• 제목/요약/키워드: FCAW

검색결과 155건 처리시간 0.028초

FCAW에 의한 590MPa급 고장력압력용기강의 초층편면용접부에서 발생하는 고온균열 (Solidification Crackin in Root Pass for One-side Welding of 590MPa Class Steel for Pressure Vessels by FCAW)

  • 김우열;한일욱;유덕상;방한서;안용식;박화순
    • Journal of Welding and Joining
    • /
    • 제17권5호
    • /
    • pp.47-54
    • /
    • 1999
  • It is well known that solidification cracking often occurs in welds of root pass for one-side welding under the conditions of high welding currents and speeds. In this study, the solidification in 590MPa class steel for pressure vessels SPPV490 was investigated by using flux-cored arc welding(FCAW) with 4 types of welding wires and welding conditions of 200∼280A and 2.8∼ 4.2mm/sec. In order to compared the result of cracking in SPPV490, 0.2%C steel for welded structure of SWS400 and 0.45%C steel for machine structural SM45C were also used as base metals. As the results, all the cracks formed in some welding conditions were observed near the center of weld bead. The solidification cracks were generally initiated near the upper surface of bead and propagated toward the inner part. The solidification cracking generally increased with welding current and welding speed in the same base metal and welding material. In cracking susceptibility, SPPV490 showed higher cracking susceptibility than SWS400 in all welding conditions and welding materials. It was considered that cracking susceptibility could not be evaluated with the hardness of weld metals. The cracking ratio increased with decreasing of a/b(a and b; the width of the upper surface and the back surface of the bead) as shape factor of bead. The cracking tendency with shape factor of bead was extended under the condition of higher welding currents.

  • PDF

석유시추용 인코넬 625강의 FCAW용접에 의한 고온인장 특성에 관한 연구 (A Study on High Temperature Tensile Property of Inconel 625 for Petroleum Application by Flux cored Arc Welding Process)

  • 박경동;안도경;진영범
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.352-355
    • /
    • 2004
  • Inconel 625 is useful in variety of industrial applications because of the resistance to attack in various corrosive media at temperatures from $200^{\circ}C$ to over $1090^{\circ}C$, in combination with good law- and high temperature mechanical strength. Rencently, this material is also used widely in offshore processing piping in order to extend the maintenance tenn and improve the quality of anti-corrosion. In general, high quality weldments for this material are readily produced by commonly used processes. Not all processes are applicable to this material group, Ni-alloys. Metallurgiad characterictics or the unavailability of matching, position or suitable welding processes. Nowadays, the flux cored wire is developed and applied for the better productivity in several welding position including the vertical position. in this study, the weldability and weldment characteristics of inconel 625 are considered in FCAW weld associated with the several shielding gases($80\%Ar\;+\;20\%\;CO_2,\;50\%Ar\;+\;50\%\;CO_2,\;100\%\;CO_2$) in viewpoint of welding productivity.

  • PDF

해양 구조물용 강재 FCAW 용접부의 파괴인성 특성에 관한 연구 (A Study on the Fracture Toughness Characteristics of FCAW Weldment of Steel for Offshore Structures)

  • 강성원;김명현;김용빈;신용택;이해우
    • Journal of Welding and Joining
    • /
    • 제22권6호
    • /
    • pp.57-63
    • /
    • 2004
  • Fracture toughness is an important parameter in designing offshore structures to ensure resistance to fracture at various temperatures. In this study, a series of experiments is carried out to obtain fracture toughness values (CTOD) of API 2W Gr.50B, welded using FCAW(Flux Cored Arc Weld). In particular, a comparison of absorbed impact energy and CTOD values are made with respect to two different welding groove shapes; double-V-groove and double-bevel-groove. Charpy impact tests are performed for specimens sampled near the root gap, and CTOD tests are carried out for three point bending specimens having the notch at weld zone. While Charpy impact test result is determined to be a good qualitative measure of fracture toughness, no quantitative correspondence between impact absorbed energy and CTOD values was found. Based on the experiment, it is observed that double-V-groove welds give lower transition temperature than those of double-bevel-groove.

