
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.1-13
    • /
    • 1998
  • The basic heat transfer process that occurs in a building can best be illustrated by an electrical circuit network. Present paper reports the dynamic simulation of annual energy consumption in an office building by the thermal resistance capacitance network method. Unsteady thermal behaviors and annual energy consumption in an office building were examined in detail by solving the simultaneous circuit equations of thermal network. The results are used to evaluate the accuracy of the modified BIN method for the energy consumption analysis of a large building. Present thermal resistance-capacitance method predicts annual energy consumption of an office building with the same accuracy as that of response factor method. However, the modified BIN method gives 15% lower annual heating load and 25% lower cooling load than those from the present method. Equipment annual energy consumptions for fan, boiler and chiller in the HVAC system are also calculated for various control systems as CAV, VAV, FCU+VAV and FCU+CAV. FCU+CAV system appears to consume minimum annual energy among them.

  • PDF

Analysis of energy consumption of office building by thermal resistance-capacitance method (열저항-열용량법에 의한 사무실용 건물의 소비에너지 해석)

  • Lee, C.S.;Choi, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 1997
  • This paper reports the dynamic analysis of energy consumption for an office building by heat resistance-capacitance method. If a building is divided into several wall components and the wall components is replaced by one thermal capacitance and several thermal resistances, the building becomes an electric circuit. By solving the simultaneous equations of the circuit, the dynamic heat transfer characteristics and the energy consumption rate of the building were predicted. Accuracy of modified BIN method was evaluated by the present resistance-capacitance method. The result shows that modified BIN method overpredicts the heating load of the office building 15%. Annual energy consumptions of equipments(fan, boiler, chiller) for various ventilating control system(CAV, VAV, FCU+VAV, FCU+CAV) were compared. FCU+CAV shows the minimum annual energy consumption.

  • PDF

Estimation of the Required Number of Fan Coil Unit for Surplus Solar Energy Recovery of Greenhouse (온실의 잉여 태양에너지 회수용 FCU 소요대수 검토)

  • Yun, Sung-Wook;Choi, Man Kwon;Kim, Ha Neul;Kang, Donghyeon;Lee, Siyoung;Son, Jinkwan;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.83-88
    • /
    • 2016
  • In this study, previously reported surplus solar energy-related study result and current status of fan coil unit (FCU) for cooling and heating installed in the current sites were briefly examined and then a method to determine the number of FCUs required to recover surplus solar energy was schematically proposed to provide basic data for researchers and technical engineers in this field. The maximum, mean, and minimum outside temperatures during the experiment period were about $28.2^{\circ}C$, $4.4^{\circ}C$, and $-11.5^{\circ}C$, respectively. The horizontal surface solar radiation level outside the greenhouse was in a range of $0.8-20.5MJ{\cdot}m^{-2}$ and mean and total solar radiation were $10.8MJ{\cdot}m^{-2}$ and $1,187.5MJ{\cdot}m^{-2}$. The mean temperature and relative humidity in the greenhouse during the daytime were in a range of 18.8-45.5 and 53.5-77.5%. The total surplus solar energy recovered from the greenhouse during the experiment period was approximately 6,613.4MJ, which could supplement about 6.7% of the total heating energy 98,600.2 MJ. In addition, the number of FCUs installed for heating varies case to case, although similar FCUs are used. Thus, it is necessary to study the installation height, orientation and installation distance as well as the appropriate number of FCUs from the efficient and economical viewpoints. The required numbers of FCUs for surplus solar energy recovery were 8.4-10.9units and 6.1-8.0units based on air mass and circular flow rate that passed through the FCUs. Considering calculation methods and the risks such as efficiency and use environments of FCUs, it was found that about nine units (one unit per $24m^3$ approximately) needed to be installed. The required number of FCUs for surplus solar energy recovery was around one unit per $24m^3$ approximately.