Flux Cored Arc용접용 아크센서의 개발 및 이를 이용한 용접선 추적에 관한 연구 (A Study on the Development of Arc Sensor for Flux Cored Arc Welding Process and its Application for Seam Tracking)

  • 김수영;이승영;나석주
    • Journal of Welding and Joining
    • /
    • 제10권4호
    • /
    • pp.190-198
    • /
    • 1992
  • Among the variety of welding processes available, the flux cored arc welding is one of the most frequently used process, because of its wide range of application and high productivity. The weld joint tracking is indispensable to improve the flexibility of the arc welding robot application for the flux cored arc welding (FCAW) process. In this study, an arc sensor which utilizes the electrical signal obtained from the welding arc itself was developed for weld joint tracking in FCAW. Because a model of the welding arc in flux cored arc welding was required to develop the arc sensor, a mathematical model was proposed by analysing the welding arc behaviour, and also an experimental model by using the factorial experiment and least square method. For overcoming the fluctuation in the welding current signal during tracking the weld joint, it was fitted to a curve which is inversely proportional to a trace of tip-to-workpiece distance by using the quadratic curve-fitting method.

  • PDF

필렛용접에서의 결함발생 원인 분석 및 저감 방안 (An Analysis of the Cause of Porosity Generation and Reduction Plan in Fillet Welding)

  • 최기영;김영필;김경주;김대순;배상득
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2006년도 특별논문집
    • /
    • pp.128-133
    • /
    • 2006
  • Generally, porosity which was formed by pyrolysis of the primer is usually generated in the weld metal in respect of increase of the welding speed. in order to analyze the cause of porosity generation, this study was performed using FCAW(flux cored arc welding) process for three kinds of inorganic.zinc primer. in addition the evaluation by influence of welding method on porosity generation is conducted to compare between FCAW and MAG(metal active gas) welding with the same inorganic zinc primer. As the result of this investigation, not only primer of lower organic binder and zinc but also FCAW process than MAG in fillet welding have been verified the excellent resistance to the porosity generation for horizontal fillet welding.

  • PDF

극후판 다층 FCAW 맞대기 용접부의 잔류응력 특성에 관한 연구 (A Study of the Residual Stress Characteristics of FCAW Multi-Pass Butt Joint for an Ultra-Thick Plate)

  • 방희선;방한서;이윤기;김현수;이광진
    • 한국해양공학회지
    • /
    • 제24권2호
    • /
    • pp.62-66
    • /
    • 2010
  • The goal of this work is to establish the reliability of FCA welded joints for high strength EH36-TMCP ultra thick plate. For this, heat conduction and thermo elasto-plastic analyses have been conducted on a multi-pass, X-groove, butt-joint model to clarify the thermal and mechanical behavior (residual stresses, magnitude of the stresses, and their production and distribution mechanisms) of the weld joint. In addition, the results of the welding residual stress obtained from thermo elasto-plastic analysis was verified and compared with results obtained by XRD analysis.

FCAW를 이용한 SM45C의 혼합가스비율에 따른 전류파형 및 용접특성 연구 (Analysis on the Characteristic of Current Waveform and Welding for SM45C Using FCAW According to Gas Mixture Ratio)

  • 이종훈;임병철;박상흡
    • 한국생산제조학회지
    • /
    • 제23권6호
    • /
    • pp.618-623
    • /
    • 2014
  • This study, analyzed the waveform and mechanical properties of flux cored arc Welding on SM45C. $CO_2$ 10% + Ar 90% shows the lowest standard deviation and shunt ratio at which the arc was most stable. $CO_2$ 10% + Ar 90% is equal to $CO_2$ 20% + Ar 80%. therefore, $CO_2$ 20% + Ar 80% is the best of mixture gases. The hardness test result for the gas mixture ratio of $CO_2$ 10% + Ar 90% was HV 249.7 which is the highest measured value. According to tensile test results, the tensile strength increased with increasing Ar in the mixture gas. This was because of the inertness of the argon, which does not combine with other elements, causing $CO_2$ to combine with pearlite and ferrite and decreasing the maximum tensile strength. Microstructural examination results show that with increasing Ar, ferrite generation decreases while the mild microstructure increases which influences the hardness.

선체구조용강의 용접방법에 따른 용접부의 피로균열전파특성 연구 (A Study on the Fatigue Crack Growth Characteristics of the Welded Part According to the Welding Method of Ship Structural Steel)

  • 박경동;기우태;이주영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권4호
    • /
    • pp.385-393
    • /
    • 2007
  • The strength evaluation of the most weakest junction part is required for the safety design of all structures. Most of all. in order to enhance the reliability and safety of the welding part. whose use is the highest, it is very important to establish the efficient structure manufacturing technology by studying and investigating the evaluation of fatigue strength in various environments. This study analyzed the relations of da/dN, and th according to the welding methods of SMAW, FCAW, and SAW. In the stage II. the value of stress intensity factor range was the highest in SMAW welding method of stress ration R=0.1, and appeared under the sequence of FCAW and SAW and as the completion section of stress intensity factor was low, threshold stress intensity factor was lowly formed in da/dN - The fatigue life of each welding method is sensitively worked in high stress ratio. judging from the fact that the width of life reduction increases in the high stress ratio zone compared to the width of life reduction in the low stress ratio zone. In the fatigue limit of welding methods before corrosion. the welding of SMAW and FCAW shows the same fatigue limit compared to Base metal, and SAW holds the lowest fatigue limit value.

FCAW에서 용접금속 확산성수소량에 미치는 용접변수 영향의 정량적 해석 (Quantitative Analysis on the Effects of Welding Parameters on Diffusible Hydrogen Contents in Weld Metal Produced by FCAW Process)

  • 한동우;방국수;정홍철;이종봉
    • Journal of Welding and Joining
    • /
    • 제28권2호
    • /
    • pp.54-59
    • /
    • 2010
  • The effects of welding parameters such as contact tip-to-work distance (CTWD), voltage, and current on the weld metal diffusible hydrogen contents (HD) were investigated and rationalized by the calculation of heating time and amount of heat generated in the extension length of flux cored wire. As CTWD increased from 15 to 25mm, HD decreased from 8.46 to 5.45mL/100g deposited metal. Calculations showed that, with an increase of CTWD, the amount of heat generated increased from 46 to 92J in addition to an increase of heating time. Increase of current from 250 to 320A, however, gave little variation of HD. It showed that no significant change in the amount of heat generated was found, and heating time was decreased with an increase of current. It also showed that CTWD is more influential than voltage in relatively lower heat input ranges, while voltage is more in higher input ranges

HSA800 후판재의 맞댐용접부 인장강도 실험 (Tensile Testing of Groove Welded Joints Joining Thick-HSA800 Plates)

  • 이철호;김대경;한규홍;박창희;김진호;이승은;김도환
    • 한국강구조학회 논문집
    • /
    • 제25권4호
    • /
    • pp.431-440
    • /
    • 2013
  • 본 연구에서는 HSA800 후판 강재에 적합한 용접재를 선정하고자 표준인장실험을 수행하였다. 본 연구 수행 당시 HSA800 강재에 적용가능한 용접재로 GMAW 용접재(외국산)와 FCAW 용접재(국내산) 두 가지가 추천되어 이들을 사용하였다. 맞댐용접상세와 루트간격을 주요 실험변수로하여 표준인장실험을 통해 용접부의 성능을 평가하였다. 강도에 대한 설계요구조건은 두 용접재 모두 만족하였으나 연성능력 측면에서 GMAW 용접재 보다는 FCAW 용접재가 일관되고 우수한 거동을 보임이 실험적으로 확인되었다. 특히 GMAW 용접재는 용접효율과 작업성의 문제로 현장에서의 상향용접이 어려운 것으로 파악되었다. 같은 완전용입용접이라도 Single bevel보다는 V-groove가 안정적인 구조거동을 보이는 것으로 나타났다. 또한 현행 용접기준의 표준루트 간격을 벗어날 경우 용착의 어려움으로 비정상 파단면이 형성되고 접합성능도 저하됨이 확인되었다. 부분용입용접 접합부의 실험결과에 의할 때 현행 AISC 기준의 부분용입용접부 강도규정은 매우 보수적임이 확인되었다.